■Intuitive operation via touch panel Equipped with a touch panel type 5.7 inch LCD display. It can be operated intuitively. ■Press the REC button to start recording immediately; software is also included -Press the REC button to start recording. ・Data can be saved to SD card. You can easily view and manage them using the included software. ■Abundant input formats External remote AI (optional) and MODBUS master function allow connection of controllers, etc., and recording of up to 48 channels including input from the main unit is possible. *When connecting MODBUS master communication, the number of connected channels is limited depending on the number of communication items assigned. ■Extended security function: Compatible with 21 CFR Part 11 (optional) ・Access restriction: Only users who have registered an account can operate it. ・Audit trail: Automatically records operation history such as setting value changes, recording start/stop, etc. ・Electronic signature/signature data output: It is possible to print trends and instantaneous values ​​with signature data added. ・Data tampering/corruption detection: Restricts viewing of detected data. *Other product numbers are available.

  • Product

    Paperless recorder VGR-B100

Share this product


240+ people viewing

Last viewed: 9 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Paperless recorder VGR-B100

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Allowable input wire resistance (resistance temperature detector) Arithmetic function Burnout function Data format Data recording cycle Display Display color Display group Display language Display update cycle Effect of signal source resistance (thermocouple input) External recording medium F value calculation function Input circuit Input type Input/output function (optional) Internal memory Main record Measurement period Number of analog input points Other recorded data PV digital filter RS-485 communication function (optional) Recording capacity Recording method Scalable range Square root calculation function Sub record Trend data Unit symbol
Paperless recorder VGR-B100-Part Number-VGR-B103-00

VGR-B103-00

Available upon quote 5Ω or less per wire Number of calculation channels: 36 points
Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Thermocouple, standard equipment for mV voltage input. Can be set with or without. You can choose from either binary or binary + CSV format. 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) 16 colors Number of groups: 6 main records, 1 sub record
Number of channels: Up to 12 channels can be displayed in each group
Select Japanese/English from the setting screen (default setting is English) 1 second Approximately 0.18μV/Ω SD memory card (compatible with SD/SDHC standards) The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Input mutual isolation DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector No input/output function Approximately 100MB Records each channel data of 6 groups set in display group.
Recorded contents include trend data, event data, and message data.
100ms Analog input signal: 3 points Alarm information, message record Can be set from 0 to 99 seconds for each channel No RS-485 communication SD standard: max. 2GB, SDHC standard: max. 32GB Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily Square root operation on each channel input value Records each channel data of one group set in display group.
The recorded content is only trend data.
*The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input.
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. Select from preset units or 20 units (up to 8 characters each) that can be created.
Paperless recorder VGR-B100-Part Number-VGR-B103-01

VGR-B103-01

Available upon quote 5Ω or less per wire Number of calculation channels: 36 points
Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Thermocouple, standard equipment for mV voltage input. Can be set with or without. You can choose from either binary or binary + CSV format. 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) 16 colors Number of groups: 6 main records, 1 sub record
Number of channels: Up to 12 channels can be displayed in each group
Select Japanese/English from the setting screen (default setting is English) 1 second Approximately 0.18μV/Ω SD memory card (compatible with SD/SDHC standards) The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Input mutual isolation DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector With DI/DO (DI 9 points, DO 12 points) Approximately 100MB Records each channel data of 6 groups set in display group.
Recorded contents include trend data, event data, and message data.
100ms Analog input signal: 3 points Alarm information, message record Can be set from 0 to 99 seconds for each channel No RS-485 communication SD standard: max. 2GB, SDHC standard: max. 32GB Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily Square root operation on each channel input value Records each channel data of one group set in display group.
The recorded content is only trend data.
*The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input.
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. Select from preset units or 20 units (up to 8 characters each) that can be created.
Paperless recorder VGR-B100-Part Number-VGR-B103-02

VGR-B103-02

Available upon quote 5Ω or less per wire Number of calculation channels: 36 points
Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Thermocouple, standard equipment for mV voltage input. Can be set with or without. You can choose from either binary or binary + CSV format. 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) 16 colors Number of groups: 6 main records, 1 sub record
Number of channels: Up to 12 channels can be displayed in each group
Select Japanese/English from the setting screen (default setting is English) 1 second Approximately 0.18μV/Ω SD memory card (compatible with SD/SDHC standards) The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Input mutual isolation DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector With relay contact output Approximately 100MB Records each channel data of 6 groups set in display group.
Recorded contents include trend data, event data, and message data.
100ms Analog input signal: 3 points Alarm information, message record Can be set from 0 to 99 seconds for each channel No RS-485 communication SD standard: max. 2GB, SDHC standard: max. 32GB Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily Square root operation on each channel input value Records each channel data of one group set in display group.
The recorded content is only trend data.
*The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input.
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. Select from preset units or 20 units (up to 8 characters each) that can be created.
Paperless recorder VGR-B100-Part Number-VGR-B103-60

VGR-B103-60

Available upon quote 5Ω or less per wire Number of calculation channels: 36 points
Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Thermocouple, standard equipment for mV voltage input. Can be set with or without. You can choose from either binary or binary + CSV format. 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) 16 colors Number of groups: 6 main records, 1 sub record
Number of channels: Up to 12 channels can be displayed in each group
Select Japanese/English from the setting screen (default setting is English) 1 second Approximately 0.18μV/Ω SD memory card (compatible with SD/SDHC standards) The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Input mutual isolation DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector No input/output function Approximately 100MB Records each channel data of 6 groups set in display group.
Recorded contents include trend data, event data, and message data.
100ms Analog input signal: 3 points Alarm information, message record Can be set from 0 to 99 seconds for each channel RS-485 communication available SD standard: max. 2GB, SDHC standard: max. 32GB Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily Square root operation on each channel input value Records each channel data of one group set in display group.
The recorded content is only trend data.
*The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input.
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. Select from preset units or 20 units (up to 8 characters each) that can be created.
Paperless recorder VGR-B100-Part Number-VGR-B103-61

VGR-B103-61

Available upon quote 5Ω or less per wire Number of calculation channels: 36 points
Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Thermocouple, standard equipment for mV voltage input. Can be set with or without. You can choose from either binary or binary + CSV format. 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) 16 colors Number of groups: 6 main records, 1 sub record
Number of channels: Up to 12 channels can be displayed in each group
Select Japanese/English from the setting screen (default setting is English) 1 second Approximately 0.18μV/Ω SD memory card (compatible with SD/SDHC standards) The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Input mutual isolation DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector With DI/DO (DI 9 points, DO 12 points) Approximately 100MB Records each channel data of 6 groups set in display group.
Recorded contents include trend data, event data, and message data.
100ms Analog input signal: 3 points Alarm information, message record Can be set from 0 to 99 seconds for each channel RS-485 communication available SD standard: max. 2GB, SDHC standard: max. 32GB Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily Square root operation on each channel input value Records each channel data of one group set in display group.
The recorded content is only trend data.
*The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input.
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. Select from preset units or 20 units (up to 8 characters each) that can be created.
Paperless recorder VGR-B100-Part Number-VGR-B103-62

VGR-B103-62

Available upon quote 5Ω or less per wire Number of calculation channels: 36 points
Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Thermocouple, standard equipment for mV voltage input. Can be set with or without. You can choose from either binary or binary + CSV format. 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) 16 colors Number of groups: 6 main records, 1 sub record
Number of channels: Up to 12 channels can be displayed in each group
Select Japanese/English from the setting screen (default setting is English) 1 second Approximately 0.18μV/Ω SD memory card (compatible with SD/SDHC standards) The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Input mutual isolation DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector With relay contact output Approximately 100MB Records each channel data of 6 groups set in display group.
Recorded contents include trend data, event data, and message data.
100ms Analog input signal: 3 points Alarm information, message record Can be set from 0 to 99 seconds for each channel RS-485 communication available SD standard: max. 2GB, SDHC standard: max. 32GB Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily Square root operation on each channel input value Records each channel data of one group set in display group.
The recorded content is only trend data.
*The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input.
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. Select from preset units or 20 units (up to 8 characters each) that can be created.
Paperless recorder VGR-B100-Part Number-VGR-B106-00

