Modular controller (process/temperature controller) SRZ (Z-TIO-G)Handling Company
RKC INSTRUMENTCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply | Wiring method | Mass | Withstand voltage | Insulation resistance | Power consumption (at maximum load) | Safety standards | Factory settings | Number of output points | Output 2 | Output 1 | Number of input points | Effect of input wire resistance (RTD input) | Ambient humidity | Ambient temperature | Data protection | Type | Sampling period | Transformer for PFF | CT input | CE marking | C-Tick |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Z-TIO-GT-MM/NNN |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Terminal block type |
Approximately 160g |
Between power supply terminal/input terminal and ground: AC750V for 1 minute |
Between power supply terminal/input terminal and ground: DC500V 20MΩ or more |
Maximum 120mA *Inrush current 10A or less |
UL: UL61010-1 |
None (control operation, input range, and initial settings are not specified) |
2 points |
Relay contact output |
Relay contact output |
2 points (CH1 and CH2 are both universal inputs) |
Approximately 0.02% OF span/Ω |
5~95%RH Absolute humidity: MAX 29g/m3 Dry air at 101.3kPa |
-10~+50℃ |
Data backup using non-volatile memory |
2CH high precision high resolution type |
0.1 seconds |
None |
None |
Low voltage directive: EN61010-1 Overvoltage category II, pollution degree 2, class II (reinforced insulation) |
EN55011 |
|
Z-TIO-GT-MM/N2N |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Terminal block type |
Approximately 160g |
Between power supply terminal/input terminal and ground: AC750V for 1 minute |
Between power supply terminal/input terminal and ground: DC500V 20MΩ or more |
Maximum 120mA *Inrush current 10A or less |
UL: UL61010-1 cUL: CAN/CSA-C22.2 NO.61010-1 |
None (control operation, input range, and initial settings are not specified) |
2 points |
Relay contact output |
Relay contact output |
2 points (CH1 and CH2 are both universal inputs) |
Approximately 0.02% OF span/Ω |
5~95%RH Absolute humidity: MAX 29g/m3 Dry air at 101.3kPa |
-10~+50℃ |
Data backup using non-volatile memory |
2CH high precision high resolution type |
0.1 seconds |
1 PFF transformer included (for Max.240V) |
None |
Low voltage directive: EN61010-1 Overvoltage category II, pollution degree 2, class II (reinforced insulation) |
EN55011 |
|
Z-TIO-GT-MV/NNN |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Terminal block type |
Approximately 160g |
Between power supply terminal/input terminal and ground: AC750V for 1 minute |
Between power supply terminal/input terminal and ground: DC500V 20MΩ or more |
Maximum 120mA *Inrush current 10A or less |
UL: UL61010-1 cUL: CAN/CSA-C22.2 NO.61010-1 |
None (control operation, input range, and initial settings are not specified) |
2 points |
Voltage pulse output for SSR drive |
Relay contact output |
2 points (CH1 and CH2 are both universal inputs) |
Approximately 0.02% OF span/Ω |
5~95%RH Absolute humidity: MAX 29g/m3 Dry air at 101.3kPa |
-10~+50℃ |
Data backup using non-volatile memory |
2CH high precision high resolution type |
0.1 seconds |
None |
None |
Low voltage directive: EN61010-1 Overvoltage category II, pollution degree 2, class II (reinforced insulation) |
EN55011 |
|
Z-TIO-GT-MV/N2N |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Terminal block type |
Approximately 160g |
Between power supply terminal/input terminal and ground: AC750V for 1 minute |
Between power supply terminal/input terminal and ground: DC500V 20MΩ or more |
Maximum 120mA *Inrush current 10A or less |
UL: UL61010-1 cUL: CAN/CSA-C22.2 NO.61010-1 |
None (control operation, input range, and initial settings are not specified) |
2 points |
Voltage pulse output for SSR drive |
Relay contact output |
2 points (CH1 and CH2 are both universal inputs) |
Approximately 0.02% OF span/Ω |
5~95%RH Absolute humidity: MAX 29g/m3 Dry air at 101.3kPa |
-10~+50℃ |
Data backup using non-volatile memory |
2CH high precision high resolution type |
0.1 seconds |
1 PFF transformer included (for Max.240V) |
None |
Low voltage directive: EN61010-1 Overvoltage category II, pollution degree 2, class II (reinforced insulation) |
EN55011 |
|
Z-TIO-GT-M3/NNN |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Terminal block type |
Approximately 160g |
Between power supply terminal/input terminal and ground: AC750V for 1 minute |
Between power supply terminal/input terminal and ground: DC500V 20MΩ or more |
Maximum 120mA *Inrush current 10A or less |
UL: UL61010-1 cUL: CAN/CSA-C22.2 NO.61010-1 |
None (control operation, input range, and initial settings are not specified) |
2 points |
Continuous voltage output DC0~1V |
Relay contact output |
2 points (CH1 and CH2 are both universal inputs) |
Approximately 0.02% OF span/Ω |
5~95%RH Absolute humidity: MAX 29g/m3 Dry air at 101.3kPa |
-10~+50℃ |
Data backup using non-volatile memory |
2CH high precision high resolution type |
0.1 seconds |
None |
None |
Low voltage directive: EN61010-1 Overvoltage category II, pollution degree 2, class II (reinforced insulation) |
EN55011 |
|
Z-TIO-GT-M3/N2N |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Terminal block type |
Approximately 160g |
Between power supply terminal/input terminal and ground: AC750V for 1 minute |
Between power supply terminal/input terminal and ground: DC500V 20MΩ or more |
Maximum 120mA *Inrush current 10A or less |
UL: UL61010-1 cUL: CAN/CSA-C22.2 NO.61010-1 |
None (control operation, input range, and initial settings are not specified) |
2 points |
Continuous voltage output DC0~1V |
Relay contact output |
2 points (CH1 and CH2 are both universal inputs) |
Approximately 0.02% OF span/Ω |
5~95%RH Absolute humidity: MAX 29g/m3 Dry air at 101.3kPa |
-10~+50℃ |
Data backup using non-volatile memory |
2CH high precision high resolution type |
0.1 seconds |
1 PFF transformer included (for Max.240V) |
None |
Low voltage directive: EN61010-1 Overvoltage category II, pollution degree 2, class II (reinforced insulation) |
EN55011 |
|
Z-TIO-GT-M4/NNN |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Terminal block type |
Approximately 160g |
Between power supply terminal/input terminal and ground: AC750V for 1 minute |
Between power supply terminal/input terminal and ground: DC500V 20MΩ or more |
Maximum 120mA *Inrush current 10A or less |
UL: UL61010-1 cUL: CAN/CSA-C22.2 NO.61010-1 |
None (control operation, input range, and initial settings are not specified) |
2 points |
Continuous voltage output DC0~5V |
Relay contact output |
2 points (CH1 and CH2 are both universal inputs) |
Approximately 0.02% OF span/Ω |
5~95%RH Absolute humidity: MAX 29g/m3 Dry air at 101.3kPa |
-10~+50℃ |
Data backup using non-volatile memory |
2CH high precision high resolution type |
0.1 seconds |
None |
None |
Low voltage directive: EN61010-1 Overvoltage category II, pollution degree 2, class II (reinforced insulation) |
EN55011 |
|
Z-TIO-GT-M4/N2N |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Terminal block type |
Approximately 160g |
Between power supply terminal/input terminal and ground: AC750V for 1 minute |
Between power supply terminal/input terminal and ground: DC500V 20MΩ or more |
Maximum 120mA *Inrush current 10A or less |
UL: UL61010-1 cUL: CAN/CSA-C22.2 NO.61010-1 |
None (control operation, input range, and initial settings are not specified) |
2 points |
Continuous voltage output DC0~5V |
Relay contact output |
2 points (CH1 and CH2 are both universal inputs) |
Approximately 0.02% OF span/Ω |
5~95%RH Absolute humidity: MAX 29g/m3 Dry air at 101.3kPa |
-10~+50℃ |
Data backup using non-volatile memory |
2CH high precision high resolution type |
0.1 seconds |
1 PFF transformer included (for Max.240V) |
None |
Low voltage directive: EN61010-1 Overvoltage category II, pollution degree 2, class II (reinforced insulation) |
EN55011 |
|
Z-TIO-GT-M5/NNN |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Terminal block type |
Approximately 160g |
Between power supply terminal/input terminal and ground: AC750V for 1 minute |
Between power supply terminal/input terminal and ground: DC500V 20MΩ or more |
Maximum 120mA *Inrush current 10A or less |
UL: UL61010-1 cUL: CAN/CSA-C22.2 NO.61010-1 |
None (control operation, input range, and initial settings are not specified) |
2 points |
Continuous voltage output DC0~10V |
Relay contact output |
2 points (CH1 and CH2 are both universal inputs) |
Approximately 0.02% OF span/Ω |
5~95%RH Absolute humidity: MAX 29g/m3 Dry air at 101.3kPa |
-10~+50℃ |
Data backup using non-volatile memory |
2CH high precision high resolution type |
0.1 seconds |
None |
None |
Low voltage directive: EN61010-1 Overvoltage category II, pollution degree 2, class II (reinforced insulation) |
EN55011 |
|
Z-TIO-GT-M5/N2N |
Available upon quote |
DC21.6~26.4V [Including power supply voltage fluctuation] (Rated DC24V) |
Terminal block type |
Approximately 160g |
Between power supply terminal/input terminal and ground: AC750V for 1 minute |
Between power supply terminal/input terminal and ground: DC500V 20MΩ or more |
Maximum 120mA *Inrush current 10A or less |
UL: UL61010-1 cUL: CAN/CSA-C22.2 NO.61010-1 |
None (control operation, input range, and initial settings are not specified) |
2 points |
Continuous voltage output DC0~10V |
Relay contact output |
2 points (CH1 and CH2 are both universal inputs) |
Approximately 0.02% OF span/Ω |
5~95%RH Absolute humidity: MAX 29g/m3 Dry air at 101.3kPa |
-10~+50℃ |
Data backup using non-volatile memory |
2CH high precision high resolution type |
0.1 seconds |
1 PFF transformer included (for Max.240V) |
None |
Low voltage directive: EN61010-1 Overvoltage category II, pollution degree 2, class II (reinforced insulation) |
EN55011 |
Click on the part number for more information about each product