Digital indicating controller (temperature controller) SA200-SA200FK01-MN-3*NN-NN/N
Digital indicating controller (temperature controller) SA200-RKC INSTRUMENT

Digital indicating controller (temperature controller) SA200
RKC INSTRUMENT


About This Product

■SA200 ・A wealth of functions in a small body - Close-contact instrumentation is possible. A true space-saving temperature controller ・Simultaneous display of measured temperature and set value ■48 (horizontal) x 24 (vertical) mm size compact temperature controller ・A small controller that can be installed even on narrow installation surfaces. -Equipped with a large PV display that is small but highly visible. ■Equipped with control status discrimination type self-tuning function - Automatically tunes PID constants when it is determined that control is disrupted. -Auto tuning function is also available. ■Communication function (RS-485) can be installed (optional) - Communication function (RS-485) allows multi-drop connection of up to 31 units. - RKC standard and MODBUS protocol can be selected. ■Transmission output can be added (optional) One transmission output point can be added for convenient connection with external equipment. *Output is possible by assigning transmission output to output 1 (OUT1). ■Two types available: black base tone and white base tone. Two types are available, one with a black tone and one with a white tone, to match the device. ■e-CON connector connection type SA220 available ・This is a controller that is wired with an e-CON connector. ・Wiring man-hours can be reduced compared to terminal block wiring. *Some functions are limited compared to SA200 ■Applicable standards ・UL: UL61010-1 ・C-UL:CAN/CSA-C22.2 NO.61010-1 ・CE marking a) Low voltage directive: EN61010-1, b) EMC directive: EN61326-1, C) RoHS directive: EN IEC 63000 ・RCM: EN55011 ・UKCA marking a) Electrical equipment safety regulations: EN61010-1, b) EMC regulations: EN61326-1, C) RoHS regulations: EN IEC 63000 *Other product numbers are available.

  • Product

    Digital indicating controller (temperature controller) SA200

Share this product


200+ people viewing

Last viewed: 18 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Digital indicating controller (temperature controller) SA200

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Alarm 1 type Alarm 2 type Applicable standards Basic type Body color Control operation Digital filter Effect of external resistance Effects of power outage External dimensions Input/range Insulation resistance LCD display Mass Measurement accuracy Memory backup Number of input points Operation when input is disconnected Option Other conditions Output 1 (control output or alarm output) Output 2 (control output or alarm output) PV bias Permissible ambient humidity Permissible ambient temperature Power supply voltage Sampling period Usage atmosphere Waterproof dustproof Withstand voltage
Digital indicating controller (temperature controller) SA200-Part Number-SA200FK01-MN-3*NN-NN/N

SA200FK01-MN-3*NN-NN/N

Available upon quote No alarm function No alarm function UL: UL61010-1
C-UL: CAN/CSA-C22.2 NO.61010-1
48×24mm size temperature controller White tone PID operation with AT (reverse operation) 1~100 seconds (when set to 0: OFF) Approximately 0.2μV/Ω Power outages of 20msec or less will not affect operation. 48×24×100mm (width x length x depth) Thermocouple: K (JIS/IEC)
Range range: 0~200℃
Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Temperature measurement value (PV): Green display
Temperature set value (SV): Orange display
AT・OUT1/2: Green display
SV2・ALM1/2: Orange display
Approximately 110g ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (data storage retention period approximately 10 years) 1 point Upscale No optional features No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Relay contact output No output -Span~+Span (within -1,999~+9,999digit) 5~95%RH (no condensation) -10~+55℃ AC/DC 24V 0.5 seconds (switchable to 0.25 seconds) No corrosive or flammable gases, and no heavy dust. No waterproof/dustproof structure Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicating controller (temperature controller) SA200-Part Number-SA200FK01-MN-3*NN-NN/A

SA200FK01-MN-3*NN-NN/A

Available upon quote No alarm function No alarm function UL: UL61010-1
C-UL: CAN/CSA-C22.2 NO.61010-1
48×24mm size temperature controller Black tone PID operation with AT (reverse operation) 1~100 seconds (when set to 0: OFF) Approximately 0.2μV/Ω Power outages of 20msec or less will not affect operation. 48×24×100mm (width x length x depth) Thermocouple: K (JIS/IEC)
Range range: 0~200℃
Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Temperature measurement value (PV): Green display
Temperature set value (SV): Orange display
AT・OUT1/2: Green display
SV2・ALM1/2: Orange display
Approximately 110g ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (data storage retention period approximately 10 years) 1 point Upscale No optional features No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Relay contact output No output -Span~+Span (within -1,999~+9,999digit) 5~95%RH (no condensation) -10~+55℃ AC/DC 24V 0.5 seconds (switchable to 0.25 seconds) No corrosive or flammable gases, and no heavy dust. No waterproof/dustproof structure Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicating controller (temperature controller) SA200-Part Number-SA200FK01-MN-3*NN-N1/N

SA200FK01-MN-3*NN-N1/N

Available upon quote No alarm function No alarm function UL: UL61010-1
C-UL: CAN/CSA-C22.2 NO.61010-1
48×24mm size temperature controller White tone PID operation with AT (reverse operation) 1~100 seconds (when set to 0: OFF) Approximately 0.2μV/Ω Power outages of 20msec or less will not affect operation. 48×24×100mm (width x length x depth) Thermocouple: K (JIS/IEC)
Range range: 0~200℃
Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Temperature measurement value (PV): Green display
Temperature set value (SV): Orange display
AT・OUT1/2: Green display
SV2・ALM1/2: Orange display
Approximately 110g ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (data storage retention period approximately 10 years) 1 point Upscale No optional features No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Relay contact output No output -Span~+Span (within -1,999~+9,999digit) 5~95%RH (no condensation) -10~+55℃ AC/DC 24V 0.5 seconds (switchable to 0.25 seconds) No corrosive or flammable gases, and no heavy dust. Waterproof and dustproof structure available Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicating controller (temperature controller) SA200-Part Number-SA200FK01-MN-3*NN-N1/A

SA200FK01-MN-3*NN-N1/A

Available upon quote No alarm function No alarm function UL: UL61010-1
C-UL: CAN/CSA-C22.2 NO.61010-1
48×24mm size temperature controller Black tone PID operation with AT (reverse operation) 1~100 seconds (when set to 0: OFF) Approximately 0.2μV/Ω Power outages of 20msec or less will not affect operation. 48×24×100mm (width x length x depth) Thermocouple: K (JIS/IEC)
Range range: 0~200℃
Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Temperature measurement value (PV): Green display
Temperature set value (SV): Orange display
AT・OUT1/2: Green display
SV2・ALM1/2: Orange display
Approximately 110g ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (data storage retention period approximately 10 years) 1 point Upscale No optional features No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Relay contact output No output -Span~+Span (within -1,999~+9,999digit) 5~95%RH (no condensation) -10~+55℃ AC/DC 24V 0.5 seconds (switchable to 0.25 seconds) No corrosive or flammable gases, and no heavy dust. Waterproof and dustproof structure available Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicating controller (temperature controller) SA200-Part Number-SA200FK01-MN-3*NN-5N/N

SA200FK01-MN-3*NN-5N/N

Available upon quote No alarm function No alarm function UL: UL61010-1
C-UL: CAN/CSA-C22.2 NO.61010-1
48×24mm size temperature controller White tone PID operation with AT (reverse operation) 1~100 seconds (when set to 0: OFF) Approximately 0.2μV/Ω Power outages of 20msec or less will not affect operation. 48×24×100mm (width x length x depth) Thermocouple: K (JIS/IEC)
Range range: 0~200℃
Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Temperature measurement value (PV): Green display
Temperature set value (SV): Orange display
AT・OUT1/2: Green display
SV2・ALM1/2: Orange display
Approximately 110g ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (data storage retention period approximately 10 years) 1 point Upscale Communication function: RS-485 compliant (RKC standard) No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Relay contact output No output -Span~+Span (within -1,999~+9,999digit) 5~95%RH (no condensation) -10~+55℃ AC/DC 24V 0.5 seconds (switchable to 0.25 seconds) No corrosive or flammable gases, and no heavy dust. No waterproof/dustproof structure Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicating controller (temperature controller) SA200-Part Number-SA200FK01-MN-3*NN-5N/A

SA200FK01-MN-3*NN-5N/A

Available upon quote No alarm function No alarm function UL: UL61010-1
C-UL: CAN/CSA-C22.2 NO.61010-1
48×24mm size temperature controller Black tone PID operation with AT (reverse operation) 1~100 seconds (when set to 0: OFF) Approximately 0.2μV/Ω Power outages of 20msec or less will not affect operation. 48×24×100mm (width x length x depth) Thermocouple: K (JIS/IEC)
Range range: 0~200℃
Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Temperature measurement value (PV): Green display
Temperature set value (SV): Orange display
AT・OUT1/2: Green display
SV2・ALM1/2: Orange display
Approximately 110g ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (data storage retention period approximately 10 years) 1 point Upscale Communication function: RS-485 compliant (RKC standard) No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Relay contact output No output -Span~+Span (within -1,999~+9,999digit) 5~95%RH (no condensation) -10~+55℃ AC/DC 24V 0.5 seconds (switchable to 0.25 seconds) No corrosive or flammable gases, and no heavy dust. No waterproof/dustproof structure Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicating controller (temperature controller) SA200-Part Number-SA200FK01-MN-3*NN-51/N

SA200FK01-MN-3*NN-51/N

Available upon quote No alarm function No alarm function UL: UL61010-1
C-UL: CAN/CSA-C22.2 NO.61010-1
48×24mm size temperature controller White tone PID operation with AT (reverse operation) 1~100 seconds (when set to 0: OFF) Approximately 0.2μV/Ω Power outages of 20msec or less will not affect operation. 48×24×100mm (width x length x depth) Thermocouple: K (JIS/IEC)
Range range: 0~200℃
Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Temperature measurement value (PV): Green display
Temperature set value (SV): Orange display
AT・OUT1/2: Green display
SV2・ALM1/2: Orange display
Approximately 110g ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (data storage retention period approximately 10 years) 1 point Upscale Communication function: RS-485 compliant (RKC standard) No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Relay contact output No output -Span~+Span (within -1,999~+9,999digit) 5~95%RH (no condensation) -10~+55℃ AC/DC 24V 0.5 seconds (switchable to 0.25 seconds) No corrosive or flammable gases, and no heavy dust. Waterproof and dustproof structure available Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicating controller (temperature controller) SA200-Part Number-SA200FK01-MN-3*NN-51/A

SA200FK01-MN-3*NN-51/A

Available upon quote No alarm function No alarm function UL: UL61010-1
C-UL: CAN/CSA-C22.2 NO.61010-1
48×24mm size temperature controller Black tone PID operation with AT (reverse operation) 1~100 seconds (when set to 0: OFF) Approximately 0.2μV/Ω Power outages of 20msec or less will not affect operation. 48×24×100mm (width x length x depth) Thermocouple: K (JIS/IEC)
Range range: 0~200℃
Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Temperature measurement value (PV): Green display
Temperature set value (SV): Orange display
AT・OUT1/2: Green display
SV2・ALM1/2: Orange display
Approximately 110g ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (data storage retention period approximately 10 years) 1 point Upscale Communication function: RS-485 compliant (RKC standard) No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Relay contact output No output -Span~+Span (within -1,999~+9,999digit) 5~95%RH (no condensation) -10~+55℃ AC/DC 24V 0.5 seconds (switchable to 0.25 seconds) No corrosive or flammable gases, and no heavy dust. Waterproof and dustproof structure available Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicating controller (temperature controller) SA200-Part Number-SA200FK01-MN-3*NN-6N/N

SA200FK01-MN-3*NN-6N/N

Available upon quote No alarm function No alarm function UL: UL61010-1
C-UL: CAN/CSA-C22.2 NO.61010-1
48×24mm size temperature controller White tone PID operation with AT (reverse operation) 1~100 seconds (when set to 0: OFF) Approximately 0.2μV/Ω Power outages of 20msec or less will not affect operation. 48×24×100mm (width x length x depth) Thermocouple: K (JIS/IEC)
Range range: 0~200℃
Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Temperature measurement value (PV): Green display
Temperature set value (SV): Orange display
AT・OUT1/2: Green display
SV2・ALM1/2: Orange display
Approximately 110g ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (data storage retention period approximately 10 years) 1 point Upscale Communication function: RS-485 compliant (MODBUS) No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Relay contact output No output -Span~+Span (within -1,999~+9,999digit) 5~95%RH (no condensation) -10~+55℃ AC/DC 24V 0.5 seconds (switchable to 0.25 seconds) No corrosive or flammable gases, and no heavy dust. No waterproof/dustproof structure Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute
Digital indicating controller (temperature controller) SA200-Part Number-SA200FK01-MN-3*NN-6N/A

SA200FK01-MN-3*NN-6N/A

Available upon quote No alarm function No alarm function UL: UL61010-1
C-UL: CAN/CSA-C22.2 NO.61010-1
48×24mm size temperature controller Black tone PID operation with AT (reverse operation) 1~100 seconds (when set to 0: OFF) Approximately 0.2μV/Ω Power outages of 20msec or less will not affect operation. 48×24×100mm (width x length x depth) Thermocouple: K (JIS/IEC)
Range range: 0~200℃
Between measurement terminal and ground: DC 500V 20MΩ or more
Between power terminal and ground: DC 500V 20MΩ or more
Temperature measurement value (PV): Green display
Temperature set value (SV): Orange display
AT・OUT1/2: Green display
SV2・ALM1/2: Orange display
Approximately 110g ± (0.3% of display value + 1 digit) or ±2℃ (within whichever is larger) Data backup using non-volatile memory (data storage retention period approximately 10 years) 1 point Upscale Communication function: RS-485 compliant (MODBUS) No external noise and no direct vibration or impact.
A place that is not exposed to direct sunlight.
Relay contact output No output -Span~+Span (within -1,999~+9,999digit) 5~95%RH (no condensation) -10~+55℃ AC/DC 24V 0.5 seconds (switchable to 0.25 seconds) No corrosive or flammable gases, and no heavy dust. No waterproof/dustproof structure Between measurement terminal and ground: AC 1,500V for 1 minute
Between power terminal and ground: AC 1,500V for 1 minute

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of RKC INSTRUMENT


View more products of RKC INSTRUMENT

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree