Digital indicating controller (process/temperature controller) FB series-FB100-MN-3*N/NN
Digital indicating controller (process/temperature controller) FB series-RKC INSTRUMENT

Digital indicating controller (process/temperature controller) FB series
RKC INSTRUMENT


About This Product

■Abundant input/output Various combinations of various input/output options are possible. ■Cooperative operation using communication ・Various cooperative operations can be performed using communication between controllers. ・Group automatic heating function with learning function ・Temperature ratio setting ・Cascade control ・Group RUN/STOP function ■Two types of PID control can be selected: "emphasis on responsiveness" and "emphasis on followability" You can choose between measured value differential type PID control (emphasis on responsiveness), which is most suitable for fixed value control, and deviation differential type PID control (emphasis on followability), which is most suitable for lamp control. ■New type of heating/cooling PID control that strengthens undershoot suppression on the cooling side - Equipped with undershoot suppression function (USS) for cooling control. *USS:UnderShoot Suppression - Dedicated control algorithm for water cooling or air cooling control can be selected. ■Equipped with loader communication - All models are equipped with a loader communication port. ・Protem2, a controller and indicator setting data management support tool, is available. *Other product numbers are available.

  • Product

    Digital indicating controller (process/temperature controller) FB series

Share this product


180+ people viewing

Last viewed: 11 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Digital indicating controller (process/temperature controller) FB series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Applicable standards Case color Digital filter Effect of signal source resistance Effects of power outage Error during close instrumentation Influence of permissible input conductors Inrush current Insulation resistance Link destination area number setting Mass Multi-memory area function Number of areas Operation when input wire is disconnected Optional features Output 1 (OUT1) Output 2 (OUT2) Output type PV bias PV ratio Permissible ambient humidity Permissible ambient temperature Power consumption Power supply voltage Sampling period Size Soak time setting Specifying factory settings Square root calculation function Usage atmosphere/conditions Withstand voltage
Digital indicating controller (process/temperature controller) FB series-Part Number-FB100-MN-3*N/NN

FB100-MN-3*N/NN

Available upon quote CE marking compliant, UL, cUL certified product, RCM marking compliant White tone Can be set from 0.1 to 100.0 seconds (OFF at 0 seconds)
0.2μV/Ω (thermocouple input) No effect on power outages of 20ms or less
For more than that, hot start or cold start can be selected.
±1.5℃ 0.01%/Ω or less (RTD input)
*However, maximum 10Ω per wire
Maximum 12A or less Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Between measurement terminal and power supply: DC 500V 20MΩ or more
1~8 (No link if set to 0) Approximately 150g 8 points Upscale/Downscale *Switchable No optional features Relay contact output No output 2 1a contact
Rating: AC250V 3A DC30V 1A (resistive load)
Electrical life: 100,000 times or more (rated load)
±input range span 0.500~1.500 5~95% (no condensation)
*Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa
-10~+50℃ AC24V specifications: max. 5.3VA
DC24V specification: max. 142mA
AC/DC24V 0.1 seconds (switchable to 0.05 seconds/0.25 seconds) 48×48mm ・Second unit setting: 0 minutes 00 seconds ~199 minutes 59 seconds
・Minute setting: 0 hours 0 minutes ~99 hours 59 minutes
*Selectable
None Arithmetic formula: PV=√ (input value x PV ratio + PV bias)
Low level cutoff: 0.00~25.00% of span
No corrosive or flammable gases, and no heavy dust.
No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Between measurement terminal and power supply: AC 2,300V for 1 minute
Digital indicating controller (process/temperature controller) FB series-Part Number-FB100-MN-3*N/AN

FB100-MN-3*N/AN

Available upon quote CE marking compliant, UL, cUL certified product, RCM marking compliant Black tone Can be set from 0.1 to 100.0 seconds (OFF at 0 seconds)
0.2μV/Ω (thermocouple input) No effect on power outages of 20ms or less
For more than that, hot start or cold start can be selected.
±1.5℃ 0.01%/Ω or less (RTD input)
*However, maximum 10Ω per wire
Maximum 12A or less Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Between measurement terminal and power supply: DC 500V 20MΩ or more
1~8 (No link if set to 0) Approximately 150g 8 points Upscale/Downscale *Switchable No optional features Relay contact output No output 2 1a contact
Rating: AC250V 3A DC30V 1A (resistive load)
Electrical life: 100,000 times or more (rated load)
±input range span 0.500~1.500 5~95% (no condensation)
*Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa
-10~+50℃ AC24V specifications: max. 5.3VA
DC24V specification: max. 142mA
AC/DC24V 0.1 seconds (switchable to 0.05 seconds/0.25 seconds) 48×48mm ・Second unit setting: 0 minutes 00 seconds ~199 minutes 59 seconds
・Minute setting: 0 hours 0 minutes ~99 hours 59 minutes
*Selectable
None Arithmetic formula: PV=√ (input value x PV ratio + PV bias)
Low level cutoff: 0.00~25.00% of span
No corrosive or flammable gases, and no heavy dust.
No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Between measurement terminal and power supply: AC 2,300V for 1 minute
Digital indicating controller (process/temperature controller) FB series-Part Number-FB100-MN-3*A/NN

FB100-MN-3*A/NN

Available upon quote CE marking compliant, UL, cUL certified product, RCM marking compliant White tone Can be set from 0.1 to 100.0 seconds (OFF at 0 seconds)
0.2μV/Ω (thermocouple input) No effect on power outages of 20ms or less
For more than that, hot start or cold start can be selected.
±1.5℃ 0.01%/Ω or less (RTD input)
*However, maximum 10Ω per wire
Maximum 12A or less Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Between measurement terminal and power supply: DC 500V 20MΩ or more
1~8 (No link if set to 0) Approximately 150g 8 points Upscale/Downscale *Switchable 5 digital inputs Relay contact output No output 2 1a contact
Rating: AC250V 3A DC30V 1A (resistive load)
Electrical life: 100,000 times or more (rated load)
±input range span 0.500~1.500 5~95% (no condensation)
*Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa
-10~+50℃ AC24V specifications: max. 5.3VA
DC24V specification: max. 142mA
AC/DC24V 0.1 seconds (switchable to 0.05 seconds/0.25 seconds) 48×48mm ・Second unit setting: 0 minutes 00 seconds ~199 minutes 59 seconds
・Minute setting: 0 hours 0 minutes ~99 hours 59 minutes
*Selectable
None Arithmetic formula: PV=√ (input value x PV ratio + PV bias)
Low level cutoff: 0.00~25.00% of span
No corrosive or flammable gases, and no heavy dust.
No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Between measurement terminal and power supply: AC 2,300V for 1 minute
Digital indicating controller (process/temperature controller) FB series-Part Number-FB100-MN-3*A/AN

FB100-MN-3*A/AN

Available upon quote CE marking compliant, UL, cUL certified product, RCM marking compliant Black tone Can be set from 0.1 to 100.0 seconds (OFF at 0 seconds)
0.2μV/Ω (thermocouple input) No effect on power outages of 20ms or less
For more than that, hot start or cold start can be selected.
±1.5℃ 0.01%/Ω or less (RTD input)
*However, maximum 10Ω per wire
Maximum 12A or less Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Between measurement terminal and power supply: DC 500V 20MΩ or more
1~8 (No link if set to 0) Approximately 150g 8 points Upscale/Downscale *Switchable 5 digital inputs Relay contact output No output 2 1a contact
Rating: AC250V 3A DC30V 1A (resistive load)
Electrical life: 100,000 times or more (rated load)
±input range span 0.500~1.500 5~95% (no condensation)
*Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa
-10~+50℃ AC24V specifications: max. 5.3VA
DC24V specification: max. 142mA
AC/DC24V 0.1 seconds (switchable to 0.05 seconds/0.25 seconds) 48×48mm ・Second unit setting: 0 minutes 00 seconds ~199 minutes 59 seconds
・Minute setting: 0 hours 0 minutes ~99 hours 59 minutes
*Selectable
None Arithmetic formula: PV=√ (input value x PV ratio + PV bias)
Low level cutoff: 0.00~25.00% of span
No corrosive or flammable gases, and no heavy dust.
No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Between measurement terminal and power supply: AC 2,300V for 1 minute
Digital indicating controller (process/temperature controller) FB series-Part Number-FB100-MN-3*B/NN

FB100-MN-3*B/NN

Available upon quote CE marking compliant, UL, cUL certified product, RCM marking compliant White tone Can be set from 0.1 to 100.0 seconds (OFF at 0 seconds)
0.2μV/Ω (thermocouple input) No effect on power outages of 20ms or less
For more than that, hot start or cold start can be selected.
±1.5℃ 0.01%/Ω or less (RTD input)
*However, maximum 10Ω per wire
Maximum 12A or less Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Between measurement terminal and power supply: DC 500V 20MΩ or more
1~8 (No link if set to 0) Approximately 150g 8 points Upscale/Downscale *Switchable 2 digital inputs + remote setting input Relay contact output No output 2 1a contact
Rating: AC250V 3A DC30V 1A (resistive load)
Electrical life: 100,000 times or more (rated load)
±input range span 0.500~1.500 5~95% (no condensation)
*Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa
-10~+50℃ AC24V specifications: max. 5.3VA
DC24V specification: max. 142mA
AC/DC24V 0.1 seconds (switchable to 0.05 seconds/0.25 seconds) 48×48mm ・Second unit setting: 0 minutes 00 seconds ~199 minutes 59 seconds
・Minute setting: 0 hours 0 minutes ~99 hours 59 minutes
*Selectable
None Arithmetic formula: PV=√ (input value x PV ratio + PV bias)
Low level cutoff: 0.00~25.00% of span
No corrosive or flammable gases, and no heavy dust.
No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Between measurement terminal and power supply: AC 2,300V for 1 minute
Digital indicating controller (process/temperature controller) FB series-Part Number-FB100-MN-3*B/AN

FB100-MN-3*B/AN

Available upon quote CE marking compliant, UL, cUL certified product, RCM marking compliant Black tone Can be set from 0.1 to 100.0 seconds (OFF at 0 seconds)
0.2μV/Ω (thermocouple input) No effect on power outages of 20ms or less
For more than that, hot start or cold start can be selected.
±1.5℃ 0.01%/Ω or less (RTD input)
*However, maximum 10Ω per wire
Maximum 12A or less Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Between measurement terminal and power supply: DC 500V 20MΩ or more
1~8 (No link if set to 0) Approximately 150g 8 points Upscale/Downscale *Switchable 2 digital inputs + remote setting input Relay contact output No output 2 1a contact
Rating: AC250V 3A DC30V 1A (resistive load)
Electrical life: 100,000 times or more (rated load)
±input range span 0.500~1.500 5~95% (no condensation)
*Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa
-10~+50℃ AC24V specifications: max. 5.3VA
DC24V specification: max. 142mA
AC/DC24V 0.1 seconds (switchable to 0.05 seconds/0.25 seconds) 48×48mm ・Second unit setting: 0 minutes 00 seconds ~199 minutes 59 seconds
・Minute setting: 0 hours 0 minutes ~99 hours 59 minutes
*Selectable
None Arithmetic formula: PV=√ (input value x PV ratio + PV bias)
Low level cutoff: 0.00~25.00% of span
No corrosive or flammable gases, and no heavy dust.
No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Between measurement terminal and power supply: AC 2,300V for 1 minute
Digital indicating controller (process/temperature controller) FB series-Part Number-FB100-MN-3*C/NN

FB100-MN-3*C/NN

Available upon quote CE marking compliant, UL, cUL certified product, RCM marking compliant White tone Can be set from 0.1 to 100.0 seconds (OFF at 0 seconds)
0.2μV/Ω (thermocouple input) No effect on power outages of 20ms or less
For more than that, hot start or cold start can be selected.
±1.5℃ 0.01%/Ω or less (RTD input)
*However, maximum 10Ω per wire
Maximum 12A or less Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Between measurement terminal and power supply: DC 500V 20MΩ or more
1~8 (No link if set to 0) Approximately 150g 8 points Upscale/Downscale *Switchable 2 digital inputs + opening feedback resistance input Relay contact output No output 2 1a contact
Rating: AC250V 3A DC30V 1A (resistive load)
Electrical life: 100,000 times or more (rated load)
±input range span 0.500~1.500 5~95% (no condensation)
*Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa
-10~+50℃ AC24V specifications: max. 5.3VA
DC24V specification: max. 142mA
AC/DC24V 0.1 seconds (switchable to 0.05 seconds/0.25 seconds) 48×48mm ・Second unit setting: 0 minutes 00 seconds ~199 minutes 59 seconds
・Minute setting: 0 hours 0 minutes ~99 hours 59 minutes
*Selectable
None Arithmetic formula: PV=√ (input value x PV ratio + PV bias)
Low level cutoff: 0.00~25.00% of span
No corrosive or flammable gases, and no heavy dust.
No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Between measurement terminal and power supply: AC 2,300V for 1 minute
Digital indicating controller (process/temperature controller) FB series-Part Number-FB100-MN-3*C/AN

FB100-MN-3*C/AN

Available upon quote CE marking compliant, UL, cUL certified product, RCM marking compliant Black tone Can be set from 0.1 to 100.0 seconds (OFF at 0 seconds)
0.2μV/Ω (thermocouple input) No effect on power outages of 20ms or less
For more than that, hot start or cold start can be selected.
±1.5℃ 0.01%/Ω or less (RTD input)
*However, maximum 10Ω per wire
Maximum 12A or less Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Between measurement terminal and power supply: DC 500V 20MΩ or more
1~8 (No link if set to 0) Approximately 150g 8 points Upscale/Downscale *Switchable 2 digital inputs + opening feedback resistance input Relay contact output No output 2 1a contact
Rating: AC250V 3A DC30V 1A (resistive load)
Electrical life: 100,000 times or more (rated load)
±input range span 0.500~1.500 5~95% (no condensation)
*Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa
-10~+50℃ AC24V specifications: max. 5.3VA
DC24V specification: max. 142mA
AC/DC24V 0.1 seconds (switchable to 0.05 seconds/0.25 seconds) 48×48mm ・Second unit setting: 0 minutes 00 seconds ~199 minutes 59 seconds
・Minute setting: 0 hours 0 minutes ~99 hours 59 minutes
*Selectable
None Arithmetic formula: PV=√ (input value x PV ratio + PV bias)
Low level cutoff: 0.00~25.00% of span
No corrosive or flammable gases, and no heavy dust.
No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Between measurement terminal and power supply: AC 2,300V for 1 minute
Digital indicating controller (process/temperature controller) FB series-Part Number-FB100-MN-3*D/NN

FB100-MN-3*D/NN

Available upon quote CE marking compliant, UL, cUL certified product, RCM marking compliant White tone Can be set from 0.1 to 100.0 seconds (OFF at 0 seconds)
0.2μV/Ω (thermocouple input) No effect on power outages of 20ms or less
For more than that, hot start or cold start can be selected.
±1.5℃ 0.01%/Ω or less (RTD input)
*However, maximum 10Ω per wire
Maximum 12A or less Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Between measurement terminal and power supply: DC 500V 20MΩ or more
1~8 (No link if set to 0) Approximately 150g 8 points Upscale/Downscale *Switchable 2 digital inputs + 2 CT inputs (CT is sold separately) Relay contact output No output 2 1a contact
Rating: AC250V 3A DC30V 1A (resistive load)
Electrical life: 100,000 times or more (rated load)
±input range span 0.500~1.500 5~95% (no condensation)
*Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa
-10~+50℃ AC24V specifications: max. 5.3VA
DC24V specification: max. 142mA
AC/DC24V 0.1 seconds (switchable to 0.05 seconds/0.25 seconds) 48×48mm ・Second unit setting: 0 minutes 00 seconds ~199 minutes 59 seconds
・Minute setting: 0 hours 0 minutes ~99 hours 59 minutes
*Selectable
None Arithmetic formula: PV=√ (input value x PV ratio + PV bias)
Low level cutoff: 0.00~25.00% of span
No corrosive or flammable gases, and no heavy dust.
No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Between measurement terminal and power supply: AC 2,300V for 1 minute
Digital indicating controller (process/temperature controller) FB series-Part Number-FB100-MN-3*D/AN

FB100-MN-3*D/AN

Available upon quote CE marking compliant, UL, cUL certified product, RCM marking compliant Black tone Can be set from 0.1 to 100.0 seconds (OFF at 0 seconds)
0.2μV/Ω (thermocouple input) No effect on power outages of 20ms or less
For more than that, hot start or cold start can be selected.
±1.5℃ 0.01%/Ω or less (RTD input)
*However, maximum 10Ω per wire
Maximum 12A or less Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Between measurement terminal and power supply: DC 500V 20MΩ or more
1~8 (No link if set to 0) Approximately 150g 8 points Upscale/Downscale *Switchable 2 digital inputs + 2 CT inputs (CT is sold separately) Relay contact output No output 2 1a contact
Rating: AC250V 3A DC30V 1A (resistive load)
Electrical life: 100,000 times or more (rated load)
±input range span 0.500~1.500 5~95% (no condensation)
*Absolute humidity: MAX.W.C 29.3g/m3 dry air at 101.3kPa
-10~+50℃ AC24V specifications: max. 5.3VA
DC24V specification: max. 142mA
AC/DC24V 0.1 seconds (switchable to 0.05 seconds/0.25 seconds) 48×48mm ・Second unit setting: 0 minutes 00 seconds ~199 minutes 59 seconds
・Minute setting: 0 hours 0 minutes ~99 hours 59 minutes
*Selectable
None Arithmetic formula: PV=√ (input value x PV ratio + PV bias)
Low level cutoff: 0.00~25.00% of span
No corrosive or flammable gases, and no heavy dust.
No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Between measurement terminal and power supply: AC 2,300V for 1 minute

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of RKC INSTRUMENT


View more products of RKC INSTRUMENT

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree