Digital indicating controller (temperature controller) CB seriesHandling Company
RKC INSTRUMENTCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Waterproof and dustproof structure | Weight | Applicable standards | Communication function | Permissible ambient humidity | Permissible ambient temperature | Withstand voltage | Insulation resistance | 2nd alarm | 1st alarm | Body color | Effect of external resistance | Control operation | Output 2 (OUT2) Control output | Output 1 (OUT1) Control output | Operation during input short circuit | Number of input points | Effect of input lead resistance | Input/range | Effects of power outage | Usage atmosphere | Memory backup | Sampling period | Other conditions | Operation when input wire is disconnected | PV bias When voltage/current input | PV bias When temperature input |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CB100FK01-M*NN-NN/N |
Available upon quote |
No waterproof/dustproof structure |
Approximately 170g |
CE marking compliant, UL, cUL certified product |
None |
45~85%RH |
0~50℃ |
Between measurement terminal and ground: AC 1,000V for 1 minute |
Between measurement terminal and ground DC 500V 20MΩ or more |
None |
None |
White tone |
Approx. 0.2μV/Ω (thermocouple input) |
PID operation (reverse operation) |
None (for control action F or D) |
Relay contact output |
Downscale (RTD input) |
1 point |
Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire |
Thermocouple: K, 0~200℃ |
Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. |
No corrosive or flammable gases, and no heavy dust. |
Data backup using non-volatile memory (approximately 10 years) |
0.5 seconds |
No external noise and no direct vibration or impact. |
Upscale |
-span~+span |
-1,999~+9,999℃ or -199.9~+999.9℃ |
|
CB100FK01-M*NN-NN/A |
Available upon quote |
No waterproof/dustproof structure |
Approximately 170g |
CE marking compliant, UL, cUL certified product |
None |
45~85%RH |
0~50℃ |
Between measurement terminal and ground: AC 1,000V for 1 minute |
Between measurement terminal and ground DC 500V 20MΩ or more |
None |
None |
Black tone |
Approx. 0.2μV/Ω (thermocouple input) |
PID operation (reverse operation) |
None (for control action F or D) |
Relay contact output |
Downscale (RTD input) |
1 point |
Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire |
Thermocouple: K, 0~200℃ |
Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. |
No corrosive or flammable gases, and no heavy dust. |
Data backup using non-volatile memory (approximately 10 years) |
0.5 seconds |
No external noise and no direct vibration or impact. |
Upscale |
-span~+span |
-1,999~+9,999℃ or -199.9~+999.9℃ |
|
CB100FK01-M*NN-N1/A |
Available upon quote |
Waterproof and dustproof structure available |
Approximately 170g |
CE marking compliant, UL, cUL certified product |
None |
45~85%RH |
0~50℃ |
Between measurement terminal and ground: AC 1,000V for 1 minute |
Between measurement terminal and ground DC 500V 20MΩ or more |
None |
None |
Black tone |
Approx. 0.2μV/Ω (thermocouple input) |
PID operation (reverse operation) |
None (for control action F or D) |
Relay contact output |
Downscale (RTD input) |
1 point |
Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire |
Thermocouple: K, 0~200℃ |
Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. |
No corrosive or flammable gases, and no heavy dust. |
Data backup using non-volatile memory (approximately 10 years) |
0.5 seconds |
No external noise and no direct vibration or impact. |
Upscale |
-span~+span |
-1,999~+9,999℃ or -199.9~+999.9℃ |
|
CB100FK01-M*NN-5N/N |
Available upon quote |
No waterproof/dustproof structure |
Approximately 170g |
CE marking compliant, UL, cUL certified product |
RS-485 (RKC standard protocol) |
45~85%RH |
0~50℃ |
Between measurement terminal and ground: AC 1,000V for 1 minute |
Between measurement terminal and ground DC 500V 20MΩ or more |
None |
None |
White tone |
Approx. 0.2μV/Ω (thermocouple input) |
PID operation (reverse operation) |
None (for control action F or D) |
Relay contact output |
Downscale (RTD input) |
1 point |
Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire |
Thermocouple: K, 0~200℃ |
Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. |
No corrosive or flammable gases, and no heavy dust. |
Data backup using non-volatile memory (approximately 10 years) |
0.5 seconds |
No external noise and no direct vibration or impact. |
Upscale |
-span~+span |
-1,999~+9,999℃ or -199.9~+999.9℃ |
|
CB100FK01-M*NN-5N/A |
Available upon quote |
No waterproof/dustproof structure |
Approximately 170g |
CE marking compliant, UL, cUL certified product |
RS-485 (RKC standard protocol) |
45~85%RH |
0~50℃ |
Between measurement terminal and ground: AC 1,000V for 1 minute |
Between measurement terminal and ground DC 500V 20MΩ or more |
None |
None |
Black tone |
Approx. 0.2μV/Ω (thermocouple input) |
PID operation (reverse operation) |
None (for control action F or D) |
Relay contact output |
Downscale (RTD input) |
1 point |
Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire |
Thermocouple: K, 0~200℃ |
Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. |
No corrosive or flammable gases, and no heavy dust. |
Data backup using non-volatile memory (approximately 10 years) |
0.5 seconds |
No external noise and no direct vibration or impact. |
Upscale |
-span~+span |
-1,999~+9,999℃ or -199.9~+999.9℃ |
|
CB100FK01-M*NN-51/A |
Available upon quote |
Waterproof and dustproof structure available |
Approximately 170g |
CE marking compliant, UL, cUL certified product |
RS-485 (RKC standard protocol) |
45~85%RH |
0~50℃ |
Between measurement terminal and ground: AC 1,000V for 1 minute |
Between measurement terminal and ground DC 500V 20MΩ or more |
None |
None |
Black tone |
Approx. 0.2μV/Ω (thermocouple input) |
PID operation (reverse operation) |
None (for control action F or D) |
Relay contact output |
Downscale (RTD input) |
1 point |
Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire |
Thermocouple: K, 0~200℃ |
Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. |
No corrosive or flammable gases, and no heavy dust. |
Data backup using non-volatile memory (approximately 10 years) |
0.5 seconds |
No external noise and no direct vibration or impact. |
Upscale |
-span~+span |
-1,999~+9,999℃ or -199.9~+999.9℃ |
|
CB100FK01-M*NA-NN/N |
Available upon quote |
No waterproof/dustproof structure |
Approximately 170g |
CE marking compliant, UL, cUL certified product |
None |
45~85%RH |
0~50℃ |
Between measurement terminal and ground: AC 1,000V for 1 minute |
Between measurement terminal and ground DC 500V 20MΩ or more |
Upper limit deviation alarm |
None |
White tone |
Approx. 0.2μV/Ω (thermocouple input) |
PID operation (reverse operation) |
None (for control action F or D) |
Relay contact output |
Downscale (RTD input) |
1 point |
Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire |
Thermocouple: K, 0~200℃ |
Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. |
No corrosive or flammable gases, and no heavy dust. |
Data backup using non-volatile memory (approximately 10 years) |
0.5 seconds |
No external noise and no direct vibration or impact. |
Upscale |
-span~+span |
-1,999~+9,999℃ or -199.9~+999.9℃ |
|
CB100FK01-M*NA-NN/A |
Available upon quote |
No waterproof/dustproof structure |
Approximately 170g |
CE marking compliant, UL, cUL certified product |
None |
45~85%RH |
0~50℃ |
Between measurement terminal and ground: AC 1,000V for 1 minute |
Between measurement terminal and ground DC 500V 20MΩ or more |
Upper limit deviation alarm |
None |
Black tone |
Approx. 0.2μV/Ω (thermocouple input) |
PID operation (reverse operation) |
None (for control action F or D) |
Relay contact output |
Downscale (RTD input) |
1 point |
Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire |
Thermocouple: K, 0~200℃ |
Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. |
No corrosive or flammable gases, and no heavy dust. |
Data backup using non-volatile memory (approximately 10 years) |
0.5 seconds |
No external noise and no direct vibration or impact. |
Upscale |
-span~+span |
-1,999~+9,999℃ or -199.9~+999.9℃ |
|
CB100FK01-M*NA-N1/A |
Available upon quote |
Waterproof and dustproof structure available |
Approximately 170g |
CE marking compliant, UL, cUL certified product |
None |
45~85%RH |
0~50℃ |
Between measurement terminal and ground: AC 1,000V for 1 minute |
Between measurement terminal and ground DC 500V 20MΩ or more |
Upper limit deviation alarm |
None |
Black tone |
Approx. 0.2μV/Ω (thermocouple input) |
PID operation (reverse operation) |
None (for control action F or D) |
Relay contact output |
Downscale (RTD input) |
1 point |
Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire |
Thermocouple: K, 0~200℃ |
Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. |
No corrosive or flammable gases, and no heavy dust. |
Data backup using non-volatile memory (approximately 10 years) |
0.5 seconds |
No external noise and no direct vibration or impact. |
Upscale |
-span~+span |
-1,999~+9,999℃ or -199.9~+999.9℃ |
|
CB100FK01-M*NA-5N/N |
Available upon quote |
No waterproof/dustproof structure |
Approximately 170g |
CE marking compliant, UL, cUL certified product |
RS-485 (RKC standard protocol) |
45~85%RH |
0~50℃ |
Between measurement terminal and ground: AC 1,000V for 1 minute |
Between measurement terminal and ground DC 500V 20MΩ or more |
Upper limit deviation alarm |
None |
White tone |
Approx. 0.2μV/Ω (thermocouple input) |
PID operation (reverse operation) |
None (for control action F or D) |
Relay contact output |
Downscale (RTD input) |
1 point |
Approximately 0.01 [%/Ω] of reading value (RTD input) *Maximum within 10Ω per wire |
Thermocouple: K, 0~200℃ |
Power outages of 20msec or less will not affect operation. *Any further power outage will result in the initial state. |
No corrosive or flammable gases, and no heavy dust. |
Data backup using non-volatile memory (approximately 10 years) |
0.5 seconds |
No external noise and no direct vibration or impact. |
Upscale |
-span~+span |
-1,999~+9,999℃ or -199.9~+999.9℃ |
Click on the part number for more information about each product