All Categories
History
Product
Wind turbine direct lightning detection device class II-2Handling Company
Otowa Electric Industry Co., Ltd.Image | Part Number | Price (excluding tax) | Power supply | Current detection frequency band | Applicable tower diameter | Mass | Number of records | Recorded content | Recording medium | Observation time | Display content | Power consumption | Minimum detection current value | Maximum measured current value | Time | Usage environment | Operating temperature range Main unit | Operating temperature range sensor (built-in GPS) | Sensor type | Alarm setting range | Alarm output |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
LDW−MS45 |
Available upon quote |
AC90~240V (50/60Hz), DC12V |
1kHz~100kHz ±3dB |
4.0~4.5m |
Body: approx. 4.0kg |
Up to 999 items |
Record number, lightning strike time, polarity, maximum current value, presence or absence of alarm output |
SD memory card (2GB) |
Approximately 0.6 seconds |
Record number, lightning strike time, polarity, maximum current value |
10W or less |
±1kA |
±100kA |
GPS (built into sensor) |
Outdoor: Sensor (built-in GPS) |
-20°C~+60°C |
-30°C~+60°C |
Magnetic field sensor |
1~10kA (1kA increments) |
No voltage when lightning strike is detected that exceeds the alarm current value |