All Categories

History

Ethernet communication converter COM-ME series-COM-ME-15*02
Ethernet communication converter COM-ME series-RKC INSTRUMENT

Ethernet communication converter COM-ME series
RKC INSTRUMENT

RKC INSTRUMENT's Response Status

Response Rate

100.0%

Response Time

15.5hours

Relatively Fast Response


About This Product

■COM-ME-1 Ethernet (MODBUS/TCP) communication converter

・A communication converter for connecting our SRZ series, FZ series, and GZ series to Ethernet (MODBUS/TCP). ・Modular controller SRZ (up to 16 units for Z-TIO-A: maximum temperature control 64 channels) can be connected to Ethernet. ・Up to 31 units for digital indication controller FZ/GZ: Up to 32 temperature control channels can be connected to Ethernet.

■COM-ME-2 Ethernet (EtherNet/IP) communication converter

・A communication converter for connecting our SRZ series to Ethernet (EtherNet/IP). ・Modular controller SRZ (up to 16 units for Z-TIO-A: maximum temperature control 64 channels) can be connected to Ethernet.

■COM-ME-3 Ethernet (EtherCAT) communication converter

・A communication converter for connecting our SRZ series, FZ series, and GZ series to EtherCAT. ・Modular controller SRZ (up to 16 units for Z-TIO-A: maximum temperature control 64 channels) can be connected to EtherCAT. - Up to 31 digital indicator controllers FZ/GZ: Up to 32 temperature control channels can be connected to EtherCAT.

■COM-ME-6 Ethernet (Ethernet MAPMAN) communication converter

・A communication converter for connecting our SRZ series to Ethernet. ・Program-less connection with Mitsubishi Electric PLC is possible using PLC-specific protocol communication. ・Modular controller SRZ (up to 16 units for Z-TIO-A: maximum temperature control 64 channels) can be connected to Ethernet.

■Communication speed

9,600bps, 19,200bps, 38,400bps, 57,600bps *When using host communication at 57,600bps, set the connected function module to 38,400bps and set the protocol to MODBUS. *Other product numbers are available.

  • Product

    Ethernet communication converter COM-ME series

Share this product


390+ people viewing

Last viewed: 1 hour ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Ethernet communication converter COM-ME series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Power supply Electrical standards Compatible standards Mass Permissible ambient humidity Permissible ambient temperature Momentary power outage Physical layer Power consumption Maximum number of connection points Connection method Compatible models Safety standards Factory settings Data protection during power outages Loader communication specifications Communication speed Loader communication specifications Maximum number of connection points Loader communication specifications Connection method Host communication protocol Host communication Network Subnet mask Connector specifications Address settings IP address
Ethernet communication converter COM-ME series-Part Number-COM-ME-15*02

COM-ME-15*02

Available upon quote

DC24V

EIA RS-485 compliant
*Multi-drop connection possible

CE marking (EMC directive: EN61326-1, RoHS directive: EN IEC 63000)
RCM: EN55011

Approximately 150g

5~95%RH
(Absolute humidity: MAX.W.C 29g/m3 dry air at 101.3kPa)

-10~+55℃

Operation is not affected by power outages of 4 milliseconds or less

100BASE-TX

Maximum 150mA (Inrush current: 15A or less)

Max. 30 units (Z-TIO (max. 16 units) +Z-DIO+Z-CT maximum number

Terminal block

SRZ series (Z-TIO-A/Z-TIO-B/Z-DIO/Z-CT)

UL: UL61010-1
cUL︓CAN/CSA-C22.2 No.61010-1

None (no communication protocol specified at the factory)

Data backup using non-volatile memory
Number of rewrites: Approximately 1 million times
Data storage retention period: Approximately 10 years

38,400bps

1 point

Connected with a dedicated loader cable

RKC communication

RS-485

MODBUS/TCP

0.0.0.0~255.255.255.255

RJ-45 x 2 ports

0~99

0.0.0.0~255.255.255.255
*Local loopback addresses (127.0.0.1~127.255.255.254) cannot be used.

Ethernet communication converter COM-ME series-Part Number-COM-ME-15*02/11

COM-ME-15*02/11

Available upon quote

DC24V

EIA RS-485 compliant
*Multi-drop connection possible

CE marking (EMC directive: EN61326-1, RoHS directive: EN IEC 63000)
RCM: EN55011

Approximately 150g

5~95%RH
(Absolute humidity: MAX.W.C 29g/m3 dry air at 101.3kPa)

-10~+55℃

Operation is not affected by power outages of 4 milliseconds or less

100BASE-TX

Maximum 150mA (Inrush current: 15A or less)

Max. 30 units (Z-TIO (max. 16 units) +Z-DIO+Z-CT maximum number

Terminal block

SRZ series (Z-TIO-A/Z-TIO-B/Z-DIO/Z-CT)

UL: UL61010-1
cUL︓CAN/CSA-C22.2 No.61010-1

Communication protocol specified at time of shipment

Data backup using non-volatile memory
Number of rewrites: Approximately 1 million times
Data storage retention period: Approximately 10 years

38,400bps

1 point

Connected with a dedicated loader cable

RKC communication

RS-485

MODBUS/TCP

0.0.0.0~255.255.255.255

RJ-45 x 2 ports

0~99

0.0.0.0~255.255.255.255
*Local loopback addresses (127.0.0.1~127.255.255.254) cannot be used.

Ethernet communication converter COM-ME series-Part Number-COM-ME-15*02/12

COM-ME-15*02/12

Available upon quote

DC24V

EIA RS-485 compliant
*Multi-drop connection possible

CE marking (EMC directive: EN61326-1, RoHS directive: EN IEC 63000)
RCM: EN55011

Approximately 150g

5~95%RH
(Absolute humidity: MAX.W.C 29g/m3 dry air at 101.3kPa)

-10~+55℃

Operation is not affected by power outages of 4 milliseconds or less

100BASE-TX

Maximum 150mA (Inrush current: 15A or less)

Max. 30 units (Z-TIO (max. 16 units) +Z-DIO+Z-CT maximum number

Terminal block

SRZ series (Z-TIO-A/Z-TIO-B/Z-DIO/Z-CT)

UL: UL61010-1
cUL︓CAN/CSA-C22.2 No.61010-1

Communication protocol specified at time of shipment

Data backup using non-volatile memory
Number of rewrites: Approximately 1 million times
Data storage retention period: Approximately 10 years

38,400bps

1 point

Connected with a dedicated loader cable

MODBUS communication

RS-485

MODBUS/TCP

0.0.0.0~255.255.255.255

RJ-45 x 2 ports

01h~FFh

0.0.0.0~255.255.255.255
*Local loopback addresses (127.0.0.1~127.255.255.254) cannot be used.

Ethernet communication converter COM-ME series-Part Number-COM-ME-15*07

COM-ME-15*07

Available upon quote

DC24V

EIA RS-485 compliant
*Multi-drop connection possible

CE marking (EMC directive: EN61326-1, RoHS directive: EN IEC 63000)
RCM: EN55011

Approximately 150g

5~95%RH
(Absolute humidity: MAX.W.C 29g/m3 dry air at 101.3kPa)

-10~+55℃

Operation is not affected by power outages of 4 milliseconds or less

100BASE-TX

Maximum 150mA (Inrush current: 15A or less)

Maximum 31 units

Terminal block

FZ110 / FZ400 / FZ900, GZ400 / GZ900

UL: UL61010-1
cUL︓CAN/CSA-C22.2 No.61010-1

-

Data backup using non-volatile memory
Number of rewrites: Approximately 1 million times
Data storage retention period: Approximately 10 years

38,400bps

1 point

Connected with a dedicated loader cable

-

RS-485

MODBUS/TCP

0.0.0.0~255.255.255.255

RJ-45 x 2 ports

RKC standard communication: 0~99
MODBUS communication: 01h~FFh

0.0.0.0~255.255.255.255
*Local loopback addresses (127.0.0.1~127.255.255.254) cannot be used.

Ethernet communication converter COM-ME series-Part Number-COM-ME-25*02

COM-ME-25*02

Available upon quote

DC24V

EIA RS-485 compliant
*Multi-drop connection possible

CE marking (EMC: EN61326-1, RoHS: EN IEC 63000)
RCM: EN55011

Approximately 150g

5~95%RH
(Absolute humidity: MAX.W.C 29g/m3 dry air at 101.3kPa)

-10~+55℃

Operation is not affected by power outages of 4 milliseconds or less

10BASE-T/100BASE-TX automatic recognition

Maximum 150mA (Inrush current: 15A or less)

Max. 30 units (Z-TIO (max. 16 units) +Z-DIO+Z-CT maximum number

Terminal block

SRZ series (Z-TIO-A/Z-TIO-B/Z-DIO/Z-CT)

UL: UL61010-1
cUL︓CAN/CSA-C22.2 No.61010-1

None (no communication protocol specified at the factory)

Data backup using non-volatile memory
Number of rewrites: Approximately 1 million times
Data storage retention period: Approximately 10 years

38,400bps

1 point

Connected with a dedicated loader cable

RKC communication

RS-485

EtherNet/IP

0.0.0.0~255.255.255.255

RJ-45 x 2 ports

0~99

0.0.0.0~255.255.255.255
*1 Do not set it to the loopback address (127.0.0.1).

Ethernet communication converter COM-ME series-Part Number-COM-ME-25*02/11

COM-ME-25*02/11

Available upon quote

DC24V

EIA RS-485 compliant
*Multi-drop connection possible

CE marking (EMC: EN61326-1, RoHS: EN IEC 63000)
RCM: EN55011

Approximately 150g

5~95%RH
(Absolute humidity: MAX.W.C 29g/m3 dry air at 101.3kPa)

-10~+55℃

Operation is not affected by power outages of 4 milliseconds or less

10BASE-T/100BASE-TX automatic recognition

Maximum 150mA (Inrush current: 15A or less)

Max. 30 units (Z-TIO (max. 16 units) +Z-DIO+Z-CT maximum number

Terminal block

SRZ series (Z-TIO-A/Z-TIO-B/Z-DIO/Z-CT)

UL: UL61010-1
cUL︓CAN/CSA-C22.2 No.61010-1

Communication protocol specified at time of shipment

Data backup using non-volatile memory
Number of rewrites: Approximately 1 million times
Data storage retention period: Approximately 10 years

38,400bps

1 point

Connected with a dedicated loader cable

RKC communication

RS-485

EtherNet/IP

0.0.0.0~255.255.255.255

RJ-45 x 2 ports

0~99

0.0.0.0~255.255.255.255
*1 Do not set it to the loopback address (127.0.0.1).

Ethernet communication converter COM-ME series-Part Number-COM-ME-25*02/12

COM-ME-25*02/12

Available upon quote

DC24V

EIA RS-485 compliant
*Multi-drop connection possible

CE marking (EMC: EN61326-1, RoHS: EN IEC 63000)
RCM: EN55011

Approximately 150g

5~95%RH
(Absolute humidity: MAX.W.C 29g/m3 dry air at 101.3kPa)

-10~+55℃

Operation is not affected by power outages of 4 milliseconds or less

10BASE-T/100BASE-TX automatic recognition

Maximum 150mA (Inrush current: 15A or less)

Max. 30 units (Z-TIO (max. 16 units) +Z-DIO+Z-CT maximum number

Terminal block

SRZ series (Z-TIO-A/Z-TIO-B/Z-DIO/Z-CT)

UL: UL61010-1
cUL︓CAN/CSA-C22.2 No.61010-1

Communication protocol specified at time of shipment

Data backup using non-volatile memory
Number of rewrites: Approximately 1 million times
Data storage retention period: Approximately 10 years

38,400bps

1 point

Connected with a dedicated loader cable

MODBUS communication

RS-485

EtherNet/IP

0.0.0.0~255.255.255.255

RJ-45 x 2 ports

01h~FFh

0.0.0.0~255.255.255.255
*1 Do not set it to the loopback address (127.0.0.1).

