Hybrid recorder SBR-EW100 / EW180Handling Company
RKC INSTRUMENTCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power frequency | Brightness settings | Setting screen display | Recording paper length | Chart paper feed speed change | Chart paper feed speed | Recording accuracy | Recording method | Recording cycle | Language display | Display update cycle | Display method | Display content | Paper feed accuracy | RTD input | Measurement period | Effective recording width | Dot model resolution | Rated power supply voltage | Input calculation function | Input resistance | Input external resistance | Usable power supply voltage range | Operating temperature and humidity range | Memory backup | Filter function | Burnout | Bar graph display | Type | Pen model dead band |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SBR-EW101-1 |
Available upon quote |
50Hz/60Hz (automatic switching) |
Brightness level configurable |
Interactive display of various recorder settings |
16m (folding) |
Speed 1/Speed 2 can be switched by remote control (optional) |
5~12,000mm/h (82 steps) |
Measurement accuracy ± (0.3% of recording span) |
Disposable felt pen, plotter pen |
Continuous recording for each channel |
Japanese display |
AUTO: 1~5 seconds |
VFD (101×16 dot matrix) |
Digital display, bar graph, flag display, DI/DO status, date/time, etc. *Display settings can be registered in up to 15 formats from approximately 80 formats. |
Within ±0.1% *However, if the feed is more than 1,000 mm, the print scale is based on the recording paper. |
1 wire 10Ω or less (all 3 wires must be equal) |
0.125 seconds for all channels |
100mm |
- |
100~240VAC (automatic switching) |
Channel difference, linear scaling, square root calculation (with low cut function), bias (arithmetic addition) |
Voltage range below 200mVDC and thermocouple: 10MΩ or above |
DC voltage, thermocouple input: 2kΩ or less |
90~132VAC, 180~264VAC |
0~50℃, 20~80%RH (at 5~40℃) |
Set value and clock operation protected by lithium battery |
Signal damping |
Detected for TC, DCV (1~5V) |
Measured value: Can display left/right edge reference or center zero bar graph *Can be specified for each channel |
SBR-EW100 1 pen recorder |
Less than 0.2% of recording span |
|
SBR-EW102-1 |
Available upon quote |
50Hz/60Hz (automatic switching) |
Brightness level configurable |
Interactive display of various recorder settings |
16m (folding) |
Speed 1/Speed 2 can be switched by remote control (optional) |
5~12,000mm/h (82 steps) |
Measurement accuracy ± (0.3% of recording span) |
Disposable felt pen, plotter pen |
Continuous recording for each channel |
Japanese display |
AUTO: 1~5 seconds |
VFD (101×16 dot matrix) |
Digital display, bar graph, flag display, DI/DO status, date/time, etc. *Display settings can be registered in up to 15 formats from approximately 80 formats. |
Within ±0.1% *However, if the feed is more than 1,000 mm, the print scale is based on the recording paper. |
1 wire 10Ω or less (all 3 wires must be equal) |
0.125 seconds for all channels |
100mm |
- |
100~240VAC (automatic switching) |
Channel difference, linear scaling, square root calculation (with low cut function), bias (arithmetic addition) |
Voltage range below 200mVDC and thermocouple: 10MΩ or above |
DC voltage, thermocouple input: 2kΩ or less |
90~132VAC, 180~264VAC |
0~50℃, 20~80%RH (at 5~40℃) |
Set value and clock operation protected by lithium battery |
Signal damping |
Detected for TC, DCV (1~5V) |
Measured value: Can display left/right edge reference or center zero bar graph *Can be specified for each channel |
SBR-EW100 2 pen recorder |
Less than 0.2% of recording span |
|
SBR-EW103-1 |
Available upon quote |
50Hz/60Hz (automatic switching) |
