All Categories
History
Product
Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber Excellent series EXHH/EXTH typeHandling Company
Kyushu Kiden Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Electrical characteristics Power supply | Electrical characteristics Maximum load current (A) | Test chamber internal volume (L) (mm) | Product mass (kg) | Product dimensions (mm) | Equipment | Space temperature and humidity deviation (℃/%RH) | Temperature and humidity fluctuation (℃/%RH) | Temperature/humidity gradient (℃/%RH) | Temperature range (℃) | Time to reach extreme temperature | Temperature change rate | Exterior | Classification | Cooling device Refrigerant | Cooling device Cooling method | Cooling water piping diameter (equipment side) | Cooling water amount (when cooling water inlet temperature is 32℃) | Cooling water water pressure (MPa) | Protection device | Controller | Humidity range (%RH) | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
EC-25EXHH |
Available upon quote |
Three phase 200V 50/60Hz |
114 |
235 (width 630 x depth 540 x height 690) |
830 |
Width 1,100 x Depth 1,600 x Height 1,950 |
Sample power supply control terminal, cable hole (Φ50), caster, level adjuster |
2.0/8.0 |
±0.3/±3.0 |
3.0/10.0 |
-70~180 |
Descending: within 10 minutes (20~-70℃) |
Descending: 18.0℃/min (155~-45℃) |
Dark gray finish |
Constant temperature and humidity chamber |
Single stage side: R404A, dual side: (high temperature side) R404A, (low temperature side) R23 |
Water-cooled type, single stage compression refrigeration method + dual refrigeration method |
Rc1 1/4 |
6,000L/h |
0.1~0.5 |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device (constant temperature and humidity chamber only), heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
20~98 |
Shelf support, shelf board, fuse, Y strainer, wick, rubber plug, instruction manual |
|
EC-85EXHH |
Available upon quote |
Three phase 200V 50/60Hz |
160 |
800 (width 1,000 x depth 800 x height 1,000) |
1,275 |
Width 1,470 x depth 2,235 x height 2,065 |
Sample power supply control terminal, cable hole (Φ50), caster, level adjuster |
3.0/8.0 |
±0.3/±3.0 |
4.0/10.0 |
-70~180 |
Descending: within 20 minutes (20~-70℃) |
Descending: 15.0℃/min (155~-45℃) |
Dark gray finish |
Constant temperature and humidity chamber |
Single stage side: R404A, dual side: (high temperature side) R404A, (low temperature side) R23 |
Water-cooled type, single stage compression refrigeration method + dual refrigeration method |
Rc1 1/4 |
7,200L/h |
0.1~0.5 |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device (constant temperature and humidity chamber only), heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
20~95 |
Shelf support, shelf board, fuse, Y strainer, wick, rubber plug, instruction manual |
|
EC-85EXHH20 |
Available upon quote |
Three phase 200V 50/60Hz |
225 |
800 (width 1,000 x depth 800 x height 1,000) |
1,420 |
Width 1,470 x depth 2,235 x height 2,065 |
Sample power supply control terminal, cable hole (Φ50), caster, level adjuster |
3.0/8.0 |
±0.3/±3.0 |
4.0/10.0 |
-70~180 |
Descending: within 20 minutes (20~-70℃) |
Descending: 20.0℃/min (155~-45℃) |
Dark gray finish |
Constant temperature and humidity chamber |
Single stage side: R404A, dual side: (high temperature side) R404A, (low temperature side) R23 |
Water-cooled type, single stage compression refrigeration method + dual refrigeration method |
Rc2 |
10,800L/h |
0.1~0.5 |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device (constant temperature and humidity chamber only), heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
20~95 |
Shelf support, shelf board, fuse, Y strainer, wick, rubber plug, instruction manual |
|
EC-25EXTH |
Available upon quote |
Three phase 200V 50/60Hz |
105 |
235 (width 630 x depth 540 x height 690) |
825 |
Width 1,100 x Depth 1,600 x Height 1,950 |
Sample power supply control terminal, cable hole (Φ50), caster, level adjuster |
2.0 |
±0.3 |
3.0 |
-70~180 |
Descending: within 10 minutes (20~-70℃) |
Descending: 18.0℃/min (155~-45℃) |
Dark gray finish |
Constant temperature bath |
Single stage side: R404A, dual side: (high temperature side) R404A, (low temperature side) R23 |
Water-cooled type, single stage compression refrigeration method + dual refrigeration method |
Rc1 1/4 |
6,000L/h |
0.1~0.5 |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device (constant temperature and humidity chamber only), heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
- |
Shelf support, shelf board, fuse, Y strainer, rubber plug, instruction manual |
|
EC-85EXTH |
Available upon quote |
Three phase 200V 50/60Hz |
150 |
800 (width 1,000 x depth 800 x height 1,000) |
1,225 |
Width 1,470 x depth 2,235 x height 2,065 |
Sample power supply control terminal, cable hole (Φ50), caster, level adjuster |
3.0 |
±0.3 |
4.0 |
-70~180 |
Descending: within 20 minutes (20~-70℃) |
Descending: 15.0℃/min (155~-45℃) |
Dark gray finish |
Constant temperature bath |
Single stage side: R404A, dual side: (high temperature side) R404A, (low temperature side) R23 |
Water-cooled type, single stage compression refrigeration method + dual refrigeration method |
Rc1 1/4 |
7,200L/h |
0.1~0.5 |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device (constant temperature and humidity chamber only), heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
- |
Shelf support, shelf board, fuse, Y strainer, rubber plug, instruction manual |
|
EC-85EXTH20 |
Available upon quote |
Three phase 200V 50/60Hz |
215 |
800 (width 1,000 x depth 800 x height 1,000) |
1,410 |
Width 1,470 x depth 2,235 x height 2,065 |
Sample power supply control terminal, cable hole (Φ50), caster, level adjuster |
3.0 |
±0.3 |
4.0 |
-70~180 |
Descending: within 20 minutes (20~-70℃) |
Descending: 20.0℃/min (155~-45℃) |
Dark gray finish |
Constant temperature bath |
Single stage side: R404A, dual side: (high temperature side) R404A, (low temperature side) R23 |
Water-cooled type, single stage compression refrigeration method + dual refrigeration method |
Rc2 |
10,800L/h |
0.1~0.5 |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device (constant temperature and humidity chamber only), heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
- |
Shelf support, shelf board, fuse, Y strainer, rubber plug, instruction manual |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
38.0hrs
Company Review
5.0