Reset breaker RB series-RB-50EC2-A
Reset breaker RB series-Otowa Electric Industry Co., Ltd.

About This Product

■Features 1. Determine whether it is lightning surge or load abnormality The "reset breaker" is an automatic power breaker restart device that will automatically restart the breaker only if it is tripped by a lightning surge (or opening/closing surge), and will not restart if there is a load abnormality such as a ground fault. Reduces the burden on workers. 2.Even if the breaker is tripped by lightning surge just before a power outage, it will automatically turn on again. 3.Record the number of operations The number of automatic reload operations can be managed and becomes valuable data for maintenance. 4. Compatible with various breaker types Earth leakage breaker type, no-fuse breaker type 5.Compact type also available (50A frame only) Space saving can be achieved when incorporating it into the power supply panel. There are other product numbers as well.

  • Product

    Reset breaker RB series

Share this product


310+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Reset breaker RB series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Current consumption Standby Current consumption during operation Lightning resistance (ground to ground) Mass Number of poles Operating temperature range Operation check Operation count display Permanent cut-off condition Power supply voltage Rated breaking capacity Rated current Rated sensitivity current Re-input conditions Reload time
Reset breaker RB series-Part Number-RB-50EC2-A

RB-50EC2-A

Available upon quote 50mA or less 150mA or less 30kV (1.2/50μs) Approximately 1.3kg 2 poles -10℃~+50℃ Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. 0~9 times (9 times or more is displayed as 9 times) Manual trip
Trip due to overload
Trip due to electrical leakage
-A: 1φ2W AC100V
-B: 1φ2W AC200V
5kA (AC100-200V) 10, 15, 20, 30, 40, 50A 30, 100mA When tripped due to surge 10 seconds
Reset breaker RB series-Part Number-RB-50EC2-B

RB-50EC2-B

Available upon quote 50mA or less 150mA or less 30kV (1.2/50μs) Approximately 1.3kg 2 poles -10℃~+50℃ Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. 0~9 times (9 times or more is displayed as 9 times) Manual trip
Trip due to overload
Trip due to electrical leakage
-A: 1φ2W AC100V
-B: 1φ2W AC200V
5kA (AC100-200V) 10, 15, 20, 30, 40, 50A 30, 100mA When tripped due to surge 10 seconds
Reset breaker RB series-Part Number-RB-50NC2-A

RB-50NC2-A

Available upon quote 50mA or less 150mA or less 30kV (1.2/50μs) Approximately 1.3kg 2 poles -10℃~+50℃ Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. 0~9 times (9 times or more is displayed as 9 times) Manual trip
Trip due to overload
-A: 1φ2W AC100V
-B: 1φ2W AC200V
5kA (AC100-200V) 10, 15, 20, 30, 40, 50A - When tripped due to surge 10 seconds
Reset breaker RB series-Part Number-RB-50NC2-B

RB-50NC2-B

Available upon quote 50mA or less 150mA or less 30kV (1.2/50μs) Approximately 1.3kg 2 poles -10℃~+50℃ Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. 0~9 times (9 times or more is displayed as 9 times) Manual trip
Trip due to overload
-A: 1φ2W AC100V
-B: 1φ2W AC200V
5kA (AC100-200V) 10, 15, 20, 30, 40, 50A - When tripped due to surge 10 seconds
Reset breaker RB series-Part Number-RB-50EC-A

RB-50EC-A

Available upon quote 50mA or less 150mA or less 30kV (1.2/50μs) Approximately 1.5kg 3 poles (when using 2 poles, use both ends) -10℃~+50℃ Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. 0~9 times (9 times or more is displayed as 9 times) Manual trip
Trip due to overload
Trip due to electrical leakage
-A: 1φ2W AC100V
-B: 1φ2W AC200V
-B: 1φ3W AC100-200V
-B: 3φ3W AC200V
5kA (AC100-200V) 10, 15, 20, 30, 40, 50A 30, 100mA When tripped due to surge 10 seconds
Reset breaker RB series-Part Number-RB-50EC-B

RB-50EC-B

Available upon quote 50mA or less 150mA or less 30kV (1.2/50μs) Approximately 1.5kg 3 poles (when using 2 poles, use both ends) -10℃~+50℃ Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. 0~9 times (9 times or more is displayed as 9 times) Manual trip
Trip due to overload
Trip due to electrical leakage
-A: 1φ2W AC100V
-B: 1φ2W AC200V
-B: 1φ3W AC100-200V
-B: 3φ3W AC200V
5kA (AC100-200V) 10, 15, 20, 30, 40, 50A 30, 100mA When tripped due to surge 10 seconds
Reset breaker RB series-Part Number-RB-50NC-A

RB-50NC-A

Available upon quote 50mA or less 150mA or less 30kV (1.2/50μs) Approximately 1.5kg 3 poles (when using 2 poles, use both ends) -10℃~+50℃ Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. 0~9 times (9 times or more is displayed as 9 times) Manual trip
Trip due to overload
-A: 1φ2W AC100V
-B: 1φ2W AC200V
-B: 1φ3W AC100-200V
-B: 3φ3W AC200V
5kA (AC100-200V) 10, 15, 20, 30, 40, 50A - When tripped due to surge 10 seconds
Reset breaker RB series-Part Number-RB-50NC-B

RB-50NC-B

Available upon quote 50mA or less 150mA or less 30kV (1.2/50μs) Approximately 1.5kg 3 poles (when using 2 poles, use both ends) -10℃~+50℃ Check the motor rotation mechanism, operation rotation display, and control circuit system with the check button. 0~9 times (9 times or more is displayed as 9 times) Manual trip
Trip due to overload
-A: 1φ2W AC100V
-B: 1φ2W AC200V
-B: 1φ3W AC100-200V
-B: 3φ3W AC200V
5kA (AC100-200V) 10, 15, 20, 30, 40, 50A - When tripped due to surge 10 seconds
Reset breaker RB series-Part Number-RB-50KL1-A

RB-50KL1-A

Available upon quote 50mA or less 150mA or less 30kV (1.2/50μs) Approximately 2.4kg 3 poles (when using 2 poles, use both ends) -10℃~+50℃ Check the motor rotation mechanism and operation count display using the check button 0~99 times (100 times or more is displayed as 99 times) Manual trip
Trip due to overload
Trip due to electrical leakage
In the case of a breaker with neutral line phase loss protection, tripping due to neutral line phase loss
-A: 1φ2W AC100V
-B: 1φ2W AC200V, 1φ3W AC100-200V, 3φ3W AC200V
-N: 1φ3W AC100-200V with neutral line open phase protection
7.5kA (AC100-200V) 10, 15, 20, 30, 40, 50, 60A 30mA, 100-200-500mA When tripped due to surge 10 seconds
Reset breaker RB series-Part Number-RB-50KL1-B

RB-50KL1-B

Available upon quote 50mA or less 150mA or less 30kV (1.2/50μs) Approximately 2.4kg 3 poles (when using 2 poles, use both ends) -10℃~+50℃ Check the motor rotation mechanism and operation count display using the check button 0~99 times (100 times or more is displayed as 99 times) Manual trip
Trip due to overload
Trip due to electrical leakage
In the case of a breaker with neutral line phase loss protection, tripping due to neutral line phase loss
-A: 1φ2W AC100V
-B: 1φ2W AC200V, 1φ3W AC100-200V, 3φ3W AC200V
-N: 1φ3W AC100-200V with neutral line open phase protection
7.5kA (AC100-200V) 10, 15, 20, 30, 40, 50, 60A 30mA, 100-200-500mA When tripped due to surge 10 seconds

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Otowa Electric Industry Co., Ltd.


View more products of Otowa Electric Industry Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree