Reset breaker RB series-RB-50EC2-A
Reset breaker RB series-Otowa Electric Industry Co., Ltd.

Otowa Electric Industry Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

40.2hours


About This Product

■Features

1. Determine whether it is lightning surge or load abnormality The "reset breaker" is an automatic power breaker restart device that will automatically restart the breaker only if it is tripped by a lightning surge (or opening/closing surge), and will not restart if there is a load abnormality such as a ground fault. Reduces the burden on workers. 2.Even if the breaker is tripped by lightning surge just before a power outage, it will automatically turn on again. 3.Record the number of operations The number of automatic reload operations can be managed and becomes valuable data for maintenance. 4. Compatible with various breaker types Earth leakage breaker type, no-fuse breaker type 5.Compact type also available (50A frame only) Space saving can be achieved when incorporating it into the power supply panel. There are other product numbers as well.

  • Product

    Reset breaker RB series

Share this product


370+ people viewing

Last viewed: 12 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Reset breaker RB series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Power supply voltage Mass Lightning resistance (ground to ground) Current consumption Standby Current consumption during operation Permanent cut-off condition Number of poles Rated current Rated breaking capacity Rated sensitivity current Operation count display Operation check Re-input conditions Reload time Operating temperature range
Reset breaker RB series-Part Number-RB-50EC2-A

RB-50EC2-A

Available upon quote

-A: 1φ2W AC100V
-B: 1φ2W AC200V

Approximately 1.3kg

30kV (1.2/50μs)

50mA or less

150mA or less

Manual trip
Trip due to overload
Trip due to electrical leakage

2 poles

10, 15, 20, 30, 40, 50A

5kA (AC100-200V)

30, 100mA

0~9 times (9 times or more is displayed as 9 times)

Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button.

When tripped due to surge

10 seconds

-10℃~+50℃

Reset breaker RB series-Part Number-RB-50EC2-B

RB-50EC2-B

Available upon quote

-A: 1φ2W AC100V
-B: 1φ2W AC200V

Approximately 1.3kg

30kV (1.2/50μs)

50mA or less

150mA or less

Manual trip
Trip due to overload
Trip due to electrical leakage

2 poles

10, 15, 20, 30, 40, 50A

5kA (AC100-200V)

30, 100mA

0~9 times (9 times or more is displayed as 9 times)

Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button.

When tripped due to surge

10 seconds

-10℃~+50℃

Reset breaker RB series-Part Number-RB-50NC2-A

RB-50NC2-A

Available upon quote

-A: 1φ2W AC100V
-B: 1φ2W AC200V

Approximately 1.3kg

30kV (1.2/50μs)

50mA or less

150mA or less

Manual trip
Trip due to overload

2 poles

10, 15, 20, 30, 40, 50A

5kA (AC100-200V)

-

0~9 times (9 times or more is displayed as 9 times)

Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button.

When tripped due to surge

10 seconds

-10℃~+50℃

Reset breaker RB series-Part Number-RB-50NC2-B

RB-50NC2-B

Available upon quote

-A: 1φ2W AC100V
-B: 1φ2W AC200V

Approximately 1.3kg

30kV (1.2/50μs)

50mA or less

150mA or less

Manual trip
Trip due to overload

2 poles

10, 15, 20, 30, 40, 50A

5kA (AC100-200V)

-

0~9 times (9 times or more is displayed as 9 times)

Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button.

When tripped due to surge

10 seconds

-10℃~+50℃

Reset breaker RB series-Part Number-RB-50EC-A

RB-50EC-A

Available upon quote

-A: 1φ2W AC100V
-B: 1φ2W AC200V
-B: 1φ3W AC100-200V
-B: 3φ3W AC200V

Approximately 1.5kg

30kV (1.2/50μs)

50mA or less

150mA or less

Manual trip
Trip due to overload
Trip due to electrical leakage

3 poles (when using 2 poles, use both ends)

10, 15, 20, 30, 40, 50A

5kA (AC100-200V)

30, 100mA

0~9 times (9 times or more is displayed as 9 times)

Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button.

When tripped due to surge

10 seconds

-10℃~+50℃

Reset breaker RB series-Part Number-RB-50EC-B

RB-50EC-B

Available upon quote

-A: 1φ2W AC100V
-B: 1φ2W AC200V
-B: 1φ3W AC100-200V
-B: 3φ3W AC200V

Approximately 1.5kg

30kV (1.2/50μs)

50mA or less

150mA or less

Manual trip
Trip due to overload
Trip due to electrical leakage

3 poles (when using 2 poles, use both ends)

10, 15, 20, 30, 40, 50A

5kA (AC100-200V)

30, 100mA

0~9 times (9 times or more is displayed as 9 times)

Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button.

When tripped due to surge

10 seconds

-10℃~+50℃

Reset breaker RB series-Part Number-RB-50NC-A

RB-50NC-A

Available upon quote

-A: 1φ2W AC100V
-B: 1φ2W AC200V
-B: 1φ3W AC100-200V
-B: 3φ3W AC200V

Approximately 1.5kg

30kV (1.2/50μs)

50mA or less

150mA or less

Manual trip
Trip due to overload

3 poles (when using 2 poles, use both ends)

10, 15, 20, 30, 40, 50A

5kA (AC100-200V)

-

0~9 times (9 times or more is displayed as 9 times)

Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button.

When tripped due to surge

10 seconds

-10℃~+50℃

Reset breaker RB series-Part Number-RB-50NC-B

RB-50NC-B

Available upon quote

-A: 1φ2W AC100V
-B: 1φ2W AC200V
-B: 1φ3W AC100-200V
-B: 3φ3W AC200V

Approximately 1.5kg

30kV (1.2/50μs)

50mA or less

150mA or less

Manual trip
Trip due to overload

3 poles (when using 2 poles, use both ends)

10, 15, 20, 30, 40, 50A

5kA (AC100-200V)

-

0~9 times (9 times or more is displayed as 9 times)

Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button.

When tripped due to surge

10 seconds

-10℃~+50℃

Reset breaker RB series-Part Number-RB-50KL1-A

RB-50KL1-A

Available upon quote

-A: 1φ2W AC100V
-B: 1φ2W AC200V, 1φ3W AC100-200V, 3φ3W AC200V
-N: 1φ3W AC100-200V with neutral line open phase protection

Approximately 2.4kg

30kV (1.2/50μs)

50mA or less

150mA or less

Manual trip
Trip due to overload
Trip due to electrical leakage
In the case of a breaker with neutral line phase loss protection, tripping due to neutral line phase loss

3 poles (when using 2 poles, use both ends)

10, 15, 20, 30, 40, 50, 60A

7.5kA (AC100-200V)

30mA, 100-200-500mA

0~99 times (100 times or more is displayed as 99 times)

Check the motor rotation mechanism and operation count display using the check button

When tripped due to surge

10 seconds

-10℃~+50℃

Reset breaker RB series-Part Number-RB-50KL1-B

RB-50KL1-B

Available upon quote

-A: 1φ2W AC100V
-B: 1φ2W AC200V, 1φ3W AC100-200V, 3φ3W AC200V
-N: 1φ3W AC100-200V with neutral line open phase protection

Approximately 2.4kg

30kV (1.2/50μs)

50mA or less

150mA or less

Manual trip
Trip due to overload
Trip due to electrical leakage
In the case of a breaker with neutral line phase loss protection, tripping due to neutral line phase loss

3 poles (when using 2 poles, use both ends)

10, 15, 20, 30, 40, 50, 60A

7.5kA (AC100-200V)

30mA, 100-200-500mA

0~99 times (100 times or more is displayed as 99 times)

Check the motor rotation mechanism and operation count display using the check button

When tripped due to surge

10 seconds

-10℃~+50℃

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Breakers Products

Other products of Otowa Electric Industry Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Otowa Electric Industry Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

40.2hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree