All Categories
History
Response Rate
100.0%
Response Time
15.5hours
Relatively Fast Response
Product
Modular controller (process/temperature controller) SRXHandling Company
RKC INSTRUMENTCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply voltage | Mass | Permissible ambient temperature | Influence of permissible input conductors | Withstand voltage | Insulation resistance | Integral time (I) | Measuring input (channel 2) | Measuring input (channel 1) | Current consumption | Proportional period | Differential time (D) | Control method | Control response | Control output 2 (channel 2) | Control output 1 (channel 1) | Control setting range Proportional band (P) | Output change rate limiter | Output limiter | Number of input points | Operation when input is disconnected | Input digital filter | Effects of power outage | Effect of signal source resistance | Level PID | Type | Sampling period | PV bias | CT input 2 (CT input of channel 2) | CT input 1 (CT input of channel 1) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
X-TIO-A-KK-MM*NN |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
220g |
-10~50℃ |
Maximum 10Ω per wire (resistance temperature detector input) |
AC 600V for 1 minute between each insulation block |
Between each insulation block DC 500V 20MΩ or more |
0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable) |
Input type: K |
Input type: K |
120mA or less |
0.2~50.0 seconds |
0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable) |
Brilliant PID control (with auto tuning function) |
Slow, Medium, Fast |
Relay contact output |
Relay contact output |
During temperature input 0~input span (℃) |
0.0~100.0%/sec |
-5.0~+105.0% (set by upper and lower limits) |
2 points (channel-to-channel isolation) |
Upscale |
0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds) |
No effect on power outages of 20ms or less |
0.25μV/Ω (thermocouple input) |
Select 8 types of PID parameters depending on the position of the set value |
Basic type |
0.025 seconds |
±input range span |
No CT input |
No CT input |
|
X-TIO-A-KK-MM*NP |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
220g |
-10~50℃ |
Maximum 10Ω per wire (resistance temperature detector input) |
AC 600V for 1 minute between each insulation block |
Between each insulation block DC 500V 20MΩ or more |
0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable) |
Input type: K |
Input type: K |
120mA or less |
0.2~50.0 seconds |
0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable) |
Brilliant PID control (with auto tuning function) |
Slow, Medium, Fast |
Relay contact output |
Relay contact output |
During temperature input 0~input span (℃) |
0.0~100.0%/sec |
-5.0~+105.0% (set by upper and lower limits) |
2 points (channel-to-channel isolation) |
Upscale |
0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds) |
No effect on power outages of 20ms or less |
0.25μV/Ω (thermocouple input) |
Select 8 types of PID parameters depending on the position of the set value |
Basic type |
0.025 seconds |
±input range span |
Using CTL-6-P-N |
No CT input |
|
X-TIO-A-KK-MM*NS |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
220g |
-10~50℃ |
Maximum 10Ω per wire (resistance temperature detector input) |
AC 600V for 1 minute between each insulation block |
Between each insulation block DC 500V 20MΩ or more |
0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable) |
Input type: K |
Input type: K |
120mA or less |
0.2~50.0 seconds |
0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable) |
Brilliant PID control (with auto tuning function) |
Slow, Medium, Fast |
Relay contact output |
Relay contact output |
During temperature input 0~input span (℃) |
0.0~100.0%/sec |
-5.0~+105.0% (set by upper and lower limits) |
2 points (channel-to-channel isolation) |
Upscale |
0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds) |
No effect on power outages of 20ms or less |
0.25μV/Ω (thermocouple input) |
Select 8 types of PID parameters depending on the position of the set value |
Basic type |
0.025 seconds |
±input range span |
Using CTL-12-S56-10L-N |
No CT input |
|
X-TIO-A-KK-MM*PN |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
220g |
-10~50℃ |
Maximum 10Ω per wire (resistance temperature detector input) |
AC 600V for 1 minute between each insulation block |
Between each insulation block DC 500V 20MΩ or more |
0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable) |
Input type: K |
Input type: K |
120mA or less |
0.2~50.0 seconds |
0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable) |
Brilliant PID control (with auto tuning function) |
Slow, Medium, Fast |
Relay contact output |
Relay contact output |
During temperature input 0~input span (℃) |
0.0~100.0%/sec |
-5.0~+105.0% (set by upper and lower limits) |
2 points (channel-to-channel isolation) |
Upscale |
0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds) |
No effect on power outages of 20ms or less |
0.25μV/Ω (thermocouple input) |
Select 8 types of PID parameters depending on the position of the set value |
Basic type |
0.025 seconds |
±input range span |
No CT input |
Using CTL-6-P-N |
|
X-TIO-A-KK-MM*PP |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
220g |
-10~50℃ |
Maximum 10Ω per wire (resistance temperature detector input) |
AC 600V for 1 minute between each insulation block |
Between each insulation block DC 500V 20MΩ or more |
0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable) |
Input type: K |
Input type: K |
120mA or less |
0.2~50.0 seconds |
0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable) |
Brilliant PID control (with auto tuning function) |
Slow, Medium, Fast |
Relay contact output |
Relay contact output |
During temperature input 0~input span (℃) |
0.0~100.0%/sec |
-5.0~+105.0% (set by upper and lower limits) |
2 points (channel-to-channel isolation) |
Upscale |
0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds) |
No effect on power outages of 20ms or less |
0.25μV/Ω (thermocouple input) |
Select 8 types of PID parameters depending on the position of the set value |
Basic type |
0.025 seconds |
±input range span |
Using CTL-6-P-N |
Using CTL-6-P-N |
|
X-TIO-A-KK-MM*PS |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
220g |
-10~50℃ |
Maximum 10Ω per wire (resistance temperature detector input) |
AC 600V for 1 minute between each insulation block |
Between each insulation block DC 500V 20MΩ or more |
0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable) |
Input type: K |
Input type: K |
120mA or less |
0.2~50.0 seconds |
0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable) |
Brilliant PID control (with auto tuning function) |
Slow, Medium, Fast |
Relay contact output |
Relay contact output |
During temperature input 0~input span (℃) |
0.0~100.0%/sec |
-5.0~+105.0% (set by upper and lower limits) |
2 points (channel-to-channel isolation) |
Upscale |
0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds) |
No effect on power outages of 20ms or less |
0.25μV/Ω (thermocouple input) |
Select 8 types of PID parameters depending on the position of the set value |
Basic type |
0.025 seconds |
±input range span |
Using CTL-12-S56-10L-N |
Using CTL-6-P-N |
|
X-TIO-A-KK-MM*SN |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
220g |
-10~50℃ |
Maximum 10Ω per wire (resistance temperature detector input) |
AC 600V for 1 minute between each insulation block |
Between each insulation block DC 500V 20MΩ or more |
0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable) |
Input type: K |
Input type: K |
120mA or less |
0.2~50.0 seconds |
0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable) |
Brilliant PID control (with auto tuning function) |
Slow, Medium, Fast |
Relay contact output |
Relay contact output |
During temperature input 0~input span (℃) |
0.0~100.0%/sec |
-5.0~+105.0% (set by upper and lower limits) |
2 points (channel-to-channel isolation) |
Upscale |
0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds) |
No effect on power outages of 20ms or less |
0.25μV/Ω (thermocouple input) |
Select 8 types of PID parameters depending on the position of the set value |
Basic type |
0.025 seconds |
±input range span |
No CT input |
Using CTL-12-S56-10L-N |
|
X-TIO-A-KK-MM*SP |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
220g |
-10~50℃ |
Maximum 10Ω per wire (resistance temperature detector input) |
AC 600V for 1 minute between each insulation block |
Between each insulation block DC 500V 20MΩ or more |
0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable) |
Input type: K |
Input type: K |
120mA or less |
0.2~50.0 seconds |
0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable) |
Brilliant PID control (with auto tuning function) |
Slow, Medium, Fast |
Relay contact output |
Relay contact output |
During temperature input 0~input span (℃) |
0.0~100.0%/sec |
-5.0~+105.0% (set by upper and lower limits) |
2 points (channel-to-channel isolation) |
Upscale |
0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds) |
No effect on power outages of 20ms or less |
0.25μV/Ω (thermocouple input) |
Select 8 types of PID parameters depending on the position of the set value |
Basic type |
0.025 seconds |
±input range span |
Using CTL-6-P-N |
Using CTL-12-S56-10L-N |
|
X-TIO-A-KK-MM*SS |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
220g |
-10~50℃ |
Maximum 10Ω per wire (resistance temperature detector input) |
AC 600V for 1 minute between each insulation block |
Between each insulation block DC 500V 20MΩ or more |
0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable) |
Input type: K |
Input type: K |
120mA or less |
0.2~50.0 seconds |
0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable) |
Brilliant PID control (with auto tuning function) |
Slow, Medium, Fast |
Relay contact output |
Relay contact output |
During temperature input 0~input span (℃) |
0.0~100.0%/sec |
-5.0~+105.0% (set by upper and lower limits) |
2 points (channel-to-channel isolation) |
Upscale |
0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds) |
No effect on power outages of 20ms or less |
0.25μV/Ω (thermocouple input) |
Select 8 types of PID parameters depending on the position of the set value |
Basic type |
0.025 seconds |
±input range span |
Using CTL-12-S56-10L-N |
Using CTL-12-S56-10L-N |
|
X-TIO-A-KK-MV*NN |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
220g |
-10~50℃ |
Maximum 10Ω per wire (resistance temperature detector input) |
AC 600V for 1 minute between each insulation block |
Between each insulation block DC 500V 20MΩ or more |
0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable) |
Input type: K |
Input type: K |
120mA or less |
0.2~50.0 seconds |
0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable) |
Brilliant PID control (with auto tuning function) |
Slow, Medium, Fast |
Voltage pulse output DC0/12V |
Relay contact output |
During temperature input 0~input span (℃) |
0.0~100.0%/sec |
-5.0~+105.0% (set by upper and lower limits) |
2 points (channel-to-channel isolation) |
Upscale |
0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds) |
No effect on power outages of 20ms or less |
0.25μV/Ω (thermocouple input) |
Select 8 types of PID parameters depending on the position of the set value |
Basic type |
0.025 seconds |
±input range span |
No CT input |
No CT input |
Click on the part number for more information about each product