Product
Paperless recorder VGR-B100Handling Company
RKC INSTRUMENTCategories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Allowable input wire resistance (resistance temperature detector) | Arithmetic function | Burnout function | Data format | Data recording cycle | Display | Display color | Display group | Display language | Display update cycle | Effect of signal source resistance (thermocouple input) | External recording medium | F value calculation function | Input circuit | Input type | Input/output function (optional) | Internal memory | Main record | Measurement period | Number of analog input points | Other recorded data | PV digital filter | RS-485 communication function (optional) | Recording capacity | Recording method | Scalable range | Square root calculation function | Sub record | Trend data | Unit symbol |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VGR-B103-00 |
Available upon quote | 5Ω or less per wire |
Number of calculation channels: 36 points Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Thermocouple, standard equipment for mV voltage input. Can be set with or without. | You can choose from either binary or binary + CSV format. | 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) | Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) | 16 colors |
Number of groups: 6 main records, 1 sub record Number of channels: Up to 12 channels can be displayed in each group |
Select Japanese/English from the setting screen (default setting is English) | 1 second | Approximately 0.18μV/Ω | SD memory card (compatible with SD/SDHC standards) |
The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Input mutual isolation | DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector | No input/output function | Approximately 100MB |
Records each channel data of 6 groups set in display group. Recorded contents include trend data, event data, and message data. |
100ms | Analog input signal: 3 points | Alarm information, message record | Can be set from 0 to 99 seconds for each channel | No RS-485 communication | SD standard: max. 2GB, SDHC standard: max. 32GB | Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. | ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily | Square root operation on each channel input value |
Records each channel data of one group set in display group. The recorded content is only trend data. *The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input. |
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. | Select from preset units or 20 units (up to 8 characters each) that can be created. | |
VGR-B103-01 |
Available upon quote | 5Ω or less per wire |
Number of calculation channels: 36 points Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Thermocouple, standard equipment for mV voltage input. Can be set with or without. | You can choose from either binary or binary + CSV format. | 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) | Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) | 16 colors |
Number of groups: 6 main records, 1 sub record Number of channels: Up to 12 channels can be displayed in each group |
Select Japanese/English from the setting screen (default setting is English) | 1 second | Approximately 0.18μV/Ω | SD memory card (compatible with SD/SDHC standards) |
The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Input mutual isolation | DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector | With DI/DO (DI 9 points, DO 12 points) | Approximately 100MB |
Records each channel data of 6 groups set in display group. Recorded contents include trend data, event data, and message data. |
100ms | Analog input signal: 3 points | Alarm information, message record | Can be set from 0 to 99 seconds for each channel | No RS-485 communication | SD standard: max. 2GB, SDHC standard: max. 32GB | Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. | ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily | Square root operation on each channel input value |
Records each channel data of one group set in display group. The recorded content is only trend data. *The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input. |
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. | Select from preset units or 20 units (up to 8 characters each) that can be created. | |
VGR-B103-02 |
Available upon quote | 5Ω or less per wire |
Number of calculation channels: 36 points Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Thermocouple, standard equipment for mV voltage input. Can be set with or without. | You can choose from either binary or binary + CSV format. | 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) | Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) | 16 colors |
Number of groups: 6 main records, 1 sub record Number of channels: Up to 12 channels can be displayed in each group |
Select Japanese/English from the setting screen (default setting is English) | 1 second | Approximately 0.18μV/Ω | SD memory card (compatible with SD/SDHC standards) |
The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Input mutual isolation | DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector | With relay contact output | Approximately 100MB |
Records each channel data of 6 groups set in display group. Recorded contents include trend data, event data, and message data. |
100ms | Analog input signal: 3 points | Alarm information, message record | Can be set from 0 to 99 seconds for each channel | No RS-485 communication | SD standard: max. 2GB, SDHC standard: max. 32GB | Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. | ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily | Square root operation on each channel input value |
Records each channel data of one group set in display group. The recorded content is only trend data. *The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input. |
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. | Select from preset units or 20 units (up to 8 characters each) that can be created. | |
VGR-B103-60 |
Available upon quote | 5Ω or less per wire |
Number of calculation channels: 36 points Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Thermocouple, standard equipment for mV voltage input. Can be set with or without. | You can choose from either binary or binary + CSV format. | 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) | Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) | 16 colors |
Number of groups: 6 main records, 1 sub record Number of channels: Up to 12 channels can be displayed in each group |
Select Japanese/English from the setting screen (default setting is English) | 1 second | Approximately 0.18μV/Ω | SD memory card (compatible with SD/SDHC standards) |
The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Input mutual isolation | DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector | No input/output function | Approximately 100MB |
Records each channel data of 6 groups set in display group. Recorded contents include trend data, event data, and message data. |
100ms | Analog input signal: 3 points | Alarm information, message record | Can be set from 0 to 99 seconds for each channel | RS-485 communication available | SD standard: max. 2GB, SDHC standard: max. 32GB | Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. | ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily | Square root operation on each channel input value |
Records each channel data of one group set in display group. The recorded content is only trend data. *The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input. |
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. | Select from preset units or 20 units (up to 8 characters each) that can be created. | |
VGR-B103-61 |
Available upon quote | 5Ω or less per wire |
Number of calculation channels: 36 points Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Thermocouple, standard equipment for mV voltage input. Can be set with or without. | You can choose from either binary or binary + CSV format. | 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) | Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) | 16 colors |
Number of groups: 6 main records, 1 sub record Number of channels: Up to 12 channels can be displayed in each group |
Select Japanese/English from the setting screen (default setting is English) | 1 second | Approximately 0.18μV/Ω | SD memory card (compatible with SD/SDHC standards) |
The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Input mutual isolation | DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector | With DI/DO (DI 9 points, DO 12 points) | Approximately 100MB |
Records each channel data of 6 groups set in display group. Recorded contents include trend data, event data, and message data. |
100ms | Analog input signal: 3 points | Alarm information, message record | Can be set from 0 to 99 seconds for each channel | RS-485 communication available | SD standard: max. 2GB, SDHC standard: max. 32GB | Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. | ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily | Square root operation on each channel input value |
Records each channel data of one group set in display group. The recorded content is only trend data. *The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input. |
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. | Select from preset units or 20 units (up to 8 characters each) that can be created. | |
VGR-B103-62 |
Available upon quote | 5Ω or less per wire |
Number of calculation channels: 36 points Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Thermocouple, standard equipment for mV voltage input. Can be set with or without. | You can choose from either binary or binary + CSV format. | 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) | Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) | 16 colors |
Number of groups: 6 main records, 1 sub record Number of channels: Up to 12 channels can be displayed in each group |
Select Japanese/English from the setting screen (default setting is English) | 1 second | Approximately 0.18μV/Ω | SD memory card (compatible with SD/SDHC standards) |
The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Input mutual isolation | DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector | With relay contact output | Approximately 100MB |
Records each channel data of 6 groups set in display group. Recorded contents include trend data, event data, and message data. |
100ms | Analog input signal: 3 points | Alarm information, message record | Can be set from 0 to 99 seconds for each channel | RS-485 communication available | SD standard: max. 2GB, SDHC standard: max. 32GB | Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. | ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily | Square root operation on each channel input value |
Records each channel data of one group set in display group. The recorded content is only trend data. *The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input. |
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. | Select from preset units or 20 units (up to 8 characters each) that can be created. | |
VGR-B106-00 |
Available upon quote | 5Ω or less per wire |
Number of calculation channels: 36 points Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Thermocouple, standard equipment for mV voltage input. Can be set with or without. | You can choose from either binary or binary + CSV format. | 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) | Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) | 16 colors |
Number of groups: 6 main records, 1 sub record Number of channels: Up to 12 channels can be displayed in each group |
Select Japanese/English from the setting screen (default setting is English) | 1 second | Approximately 0.18μV/Ω | SD memory card (compatible with SD/SDHC standards) |
The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Input mutual isolation | DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector | No input/output function | Approximately 100MB |
Records each channel data of 6 groups set in display group. Recorded contents include trend data, event data, and message data. |
100ms | Analog input signal: 6 points | Alarm information, message record | Can be set from 0 to 99 seconds for each channel | No RS-485 communication | SD standard: max. 2GB, SDHC standard: max. 32GB | Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. | ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily | Square root operation on each channel input value |
Records each channel data of one group set in display group. The recorded content is only trend data. *The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input. |
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. | Select from preset units or 20 units (up to 8 characters each) that can be created. | |
VGR-B106-01 |
Available upon quote | 5Ω or less per wire |
Number of calculation channels: 36 points Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Thermocouple, standard equipment for mV voltage input. Can be set with or without. | You can choose from either binary or binary + CSV format. | 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) | Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) | 16 colors |
Number of groups: 6 main records, 1 sub record Number of channels: Up to 12 channels can be displayed in each group |
Select Japanese/English from the setting screen (default setting is English) | 1 second | Approximately 0.18μV/Ω | SD memory card (compatible with SD/SDHC standards) |
The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Input mutual isolation | DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector | With DI/DO (DI 9 points, DO 12 points) | Approximately 100MB |
Records each channel data of 6 groups set in display group. Recorded contents include trend data, event data, and message data. |
100ms | Analog input signal: 6 points | Alarm information, message record | Can be set from 0 to 99 seconds for each channel | No RS-485 communication | SD standard: max. 2GB, SDHC standard: max. 32GB | Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. | ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily | Square root operation on each channel input value |
Records each channel data of one group set in display group. The recorded content is only trend data. *The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input. |
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. | Select from preset units or 20 units (up to 8 characters each) that can be created. | |
VGR-B106-02 |
Available upon quote | 5Ω or less per wire |
Number of calculation channels: 36 points Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Thermocouple, standard equipment for mV voltage input. Can be set with or without. | You can choose from either binary or binary + CSV format. | 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) | Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) | 16 colors |
Number of groups: 6 main records, 1 sub record Number of channels: Up to 12 channels can be displayed in each group |
Select Japanese/English from the setting screen (default setting is English) | 1 second | Approximately 0.18μV/Ω | SD memory card (compatible with SD/SDHC standards) |
The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Input mutual isolation | DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector | With relay contact output | Approximately 100MB |
Records each channel data of 6 groups set in display group. Recorded contents include trend data, event data, and message data. |
100ms | Analog input signal: 6 points | Alarm information, message record | Can be set from 0 to 99 seconds for each channel | No RS-485 communication | SD standard: max. 2GB, SDHC standard: max. 32GB | Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. | ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily | Square root operation on each channel input value |
Records each channel data of one group set in display group. The recorded content is only trend data. *The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input. |
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. | Select from preset units or 20 units (up to 8 characters each) that can be created. | |
VGR-B106-60 |
Available upon quote | 5Ω or less per wire |
Number of calculation channels: 36 points Arithmetic operations, general operations, integration operations, and F value operations are possible on each calculation channel. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Thermocouple, standard equipment for mV voltage input. Can be set with or without. | You can choose from either binary or binary + CSV format. | 1 second to 60 minutes (100 milliseconds can be selected for sub recording only) | Touch panel type 5.7 inch TFT color LCD (320 x 240 dots) | 16 colors |
Number of groups: 6 main records, 1 sub record Number of channels: Up to 12 channels can be displayed in each group |
Select Japanese/English from the setting screen (default setting is English) | 1 second | Approximately 0.18μV/Ω | SD memory card (compatible with SD/SDHC standards) |
The F value (lethal value of bacteria due to heat sterilization) is calculated for each channel from the measured temperature. Calculation details can only be set and checked using the parameter loader software (standard included software). |
Input mutual isolation | DC voltage, DC current (requires shunt resistance), thermocouple, resistance temperature detector | No input/output function | Approximately 100MB |
Records each channel data of 6 groups set in display group. Recorded contents include trend data, event data, and message data. |
100ms | Analog input signal: 6 points | Alarm information, message record | Can be set from 0 to 99 seconds for each channel | RS-485 communication available | SD standard: max. 2GB, SDHC standard: max. 32GB | Recording starts each time the REC button is turned on. Records with a new file name each time recording starts. | ±32,000 (DC voltage (current) input) *Decimal point position can be set arbitrarily | Square root operation on each channel input value |
Records each channel data of one group set in display group. The recorded content is only trend data. *The recording conditions can be selected from synchronized with main recording, when an alarm occurs, and when DI input. |
Saves either the average value, instantaneous value, or minimum and maximum measured value from the measurement data sampled in the measurement cycle. | Select from preset units or 20 units (up to 8 characters each) that can be created. |
Click on the part number for more information about each product