All Categories

History

Ethernet communication converter COM-ML series-COM-ML44*02
Ethernet communication converter COM-ML series-RKC INSTRUMENT

Ethernet communication converter COM-ML series
RKC INSTRUMENT

RKC INSTRUMENT's Response Status

Response Rate

100.0%

Response Time

9.8hours

Fast Response


About This Product

Easily connect the controller to an Ethernet network.

■COM-ML-1

・COM-ML-1 is a communication converter for connecting the module type controller SRZ to Ethernet [MODBUS/TCP or PLC communication (MAPMAN)]. ・Compatible controller: SRZ (Z-TIO-A/B/C/D, Z-DIO, Z-CT) ・MAPMAN compatible PLC: Mitsubishi Electric QnA compatible 3E frame/SLMP ASCII or binary

■COM-ML-2

・COM-ML-2 is a communication converter for connecting the module type controller SRZ to EtherNet/IP. ・Compatible controller: SRZ (Z-TIO-A/B, Z-DIO)

■COM-ML-3

・COM-ML-3 is a communication converter for connecting the module type controller SRZ to EtherCAT. ・Compatible controller: SRZ (Z-TIO-A/B, Z-DIO)

■COM-ML-4 PROFINET communication converter

・A communication converter for connecting our SRZ series to PROFINET. ・Connectable models: SRZ (Z-TIO-A / Z-TIO-B, Z-DIO) *Other product numbers are available.

  • Product

    Ethernet communication converter COM-ML series

Share this product


280+ people viewing

Last viewed: 4 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Ethernet communication converter COM-ML series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Power supply voltage Mass Permissible ambient humidity Permissible ambient temperature Inrush current Physical layer Power consumption Compatible models Number of supported channels Factory settings Loader communication communication speed Loader communication Maximum number of connection points Loader communication connection method Loader communication protocol Loader communication data format Host communication communication speed Host communication terminating resistor Host communication Maximum number of connection points Host communication protocol Host communication bit configuration Host communication interface Host communication interval time Host communication Network communication protocol Network Connector
Ethernet communication converter COM-ML series-Part Number-COM-ML44*02

COM-ML44*02

Available upon quote

DC21.6~26.4V (including power supply voltage fluctuation) Rating: DC 24V

Approximately 130g

5~95%RH
Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa

-10~+50℃

12A or less

100BASE-TX

Max 120mA

SRZ

No factory settings for communication protocols

None (no communication protocol factory settings)

38,400 bps

1 point

Connected by special loader cable

RKC standard communication
Compliant with ANSI X3.28-1976 subcategory 2.5B1

Start bit: 1, data bit: 8, parity bit: none, stop bit: 1

4,800 bps, 9,600 bps, 19,200 bps, 38,400 bps

Requires external connection

16 points

RKC standard communication
ANSI X3.28-1976 subcategory 2.5B1 compliant
MODBUS-RTU

Start bit: 1
Data bits: 7 or 8 (MODBUS is fixed at 8 bits)
Parity bit: None/Yes (odd or even)
Stop bit: 1

EIA standard RS-485 compliant, EIA standard RS-422A compliant

0~250ms

RS-422A

No factory settings for communication protocols

PROFINET

RJ-45 x 2 ports

Ethernet communication converter COM-ML series-Part Number-COM-ML45*02

COM-ML45*02

Available upon quote

DC21.6~26.4V (including power supply voltage fluctuation) Rating: DC 24V

Approximately 130g

5~95%RH
Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa

-10~+50℃

12A or less

100BASE-TX

Max 120mA

SRZ

No factory settings for communication protocols

None (no communication protocol factory settings)

38,400 bps

1 point

Connected by special loader cable

RKC standard communication
Compliant with ANSI X3.28-1976 subcategory 2.5B1

Start bit: 1, data bit: 8, parity bit: none, stop bit: 1

4,800 bps, 9,600 bps, 19,200 bps, 38,400 bps

Requires external connection

16 points

RKC standard communication
ANSI X3.28-1976 subcategory 2.5B1 compliant
MODBUS-RTU

Start bit: 1
Data bits: 7 or 8 (MODBUS is fixed at 8 bits)
Parity bit: None/Yes (odd or even)
Stop bit: 1

EIA standard RS-485 compliant, EIA standard RS-422A compliant

0~250ms

RS-485

No factory settings for communication protocols

PROFINET

RJ-45 x 2 ports

Ethernet communication converter COM-ML series-Part Number-COM-ML14*02

COM-ML14*02

Available upon quote

DC21.6~26.4V (including power supply voltage fluctuation) Rating: DC 24V

Approximately 130g

5~95%RH
Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa

-10~+50℃

12A or less

10BASE-T/100BASE-TX automatic recognition

Max 120mA

SRZ

No factory settings for communication protocols

None (no communication protocol factory settings)

38,400 bps

1 point

Connected by special loader cable

RKC standard communication
Compliant with ANSI X3.28-1976 subcategory 2.5B1

Start bit: 1, data bit: 8, parity bit: none, stop bit: 1

4,800 bps, 9,600 bps, 19,200 bps, 38,400 bps

Requires external connection

16 points

RKC standard communication
ANSI X3.28-1976 subcategory 2.5B1 compliant
MODBUS-RTU

Start bit: 1
Data bits: 7 or 8 (MODBUS is fixed at 8 bits)
Parity bit: None/Yes (odd or even)
Stop bit: 1

EIA standard RS-485 compliant, EIA standard RS-422A compliant

0~250ms

RS-422A

No factory settings for communication protocols

Ethernet [MODBUS/TCP・Ethernet MAPMAN]

RJ-45 x 2 ports

Ethernet communication converter COM-ML series-Part Number-COM-ML15*02

COM-ML15*02

Available upon quote

DC21.6~26.4V (including power supply voltage fluctuation) Rating: DC 24V

Approximately 130g

5~95%RH
Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa

-10~+50℃

12A or less

10BASE-T/100BASE-TX automatic recognition

Max 120mA

SRZ

No factory settings for communication protocols

None (no communication protocol factory settings)

38,400 bps

1 point

Connected by special loader cable

RKC standard communication
Compliant with ANSI X3.28-1976 subcategory 2.5B1

Start bit: 1, data bit: 8, parity bit: none, stop bit: 1

4,800 bps, 9,600 bps, 19,200 bps, 38,400 bps

Requires external connection

16 points

RKC standard communication
ANSI X3.28-1976 subcategory 2.5B1 compliant
MODBUS-RTU

Start bit: 1
Data bits: 7 or 8 (MODBUS is fixed at 8 bits)
Parity bit: None/Yes (odd or even)
Stop bit: 1

EIA standard RS-485 compliant, EIA standard RS-422A compliant

0~250ms

RS-485

No factory settings for communication protocols

Ethernet [MODBUS/TCP・Ethernet MAPMAN]

RJ-45 x 2 ports

Ethernet communication converter COM-ML series-Part Number-COM-ML24*02

COM-ML24*02

Available upon quote

DC21.6~26.4V (including power supply voltage fluctuation) Rating: DC 24V

Approximately 130g

5~95%RH
Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa

-10~+50℃

12A or less

10BASE-T/100BASE-TX automatic recognition

Max 120mA

SRZ

No factory settings for communication protocols

None (no communication protocol factory settings)

38,400 bps

1 point

Connected by special loader cable

RKC standard communication
Compliant with ANSI X3.28-1976 subcategory 2.5B1

Start bit: 1, data bit: 8, parity bit: none, stop bit: 1

4,800 bps, 9,600 bps, 19,200 bps, 38,400 bps

Requires external connection

16 points

RKC standard communication
ANSI X3.28-1976 subcategory 2.5B1 compliant
MODBUS-RTU

Start bit: 1
Data bits: 7 or 8 (MODBUS is fixed at 8 bits)
Parity bit: None/Yes (odd or even)
Stop bit: 1

EIA standard RS-485 compliant, EIA standard RS-422A compliant

0~250ms

RS-422A

No factory settings for communication protocols

EtherNet/IP

RJ-45

Ethernet communication converter COM-ML series-Part Number-COM-ML25*02

COM-ML25*02

Available upon quote

DC21.6~26.4V (including power supply voltage fluctuation) Rating: DC 24V

Approximately 130g

5~95%RH
Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa

-10~+50℃

12A or less

10BASE-T/100BASE-TX automatic recognition

Max 120mA

SRZ

No factory settings for communication protocols

None (no communication protocol factory settings)

38,400 bps

1 point

Connected by special loader cable

RKC standard communication
Compliant with ANSI X3.28-1976 subcategory 2.5B1

Start bit: 1, data bit: 8, parity bit: none, stop bit: 1

4,800 bps, 9,600 bps, 19,200 bps, 38,400 bps

Requires external connection

16 points

RKC standard communication
ANSI X3.28-1976 subcategory 2.5B1 compliant
MODBUS-RTU

Start bit: 1
Data bits: 7 or 8 (MODBUS is fixed at 8 bits)
Parity bit: None/Yes (odd or even)
Stop bit: 1

EIA standard RS-485 compliant, EIA standard RS-422A compliant

0~250ms

RS-485

No factory settings for communication protocols

EtherNet/IP

RJ-45

Ethernet communication converter COM-ML series-Part Number-COM-ML34*02

COM-ML34*02

Available upon quote

DC21.6~26.4V (including power supply voltage fluctuation) Rating: DC 24V

Approximately 130g

5~95%RH
Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa

-10~+50℃

12A or less

100BASE-TX

Max 120mA

SRZ

No factory settings for communication protocols

None (no communication protocol factory settings)

38,400 bps

1 point

Connected by special loader cable

RKC standard communication
Compliant with ANSI X3.28-1976 subcategory 2.5B1

Start bit: 1, data bit: 8, parity bit: none, stop bit: 1

4,800 bps, 9,600 bps, 19,200 bps, 38,400 bps

Requires external connection

16 points

RKC standard communication
ANSI X3.28-1976 subcategory 2.5B1 compliant
MODBUS-RTU

Start bit: 1
Data bits: 7 or 8 (MODBUS is fixed at 8 bits)
Parity bit: None/Yes (odd or even)
Stop bit: 1

EIA standard RS-485 compliant, EIA standard RS-422A compliant

0~250ms

RS-422A

No factory settings for communication protocols

EtherCAT

RJ-45 x 2 ports

Ethernet communication converter COM-ML series-Part Number-COM-ML35*02

COM-ML35*02

Available upon quote

DC21.6~26.4V (including power supply voltage fluctuation) Rating: DC 24V

Approximately 130g

5~95%RH
Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa

-10~+50℃

12A or less

100BASE-TX

Max 120mA

SRZ

No factory settings for communication protocols

None (no communication protocol factory settings)

38,400 bps

1 point

Connected by special loader cable

RKC standard communication
Compliant with ANSI X3.28-1976 subcategory 2.5B1

Start bit: 1, data bit: 8, parity bit: none, stop bit: 1

4,800 bps, 9,600 bps, 19,200 bps, 38,400 bps

Requires external connection

16 points

RKC standard communication
ANSI X3.28-1976 subcategory 2.5B1 compliant
MODBUS-RTU

Start bit: 1
Data bits: 7 or 8 (MODBUS is fixed at 8 bits)
Parity bit: None/Yes (odd or even)
Stop bit: 1

EIA standard RS-485 compliant, EIA standard RS-422A compliant

0~250ms

RS-485

No factory settings for communication protocols

EtherCAT

RJ-45 x 2 ports

Ethernet communication converter COM-ML series-Part Number-COM-ML14*02/111A

COM-ML14*02/111A

Available upon quote

DC21.6~26.4V (including power supply voltage fluctuation) Rating: DC 24V

Approximately 130g

5~95%RH
Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa

-10~+50℃

12A or less

10BASE-T/100BASE-TX automatic recognition

Max 120mA

SRZ

16 channels

Communication protocol is set at the factory

38,400 bps

1 point

Connected by special loader cable

RKC standard communication
Compliant with ANSI X3.28-1976 subcategory 2.5B1

Start bit: 1, data bit: 8, parity bit: none, stop bit: 1

4,800 bps, 9,600 bps, 19,200 bps, 38,400 bps

Requires external connection

16 points

RKC standard communication
ANSI X3.28-1976 subcategory 2.5B1 compliant
MODBUS-RTU

Start bit: 1
Data bits: 7 or 8 (MODBUS is fixed at 8 bits)
Parity bit: None/Yes (odd or even)
Stop bit: 1

EIA standard RS-485 compliant, EIA standard RS-422A compliant

0~250ms

RS-422A

MODBUS/TCP

Ethernet [MODBUS/TCP・Ethernet MAPMAN]

RJ-45 x 2 ports

Ethernet communication converter COM-ML series-Part Number-COM-ML14*02/111B

COM-ML14*02/111B

Available upon quote

DC21.6~26.4V (including power supply voltage fluctuation) Rating: DC 24V

Approximately 130g

5~95%RH
Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa

-10~+50℃

12A or less

10BASE-T/100BASE-TX automatic recognition

Max 120mA

SRZ

32 channels

Communication protocol is set at the factory

38,400 bps

1 point

Connected by special loader cable

RKC standard communication
Compliant with ANSI X3.28-1976 subcategory 2.5B1

Start bit: 1, data bit: 8, parity bit: none, stop bit: 1

4,800 bps, 9,600 bps, 19,200 bps, 38,400 bps

Requires external connection

16 points

RKC standard communication
ANSI X3.28-1976 subcategory 2.5B1 compliant
MODBUS-RTU

Start bit: 1
Data bits: 7 or 8 (MODBUS is fixed at 8 bits)
Parity bit: None/Yes (odd or even)
Stop bit: 1

EIA standard RS-485 compliant, EIA standard RS-422A compliant

0~250ms

RS-422A

MODBUS/TCP

Ethernet [MODBUS/TCP・Ethernet MAPMAN]

RJ-45 x 2 ports

Click on the part number for more information about each product

Other products of RKC INSTRUMENT

Reviews shown here are reviews of companies.


View more products of RKC INSTRUMENT

About Company Handling This Product

Response Rate

100.0%


Response Time

9.8hrs

Company Overview

RKC Instrument has been continually growing for over half a century and strives to be a solution provider of m...

See More

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree