All Categories

History

Digital indicating controller (temperature controller) REX-C series-C100FK01-M*NN
Digital indicating controller (temperature controller) REX-C series-RKC INSTRUMENT

Digital indicating controller (temperature controller) REX-C series
RKC INSTRUMENT

RKC INSTRUMENT's Response Status

Response Rate

100.0%

Response Time

14.3hours

Relatively Fast Response


About This Product

■REX-C series

REX-C100 / REX-C400 / REX-C410 / REX-C700 / REX-C900

■Easy to use with excellent cost performance

From hobby pottery to industrial temperature control: PID control controllers, which have become common knowledge in temperature control for industrial products, have become cheaper year by year, and are now widely used in hobby fields such as cloisonné. Now it looks like this. Although the NEW Zero series is a high-precision controller with a built-in MCU, it is extremely easy to operate as all settings can be made using four keys, so anyone can learn it quickly. What's more, the troublesome setting of PID constants can be determined by auto-tuning to find the optimal values. Thanks to the advanced technology we have cultivated over many years in the industrial field, we can now easily achieve highly accurate and highly stable temperature control in all fields.

■Features

- Compatible with a wide range of processes thanks to the 4-digit display common to all models and 2 independent alarm outputs. ・Suitable for controlling objects that generate self-heating, such as extruders, with heating and cooling control. (Excluding REX-C100) ・In addition to control loop disconnection alarm (LBA), heater disconnection alarm (HBA) can be added. ・In addition to AC100 to 240V and DC24V, AC24V is also standard.

■Long-selling model

This is a long-selling digital temperature controller model with easy-to-operate PID auto-tuning.

■SET key method that prevents incorrect settings

Adopts a SET key (registration key) method that prevents incorrect settings.

■Multi-function

You can choose from heating, cooling, and heating/cooling PID operations. Temperature alarm, heater break alarm, and loop break alarm can be added.

■Easy operation with soft touch

NEW ZERO SERIES has a total of 5 types in DIN size, from the large display REX-C900 to the space-saving REX-C100. Changing settings is soft and smooth thanks to the front-operated key switch with a clicky feel. Moreover, the simple design makes it easy for anyone to wear it. A friendly design that displays various visual reports, PID constant settings, etc. in easy-to-understand characters. PID-controlled temperature controllers have become more accessible.

■Power supply voltage

Please specify one. AC100~240V, AC24V, DC24V *Other product numbers are available.

  • Product

    Digital indicating controller (temperature controller) REX-C series

Share this product


290+ people viewing

Last viewed: 6 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Digital indicating controller (temperature controller) REX-C series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Weight Permissible ambient humidity Permissible ambient temperature Withstand voltage Insulation resistance Second alarm First alarm Power consumption Effect of external resistance Heating side output Control operation Output Cooling side output Effect of input lead resistance Input type Effects of power outage Usage atmosphere Range Data backup Sampling period Size Other conditions Operation when input wire is disconnected
Digital indicating controller (temperature controller) REX-C series-Part Number-C100FK01-M*NN

C100FK01-M*NN

Available upon quote

Approximately 170g

45~85%RH

0~+50℃ (32~122℉)

Between measurement terminal and ground terminal: AC1,000V for 1 minute
Between power supply terminal and ground terminal: AC1,500V for 1 minute

Between measurement terminal and ground terminal: DC500V 20MΩ or more
Between power supply terminal and ground terminal 500V DC 20MΩ or more

No alarm

No alarm

AC specifications: 17VA or less
AC24V specification: 7.5VA or less
DC specifications: DC24V 200mA or less

Approx. 0.35μV/Ω (thermocouple input)

Relay contact output

With AT PID operation (reverse operation)

AC250V 3A (resistive load) *Electrical life: 300,000 times or more Rated load

No cooling side output

Approximately 0.01 (%/Ω) of reading (RTD input)
*However, maximum 10Ω per wire

K

Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state.

No corrosive or flammable gases, and no heavy dust.

0~200℃

Data backup using non-volatile memory

0.5 seconds

48×48mm

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Upscale (downscale can be specified)

Digital indicating controller (temperature controller) REX-C series-Part Number-C100FK01-M*NA

C100FK01-M*NA

Available upon quote

Approximately 170g

45~85%RH

0~+50℃ (32~122℉)

Between measurement terminal and ground terminal: AC1,000V for 1 minute
Between power supply terminal and ground terminal: AC1,500V for 1 minute

Between measurement terminal and ground terminal: DC500V 20MΩ or more
Between power supply terminal and ground terminal 500V DC 20MΩ or more

Upper limit deviation alarm

No alarm

AC specifications: 17VA or less
AC24V specification: 7.5VA or less
DC specifications: DC24V 200mA or less

Approx. 0.35μV/Ω (thermocouple input)

Relay contact output

With AT PID operation (reverse operation)

AC250V 3A (resistive load) *Electrical life: 300,000 times or more Rated load

No cooling side output

Approximately 0.01 (%/Ω) of reading (RTD input)
*However, maximum 10Ω per wire

K

Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state.

No corrosive or flammable gases, and no heavy dust.

0~200℃

Data backup using non-volatile memory

0.5 seconds

48×48mm

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Upscale (downscale can be specified)

Digital indicating controller (temperature controller) REX-C series-Part Number-C100FK01-M*NB

C100FK01-M*NB

Available upon quote

Approximately 170g

45~85%RH

0~+50℃ (32~122℉)

Between measurement terminal and ground terminal: AC1,000V for 1 minute
Between power supply terminal and ground terminal: AC1,500V for 1 minute

Between measurement terminal and ground terminal: DC500V 20MΩ or more
Between power supply terminal and ground terminal 500V DC 20MΩ or more

Lower limit deviation alarm

No alarm

AC specifications: 17VA or less
AC24V specification: 7.5VA or less
DC specifications: DC24V 200mA or less

Approx. 0.35μV/Ω (thermocouple input)

Relay contact output

With AT PID operation (reverse operation)

AC250V 3A (resistive load) *Electrical life: 300,000 times or more Rated load

No cooling side output

Approximately 0.01 (%/Ω) of reading (RTD input)
*However, maximum 10Ω per wire

K

Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state.

No corrosive or flammable gases, and no heavy dust.

0~200℃

Data backup using non-volatile memory

0.5 seconds

48×48mm

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Upscale (downscale can be specified)

Digital indicating controller (temperature controller) REX-C series-Part Number-C100FK01-M*NC

C100FK01-M*NC

Available upon quote

Approximately 170g

45~85%RH

0~+50℃ (32~122℉)

Between measurement terminal and ground terminal: AC1,000V for 1 minute
Between power supply terminal and ground terminal: AC1,500V for 1 minute

Between measurement terminal and ground terminal: DC500V 20MΩ or more
Between power supply terminal and ground terminal 500V DC 20MΩ or more

Upper and lower limit deviation alarm

No alarm

AC specifications: 17VA or less
AC24V specification: 7.5VA or less
DC specifications: DC24V 200mA or less

Approx. 0.35μV/Ω (thermocouple input)

Relay contact output

With AT PID operation (reverse operation)

AC250V 3A (resistive load) *Electrical life: 300,000 times or more Rated load

No cooling side output

Approximately 0.01 (%/Ω) of reading (RTD input)
*However, maximum 10Ω per wire

K

Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state.

No corrosive or flammable gases, and no heavy dust.

0~200℃

Data backup using non-volatile memory

0.5 seconds

48×48mm

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Upscale (downscale can be specified)

Digital indicating controller (temperature controller) REX-C series-Part Number-C100FK01-M*ND

C100FK01-M*ND

Available upon quote

Approximately 170g

45~85%RH

0~+50℃ (32~122℉)

Between measurement terminal and ground terminal: AC1,000V for 1 minute
Between power supply terminal and ground terminal: AC1,500V for 1 minute

Between measurement terminal and ground terminal: DC500V 20MΩ or more
Between power supply terminal and ground terminal 500V DC 20MΩ or more

Within range alarm

No alarm

AC specifications: 17VA or less
AC24V specification: 7.5VA or less
DC specifications: DC24V 200mA or less

Approx. 0.35μV/Ω (thermocouple input)

Relay contact output

With AT PID operation (reverse operation)

AC250V 3A (resistive load) *Electrical life: 300,000 times or more Rated load

No cooling side output

Approximately 0.01 (%/Ω) of reading (RTD input)
*However, maximum 10Ω per wire

K

Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state.

No corrosive or flammable gases, and no heavy dust.

0~200℃

Data backup using non-volatile memory

0.5 seconds

48×48mm

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Upscale (downscale can be specified)

Digital indicating controller (temperature controller) REX-C series-Part Number-C100FK01-M*NE

C100FK01-M*NE

Available upon quote

Approximately 170g

45~85%RH

0~+50℃ (32~122℉)

Between measurement terminal and ground terminal: AC1,000V for 1 minute
Between power supply terminal and ground terminal: AC1,500V for 1 minute

Between measurement terminal and ground terminal: DC500V 20MΩ or more
Between power supply terminal and ground terminal 500V DC 20MΩ or more

Upper limit deviation alarm with standby

No alarm

AC specifications: 17VA or less
AC24V specification: 7.5VA or less
DC specifications: DC24V 200mA or less

Approx. 0.35μV/Ω (thermocouple input)

Relay contact output

With AT PID operation (reverse operation)

AC250V 3A (resistive load) *Electrical life: 300,000 times or more Rated load

No cooling side output

Approximately 0.01 (%/Ω) of reading (RTD input)
*However, maximum 10Ω per wire

K

Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state.

No corrosive or flammable gases, and no heavy dust.

0~200℃

Data backup using non-volatile memory

0.5 seconds

48×48mm

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Upscale (downscale can be specified)

Digital indicating controller (temperature controller) REX-C series-Part Number-C100FK01-M*NF

C100FK01-M*NF

Available upon quote

Approximately 170g

45~85%RH

0~+50℃ (32~122℉)

Between measurement terminal and ground terminal: AC1,000V for 1 minute
Between power supply terminal and ground terminal: AC1,500V for 1 minute

Between measurement terminal and ground terminal: DC500V 20MΩ or more
Between power supply terminal and ground terminal 500V DC 20MΩ or more

Lower limit deviation alarm with delay

No alarm

AC specifications: 17VA or less
AC24V specification: 7.5VA or less
DC specifications: DC24V 200mA or less

Approx. 0.35μV/Ω (thermocouple input)

Relay contact output

With AT PID operation (reverse operation)

AC250V 3A (resistive load) *Electrical life: 300,000 times or more Rated load

No cooling side output

Approximately 0.01 (%/Ω) of reading (RTD input)
*However, maximum 10Ω per wire

K

Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state.

No corrosive or flammable gases, and no heavy dust.

0~200℃

Data backup using non-volatile memory

0.5 seconds

48×48mm

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Upscale (downscale can be specified)

Digital indicating controller (temperature controller) REX-C series-Part Number-C100FK01-M*NG

C100FK01-M*NG

Available upon quote

Approximately 170g

45~85%RH

0~+50℃ (32~122℉)

Between measurement terminal and ground terminal: AC1,000V for 1 minute
Between power supply terminal and ground terminal: AC1,500V for 1 minute

Between measurement terminal and ground terminal: DC500V 20MΩ or more
Between power supply terminal and ground terminal 500V DC 20MΩ or more

Waiting note upper and lower limit warning

No alarm

AC specifications: 17VA or less
AC24V specification: 7.5VA or less
DC specifications: DC24V 200mA or less

Approx. 0.35μV/Ω (thermocouple input)

Relay contact output

With AT PID operation (reverse operation)

AC250V 3A (resistive load) *Electrical life: 300,000 times or more Rated load

No cooling side output

Approximately 0.01 (%/Ω) of reading (RTD input)
*However, maximum 10Ω per wire

K

Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state.

No corrosive or flammable gases, and no heavy dust.

0~200℃

Data backup using non-volatile memory

0.5 seconds

48×48mm

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Upscale (downscale can be specified)

Digital indicating controller (temperature controller) REX-C series-Part Number-C100FK01-M*NH

C100FK01-M*NH

Available upon quote

Approximately 170g

45~85%RH

0~+50℃ (32~122℉)

Between measurement terminal and ground terminal: AC1,000V for 1 minute
Between power supply terminal and ground terminal: AC1,500V for 1 minute

Between measurement terminal and ground terminal: DC500V 20MΩ or more
Between power supply terminal and ground terminal 500V DC 20MΩ or more

Upper limit input value alarm

No alarm

AC specifications: 17VA or less
AC24V specification: 7.5VA or less
DC specifications: DC24V 200mA or less

Approx. 0.35μV/Ω (thermocouple input)

Relay contact output

With AT PID operation (reverse operation)

AC250V 3A (resistive load) *Electrical life: 300,000 times or more Rated load

No cooling side output

Approximately 0.01 (%/Ω) of reading (RTD input)
*However, maximum 10Ω per wire

K

Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state.

No corrosive or flammable gases, and no heavy dust.

0~200℃

Data backup using non-volatile memory

0.5 seconds

48×48mm

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Upscale (downscale can be specified)

Digital indicating controller (temperature controller) REX-C series-Part Number-C100FK01-M*NJ

C100FK01-M*NJ

Available upon quote

Approximately 170g

45~85%RH

0~+50℃ (32~122℉)

Between measurement terminal and ground terminal: AC1,000V for 1 minute
Between power supply terminal and ground terminal: AC1,500V for 1 minute

Between measurement terminal and ground terminal: DC500V 20MΩ or more
Between power supply terminal and ground terminal 500V DC 20MΩ or more

Lower limit input value alarm

No alarm

AC specifications: 17VA or less
AC24V specification: 7.5VA or less
DC specifications: DC24V 200mA or less

Approx. 0.35μV/Ω (thermocouple input)

Relay contact output

With AT PID operation (reverse operation)

AC250V 3A (resistive load) *Electrical life: 300,000 times or more Rated load

No cooling side output

Approximately 0.01 (%/Ω) of reading (RTD input)
*However, maximum 10Ω per wire

K

Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state.

No corrosive or flammable gases, and no heavy dust.

0~200℃

Data backup using non-volatile memory

0.5 seconds

48×48mm

No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.

Upscale (downscale can be specified)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Temperature Controllers Products

Other products of RKC INSTRUMENT

Reviews shown here are reviews of companies.


View more products of RKC INSTRUMENT

About Company Handling This Product

Response Rate

100.0%


Response Time

14.3hrs

Company Overview

RKC Instrument has been continually growing for over half a century and strives to be a solution provider of m...

See More

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree