All Categories
History
Product
Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber High performance series LinexusHandling Company
Kyushu Kiden Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Electrical characteristics Power supply | Electrical characteristics Maximum load current (A) | Test chamber internal volume (L) (mm) | Product mass (kg) | Product dimensions (mm) | Equipment | Space temperature and humidity deviation (℃/%RH) | Temperature and humidity fluctuation (℃/%RH) | Temperature/humidity gradient (℃/%RH) | Temperature range (℃) | Time to reach extreme temperature | Temperature change rate | Exterior | Compressor method | Compressor output | Classification | Protection device | Controller | Humidity range (%RH) | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
EC-46MHPE |
Available upon quote |
Three phase 200V 50/60Hz |
Twenty three |
408 (width 630 x depth 720 x height 900) |
315 |
Width 1,030 x Depth 1,090 x Height 1,695 |
Observation window, cable hole, tank light, casters, level adjuster, USB port |
1.5/5 |
±0.3/±2.5 |
3.0/10 |
-40~100 |
Descending: within 40 minutes (20~-40℃) |
Descending: 3.0℃/min (86~-26℃) |
Stainless steel plate (SUS430, hairline finish) |
Scroll + scroll |
0.6kW (inverter control) +1.1kW |
Constant temperature and humidity chamber |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
20~98 |
Instruction manual, soft silicone plug for cable hole, wick |
|
EC-46MHHPE |
Available upon quote |
Three phase 200V 50/60Hz |
Twenty three |
408 (width 630 x depth 720 x height 900) |
315 |
Width 1,030 x Depth 1,090 x Height 1,695 |
Observation window, cable hole, tank light, casters, level adjuster, USB port |
1.5/5 |
±0.3/±2.5 |
3.0/10 |
-40~150 |
Descending: within 40 minutes (20~-40℃) |
Descending: 3.0℃/min (131~-21℃) |
Stainless steel plate (SUS430, hairline finish) |
Scroll + scroll |
0.6kW (inverter control) +1.1kW |
Constant temperature and humidity chamber |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
20~98 |
Instruction manual, soft silicone plug for cable hole, wick |
|
EC-86MHPE |
Available upon quote |
Three phase 200V 50/60Hz |
39 |
800 (width 1,000 x depth 800 x height 1,000) |
520 |
Width 1,400 x Depth 1,170 x Height 1,795 |
Observation window, cable hole, tank light, casters, level adjuster, USB port |
1.5/5 |
±0.3/±2.5 |
3.0/10 |
-40~100 |
Descending: within 40 minutes (20~-40℃) |
Descending: 3.0℃/min (86~-26℃) |
Stainless steel plate (SUS430, hairline finish) |
Scroll + scroll |
0.6kW (inverter control) +1.5kW |
Constant temperature and humidity chamber |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
20~98 |
Instruction manual, soft silicone plug for cable hole, wick |
|
EC-86MHHPE |
Available upon quote |
Three phase 200V 50/60Hz |
39 |
800 (width 1,000 x depth 800 x height 1,000) |
520 |
Width 1,400 x Depth 1,170 x Height 1,795 |
Observation window, cable hole, tank light, casters, level adjuster, USB port |
1.5/5 |
±0.3/±2.5 |
3.0/10 |
-40~150 |
Descending: within 40 minutes (20~-40℃) |
Descending: 3.0℃/min (131~-21℃) |
Stainless steel plate (SUS430, hairline finish) |
Scroll + scroll |
0.6kW (inverter control) +1.5kW |
Constant temperature and humidity chamber |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
20~98 |
Instruction manual, soft silicone plug for cable hole, wick |
|
EC-46MTPE |
Available upon quote |
Three phase 200V 50/60Hz |
18 |
408 (width 630 x depth 720 x height 900) |
310 |
Width 1,030 x Depth 1,090 x Height 1,695 |
Observation window, cable hole, tank light, casters, level adjuster, USB port |
1.5 |
±0.3 |
3 |
-40~100 |
Descending: within 40 minutes (20~-40℃) |
Descending: 3.0℃/min (86~-26℃) |
Stainless steel plate (SUS430, hairline finish) |
Scroll + scroll |
0.6kW (inverter control) +1.1kW |
Constant temperature bath |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
- |
Instruction manual/Soft silicone plug for cable hole |
|
EC-46MTHPE |
Available upon quote |
Three phase 200V 50/60Hz |
18 |
408 (width 630 x depth 720 x height 900) |
310 |
Width 1,030 x Depth 1,090 x Height 1,695 |
Observation window, cable hole, tank light, casters, level adjuster, USB port |
1.5 |
±0.3 |
3.0 |
-40~150 |
Descending: within 40 minutes (20~-40℃) |
Descending: 3.0℃/min (131~-21℃) |
Stainless steel plate (SUS430, hairline finish) |
Scroll + scroll |
0.6kW (inverter control) +1.1kW |
Constant temperature bath |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
- |
Instruction manual/Soft silicone plug for cable hole |
|
EC-86MTPE |
Available upon quote |
Three phase 200V 50/60Hz |
29 |
800 (width 1,000 x depth 800 x height 1,000) |
515 |
Width 1,400 x Depth 1,170 x Height 1,795 |
Observation window, cable hole, tank light, casters, level adjuster, USB port |
1.5 |
±0.3 |
3 |
-40~100 |
Descending: within 40 minutes (20~-40℃) |
Descending: 3.0℃/min (86~-26℃) |
Stainless steel plate (SUS430, hairline finish) |
Scroll + scroll |
0.6kW (inverter control) +1.5kW |
Constant temperature bath |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
- |
Instruction manual/Soft silicone plug for cable hole |
|
EC-86MTHPE |
Available upon quote |
Three phase 200V 50/60Hz |
29 |
800 (width 1,000 x depth 800 x height 1,000) |
515 |
Width 1,400 x Depth 1,170 x Height 1,795 |
Observation window, cable hole, tank light, casters, level adjuster, USB port |
1.5 |
±0.3 |
3.0 |
-40~150 |
Descending: within 40 minutes (20~-40℃) |
Descending: 3.0℃/min (131~-21℃) |
Stainless steel plate (SUS430, hairline finish) |
Scroll + scroll |
0.6kW (inverter control) +1.5kW |
Constant temperature bath |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
- |
Instruction manual/Soft silicone plug for cable hole |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
38.0hrs
Company Review
5.0