■Main features

・Overtemperature rise/overtemperature protection ・Temperature abnormality timer ・Measurement accuracy: ±0.3% of displayed value ・LCD display ・48×24mm (width×vertical) size ・Plugin structure

■ Compatible with FM standard Compact temperature high/low limit controller

The limit controller outputs a signal (relay contact output) if the temperature rises abnormally due to a failure of the temperature control device, etc. Even if the temperature returns to normal, the output is maintained until the operator performs a reset operation (front key, communication, or external contact). Additionally, as a standard function, it stores the peak value (maximum value) of time measurement and temperature in abnormal conditions, and clears the data by resetting or turning off the power. *Upper limit operation and lower limit operation can be changed as necessary (Factory setting: upper limit operation)

■What is FM standard?

The FM (Factory Mutual) standard is a standard that began in the United States to evaluate the safety and quality of fire prevention equipment. This certification evaluates the quality, capacity, durability, etc. of various equipment to prevent asset loss due to fire. This is one of the standards required when used in systems to prevent overheating and fire. SA200L has obtained FM3545: Temperature Limit SW certification, which is suitable for preventing excessive temperature rise in equipment, etc.

■1/32DIN size compact design

Compact design with 1/32 DIN size (48 x 24 mm) that does not take up much installation space.

■Settings locked by password

For added safety, the settings lock parameter is displayed when you enter the registered password, and it is equipped with a password setting lock function that allows you to lock/unlock the settings.

■Excellent maintainability with plug-in structure

The plug-in structure allows for easy maintenance, inspection, and instrument replacement. Demonstrates outstanding maintainability. *When side-adhesive instrumentation is used, it is not possible to pull out the internal device using the plug-in.

■Transmission output can be added (optional)

One transmission output point can be added for convenient connection with external equipment. *Output is possible by assigning transmission output to output 1 (OUT1).

■Communication function can be added (optional)

Multi-drop connection is possible using RS-485 serial communication. It can be managed by a host computer, etc. *Other product numbers are available.

  • Product

    Limit controller SA200L

Share this product


320+ people viewing

Last viewed: 5 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Limit controller SA200L

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Power supply voltage Waterproof and dustproof Applicable standards Mass Alarm 2 type Alarm 1 type Permissible ambient humidity Permissible ambient temperature Measurement accuracy Power consumption Body color Number of output points Output allocation Output content Output 2 Output 1 Effects of power outage Usage atmosphere Relay contact output electrical life Relay contact output Contact capacity Relay contact output Contact method Memory backup Digital filter Type Sampling period Other conditions Input/range PV bias CE marking Option
Limit controller SA200L-Part Number-SA200LK01-MN-3*NN-NN/A/

SA200LK01-MN-3*NN-NN/A/

Available upon quote

AC/DC 24V

No waterproof/dustproof structure

・FM: FM3545
・UL: UL61010-1
・C-UL:CAN/CSA-C22.2 NO.61010-1

Approximately 110g

No alarm function

No alarm function

5~95%RH (no condensation)
Absolute humidity: MAX.W.C 29.3 g/m3 dry air at 101.3 kPa

-10~+55℃

Thermocouple: ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is greater)

AC24V specifications: maximum 4VA
DC24V specification: max. 100mA

Black tone

2 points (Output 1 (OUT1), Output 2 (OUT2))

Standard output (Output 1: Limit output (non-excitation) Output 2: No alarm, alarm 1 output (excitation) or OR output of alarm 1 and alarm 2 (excitation)

Output 1 (OUT1): Relay contact output or current output
Output 2 (OUT2): No output or relay contact output
*Output type is fixed at the time of order and cannot be changed after purchase.

No output

Relay contact output

Power outages of 20msec or less will not affect operation.

There shall be no corrosive or flammable gas, and there shall be no heavy dust.

100,000 times or more (rated load)

AC 240V 2A (resistive load)
DC 30V 2A (resistive load)

1a contact

Data backup using non-volatile memory
(Number of rewrites: approximately 100,000 times, data storage retention period: approximately 10 years)

1~100 seconds (When set to 0: OFF)

Limit controller

0.5 seconds (switchable to 0.25 seconds)

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Thermocouple: K (JIS/IEC)
0~200℃

-span~+span (within -1999~+9,999digit)

Low voltage directive: EN61010-1
EMC Directive: EN61326-1
RoHS Directive: EN IEC 63000

No optional features

Limit controller SA200L-Part Number-SA200LK01-MN-3*NN-NN/A/02

SA200LK01-MN-3*NN-NN/A/02

Available upon quote

AC/DC 24V

No waterproof/dustproof structure

・FM: FM3545
・UL: UL61010-1
・C-UL:CAN/CSA-C22.2 NO.61010-1

Approximately 110g

No alarm function

No alarm function

5~95%RH (no condensation)
Absolute humidity: MAX.W.C 29.3 g/m3 dry air at 101.3 kPa

-10~+55℃

Thermocouple: ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is greater)

AC24V specifications: maximum 4VA
DC24V specification: max. 100mA

Black tone

2 points (Output 1 (OUT1), Output 2 (OUT2))

Output 1 Limit output (de-energized) Output 2 Logic AND output of 1st and 2nd alarms (excited)

Output 1 (OUT1): Relay contact output or current output
Output 2 (OUT2): No output or relay contact output
*Output type is fixed at the time of order and cannot be changed after purchase.

No output

Relay contact output

Power outages of 20msec or less will not affect operation.

There shall be no corrosive or flammable gas, and there shall be no heavy dust.

100,000 times or more (rated load)

AC 240V 2A (resistive load)
DC 30V 2A (resistive load)

1a contact

Data backup using non-volatile memory
(Number of rewrites: approximately 100,000 times, data storage retention period: approximately 10 years)

1~100 seconds (When set to 0: OFF)

Limit controller

0.5 seconds (switchable to 0.25 seconds)

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Thermocouple: K (JIS/IEC)
0~200℃

-span~+span (within -1999~+9,999digit)

Low voltage directive: EN61010-1
EMC Directive: EN61326-1
RoHS Directive: EN IEC 63000

No optional features

Limit controller SA200L-Part Number-SA200LK01-MN-3*NN-NN/A/03

SA200LK01-MN-3*NN-NN/A/03

Available upon quote

AC/DC 24V

No waterproof/dustproof structure

・FM: FM3545
・UL: UL61010-1
・C-UL:CAN/CSA-C22.2 NO.61010-1

Approximately 110g

No alarm function

No alarm function

5~95%RH (no condensation)
Absolute humidity: MAX.W.C 29.3 g/m3 dry air at 101.3 kPa

-10~+55℃

Thermocouple: ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is greater)

AC24V specifications: maximum 4VA
DC24V specification: max. 100mA

Black tone

2 points (Output 1 (OUT1), Output 2 (OUT2))

Output 1 Limit output (de-energized) Output 2 1st alarm output (energized)

Output 1 (OUT1): Relay contact output or current output
Output 2 (OUT2): No output or relay contact output
*Output type is fixed at the time of order and cannot be changed after purchase.

No output

Relay contact output

Power outages of 20msec or less will not affect operation.

There shall be no corrosive or flammable gas, and there shall be no heavy dust.

100,000 times or more (rated load)

AC 240V 2A (resistive load)
DC 30V 2A (resistive load)

1a contact

Data backup using non-volatile memory
(Number of rewrites: approximately 100,000 times, data storage retention period: approximately 10 years)

1~100 seconds (When set to 0: OFF)

Limit controller

0.5 seconds (switchable to 0.25 seconds)

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Thermocouple: K (JIS/IEC)
0~200℃

-span~+span (within -1999~+9,999digit)

Low voltage directive: EN61010-1
EMC Directive: EN61326-1
RoHS Directive: EN IEC 63000

No optional features

Limit controller SA200L-Part Number-SA200LK01-MN-3*NN-NN/A/04

SA200LK01-MN-3*NN-NN/A/04

Available upon quote

AC/DC 24V

No waterproof/dustproof structure

・FM: FM3545
・UL: UL61010-1
・C-UL:CAN/CSA-C22.2 NO.61010-1

Approximately 110g

No alarm function

No alarm function

5~95%RH (no condensation)
Absolute humidity: MAX.W.C 29.3 g/m3 dry air at 101.3 kPa