Brightness level configurable |
Interactive display of various recorder settings |
16m (folding) |
Speed 1/Speed 2 can be switched by remote control (optional) |
5~12,000mm/h (82 steps) |
Measurement accuracy ± (0.3% of recording span) |
Disposable felt pen, plotter pen |
Continuous recording for each channel |
Japanese display |
AUTO: 1~5 seconds |
VFD (101×16 dot matrix) |
Digital display, bar graph, flag display, DI/DO status, date/time, etc. *Display settings can be registered in up to 15 formats from approximately 80 formats. |
Within ±0.1% *However, if the feed is more than 1,000 mm, the print scale is based on the recording paper. |
1 wire 10Ω or less (all 3 wires must be equal) |
0.125 seconds for all channels |
100mm |
- |
100~240VAC (automatic switching) |
Channel difference, linear scaling, square root calculation (with low cut function), bias (arithmetic addition) |
Voltage range below 200mVDC and thermocouple: 10MΩ or above |
DC voltage, thermocouple input: 2kΩ or less |
90~132VAC, 180~264VAC |
0~50℃, 20~80%RH (at 5~40℃) |
Set value and clock operation protected by lithium battery |
Signal damping |
Detected for TC, DCV (1~5V) |
Measured value: Can display left/right edge reference or center zero bar graph *Can be specified for each channel |
SBR-EW100 3 pen recorder |
Less than 0.2% of recording span |
|
SBR-EW104-1 |
Available upon quote |
50Hz/60Hz (automatic switching) |
Brightness level configurable |
Interactive display of various recorder settings |
16m (folding) |
Speed 1/Speed 2 can be switched by remote control (optional) |
5~12,000mm/h (82 steps) |
Measurement accuracy ± (0.3% of recording span) |
Disposable felt pen, plotter pen |
Continuous recording for each channel |
Japanese display |
AUTO: 1~5 seconds |
VFD (101×16 dot matrix) |
Digital display, bar graph, flag display, DI/DO status, date/time, etc. *Display settings can be registered in up to 15 formats from approximately 80 formats. |
Within ±0.1% *However, if the feed is more than 1,000 mm, the print scale is based on the recording paper. |
1 wire 10Ω or less (all 3 wires must be equal) |
0.125 seconds for all channels |
100mm |
- |
100~240VAC (automatic switching) |
Channel difference, linear scaling, square root calculation (with low cut function), bias (arithmetic addition) |
Voltage range below 200mVDC and thermocouple: 10MΩ or above |
DC voltage, thermocouple input: 2kΩ or less |
90~132VAC, 180~264VAC |
0~50℃, 20~80%RH (at 5~40℃) |
Set value and clock operation protected by lithium battery |
Signal damping |
Detected for TC, DCV (1~5V) |
Measured value: Can display left/right edge reference or center zero bar graph *Can be specified for each channel |
SBR-EW100 4 pen recorder |
Less than 0.2% of recording span |
|
SBR-EW106-1 |
Available upon quote |
50Hz/60Hz (automatic switching) |
Brightness level configurable |
Interactive display of various recorder settings |
16m (folding) |
Speed 1/Speed 2 can be switched by remote control (optional) |
1~1,500mm/h (1mm step) |
Measurement accuracy ± (0.3% of recording span) |
6 color wire dots |
6 points/10 seconds *Fastest recording cycle |
Japanese display |
AUTO: 1~5 seconds |
VFD (101×16 dot matrix) |
Digital display, bar graph, flag display, DI/DO status, date/time, etc. *Display settings can be registered in up to 15 formats from approximately 80 formats. |
Within ±0.1% *However, if the feed is more than 1,000 mm, the print scale is based on the recording paper. |
1 wire 10Ω or less (all 3 wires must be equal) |
1 second/6 points |
100mm |
0.1mm |
100~240VAC (automatic switching) |
Channel difference, linear scaling, square root calculation (with low cut function), bias (arithmetic addition) |
Voltage range below 200mVDC and thermocouple: 10MΩ or above |
DC voltage, thermocouple input: 2kΩ or less |
90~132VAC, 180~264VAC |
0~50℃, 20~80%RH (at 5~40℃) |
Set value and clock operation protected by lithium battery |
Moving average |
Detected for TC, DCV (1~5V) |
Measured value: Can display left/right edge reference or center zero bar graph *Can be specified for each channel |
SBR-EW100 6 RBI recorder |
- | |
SBR-EW181-1 |
Available upon quote |
50Hz/60Hz (automatic switching) |
Brightness level configurable |
Interactive display of various recorder settings |
20m (foldable) |
Speed 1/Speed 2 can be switched by remote control (optional) |
5~12,000mm/h (82 steps) |
Measurement accuracy ± (0.3% of recording span) |
Disposable felt pen, plotter pen |
Continuous recording for each channel |
Japanese display |
AUTO: 1~5 seconds |
VFD (181×16 dot matrix) |
Digital display, bar graph, flag display, DI/DO status, date/time, etc. *Display settings can be registered in up to 15 formats from approximately 80 formats. |
Within ±0.1% *However, if the feed is more than 1,000 mm, the print scale is based on the recording paper. |
1 wire 10Ω or less (all 3 wires must be equal) |
0.125 seconds for all channels |
180mm |
- |
100~240VAC (automatic switching) |
Channel difference, linear scaling, square root calculation (with low cut function), bias (arithmetic addition) |
Voltage range below 200mVDC and thermocouple: 10MΩ or above |
DC voltage, thermocouple input: 2kΩ or less |
90~132VAC, 180~264VAC |
0~50℃, 20~80%RH (at 5~40℃) |
Set value and clock operation protected by lithium battery |
Signal damping |
Detected for TC, DCV (1~5V) |
Measured value: Can display left/right edge reference or center zero bar graph *Can be specified for each channel |
SBR-EW180 1 pen recorder |
Less than 0.2% of recording span |
|
SBR-EW182-1 |
Available upon quote |
50Hz/60Hz (automatic switching) |
Brightness level configurable |
Interactive display of various recorder settings |
20m (foldable) |
Speed 1/Speed 2 can be switched by remote control (optional) |
5~12,000mm/h (82 steps) |
Measurement accuracy ± (0.3% of recording span) |
Disposable felt pen, plotter pen |
Continuous recording for each channel |
Japanese display |
AUTO: 1~5 seconds |
VFD (181×16 dot matrix) |
Digital display, bar graph, flag display, DI/DO status, date/time, etc. *Display settings can be registered in up to 15 formats from approximately 80 formats. |
Within ±0.1% *However, if the feed is more than 1,000 mm, the print scale is based on the recording paper. |
1 wire 10Ω or less (all 3 wires must be equal) |
0.125 seconds for all channels |
180mm |
- |
100~240VAC (automatic switching) |
Channel difference, linear scaling, square root calculation (with low cut function), bias (arithmetic addition) |
Voltage range below 200mVDC and thermocouple: 10MΩ or above |
DC voltage, thermocouple input: 2kΩ or less |
90~132VAC, 180~264VAC |
0~50℃, 20~80%RH (at 5~40℃) |
Set value and clock operation protected by lithium battery |
Signal damping |
Detected for TC, DCV (1~5V) |
Measured value: Can display left/right edge reference or center zero bar graph *Can be specified for each channel |
SBR-EW180 2 pen recorder |
Less than 0.2% of recording span |
|
SBR-EW183-1 |
Available upon quote |
50Hz/60Hz (automatic switching) |
Brightness level configurable |
Interactive display of various recorder settings |
20m (foldable) |
Speed 1/Speed 2 can be switched by remote control (optional) |
5~12,000mm/h (82 steps) |
Measurement accuracy ± (0.3% of recording span) |
Disposable felt pen, plotter pen |
Continuous recording for each channel |
Japanese display |
AUTO: 1~5 seconds |
VFD (181×16 dot matrix) |
Digital display, bar graph, flag display, DI/DO status, date/time, etc. *Display settings can be registered in up to 15 formats from approximately 80 formats. |
Within ±0.1% *However, if the feed is more than 1,000 mm, the print scale is based on the recording paper. |
1 wire 10Ω or less (all 3 wires must be equal) |
0.125 seconds for all channels |
180mm |
- |
100~240VAC (automatic switching) |
Channel difference, linear scaling, square root calculation (with low cut function), bias (arithmetic addition) |
Voltage range below 200mVDC and thermocouple: 10MΩ or above |
DC voltage, thermocouple input: 2kΩ or less |
90~132VAC, 180~264VAC |
0~50℃, 20~80%RH (at 5~40℃) |
Set value and clock operation protected by lithium battery |
Signal damping |
Detected for TC, DCV (1~5V) |
Measured value: Can display left/right edge reference or center zero bar graph *Can be specified for each channel |
SBR-EW180 3 pen recorder |
Less than 0.2% of recording span |
|
SBR-EW184-1 |
Available upon quote |
50Hz/60Hz (automatic switching) |
Brightness level configurable |
Interactive display of various recorder settings |
20m (foldable) |
Speed 1/Speed 2 can be switched by remote control (optional) |
5~12,000mm/h (82 steps) |
Measurement accuracy ± (0.3% of recording span) |
Disposable felt pen, plotter pen |
Continuous recording for each channel |
Japanese display |
AUTO: 1~5 seconds |
VFD (181×16 dot matrix) |
Digital display, bar graph, flag display, DI/DO status, date/time, etc. *Display settings can be registered in up to 15 formats from approximately 80 formats. |
Within ±0.1% *However, if the feed is more than 1,000 mm, the print scale is based on the recording paper. |
1 wire 10Ω or less (all 3 wires must be equal) |
0.125 seconds for all channels |
180mm |
- |
100~240VAC (automatic switching) |
Channel difference, linear scaling, square root calculation (with low cut function), bias (arithmetic addition) |
Voltage range below 200mVDC and thermocouple: 10MΩ or above |
DC voltage, thermocouple input: 2kΩ or less |
90~132VAC, 180~264VAC |
0~50℃, 20~80%RH (at 5~40℃) |
Set value and clock operation protected by lithium battery |
Signal damping |
Detected for TC, DCV (1~5V) |
Measured value: Can display left/right edge reference or center zero bar graph *Can be specified for each channel |
SBR-EW180 4 pen recorder |
Less than 0.2% of recording span |
|
SBR-EW186-1 |
Available upon quote |
50Hz/60Hz (automatic switching) |
Brightness level configurable |
Interactive display of various recorder settings |
20m (foldable) |
Speed 1/Speed 2 can be switched by remote control (optional) |
1~1,500mm/h (1mm step) |
Measurement accuracy ± (0.3% of recording span) |
6 color wire dots |
6 points/10 seconds *Fastest recording cycle |
Japanese display |
AUTO: 1~5 seconds |
VFD (181×16 dot matrix) |
Digital display, bar graph, flag display, DI/DO status, date/time, etc. *Display settings can be registered in up to 15 formats from approximately 80 formats. |
Within ±0.1% *However, if the feed is more than 1,000 mm, the print scale is based on the recording paper. |
1 wire 10Ω or less (all 3 wires must be equal) |
1 second/6 points |
180mm |
0.1mm |
100~240VAC (automatic switching) |
Channel difference, linear scaling, square root calculation (with low cut function), bias (arithmetic addition) |
Voltage range below 200mVDC and thermocouple: 10MΩ or above |
DC voltage, thermocouple input: 2kΩ or less |
90~132VAC, 180~264VAC |
0~50℃, 20~80%RH (at 5~40℃) |
Set value and clock operation protected by lithium battery |
Moving average |
Detected for TC, DCV (1~5V) |
Measured value: Can display left/right edge reference or center zero bar graph *Can be specified for each channel |
SBR-EW180 6 RBI recorder |
- |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.