VGR-B106-00

Available upon quote 5Ω or less per wire Number of calculation channels: 36 points
Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Thermocouple, standard equipment for mV voltage input. Can be set with or without. You can choose from either binary or binary + CSV format. 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) 16 colors Number of groups: 6 main records, 1 sub record
Number of channels: Up to 12 channels can be displayed in each group
Select Japanese/English from the setting screen (default setting is English) 1 second Approximately 0.18μV/Ω SD memory card (compatible with SD/SDHC standards) The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Input mutual isolation DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector No input/output function Approximately 100MB Records each channel data of 6 groups set in display group.
Recorded contents include trend data, event data, and message data.
100ms Analog input signal: 6 points Alarm information, message record Can be set from 0 to 99 seconds for each channel No RS-485 communication SD standard: max. 2GB, SDHC standard: max. 32GB Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily Square root operation on each channel input value Records each channel data of one group set in display group.
The recorded content is only trend data.
*The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input.
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. Select from preset units or 20 units (up to 8 characters each) that can be created.
Paperless recorder VGR-B100-Part Number-VGR-B106-01

VGR-B106-01

Available upon quote 5Ω or less per wire Number of calculation channels: 36 points
Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Thermocouple, standard equipment for mV voltage input. Can be set with or without. You can choose from either binary or binary + CSV format. 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) 16 colors Number of groups: 6 main records, 1 sub record
Number of channels: Up to 12 channels can be displayed in each group
Select Japanese/English from the setting screen (default setting is English) 1 second Approximately 0.18μV/Ω SD memory card (compatible with SD/SDHC standards) The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Input mutual isolation DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector With DI/DO (DI 9 points, DO 12 points) Approximately 100MB Records each channel data of 6 groups set in display group.
Recorded contents include trend data, event data, and message data.
100ms Analog input signal: 6 points Alarm information, message record Can be set from 0 to 99 seconds for each channel No RS-485 communication SD standard: max. 2GB, SDHC standard: max. 32GB Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily Square root operation on each channel input value Records each channel data of one group set in display group.
The recorded content is only trend data.
*The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input.
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. Select from preset units or 20 units (up to 8 characters each) that can be created.
Paperless recorder VGR-B100-Part Number-VGR-B106-02

VGR-B106-02

Available upon quote 5Ω or less per wire Number of calculation channels: 36 points
Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Thermocouple, standard equipment for mV voltage input. Can be set with or without. You can choose from either binary or binary + CSV format. 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) 16 colors Number of groups: 6 main records, 1 sub record
Number of channels: Up to 12 channels can be displayed in each group
Select Japanese/English from the setting screen (default setting is English) 1 second Approximately 0.18μV/Ω SD memory card (compatible with SD/SDHC standards) The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Input mutual isolation DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector With relay contact output Approximately 100MB Records each channel data of 6 groups set in display group.
Recorded contents include trend data, event data, and message data.
100ms Analog input signal: 6 points Alarm information, message record Can be set from 0 to 99 seconds for each channel No RS-485 communication SD standard: max. 2GB, SDHC standard: max. 32GB Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily Square root operation on each channel input value Records each channel data of one group set in display group.
The recorded content is only trend data.
*The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input.
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. Select from preset units or 20 units (up to 8 characters each) that can be created.
Paperless recorder VGR-B100-Part Number-VGR-B106-60

VGR-B106-60

Available upon quote 5Ω or less per wire Number of calculation channels: 36 points
Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Thermocouple, standard equipment for mV voltage input. Can be set with or without. You can choose from either binary or binary + CSV format. 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) 16 colors Number of groups: 6 main records, 1 sub record
Number of channels: Up to 12 channels can be displayed in each group
Select Japanese/English from the setting screen (default setting is English) 1 second Approximately 0.18μV/Ω SD memory card (compatible with SD/SDHC standards) The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature.
Calculation details can only be set and checked using the parameter loader software (standard included software).
Input mutual isolation DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector No input/output function Approximately 100MB Records each channel data of 6 groups set in display group.
Recorded contents include trend data, event data, and message data.
100ms Analog input signal: 6 points Alarm information, message record Can be set from 0 to 99 seconds for each channel RS-485 communication available SD standard: max. 2GB, SDHC standard: max. 32GB Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily Square root operation on each channel input value Records each channel data of one group set in display group.
The recorded content is only trend data.
*The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input.
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. Select from preset units or 20 units (up to 8 characters each) that can be created.

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of RKC INSTRUMENT


View more products of RKC INSTRUMENT

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree