Product
Digital indicating controller (temperature controller) CB seriesHandling Company
RKC INSTRUMENTCategories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | 1st alarm | 2nd alarm | Applicable standards | Body color | Communication function | Control operation | Effect of external resistance | Effect of input lead resistance | Effects of power outage | Input/range | Insulation resistance | Memory backup | Number of input points | Operation during input short circuit | Operation when input wire is disconnected | Other conditions | Output 1 (OUT1) Control output | Output 2 (OUT2) Control output | PV bias When temperature input | PV bias When voltage/current input | Permissible ambient humidity | Permissible ambient temperature | Sampling period | Usage atmosphere | Waterproof and dustproof structure | Weight | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CB100FK01-M*NN-NN/N |
Available upon quote | None | None |
CE marking compliant, UL, cUL certified product Compliant with RoHS Directive *The triac drive trigger output does not comply with or correspond to CE marking, UL, or cUL. |
White tone | None | PID operation (reverse operation) | Approx. 0.2μV/Ω (thermocouple input) | Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire | Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. | Thermocouple: K, 0~200℃ |
Between measurement terminal and ground DC 500V 20MΩ or more Between power terminal and ground DC 500V 20MΩ or more |
Data backup using non-volatile memory (approximately 10 years) | 1 point | Downscale (RTD input) | Upscale |
No external noise and no direct vibration or impact. A place that is not exposed to direct sunlight. |
Relay contact output | None (for control action F or D) | -1,999~+9,999℃ or -199.9~+999.9℃ | -span~+span | 45~85%RH | 0~50℃ | 0.5 seconds |
No corrosive or flammable gases, and no heavy dust. |
No waterproof/dustproof structure | Approximately 170g |
Between measurement terminal and ground: AC 1,000V for 1 minute Between power terminal and ground: AC 1,500V for 1 minute |
|
CB100FK01-M*NN-NN/A |
Available upon quote | None | None |
CE marking compliant, UL, cUL certified product Compliant with RoHS Directive *The triac drive trigger output does not comply with or correspond to CE marking, UL, or cUL. |
Black tone | None | PID operation (reverse operation) | Approx. 0.2μV/Ω (thermocouple input) | Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire | Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. | Thermocouple: K, 0~200℃ |
Between measurement terminal and ground DC 500V 20MΩ or more Between power terminal and ground DC 500V 20MΩ or more |
Data backup using non-volatile memory (approximately 10 years) | 1 point | Downscale (RTD input) | Upscale |
No external noise and no direct vibration or impact. A place that is not exposed to direct sunlight. |
Relay contact output | None (for control action F or D) | -1,999~+9,999℃ or -199.9~+999.9℃ | -span~+span | 45~85%RH | 0~50℃ | 0.5 seconds |
No corrosive or flammable gases, and no heavy dust. |
No waterproof/dustproof structure | Approximately 170g |
Between measurement terminal and ground: AC 1,000V for 1 minute Between power terminal and ground: AC 1,500V for 1 minute |
|
CB100FK01-M*NN-N1/A |
Available upon quote | None | None |
CE marking compliant, UL, cUL certified product Compliant with RoHS Directive *The triac drive trigger output does not comply with or correspond to CE marking, UL, or cUL. |
Black tone | None | PID operation (reverse operation) | Approx. 0.2μV/Ω (thermocouple input) | Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire | Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. | Thermocouple: K, 0~200℃ |
Between measurement terminal and ground DC 500V 20MΩ or more Between power terminal and ground DC 500V 20MΩ or more |
Data backup using non-volatile memory (approximately 10 years) | 1 point | Downscale (RTD input) | Upscale |
No external noise and no direct vibration or impact. A place that is not exposed to direct sunlight. |
Relay contact output | None (for control action F or D) | -1,999~+9,999℃ or -199.9~+999.9℃ | -span~+span | 45~85%RH | 0~50℃ | 0.5 seconds |
No corrosive or flammable gases, and no heavy dust. |
Waterproof and dustproof structure available | Approximately 170g |
Between measurement terminal and ground: AC 1,000V for 1 minute Between power terminal and ground: AC 1,500V for 1 minute |
|
CB100FK01-M*NN-5N/N |
Available upon quote | None | None |
CE marking compliant, UL, cUL certified product Compliant with RoHS Directive *The triac drive trigger output does not comply with or correspond to CE marking, UL, or cUL. |
White tone | RS-485 (RKC standard protocol) | PID operation (reverse operation) | Approx. 0.2μV/Ω (thermocouple input) | Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire | Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. | Thermocouple: K, 0~200℃ |
Between measurement terminal and ground DC 500V 20MΩ or more Between power terminal and ground DC 500V 20MΩ or more |
Data backup using non-volatile memory (approximately 10 years) | 1 point | Downscale (RTD input) | Upscale |
No external noise and no direct vibration or impact. A place that is not exposed to direct sunlight. |
Relay contact output | None (for control action F or D) | -1,999~+9,999℃ or -199.9~+999.9℃ | -span~+span | 45~85%RH | 0~50℃ | 0.5 seconds |
No corrosive or flammable gases, and no heavy dust. |
No waterproof/dustproof structure | Approximately 170g |
Between measurement terminal and ground: AC 1,000V for 1 minute Between power terminal and ground: AC 1,500V for 1 minute |
|
CB100FK01-M*NN-5N/A |
Available upon quote | None | None |
CE marking compliant, UL, cUL certified product Compliant with RoHS Directive *The triac drive trigger output does not comply with or correspond to CE marking, UL, or cUL. |
Black tone | RS-485 (RKC standard protocol) | PID operation (reverse operation) | Approx. 0.2μV/Ω (thermocouple input) | Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire | Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. | Thermocouple: K, 0~200℃ |
Between measurement terminal and ground DC 500V 20MΩ or more Between power terminal and ground DC 500V 20MΩ or more |
Data backup using non-volatile memory (approximately 10 years) | 1 point | Downscale (RTD input) | Upscale |
No external noise and no direct vibration or impact. A place that is not exposed to direct sunlight. |
Relay contact output | None (for control action F or D) | -1,999~+9,999℃ or -199.9~+999.9℃ | -span~+span | 45~85%RH | 0~50℃ | 0.5 seconds |
No corrosive or flammable gases, and no heavy dust. |
No waterproof/dustproof structure | Approximately 170g |
Between measurement terminal and ground: AC 1,000V for 1 minute Between power terminal and ground: AC 1,500V for 1 minute |
|
CB100FK01-M*NN-51/A |
Available upon quote | None | None |
CE marking compliant, UL, cUL certified product Compliant with RoHS Directive *The triac drive trigger output does not comply with or correspond to CE marking, UL, or cUL. |
Black tone | RS-485 (RKC standard protocol) | PID operation (reverse operation) | Approx. 0.2μV/Ω (thermocouple input) | Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire | Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. | Thermocouple: K, 0~200℃ |
Between measurement terminal and ground DC 500V 20MΩ or more Between power terminal and ground DC 500V 20MΩ or more |
Data backup using non-volatile memory (approximately 10 years) | 1 point | Downscale (RTD input) | Upscale |
No external noise and no direct vibration or impact. A place that is not exposed to direct sunlight. |
Relay contact output | None (for control action F or D) | -1,999~+9,999℃ or -199.9~+999.9℃ | -span~+span | 45~85%RH | 0~50℃ | 0.5 seconds |
No corrosive or flammable gases, and no heavy dust. |
Waterproof and dustproof structure available | Approximately 170g |
Between measurement terminal and ground: AC 1,000V for 1 minute Between power terminal and ground: AC 1,500V for 1 minute |
|
CB100FK01-M*NA-NN/N |
Available upon quote | None | Upper limit deviation alarm |
CE marking compliant, UL, cUL certified product Compliant with RoHS Directive *The triac drive trigger output does not comply with or correspond to CE marking, UL, or cUL. |
White tone | None | PID operation (reverse operation) | Approx. 0.2μV/Ω (thermocouple input) | Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire | Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. | Thermocouple: K, 0~200℃ |
Between measurement terminal and ground DC 500V 20MΩ or more Between power terminal and ground DC 500V 20MΩ or more |
Data backup using non-volatile memory (approximately 10 years) | 1 point | Downscale (RTD input) | Upscale |
No external noise and no direct vibration or impact. A place that is not exposed to direct sunlight. |
Relay contact output | None (for control action F or D) | -1,999~+9,999℃ or -199.9~+999.9℃ | -span~+span | 45~85%RH | 0~50℃ | 0.5 seconds |
No corrosive or flammable gases, and no heavy dust. |
No waterproof/dustproof structure | Approximately 170g |
Between measurement terminal and ground: AC 1,000V for 1 minute Between power terminal and ground: AC 1,500V for 1 minute |
|
CB100FK01-M*NA-NN/A |
Available upon quote | None | Upper limit deviation alarm |
CE marking compliant, UL, cUL certified product Compliant with RoHS Directive *The triac drive trigger output does not comply with or correspond to CE marking, UL, or cUL. |
Black tone | None | PID operation (reverse operation) | Approx. 0.2μV/Ω (thermocouple input) | Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire | Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. | Thermocouple: K, 0~200℃ |
Between measurement terminal and ground DC 500V 20MΩ or more Between power terminal and ground DC 500V 20MΩ or more |
Data backup using non-volatile memory (approximately 10 years) | 1 point | Downscale (RTD input) | Upscale |
No external noise and no direct vibration or impact. A place that is not exposed to direct sunlight. |
Relay contact output | None (for control action F or D) | -1,999~+9,999℃ or -199.9~+999.9℃ | -span~+span | 45~85%RH | 0~50℃ | 0.5 seconds |
No corrosive or flammable gases, and no heavy dust. |
No waterproof/dustproof structure | Approximately 170g |
Between measurement terminal and ground: AC 1,000V for 1 minute Between power terminal and ground: AC 1,500V for 1 minute |
|
CB100FK01-M*NA-N1/A |
Available upon quote | None | Upper limit deviation alarm |
CE marking compliant, UL, cUL certified product Compliant with RoHS Directive *The triac drive trigger output does not comply with or correspond to CE marking, UL, or cUL. |
Black tone | None | PID operation (reverse operation) | Approx. 0.2μV/Ω (thermocouple input) | Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire | Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. | Thermocouple: K, 0~200℃ |
Between measurement terminal and ground DC 500V 20MΩ or more Between power terminal and ground DC 500V 20MΩ or more |
Data backup using non-volatile memory (approximately 10 years) | 1 point | Downscale (RTD input) | Upscale |
No external noise and no direct vibration or impact. A place that is not exposed to direct sunlight. |
Relay contact output | None (for control action F or D) | -1,999~+9,999℃ or -199.9~+999.9℃ | -span~+span | 45~85%RH | 0~50℃ | 0.5 seconds |
No corrosive or flammable gases, and no heavy dust. |
Waterproof and dustproof structure available | Approximately 170g |
Between measurement terminal and ground: AC 1,000V for 1 minute Between power terminal and ground: AC 1,500V for 1 minute |
|
CB100FK01-M*NA-5N/N |
Available upon quote | None | Upper limit deviation alarm |
CE marking compliant, UL, cUL certified product Compliant with RoHS Directive *The triac drive trigger output does not comply with or correspond to CE marking, UL, or cUL. |
White tone | RS-485 (RKC standard protocol) | PID operation (reverse operation) | Approx. 0.2μV/Ω (thermocouple input) | Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire | Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. | Thermocouple: K, 0~200℃ |
Between measurement terminal and ground DC 500V 20MΩ or more Between power terminal and ground DC 500V 20MΩ or more |
Data backup using non-volatile memory (approximately 10 years) | 1 point | Downscale (RTD input) | Upscale |
No external noise and no direct vibration or impact. A place that is not exposed to direct sunlight. |
Relay contact output | None (for control action F or D) | -1,999~+9,999℃ or -199.9~+999.9℃ | -span~+span | 45~85%RH | 0~50℃ | 0.5 seconds |
No corrosive or flammable gases, and no heavy dust. |
No waterproof/dustproof structure | Approximately 170g |
Between measurement terminal and ground: AC 1,000V for 1 minute Between power terminal and ground: AC 1,500V for 1 minute |
Click on the part number for more information about each product