-10~+55℃

Thermocouple: ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is greater)

AC24V specifications: maximum 4VA
DC24V specification: max. 100mA

Black tone

2 points (Output 1 (OUT1), Output 2 (OUT2))

Output 1 Limit output (de-energized) Output 2 Logical OR output of 1st and 2nd alarms (de-energized)

Output 1 (OUT1): Relay contact output or current output
Output 2 (OUT2): No output or relay contact output
*Output type is fixed at the time of order and cannot be changed after purchase.

No output

Relay contact output

Power outages of 20msec or less will not affect operation.

There shall be no corrosive or flammable gas, and there shall be no heavy dust.

100,000 times or more (rated load)

AC 240V 2A (resistive load)
DC 30V 2A (resistive load)

1a contact

Data backup using non-volatile memory
(Number of rewrites: approximately 100,000 times, data storage retention period: approximately 10 years)

1~100 seconds (When set to 0: OFF)

Limit controller

0.5 seconds (switchable to 0.25 seconds)

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Thermocouple: K (JIS/IEC)
0~200℃

-span~+span (within -1999~+9,999digit)

Low voltage directive: EN61010-1
EMC Directive: EN61326-1
RoHS Directive: EN IEC 63000

No optional features

Limit controller SA200L-Part Number-SA200LK01-MN-3*NN-NN/A/05

SA200LK01-MN-3*NN-NN/A/05

Available upon quote

AC/DC 24V

No waterproof/dustproof structure

・FM: FM3545
・UL: UL61010-1
・C-UL:CAN/CSA-C22.2 NO.61010-1

Approximately 110g

No alarm function

No alarm function

5~95%RH (no condensation)
Absolute humidity: MAX.W.C 29.3 g/m3 dry air at 101.3 kPa

-10~+55℃

Thermocouple: ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is greater)

AC24V specifications: maximum 4VA
DC24V specification: max. 100mA

Black tone

2 points (Output 1 (OUT1), Output 2 (OUT2))

Output 1 Limit output (de-energized) Output 2 Logic AND output of 1st and 2nd alarms (de-energized)

Output 1 (OUT1): Relay contact output or current output
Output 2 (OUT2): No output or relay contact output
*Output type is fixed at the time of order and cannot be changed after purchase.

No output

Relay contact output

Power outages of 20msec or less will not affect operation.

There shall be no corrosive or flammable gas, and there shall be no heavy dust.

100,000 times or more (rated load)

AC 240V 2A (resistive load)
DC 30V 2A (resistive load)

1a contact

Data backup using non-volatile memory
(Number of rewrites: approximately 100,000 times, data storage retention period: approximately 10 years)

1~100 seconds (When set to 0: OFF)

Limit controller

0.5 seconds (switchable to 0.25 seconds)

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Thermocouple: K (JIS/IEC)
0~200℃

-span~+span (within -1999~+9,999digit)

Low voltage directive: EN61010-1
EMC Directive: EN61326-1
RoHS Directive: EN IEC 63000

No optional features

Limit controller SA200L-Part Number-SA200LK01-MN-3*NN-NN/A/06

SA200LK01-MN-3*NN-NN/A/06

Available upon quote

AC/DC 24V

No waterproof/dustproof structure

・FM: FM3545
・UL: UL61010-1
・C-UL:CAN/CSA-C22.2 NO.61010-1

Approximately 110g

No alarm function

No alarm function

5~95%RH (no condensation)
Absolute humidity: MAX.W.C 29.3 g/m3 dry air at 101.3 kPa

-10~+55℃

Thermocouple: ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is greater)

AC24V specifications: maximum 4VA
DC24V specification: max. 100mA

Black tone

2 points (Output 1 (OUT1), Output 2 (OUT2))

Output 1 Limit output (de-energized) Output 2 1st alarm output (de-energized)

Output 1 (OUT1): Relay contact output or current output
Output 2 (OUT2): No output or relay contact output
*Output type is fixed at the time of order and cannot be changed after purchase.

No output

Relay contact output

Power outages of 20msec or less will not affect operation.

There shall be no corrosive or flammable gas, and there shall be no heavy dust.

100,000 times or more (rated load)

AC 240V 2A (resistive load)
DC 30V 2A (resistive load)

1a contact

Data backup using non-volatile memory
(Number of rewrites: approximately 100,000 times, data storage retention period: approximately 10 years)

1~100 seconds (When set to 0: OFF)

Limit controller

0.5 seconds (switchable to 0.25 seconds)

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Thermocouple: K (JIS/IEC)
0~200℃

-span~+span (within -1999~+9,999digit)

Low voltage directive: EN61010-1
EMC Directive: EN61326-1
RoHS Directive: EN IEC 63000

No optional features

Limit controller SA200L-Part Number-SA200LK01-MN-3*NN-NN/A/07

SA200LK01-MN-3*NN-NN/A/07

Available upon quote

AC/DC 24V

No waterproof/dustproof structure

・FM: FM3545
・UL: UL61010-1
・C-UL:CAN/CSA-C22.2 NO.61010-1

Approximately 110g

No alarm function

No alarm function

5~95%RH (no condensation)
Absolute humidity: MAX.W.C 29.3 g/m3 dry air at 101.3 kPa

-10~+55℃

Thermocouple: ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is greater)

AC24V specifications: maximum 4VA
DC24V specification: max. 100mA

Black tone

2 points (Output 1 (OUT1), Output 2 (OUT2))

Output 1 Limit output (de-energized) Output 2 OFF (OPEN)

Output 1 (OUT1): Relay contact output or current output
Output 2 (OUT2): No output or relay contact output
*Output type is fixed at the time of order and cannot be changed after purchase.

No output

Relay contact output

Power outages of 20msec or less will not affect operation.

There shall be no corrosive or flammable gas, and there shall be no heavy dust.

100,000 times or more (rated load)

AC 240V 2A (resistive load)
DC 30V 2A (resistive load)

1a contact

Data backup using non-volatile memory
(Number of rewrites: approximately 100,000 times, data storage retention period: approximately 10 years)

1~100 seconds (When set to 0: OFF)

Limit controller

0.5 seconds (switchable to 0.25 seconds)

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Thermocouple: K (JIS/IEC)
0~200℃

-span~+span (within -1999~+9,999digit)

Low voltage directive: EN61010-1
EMC Directive: EN61326-1
RoHS Directive: EN IEC 63000

No optional features

Limit controller SA200L-Part Number-SA200LK01-MN-3*NN-NN/A/08

SA200LK01-MN-3*NN-NN/A/08

Available upon quote

AC/DC 24V

No waterproof/dustproof structure

・FM: FM3545
・UL: UL61010-1
・C-UL:CAN/CSA-C22.2 NO.61010-1

Approximately 110g

No alarm function

No alarm function

5~95%RH (no condensation)
Absolute humidity: MAX.W.C 29.3 g/m3 dry air at 101.3 kPa

-10~+55℃

Thermocouple: ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is greater)

AC24V specifications: maximum 4VA
DC24V specification: max. 100mA

Black tone

2 points (Output 1 (OUT1), Output 2 (OUT2))

Output 1 Limit output (excitation) Output 2 Logic OR output of 1st and 2nd alarm (excitation

Output 1 (OUT1): Relay contact output or current output
Output 2 (OUT2): No output or relay contact output
*Output type is fixed at the time of order and cannot be changed after purchase.

No output

Relay contact output

Power outages of 20msec or less will not affect operation.

There shall be no corrosive or flammable gas, and there shall be no heavy dust.

100,000 times or more (rated load)

AC 240V 2A (resistive load)
DC 30V 2A (resistive load)

1a contact

Data backup using non-volatile memory
(Number of rewrites: approximately 100,000 times, data storage retention period: approximately 10 years)

1~100 seconds (When set to 0: OFF)

Limit controller

0.5 seconds (switchable to 0.25 seconds)

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Thermocouple: K (JIS/IEC)
0~200℃

-span~+span (within -1999~+9,999digit)

Low voltage directive: EN61010-1
EMC Directive: EN61326-1
RoHS Directive: EN IEC 63000

No optional features

Limit controller SA200L-Part Number-SA200LK01-MN-3*NN-NN/A/09

SA200LK01-MN-3*NN-NN/A/09

Available upon quote

AC/DC 24V

No waterproof/dustproof structure

・FM: FM3545
・UL: UL61010-1
・C-UL:CAN/CSA-C22.2 NO.61010-1

Approximately 110g

No alarm function

No alarm function

5~95%RH (no condensation)
Absolute humidity: MAX.W.C 29.3 g/m3 dry air at 101.3 kPa

-10~+55℃

Thermocouple: ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is greater)

AC24V specifications: maximum 4VA
DC24V specification: max. 100mA

Black tone

2 points (Output 1 (OUT1), Output 2 (OUT2))

Output 1 Limit output (excitation) Output 2 Logic AND output of 1st and 2nd alarm (excitation)

Output 1 (OUT1): Relay contact output or current output
Output 2 (OUT2): No output or relay contact output
*Output type is fixed at the time of order and cannot be changed after purchase.

No output

Relay contact output

Power outages of 20msec or less will not affect operation.

There shall be no corrosive or flammable gas, and there shall be no heavy dust.

100,000 times or more (rated load)

AC 240V 2A (resistive load)
DC 30V 2A (resistive load)

1a contact

Data backup using non-volatile memory
(Number of rewrites: approximately 100,000 times, data storage retention period: approximately 10 years)

1~100 seconds (When set to 0: OFF)

Limit controller

0.5 seconds (switchable to 0.25 seconds)

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Thermocouple: K (JIS/IEC)
0~200℃

-span~+span (within -1999~+9,999digit)

Low voltage directive: EN61010-1
EMC Directive: EN61326-1
RoHS Directive: EN IEC 63000

No optional features

Limit controller SA200L-Part Number-SA200LK01-MN-3*NN-NN/A/10

SA200LK01-MN-3*NN-NN/A/10

Available upon quote

AC/DC 24V

No waterproof/dustproof structure

・FM: FM3545
・UL: UL61010-1
・C-UL:CAN/CSA-C22.2 NO.61010-1

Approximately 110g

No alarm function

No alarm function

5~95%RH (no condensation)
Absolute humidity: MAX.W.C 29.3 g/m3 dry air at 101.3 kPa

-10~+55℃

Thermocouple: ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is greater)

AC24V specifications: maximum 4VA
DC24V specification: max. 100mA

Black tone

2 points (Output 1 (OUT1), Output 2 (OUT2))

Output 1 Limit output (excitation) Output 2 1st alarm output (excitation)

Output 1 (OUT1): Relay contact output or current output
Output 2 (OUT2): No output or relay contact output
*Output type is fixed at the time of order and cannot be changed after purchase.

No output

Relay contact output

Power outages of 20msec or less will not affect operation.

There shall be no corrosive or flammable gas, and there shall be no heavy dust.

100,000 times or more (rated load)

AC 240V 2A (resistive load)
DC 30V 2A (resistive load)

1a contact

Data backup using non-volatile memory
(Number of rewrites: approximately 100,000 times, data storage retention period: approximately 10 years)

1~100 seconds (When set to 0: OFF)

Limit controller

0.5 seconds (switchable to 0.25 seconds)

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Thermocouple: K (JIS/IEC)
0~200℃

-span~+span (within -1999~+9,999digit)

Low voltage directive: EN61010-1
EMC Directive: EN61326-1
RoHS Directive: EN IEC 63000

No optional features

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Temperature Controllers Products

Other products of RKC INSTRUMENT

Reviews shown here are reviews of companies.


View more products of RKC INSTRUMENT

About Company Handling This Product

Response Rate

100.0%


Response Time

14.3hrs

Company Overview

RKC Instrument has been continually growing for over half a century and strives to be a solution provider of m...

See More

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree