Modular controller (process/temperature controller) SRX-X-TIO-A-KK-MM*NN
Modular controller (process/temperature controller) SRX-RKC INSTRUMENT

Modular controller (process/temperature controller) SRX
RKC INSTRUMENT

RKC INSTRUMENT's Response Status

Response Rate

100.0%

Response Time

15.5hours

Relatively Fast Response


About This Product

■High-speed sampling with a sampling period of 0.025 seconds

・Feedback control with a sampling period of 0.025 seconds allows it to handle rapidly changing processes. ・PID constants, various parameter settings, etc. can be set in 1/100 second units.

■One unit can control up to 2 channels and saves wiring.

・2CH can be controlled with one compact module. ・The power supply and communication lines for additional modules are consolidated into a connecting connector, reducing wiring.

■Equipped with program control function

Program control of 16 segments x 16 patterns (pattern link) is possible for each channel. *Fixed value control and program control can be switched

■Flexible digital input/output

-A digital input module and digital output module are available that can input/output up to 28 points with one unit. ・It is possible to output the temperature control module's various operation modes, operation status, various event status, etc. using digital input.

■High-speed response Ultra-high-speed feedback control 40 times per second

Introducing an ultra-high-speed sampling digital controller with a control calculation cycle of 25ms (0.025 seconds). Equipped with high-resolution input and PID constants and various parameter settings that can be set in 1/100 second increments, it accurately and accurately captures rapidly changing process quantities and outputs control calculations. High-speed temperature control for RTP (Rapid Thermal Process) processes in semiconductor manufacturing processes, such as pulse heat temperature control for flip chip bonders, halogen lamp annealing temperature control, etc., which have been difficult to control up until now, and other pressure controls. - Compatible with process control applications such as flow rate. *Other product numbers are available.

  • Product

    Modular controller (process/temperature controller) SRX

Share this product


240+ people viewing

Last viewed: 9 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Modular controller (process/temperature controller) SRX

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Power supply voltage Mass Permissible ambient temperature Influence of permissible input conductors Withstand voltage Insulation resistance Integral time (I) Measuring input (channel 2) Measuring input (channel 1) Current consumption Proportional period Differential time (D) Control method Control response Control output 2 (channel 2) Control output 1 (channel 1) Control setting range Proportional band (P) Output change rate limiter Output limiter Number of input points Operation when input is disconnected Input digital filter Effects of power outage Effect of signal source resistance Level PID Type Sampling period PV bias CT input 2 (CT input of channel 2) CT input 1 (CT input of channel 1)
Modular controller (process/temperature controller) SRX-Part Number-X-TIO-A-KK-MM*NN

X-TIO-A-KK-MM*NN

Available upon quote

DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V)

220g

-10~50℃

Maximum 10Ω per wire (resistance temperature detector input)

AC 600V for 1 minute between each insulation block

Between each insulation block DC 500V 20MΩ or more

0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable)

Input type: K
Range: -200~1,372℃

Input type: K
Range: -200~1,372℃

120mA or less

0.2~50.0 seconds

0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable)

Brilliant PID control (with auto tuning function)
Direct action/reverse action switchable

Slow, Medium, Fast

Relay contact output

Relay contact output

During temperature input 0~input span (℃)
When inputting voltage/current: 0.0~1,000.0% of input span

0.0~100.0%/sec

-5.0~+105.0% (set by upper and lower limits)

2 points (channel-to-channel isolation)
*Second input can be used as remote input.

Upscale

0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds)

No effect on power outages of 20ms or less
For more than that, you can choose between hot start 1/2 and cold start 1/2.

0.25μV/Ω (thermocouple input)

Select 8 types of PID parameters depending on the position of the set value

Basic type

0.025 seconds

±input range span

No CT input

No CT input

Modular controller (process/temperature controller) SRX-Part Number-X-TIO-A-KK-MM*NP

X-TIO-A-KK-MM*NP

Available upon quote

DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V)

220g

-10~50℃

Maximum 10Ω per wire (resistance temperature detector input)

AC 600V for 1 minute between each insulation block

Between each insulation block DC 500V 20MΩ or more

0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable)

Input type: K
Range: -200~1,372℃

Input type: K
Range: -200~1,372℃

120mA or less

0.2~50.0 seconds

0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable)

Brilliant PID control (with auto tuning function)
Direct action/reverse action switchable

Slow, Medium, Fast

Relay contact output

Relay contact output

During temperature input 0~input span (℃)
When inputting voltage/current: 0.0~1,000.0% of input span

0.0~100.0%/sec

-5.0~+105.0% (set by upper and lower limits)

2 points (channel-to-channel isolation)
*Second input can be used as remote input.

Upscale

0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds)

No effect on power outages of 20ms or less
For more than that, you can choose between hot start 1/2 and cold start 1/2.

0.25μV/Ω (thermocouple input)

Select 8 types of PID parameters depending on the position of the set value

Basic type

0.025 seconds

±input range span

Using CTL-6-P-N

No CT input

Modular controller (process/temperature controller) SRX-Part Number-X-TIO-A-KK-MM*NS

X-TIO-A-KK-MM*NS

Available upon quote

DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V)

220g

-10~50℃

Maximum 10Ω per wire (resistance temperature detector input)

AC 600V for 1 minute between each insulation block

Between each insulation block DC 500V 20MΩ or more

0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable)

Input type: K
Range: -200~1,372℃

Input type: K
Range: -200~1,372℃

120mA or less

0.2~50.0 seconds

0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable)

Brilliant PID control (with auto tuning function)
Direct action/reverse action switchable

Slow, Medium, Fast

Relay contact output

Relay contact output

During temperature input 0~input span (℃)
When inputting voltage/current: 0.0~1,000.0% of input span

0.0~100.0%/sec

-5.0~+105.0% (set by upper and lower limits)

2 points (channel-to-channel isolation)
*Second input can be used as remote input.

Upscale

0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds)

No effect on power outages of 20ms or less
For more than that, you can choose between hot start 1/2 and cold start 1/2.

0.25μV/Ω (thermocouple input)

Select 8 types of PID parameters depending on the position of the set value

Basic type

0.025 seconds

±input range span

Using CTL-12-S56-10L-N

No CT input

Modular controller (process/temperature controller) SRX-Part Number-X-TIO-A-KK-MM*PN

X-TIO-A-KK-MM*PN

Available upon quote

DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V)

220g

-10~50℃

Maximum 10Ω per wire (resistance temperature detector input)

AC 600V for 1 minute between each insulation block

Between each insulation block DC 500V 20MΩ or more

0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable)

Input type: K
Range: -200~1,372℃

Input type: K
Range: -200~1,372℃

120mA or less

0.2~50.0 seconds

0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable)

Brilliant PID control (with auto tuning function)
Direct action/reverse action switchable

Slow, Medium, Fast

Relay contact output

Relay contact output

During temperature input 0~input span (℃)
When inputting voltage/current: 0.0~1,000.0% of input span

0.0~100.0%/sec

-5.0~+105.0% (set by upper and lower limits)

2 points (channel-to-channel isolation)
*Second input can be used as remote input.

Upscale

0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds)

No effect on power outages of 20ms or less
For more than that, you can choose between hot start 1/2 and cold start 1/2.

0.25μV/Ω (thermocouple input)

Select 8 types of PID parameters depending on the position of the set value

Basic type

0.025 seconds

±input range span

No CT input

Using CTL-6-P-N

Modular controller (process/temperature controller) SRX-Part Number-X-TIO-A-KK-MM*PP

X-TIO-A-KK-MM*PP

Available upon quote

DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V)

220g

-10~50℃

Maximum 10Ω per wire (resistance temperature detector input)

AC 600V for 1 minute between each insulation block

Between each insulation block DC 500V 20MΩ or more

0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable)

Input type: K
Range: -200~1,372℃

Input type: K
Range: -200~1,372℃

120mA or less

0.2~50.0 seconds

0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable)

Brilliant PID control (with auto tuning function)
Direct action/reverse action switchable

Slow, Medium, Fast

Relay contact output

Relay contact output

During temperature input 0~input span (℃)
When inputting voltage/current: 0.0~1,000.0% of input span

0.0~100.0%/sec

-5.0~+105.0% (set by upper and lower limits)

2 points (channel-to-channel isolation)
*Second input can be used as remote input.

Upscale

0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds)

No effect on power outages of 20ms or less
For more than that, you can choose between hot start 1/2 and cold start 1/2.

0.25μV/Ω (thermocouple input)

Select 8 types of PID parameters depending on the position of the set value

Basic type

0.025 seconds

±input range span

Using CTL-6-P-N

Using CTL-6-P-N

Modular controller (process/temperature controller) SRX-Part Number-X-TIO-A-KK-MM*PS

X-TIO-A-KK-MM*PS

Available upon quote

DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V)

220g

-10~50℃

Maximum 10Ω per wire (resistance temperature detector input)

AC 600V for 1 minute between each insulation block

Between each insulation block DC 500V 20MΩ or more

0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable)

Input type: K
Range: -200~1,372℃

Input type: K
Range: -200~1,372℃

120mA or less

0.2~50.0 seconds

0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable)

Brilliant PID control (with auto tuning function)
Direct action/reverse action switchable

Slow, Medium, Fast

Relay contact output

Relay contact output

During temperature input 0~input span (℃)
When inputting voltage/current: 0.0~1,000.0% of input span

0.0~100.0%/sec

-5.0~+105.0% (set by upper and lower limits)

2 points (channel-to-channel isolation)
*Second input can be used as remote input.

Upscale

0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds)

No effect on power outages of 20ms or less
For more than that, you can choose between hot start 1/2 and cold start 1/2.

0.25μV/Ω (thermocouple input)

Select 8 types of PID parameters depending on the position of the set value

Basic type

0.025 seconds

±input range span

Using CTL-12-S56-10L-N

Using CTL-6-P-N

Modular controller (process/temperature controller) SRX-Part Number-X-TIO-A-KK-MM*SN

X-TIO-A-KK-MM*SN

Available upon quote

DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V)

220g

-10~50℃

Maximum 10Ω per wire (resistance temperature detector input)

AC 600V for 1 minute between each insulation block

Between each insulation block DC 500V 20MΩ or more

0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable)

Input type: K
Range: -200~1,372℃

Input type: K
Range: -200~1,372℃

120mA or less

0.2~50.0 seconds

0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable)

Brilliant PID control (with auto tuning function)
Direct action/reverse action switchable

Slow, Medium, Fast

Relay contact output

Relay contact output

During temperature input 0~input span (℃)
When inputting voltage/current: 0.0~1,000.0% of input span

0.0~100.0%/sec

-5.0~+105.0% (set by upper and lower limits)

2 points (channel-to-channel isolation)
*Second input can be used as remote input.

Upscale

0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds)

No effect on power outages of 20ms or less
For more than that, you can choose between hot start 1/2 and cold start 1/2.

0.25μV/Ω (thermocouple input)

Select 8 types of PID parameters depending on the position of the set value

Basic type

0.025 seconds

±input range span

No CT input

Using CTL-12-S56-10L-N

Modular controller (process/temperature controller) SRX-Part Number-X-TIO-A-KK-MM*SP

X-TIO-A-KK-MM*SP

Available upon quote

DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V)

220g

-10~50℃

Maximum 10Ω per wire (resistance temperature detector input)

AC 600V for 1 minute between each insulation block

Between each insulation block DC 500V 20MΩ or more

0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable)

Input type: K
Range: -200~1,372℃

Input type: K
Range: -200~1,372℃

120mA or less

0.2~50.0 seconds

0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable)

Brilliant PID control (with auto tuning function)
Direct action/reverse action switchable

Slow, Medium, Fast

Relay contact output

Relay contact output

During temperature input 0~input span (℃)
When inputting voltage/current: 0.0~1,000.0% of input span

0.0~100.0%/sec

-5.0~+105.0% (set by upper and lower limits)

2 points (channel-to-channel isolation)
*Second input can be used as remote input.

Upscale

0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds)

No effect on power outages of 20ms or less
For more than that, you can choose between hot start 1/2 and cold start 1/2.

0.25μV/Ω (thermocouple input)

Select 8 types of PID parameters depending on the position of the set value

Basic type

0.025 seconds

±input range span

Using CTL-6-P-N

Using CTL-12-S56-10L-N

Modular controller (process/temperature controller) SRX-Part Number-X-TIO-A-KK-MM*SS

X-TIO-A-KK-MM*SS

Available upon quote

DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V)

220g

-10~50℃

Maximum 10Ω per wire (resistance temperature detector input)

AC 600V for 1 minute between each insulation block

Between each insulation block DC 500V 20MΩ or more

0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable)

Input type: K
Range: -200~1,372℃

Input type: K
Range: -200~1,372℃

120mA or less

0.2~50.0 seconds

0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable)

Brilliant PID control (with auto tuning function)
Direct action/reverse action switchable

Slow, Medium, Fast

Relay contact output

Relay contact output

During temperature input 0~input span (℃)
When inputting voltage/current: 0.0~1,000.0% of input span

0.0~100.0%/sec

-5.0~+105.0% (set by upper and lower limits)

2 points (channel-to-channel isolation)
*Second input can be used as remote input.

Upscale

0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds)

No effect on power outages of 20ms or less
For more than that, you can choose between hot start 1/2 and cold start 1/2.

0.25μV/Ω (thermocouple input)

Select 8 types of PID parameters depending on the position of the set value

Basic type

0.025 seconds

±input range span

Using CTL-12-S56-10L-N

Using CTL-12-S56-10L-N

Modular controller (process/temperature controller) SRX-Part Number-X-TIO-A-KK-MV*NN

X-TIO-A-KK-MV*NN

Available upon quote

DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V)

220g

-10~50℃

Maximum 10Ω per wire (resistance temperature detector input)

AC 600V for 1 minute between each insulation block

Between each insulation block DC 500V 20MΩ or more

0.01~360.00 seconds or 0.1~3,600.0 seconds (switchable)

Input type: K
Range: -200~1,372℃

Input type: K
Range: -200~1,372℃

120mA or less

0.2~50.0 seconds

0.00~360.00 seconds or 0.0~3,600.0 seconds (switchable)

Brilliant PID control (with auto tuning function)
Direct action/reverse action switchable

Slow, Medium, Fast

Voltage pulse output DC0/12V

Relay contact output

During temperature input 0~input span (℃)
When inputting voltage/current: 0.0~1,000.0% of input span

0.0~100.0%/sec

-5.0~+105.0% (set by upper and lower limits)

2 points (channel-to-channel isolation)
*Second input can be used as remote input.

Upscale

0.01~10.00 seconds (digital filter OFF when connected for 0.00 seconds)

No effect on power outages of 20ms or less
For more than that, you can choose between hot start 1/2 and cold start 1/2.

0.25μV/Ω (thermocouple input)

Select 8 types of PID parameters depending on the position of the set value

Basic type

0.025 seconds

±input range span

No CT input

No CT input

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Temperature Controllers Products

Other products of RKC INSTRUMENT

Reviews shown here are reviews of companies.


View more products of RKC INSTRUMENT

About Company Handling This Product

Response Rate

100.0%


Response Time

15.5hrs

Company Overview

RKC Instrument has been continually growing for over half a century and strives to be a solution provider of m...

See More

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree