Product
Uninterruptible power supply UPS large capacity HIVERTER-UP201iHandling Company
Kyushu Kiden Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | AC input Number of phases and wires | AC input allowable frequency fluctuation range | AC input allowable voltage fluctuation range | AC input rated frequency | AC input rated voltage | AC output Number of phases and wires | AC output load power factor fluctuation range | AC output rated capacity | AC output rated frequency | AC output rated load power factor | AC output rated voltage | AC output voltage adjustment range | Circuit method Equipped with bypass circuit | Circuit method Main circuit control method | Circuit method Power supply method | Circuit method Storage battery supply method | DC input Number of storage battery cells | DC input allowable voltage fluctuation range | DC input nominal voltage | Output performance External synchronization frequency range | Output performance Frequency accuracy (internal synchronization) | Output performance Instantaneous voltage fluctuation Parallel input/analysis | Output performance Instantaneous voltage fluctuation Power outage/power restoration | Output performance Instantaneous voltage fluctuation Sudden load change 0⇔100% | Output performance Instantaneous voltage fluctuation recovery time | Output performance Output voltage accuracy | Output performance Overcurrent capability Bypass circuit | Output performance Overcurrent capability Inverter | Output performance Voltage waveform distortion factor Linear load | Output performance Voltage waveform distortion rate Nonlinear load |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HIVERTER-UP201i-1.6 |
Available upon quote | Three phase three wire | Within ±5% | Within ±10% | 50Hz/60Hz | 415V | Three phase three wire | 0.7 delay~1.0 | 160kVA | 50Hz/60Hz |
0.9 lag 0.95 delay (optional) |
415V | Within ±5% | Built-in bypass circuit and maintenance bypass circuit | PWM (pulse width modulation control) method | Constant inverter power supply system | Individual storage battery method | 246 cells ~ 272 cells | 393V~607V | 492V~544V | Within ±1.0% | Within ±0.1% | Within ±5.0% | Within ±2.0% | Within ±5.0% | Within 50ms | Within ±1.0% | 1,000% - 1 cycle |
125% - 10 minutes 150% - 1 minute 200% - 0.1 seconds |
Within 2.5% | Within 5.0% | |
HIVERTER-UP201i-4.0 |
Available upon quote | Three phase three wire | Within ±5% | Within ±10% | 50Hz/60Hz | 415V | Three phase three wire | 0.7 delay~1.0 | 400kVA | 50Hz/60Hz |
0.9 lag 0.95 delay (optional) |
415V | Within ±5% | Built-in bypass circuit and maintenance bypass circuit | PWM (pulse width modulation control) method | Constant inverter power supply system | Individual storage battery method | 246 cells ~ 272 cells | 393V~607V | 492V~544V | Within ±1.0% | Within ±0.1% | Within ±5.0% | Within ±2.0% | Within ±5.0% | Within 50ms | Within ±1.0% | 1,000% - 1 cycle |
125% - 10 minutes 150% - 1 minute 200% - 0.1 seconds |
Within 2.5% | Within 5.0% |
Click on the part number for more information about each product