All Categories

History

Scroll/FOSSA-Fossa fo 0015 a (a) 50Hz
Scroll/FOSSA-BUSCH VACUUM SOLUTIONS

BUSCH VACUUM SOLUTIONS's Response Status

Response Rate

100.0%

Response Time

55.3hours


About This Product

Scroll vacuum pump The design of the FOSSA scrolling vacuum pump adopts the latest single -side scrolling technology. It is a product that combines a dry compression system and a high airtight structure. Low noise and low vibration make it optimal for analysis and scientific applications in the middle vacuum region. It has been highly evaluated by many years of achievements in these fields. Operating principle The FOSSA scrolling vacuum pump is composed of a pair of fixation and turning scrolling. The turning scroll moves in a fixed scroll. If a space is formed on the outer periphery due to the movement of the turning scroll, gas is taken in from the intake port. The turning continues, and the gas captured between scrolling is transferred toward the inner periphery. Eventually, it is discharged from the exhaust port at the center of the two scrolling. FOSSA FO series benefits The FOSSA FO Scroll vacuum pump has all conditions required for today's analysis and scientific applications. Ideal solution for gas collection and precious gas, helium -like questtors, coating systems, or turbo molecular pump back pumps. The high airtight structure achieves completely dry and reliable compression. Metal bellows and static seals ensure the airtightness between the sucking gas and the surrounding air, preventing process gas pollution and leak. FOSSA FO has little maintenance because there is no shaft seal and a lifetime lubricating bearing is adopted. The only service work you need is scrolling chip seal replacement. Since the replacement is easy and there is no special tool, you can do it yourself at the location you use. Low noise and low vibration, it is also suitable for use in quiet environments. Highly airtightness suitable for analysis and scientific applications ・ High airtight structure ・ Quiet driving sound ・ Minimum operating cost ・ Minimum maintenance ・ Dry driving

  • Product

    Scroll/FOSSA

Share this product


600+ people viewing

Last viewed: 11 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

12 Models of Scroll/FOSSA

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Leak rate (helium) Achievement vacuum (when the gas ballast valve is closed) Achievement vacuum (when the gas ballast valve is open) Rated motor output Operating voltage Maximum continuous intake pressure Rated motor rotation speed Exhaust speed (m³/h) Exhaust speed (L/min) Steamed steam tolerance (when the gas ballast valve is opened) Noise value (ISO2151) External dimensions (LXWXH) mass Ambient temperature Maximum back pressure Gas outlet Gas -inlet safety Emotions and images Vibration level of the intake part (ISO10816-1)
Scroll/FOSSA-Part Number-Fossa fo 0015 a (a) 50Hz

Fossa fo 0015 a (a) 50Hz

Available upon quote

<1 ・ 10⁻⁶mbar · L/S

0.025HPa (MBAR)

0.09HPa (MBAR)

0.4kw

100 --240V

1000HPa (MBAR) Rel.

1480min⁻¹

15m³/h

250L/min

300g/h

42db (a) (idling mode)/59db (A) (maximum) DB (a)

450x338x369mm

48kg

5–40 ° C

500HPa (MBAR) Rel.

DN16ISO-KF

DN40ISO-KF

En/IEC61010 3rd edition

EN61236-1: 2013, Device Class A

Class 1b, <1.5mm · S⁻¹

Scroll/FOSSA-Part Number-Fossa fo 0015 a (a) 60Hz

Fossa fo 0015 a (a) 60Hz

Available upon quote

<1 ・ 10⁻⁶mbar · L/S

0.025HPa (MBAR)

0.09HPa (MBAR)

0.4kw

100 --240V

1000HPa (MBAR) Rel.

1780min⁻¹

18m³/h

300L/min

300g/h

42db (a) (idling mode)/59db (A) (maximum) DB (a)

450x338x369mm

48kg

5–40 ° C

500HPa (MBAR) Rel.

DN16ISO-KF

DN40ISO-KF

En/IEC61010 3rd edition

EN61236-1: 2013, Device Class A

Class 1b, <1.5mm · S⁻¹

Scroll/FOSSA-Part Number-Fossa fo 0015 a (b) 50Hz

Fossa fo 0015 a (b) 50Hz

Available upon quote

<1 ・ 10⁻⁶mbar · L/S

0.025HPa (MBAR)

0.09HPa (MBAR)

0.4kw

190–220V

1000HPa (MBAR) Rel.

1480min⁻¹

15m³/h

250L/min

300g/h

42db (a) (idling mode)/59db (A) (maximum) DB (a)

450x338x369mm

48kg

5–40 ° C

500HPa (MBAR) Rel.

DN16ISO-KF

DN40ISO-KF

En/IEC61010 3rd edition

EN61236-1: 2013, Device Class A

Class 1b, <1.5mm · S⁻¹

Scroll/FOSSA-Part Number-Fossa fo 0015 a (b) 60Hz

Fossa fo 0015 a (b) 60Hz

Available upon quote

<1 ・ 10⁻⁶mbar · L/S

0.025HPa (MBAR)

0.09HPa (MBAR)

0.4kw

190–220V

1000HPa (MBAR) Rel.

1780min⁻¹

18m³/h

300L/min

300g/h

42db (a) (idling mode)/59db (A) (maximum) DB (a)

450x338x369mm

48kg

5–40 ° C

500HPa (MBAR) Rel.

DN16ISO-KF

DN40ISO-KF

En/IEC61010 3rd edition

EN61236-1: 2013, Device Class A

Class 1b, <1.5mm · S⁻¹

Scroll/FOSSA-Part Number-Fossa fo 0015 a (c) 50Hz

Fossa fo 0015 a (c) 50Hz

Available upon quote

<1 ・ 10⁻⁶mbar · L/S

0.025HPa (MBAR)

0.09HPa (MBAR)

0.4kw

100 --115V

1000HPa (MBAR) Rel.

1480min⁻¹

15m³/h

250L/min

300g/h

42db (a) (idling mode)/59db (A) (maximum) DB (a)

450x338x369mm

48kg

5–40 ° C

500HPa (MBAR) Rel.

DN16ISO-KF

DN40ISO-KF

En/IEC61010 3rd edition

EN61236-1: 2013, Device Class A

Class 1b, <1.5mm · S⁻¹

Scroll/FOSSA-Part Number-Fossa fo 0015 a (c) 60Hz

Fossa fo 0015 a (c) 60Hz

Available upon quote

<1 ・ 10⁻⁶mbar · L/S

0.025HPa (MBAR)

0.09HPa (MBAR)

0.4kw

100 --115V

1000HPa (MBAR) Rel.

1780min⁻¹

18m³/h

300L/min

300g/h

42db (a) (idling mode)/59db (A) (maximum) DB (a)

450x338x369mm

48kg

5–40 ° C

500HPa (MBAR) Rel.

DN16ISO-KF

DN40ISO-KF

En/IEC61010 3rd edition

EN61236-1: 2013, Device Class A

Class 1b, <1.5mm · S⁻¹

Scroll/FOSSA-Part Number-Fossa fo 0015 a (d) 50Hz

Fossa fo 0015 a (d) 50Hz

Available upon quote

<1 ・ 10⁻⁶mbar · L/S

0.025HPa (MBAR)

0.09HPa (MBAR)

0.4kw

200 --240V

1000HPa (MBAR) Rel.

1480min⁻¹

15m³/h

250L/min

300g/h

42db (a) (idling mode)/59db (A) (maximum) DB (a)

450x338x369mm

48kg

5–40 ° C

500HPa (MBAR) Rel.

DN16ISO-KF

DN40ISO-KF

En/IEC61010 3rd edition

EN61236-1: 2013, Device Class A

Class 1b, <1.5mm · S⁻¹

Scroll/FOSSA-Part Number-Fossa fo 0015 a (d) 60Hz

Fossa fo 0015 a (d) 60Hz

Available upon quote

<1 ・ 10⁻⁶mbar · L/S

0.025HPa (MBAR)

0.09HPa (MBAR)

0.4kw

200 --240V

1000HPa (MBAR) Rel.

1780min⁻¹

18m³/h

300L/min

300g/h

42db (a) (idling mode)/59db (A) (maximum) DB (a)

450x338x369mm

48kg

5–40 ° C

500HPa (MBAR) Rel.

DN16ISO-KF

DN40ISO-KF

En/IEC61010 3rd edition

EN61236-1: 2013, Device Class A

Class 1b, <1.5mm · S⁻¹

Scroll/FOSSA-Part Number-Fo 0035 B (a) 50Hz

Fo 0035 B (a) 50Hz

Available upon quote

<1 ・ 10⁻⁶mbar · L/S

0.01HPa (MBAR)

0.09HPa (MBAR)

0.75kW

100 --240V

100HPa (MBAR) Rel.

1480min⁻¹

35m³/h

583L/min

400g/h

43db (a) (idling mode)/60db (a) (maximum) DB (a)

462x338x369mm

50kg

5–40 ° C

200HPa (MBAR) Rel.

DN16ISO-KF

DN40ISO-KF

En/IEC61010 3rd edition

EN61236-1: 2013, Device Class A

Class 1b, <1.5mm · S⁻¹

Scroll/FOSSA-Part Number-Fo 0035 B (a) 60Hz

Fo 0035 B (a) 60Hz

Available upon quote

<1 ・ 10⁻⁶mbar · L/S

0.01HPa (MBAR)

0.09HPa (MBAR)

0.75kW

100 --240V

100HPa (MBAR) Rel.

1780min⁻¹

42m³/h

700L/min

400g/h

43db (a) (idling mode)/60db (a) (maximum) DB (a)

462x338x369mm

50kg

5–40 ° C

200HPa (MBAR) Rel.

DN16ISO-KF

DN40ISO-KF

En/IEC61010 3rd edition

EN61236-1: 2013, Device Class A

Class 1b, <1.5mm · S⁻¹

Scroll/FOSSA-Part Number-Fossa fo 0035 B (B) 50Hz

Fossa fo 0035 B (B) 50Hz

Available upon quote

<1 ・ 10⁻⁶mbar · L/S

0.01HPa (MBAR)

0.09HPa (MBAR)

0.75kW

190-220/380–415V

100HPa (MBAR) Rel.

1480min⁻¹

35m³/h

583L/min

400g/h

43db (a) (idling mode)/60db (a) (maximum) DB (a)

462x338x369mm

50kg

5–40 ° C

200HPa (MBAR) Rel.

DN16ISO-KF

DN40ISO-KF

En/IEC61010 3rd edition

EN61236-1: 2013, Device Class A

Class 1b, <1.5mm · S⁻¹

Scroll/FOSSA-Part Number-Fossa fo 0035 B (B) 60Hz

Fossa fo 0035 B (B) 60Hz

Available upon quote

<1 ・ 10⁻⁶mbar · L/S

0.01HPa (MBAR)

0.09HPa (MBAR)

0.75kW

200-140/380 --480V

100HPa (MBAR) Rel.

1780min⁻¹

42m³/h

700L/min

400g/h

43db (a) (idling mode)/60db (a) (maximum) DB (a)

462x338x369mm

50kg

5–40 ° C

200HPa (MBAR) Rel.

DN16ISO-KF

DN40ISO-KF

En/IEC61010 3rd edition

EN61236-1: 2013, Device Class A

Class 1b, <1.5mm · S⁻¹

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Scroll Pump Products

Other products of BUSCH VACUUM SOLUTIONS

Reviews shown here are reviews of companies.


View more products of BUSCH VACUUM SOLUTIONS

About Company Handling This Product

Response Rate

100.0%


Response Time

55.3hrs

Company Overview

Busch Vacuum Solutions was founded in 1963 in Virginia Beach, Virginia, US, as a manufacturer of vacuum pumps ...

See More

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree