Instantaneous voltage drop compensator (small capacity) SB series-YS10BC48C11A
Instantaneous voltage drop compensator (small capacity) SB series-Otowa Electric Industry Co., Ltd.

Instantaneous voltage drop compensator (small capacity) SB series
Otowa Electric Industry Co., Ltd.

Otowa Electric Industry Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

40.2hours


About This Product

■Features

1, Realization of miniaturization Approximately 1/4 volume and 1/7 mass compared to UPS. Significant reduction in size and weight can be achieved. Ideal for diversification, small investment, and can be incorporated into equipment. 2.Improved overcurrent capability A static switch with high overcurrent capability is used as the direct feed switch, achieving an overcurrent capability of 150% of the rated current for 1 minute and 20 times the rated current for 1 cycle (SB 3-phase 3-wire). Even in the unlikely event that a device failure occurs, the direct feed switch remains on and continues to supply commercial power to the load. 3. Uninterrupted switching By quickly turning off the switch and activating the bidirectional converter as soon as a momentary sag is detected, the system switches from commercial power supply to capacitor power supply, resulting in a smooth transition with almost no voltage fluctuations on the load side. It does not affect high-tech equipment. 4.SEMI standard compliant Conforms to SEMI-F47, which specifies voltage drop tolerance for semiconductor manufacturing equipment. 5.UL standard, CE mark compliant YS10BC48C11A, YS20BC72C11A, and YS20BC96C11A comply with UL standards and CE mark. 6.Save running costs There is no need to replace the battery for about 10 years, and it is maintenance-free, so running costs can be significantly reduced compared to UPS. (battery-less)

  • Product

    Instantaneous voltage drop compensator (small capacity) SB series

Share this product


520+ people viewing

Last viewed: 14 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

9 Models of Instantaneous voltage drop compensator (small capacity) SB series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Atmosphere Overcurrent capacity during commercial operation Mass Load power factor range Allowable input voltage range Momentary sag compensation time (at rated load) Repeated momentary sag withstand capacity Momentary sag switching time Vibration/shock Rated current Rated load power factor Rated capacity Rated frequency during compensation operation Rated frequency during commercial operation Rated frequency Rated output voltage during compensation operation Rated output voltage During commercial operation Rated input voltage Ambient humidity Ambient temperature Efficiency Cooling method Input capacity (including charging capacity) Storage ambient temperature Place of use AC output phase number AC input phase number Standard
Instantaneous voltage drop compensator (small capacity) SB series-Part Number-YS10BC48C11A

YS10BC48C11A

Available upon quote

A place free of dust (including conductive), smoke, corrosive gas (including disinfectants), flammable gas, steam, salt, and oil fumes.

150% of rated current (1 minute), 600% (1 cycle)

Approximately 52kg

Delay 0.7~1.0

93V~120V

1.0 seconds

10 seconds interval 100% voltage drop 0.3 seconds 5 times in a row

No interruption

A place where vibrations and shocks are not transmitted

48A

Delay 0.8

4.8kVA

AC input frequency ±1%

Depends on commercial input frequency

50/60Hz±5%

Commercial input voltage ±5%

Depends on utility input voltage

100V

30~90%RH (no condensation)

0℃~+40℃ (annual average below 30℃)

97% or more

Natural cooling

5.8kVA

0℃~+60℃

Indoor

Single phase 2 wire

Single phase 2 wire

JIS, NRTL certified (UL1012), CE marking compliant (LVD/EMC Directive)

Instantaneous voltage drop compensator (small capacity) SB series-Part Number-YS20BC72C11A

YS20BC72C11A

Available upon quote

A place free of dust (including conductive), smoke, corrosive gas (including disinfectants), flammable gas, steam, salt, and oil fumes.

150% of rated current (1 minute), 600% (1 cycle)

Approximately 56kg

Delay 0.7~1.0

186V~264V

1.0 seconds

10 seconds interval 100% voltage drop 0.3 seconds 5 times in a row

No interruption

A place where vibrations and shocks are not transmitted

36A

Delay 0.8

7.2kVA

AC input frequency ±1%

Depends on commercial input frequency

50/60Hz±5%

Commercial input voltage ±5%

Depends on utility input voltage

200V

30~90%RH (no condensation)

0℃~+40℃ (annual average below 30℃)

97% or more

Natural cooling

8.6kVA

0℃~+60℃

Indoor

Single phase 2 wire

Single phase 2 wire

JIS, NRTL certified (UL1012), CE marking compliant (LVD/EMC Directive)

Instantaneous voltage drop compensator (small capacity) SB series-Part Number-YS20BC96C11A

YS20BC96C11A

Available upon quote

A place free of dust (including conductive), smoke, corrosive gas (including disinfectants), flammable gas, steam, salt, and oil fumes.

150% of rated current (1 minute), 600% (1 cycle)

Approximately 61kg

Delay 0.7~1.0

186V~264V

1.0 seconds

10 seconds interval 100% voltage drop 0.3 seconds 5 times in a row

No interruption

A place where vibrations and shocks are not transmitted

48A

Delay 0.8

9.6kVA

AC input frequency ±1%

Depends on commercial input frequency

50/60Hz±5%

Commercial input voltage ±5%

Depends on utility input voltage

200V

30~90%RH (no condensation)

0℃~+40℃ (annual average below 30℃)

97% or more

Natural cooling

11.5kVA

0℃~+60℃

Indoor

Single phase 2 wire

Single phase 2 wire

JIS, NRTL certified (UL1012), CE marking compliant (LVD/EMC Directive)

Instantaneous voltage drop compensator (small capacity) SB series-Part Number-SB20BC75C01A

SB20BC75C01A

Available upon quote

A place free of dust (including conductive), smoke, corrosive gas (including disinfectants), flammable gas, steam, salt, and oil fumes.

150% of rated current (1 minute), 20 times (1 cycle)

Approximately 40kg

Delay 0.7~1.0

185V~240V

1.0 seconds (at 30% voltage drop) /0.3 seconds (at 100% voltage drop)

10 seconds interval 100% voltage drop 0.3 seconds 5 times in a row

No interruption

A place where vibrations and shocks are not transmitted

22A

Delay 0.8

7.5kVA

AC input frequency ±1%

Depends on commercial input frequency

50/60Hz±5%

Commercial input voltage ±5%

Depends on utility input voltage

200V

30~90%RH (no condensation)

0℃~+40℃ (annual average below 30℃)

98% or more

Natural air cooling

9kVA

-20℃~+60℃

Indoor

Three phase three wire

Three phase three wire

-
Instantaneous voltage drop compensator (small capacity) SB series-Part Number-SB20BC10D01A

SB20BC10D01A

Available upon quote

A place free of dust (including conductive), smoke, corrosive gas (including disinfectants), flammable gas, steam, salt, and oil fumes.

150% of rated current (1 minute), 20 times (1 cycle)

Approximately 70kg

Delay 0.7~1.0

185V~240V

1.0 seconds (at 30% voltage drop) /0.3 seconds (at 100% voltage drop)

10 seconds interval 100% voltage drop 0.3 seconds 5 times in a row

No interruption

A place where vibrations and shocks are not transmitted

29A

Delay 0.8

10kVA

AC input frequency ±1%

Depends on commercial input frequency

50/60Hz±5%

Commercial input voltage ±5%

Depends on utility input voltage

200V

30~90%RH (no condensation)

0℃~+40℃ (annual average below 30℃)

98% or more

Natural air cooling

12kVA

-20℃~+60℃

Indoor

Three phase three wire

Three phase three wire

-
Instantaneous voltage drop compensator (small capacity) SB series-Part Number-SB20BC15D01A

SB20BC15D01A

Available upon quote

A place free of dust (including conductive), smoke, corrosive gas (including disinfectants), flammable gas, steam, salt, and oil fumes.

150% of rated current (1 minute), 20 times (1 cycle)

Approximately 70kg

Delay 0.7~1.0

185V~240V

1.0 seconds (at 30% voltage drop) /0.3 seconds (at 100% voltage drop)

10 seconds interval 100% voltage drop 0.3 seconds 5 times in a row

No interruption

A place where vibrations and shocks are not transmitted

44A

Delay 0.8

15kVA

AC input frequency ±1%

Depends on commercial input frequency

50/60Hz±5%

Commercial input voltage ±5%

Depends on utility input voltage

200V

30~90%RH (no condensation)

0℃~+40℃ (annual average below 30℃)

98% or more

Natural air cooling

18kVA

-20℃~+60℃

Indoor

Three phase three wire

Three phase three wire

-
Instantaneous voltage drop compensator (small capacity) SB series-Part Number-SB20BC20D01A

SB20BC20D01A

Available upon quote

A place free of dust (including conductive), smoke, corrosive gas (including disinfectants), flammable gas, steam, salt, and oil fumes.

150% of rated current (1 minute), 20 times (1 cycle)

Approximately 115kg

Delay 0.7~1.0

185V~240V

1.0 seconds (at 30% voltage drop) /0.3 seconds (at 100% voltage drop)

10 seconds interval 100% voltage drop 0.3 seconds 5 times in a row

No interruption

A place where vibrations and shocks are not transmitted

58A

Delay 0.8

20kVA

AC input frequency ±1%

Depends on commercial input frequency

50/60Hz±5%

Commercial input voltage ±5%

Depends on utility input voltage

200V

30~90%RH (no condensation)

0℃~+40℃ (annual average below 30℃)

98% or more

Natural air cooling

24kVA

-20℃~+60℃

Indoor

Three phase three wire

Three phase three wire

-
Instantaneous voltage drop compensator (small capacity) SB series-Part Number-SB20BC30D01A

SB20BC30D01A

Available upon quote

A place free of dust (including conductive), smoke, corrosive gas (including disinfectants), flammable gas, steam, salt, and oil fumes.

150% of rated current (1 minute), 20 times (1 cycle)

Approximately 120kg

Delay 0.7~1.0

185V~240V

1.0 seconds (at 30% voltage drop) /0.3 seconds (at 100% voltage drop)

10 seconds interval 100% voltage drop 0.3 seconds 5 times in a row

No interruption

A place where vibrations and shocks are not transmitted

87A

Delay 0.8

30kVA

AC input frequency ±1%

Depends on commercial input frequency

50/60Hz±5%

Commercial input voltage ±5%

Depends on utility input voltage

200V

30~90%RH (no condensation)

0℃~+40℃ (annual average below 30℃)

98% or more

Natural air cooling

36kVA

-20℃~+60℃

Indoor

Three phase three wire

Three phase three wire

-
Instantaneous voltage drop compensator (small capacity) SB series-Part Number-SB40BC30D01A

SB40BC30D01A

Available upon quote

A place free of dust (including conductive), smoke, corrosive gas (including disinfectants), flammable gas, steam, salt, and oil fumes.

150% of rated current (1 minute), 20 times (1 cycle)

Approximately 120kg

Delay 0.7~1.0

370V~480V

1.0 seconds (at 30% voltage drop) /0.3 seconds (at 100% voltage drop)

10 seconds interval 100% voltage drop 0.3 seconds 5 times in a row

No interruption

A place where vibrations and shocks are not transmitted

44A

Delay 0.8

30kVA

AC input frequency ±1%

Depends on commercial input frequency

50/60Hz±5%

Commercial input voltage ±5%

Depends on utility input voltage

400V

30~90%RH (no condensation)

0℃~+40℃ (annual average below 30℃)

98% or more

Natural air cooling

36kVA

-20℃~+60℃

Indoor

Three phase three wire

Three phase three wire

-

Click on the part number for more information about each product

Other products of Otowa Electric Industry Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Otowa Electric Industry Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

40.2hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree