Product
Industrial power conditioner SUN2000Handling Company
Kyocera CorporationCategories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | External dimensions (mm) | Grid-connected protection device | Installation location | Insulation method | Islanding detection function | Mass | Maximum output follow-up control range | Number of phases | Other standard functions and performance | Output current distortion rate | Power conversion efficiency | Rated input voltage | Rated output | Rated output frequency | Rated output voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SUN2000-125KTL-JPH0 |
Available upon quote | W1,080×H700×D365 | AC undervoltage, AC overvoltage, grid frequency drop, grid frequency increase | Outdoor (wall-mounted) | Transformerless method | Passive method, active method | 88kg | DC500 ~ 1,500V | Three-phase three-wire system |
・Constant output power factor function ・Can also be installed in salt-damaged areas (excluding areas adjacent to rocky reefs) ・Natural heat dissipation ・9MPPT |
Total 5%, each 3% or less | 98.80% | DC900V | 125kW | 50/60Hz | AC550V | |
SUN2000-63KTL-JPM0 |
Available upon quote | W1,075×H555×D300 | AC undervoltage, AC overvoltage, grid frequency drop, grid frequency increase | Outdoor (wall-mounted) | Transformerless method | Passive method, active method | 71kg | DC200 ~ 1,000V | Three-phase three-wire system |
・Constant output power factor function ・Can also be installed in salt-damaged areas (excluding areas adjacent to rocky reefs) ・Natural heat dissipation ・6MPPT |
Total 5%, each 3% or less | 98.90% |
DC670V (for rated output voltage AC440V) DC720V (for rated output voltage AC480V) |
62.5kW | 50/60Hz | AC440V/480V | |
SUN2000-50KTL-NHM3 |
Available upon quote | W681×H530×D270 | AC undervoltage, AC overvoltage, grid frequency drop, grid frequency increase | Outdoor (wall-mounted) | Transformerless method | Passive method, active method | 48kg | DC200 ~ 1,000V | Three-phase three-wire system |
・Constant output power factor function ・Can also be installed in salt-damaged areas (excluding areas adjacent to rocky reefs) ・Natural heat dissipation ・4MPPT |
Total 5%, each 3% or less | 98.60% | DC650V (for rated output voltage AC420/440V) | 50kW | 50/60Hz | AC420V/440V/480V | |
SUN2000-20KTL-M3 |
Available upon quote | W681×H530×D270 | AC undervoltage, AC overvoltage, grid frequency drop, grid frequency increase | Outdoor (wall-mounted) | Transformerless method | Passive method, active method | 43kg | DC200 ~ 750V | Three-phase three-wire system |
・Constant output power factor function ・Can also be installed in salt-damaged areas (excluding areas adjacent to rocky reefs) ・Natural heat dissipation ・4MPPT |
Total 5%, each 3% or less | 97.60% | DC360V | 20kW | 50/60Hz | AC202V | |
SUN2000-4.95KTL-JPL1 |
Available upon quote | W365×H649×D159 | AC undervoltage, AC overvoltage, grid frequency drop, grid frequency increase | Outdoor (wall-mounted) | Transformerless method | Passive method, active method | 19kg | DC90V ~ 560V | Three-phase three-wire system |
・Constant output power factor function ・Can also be installed in salt-damaged areas (excluding areas adjacent to rocky reefs) ・Natural heat dissipation ・2MPPT |
Total 5%, each 3% or less | 97.00% | DC600V (450V indoor wiring, 600V outdoor wiring) | 4.95kW | 50/60Hz | AC202V |
Click on the part number for more information about each product