Ethernet communication converter COM-ME series-Part Number-COM-ME-35*02

COM-ME-35*02

Available upon quote

DC24V

EIA RS-485 compliant
*Multi-drop connection possible

CE marking (EMC directive: EN61326-1, RoHS directive: EN IEC 63000)
RCM: EN55011

Approximately 150g

5~95%RH
(Absolute humidity: MAX.W.C 29g/m3 dry air at 101.3kPa)

-10~+55℃

Operation is not affected by power outages of 4 milliseconds or less

100BASE-TX

Maximum 150mA (Inrush current: 15A or less)

Max. 30 units (Z-TIO (max. 16 units) +Z-DIO+Z-CT maximum number

Terminal block

SRZ series (Z-TIO-A / Z-TIO-B / Z-DIO / Z-CT)

UL: UL61010-1
cUL︓CAN/CSA-C22.2 No.61010-1

-

Data backup using non-volatile memory
Number of rewrites: Approximately 1 million times
Data storage retention period: Approximately 10 years

38,400bps

1 point

Connected with a dedicated loader cable

-

RS-485

EtherCAT

-

RJ-45 x 2 ports

RKC standard communication: 0~99
MODBUS communication: 01h~FFh

-
Ethernet communication converter COM-ME series-Part Number-COM-ME-35*07

COM-ME-35*07

Available upon quote

DC24V

EIA RS-485 compliant
*Multi-drop connection possible

CE marking (EMC directive: EN61326-1, RoHS directive: EN IEC 63000)
RCM: EN55011

Approximately 150g

5~95%RH
(Absolute humidity: MAX.W.C 29g/m3 dry air at 101.3kPa)

-10~+55℃

Operation is not affected by power outages of 4 milliseconds or less

100BASE-TX

Maximum 150mA (Inrush current: 15A or less)

Maximum 31 units

Terminal block

FZ110 / FZ400 / FZ900, GZ400 / GZ900

UL: UL61010-1
cUL︓CAN/CSA-C22.2 No.61010-1

None (no communication mode factory setting)

Data backup using non-volatile memory
Number of rewrites: Approximately 1 million times
Data storage retention period: Approximately 10 years

38,400bps

1 point

Connected with a dedicated loader cable

-

RS-485

EtherCAT

-

RJ-45 x 2 ports

RKC standard communication: 0~99
MODBUS communication: 01h~FFh

-
Ethernet communication converter COM-ME series-Part Number-COM-ME-65*02

COM-ME-65*02

Available upon quote

DC24V

EIA RS-485 compliant
*Multi-drop connection possible

CE marking (EMC directive: EN61326-1, RoHS directive: EN IEC 63000)
RCM: EN55011

Approximately 150g

5~95%RH
(Absolute humidity: MAX.W.C 29g/m3 dry air at 101.3kPa)

-10~+55℃

Operation is not affected by power outages of 4 milliseconds or less

10BASE-T/100BASE-TX automatic recognition
*However, daisy chain connection is only possible with 100BASE-TX.

Maximum 150mA (Inrush current: 15A or less)

31 points (maximum 30 for SRZ)

Terminal block

SRZ series (Z-TIO-A / Z-TIO-B / Z-DIO / Z-CT)

UL: UL61010-1
cUL︓CAN/CSA-C22.2 No.61010-1

None (no communication protocol specified at the factory)

Data backup using non-volatile memory
Number of rewrites: Approximately 1 million times
Data storage retention period: Approximately 10 years

38,400bps

1 point

Connected with a dedicated loader cable

RKC communication

RS-485

Ether MAPMAN

0.0.0.0~255.255.255.255

RJ-45 x 2 ports

0~99

0.0.0.0~255.255.255.255
*Local loopback addresses (127.0.0.1~127.255.255.254) cannot be used.

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Fieldbus Components Products

Other products of RKC INSTRUMENT

Reviews shown here are reviews of companies.


View more products of RKC INSTRUMENT

About Company Handling This Product

Response Rate

100.0%


Response Time

15.5hrs

Company Overview

RKC Instrument has been continually growing for over half a century and strives to be a solution provider of m...

See More

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree