Product
Reset breaker RB seriesHandling Company
Otowa Electric Industry Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Current consumption Standby | Current consumption during operation | Lightning resistance (ground to ground) | Mass | Number of poles | Operating temperature range | Operation check | Operation count display | Permanent cut-off condition | Power supply voltage | Rated breaking capacity | Rated current | Rated sensitivity current | Re-input conditions | Reload time |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RB-50EC2-A |
Available upon quote | 50mA or less | 150mA or less | 30kV (1.2/50μs) | Approximately 1.3kg | 2 poles | -10℃~+50℃ | Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. | 0~9 times (9 times or more is displayed as 9 times) |
Manual trip Trip due to overload Trip due to electrical leakage |
-A: 1φ2W AC100V -B: 1φ2W AC200V |
5kA (AC100-200V) | 10, 15, 20, 30, 40, 50A | 30, 100mA | When tripped due to surge | 10 seconds | |
RB-50EC2-B |
Available upon quote | 50mA or less | 150mA or less | 30kV (1.2/50μs) | Approximately 1.3kg | 2 poles | -10℃~+50℃ | Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. | 0~9 times (9 times or more is displayed as 9 times) |
Manual trip Trip due to overload Trip due to electrical leakage |
-A: 1φ2W AC100V -B: 1φ2W AC200V |
5kA (AC100-200V) | 10, 15, 20, 30, 40, 50A | 30, 100mA | When tripped due to surge | 10 seconds | |
RB-50NC2-A |
Available upon quote | 50mA or less | 150mA or less | 30kV (1.2/50μs) | Approximately 1.3kg | 2 poles | -10℃~+50℃ | Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. | 0~9 times (9 times or more is displayed as 9 times) |
Manual trip Trip due to overload |
-A: 1φ2W AC100V -B: 1φ2W AC200V |
5kA (AC100-200V) | 10, 15, 20, 30, 40, 50A | - | When tripped due to surge | 10 seconds | |
RB-50NC2-B |
Available upon quote | 50mA or less | 150mA or less | 30kV (1.2/50μs) | Approximately 1.3kg | 2 poles | -10℃~+50℃ | Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. | 0~9 times (9 times or more is displayed as 9 times) |
Manual trip Trip due to overload |
-A: 1φ2W AC100V -B: 1φ2W AC200V |
5kA (AC100-200V) | 10, 15, 20, 30, 40, 50A | - | When tripped due to surge | 10 seconds | |
RB-50EC-A |
Available upon quote | 50mA or less | 150mA or less | 30kV (1.2/50μs) | Approximately 1.5kg | 3 poles (when using 2 poles, use both ends) | -10℃~+50℃ | Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. | 0~9 times (9 times or more is displayed as 9 times) |
Manual trip Trip due to overload Trip due to electrical leakage |
-A: 1φ2W AC100V -B: 1φ2W AC200V -B: 1φ3W AC100-200V -B: 3φ3W AC200V |
5kA (AC100-200V) | 10, 15, 20, 30, 40, 50A | 30, 100mA | When tripped due to surge | 10 seconds | |
RB-50EC-B |
Available upon quote | 50mA or less | 150mA or less | 30kV (1.2/50μs) | Approximately 1.5kg | 3 poles (when using 2 poles, use both ends) | -10℃~+50℃ | Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. | 0~9 times (9 times or more is displayed as 9 times) |
Manual trip Trip due to overload Trip due to electrical leakage |
-A: 1φ2W AC100V -B: 1φ2W AC200V -B: 1φ3W AC100-200V -B: 3φ3W AC200V |
5kA (AC100-200V) | 10, 15, 20, 30, 40, 50A | 30, 100mA | When tripped due to surge | 10 seconds | |
RB-50NC-A |
Available upon quote | 50mA or less | 150mA or less | 30kV (1.2/50μs) | Approximately 1.5kg | 3 poles (when using 2 poles, use both ends) | -10℃~+50℃ | Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. | 0~9 times (9 times or more is displayed as 9 times) |
Manual trip Trip due to overload |
-A: 1φ2W AC100V -B: 1φ2W AC200V -B: 1φ3W AC100-200V -B: 3φ3W AC200V |
5kA (AC100-200V) | 10, 15, 20, 30, 40, 50A | - | When tripped due to surge | 10 seconds | |
RB-50NC-B |
Available upon quote | 50mA or less | 150mA or less | 30kV (1.2/50μs) | Approximately 1.5kg | 3 poles (when using 2 poles, use both ends) | -10℃~+50℃ | Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. | 0~9 times (9 times or more is displayed as 9 times) |
Manual trip Trip due to overload |
-A: 1φ2W AC100V -B: 1φ2W AC200V -B: 1φ3W AC100-200V -B: 3φ3W AC200V |
5kA (AC100-200V) | 10, 15, 20, 30, 40, 50A | - | When tripped due to surge | 10 seconds | |
RB-50KL1-A |
Available upon quote | 50mA or less | 150mA or less | 30kV (1.2/50μs) | Approximately 2.4kg | 3 poles (when using 2 poles, use both ends) | -10℃~+50℃ | Check the motor rotation mechanism and operation count display using the check button | 0~99 times (100 times or more is displayed as 99 times) |
Manual trip Trip due to overload Trip due to electrical leakage In the case of a breaker with neutral line phase loss protection, tripping due to neutral line phase loss |
-A: 1φ2W AC100V -B: 1φ2W AC200V, 1φ3W AC100-200V, 3φ3W AC200V -N: 1φ3W AC100-200V with neutral line open phase protection |
7.5kA (AC100-200V) | 10, 15, 20, 30, 40, 50, 60A | 30mA, 100-200-500mA | When tripped due to surge | 10 seconds | |
RB-50KL1-B |
Available upon quote | 50mA or less | 150mA or less | 30kV (1.2/50μs) | Approximately 2.4kg | 3 poles (when using 2 poles, use both ends) | -10℃~+50℃ | Check the motor rotation mechanism and operation count display using the check button | 0~99 times (100 times or more is displayed as 99 times) |
Manual trip Trip due to overload Trip due to electrical leakage In the case of a breaker with neutral line phase loss protection, tripping due to neutral line phase loss |
-A: 1φ2W AC100V -B: 1φ2W AC200V, 1φ3W AC100-200V, 3φ3W AC200V -N: 1φ3W AC100-200V with neutral line open phase protection |
7.5kA (AC100-200V) | 10, 15, 20, 30, 40, 50, 60A | 30mA, 100-200-500mA | When tripped due to surge | 10 seconds |
Click on the part number for more information about each product