Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard series-EC-16MHP
Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard series-Kyushu Kiden Co., Ltd.

Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard series
Kyushu Kiden Co., Ltd.


About This Product

■Summary Hitachi's environmental testing equipment "Cosmopia" meets the demands of the times with functionality and reliability. Environmental test equipment is used in many fields such as semiconductors, electronic components, and biotechnology, and is required to be highly functional for more advanced development and research. At the heart of Hitachi's system is a scroll compressor that provides efficient and stable performance in the low frequency range. We create a testing environment that is essential for improving the reliability of various products and for experiments and research in the food, chemical, and pharmaceutical fields. ■Features Constant temperature and humidity chamber/constant temperature chamber standard series. Stainless steel is used for the exterior material. ■Renovated exterior design The design has been redesigned by using stainless steel (SUS430) for the exterior material and installing a clear cover in the center of the device. ■All models are equipped with a scroll compressor All models use Hitachi's proven scroll compressor. ■New features added ・Defrost function ・Humidification delay function ・USB memory storage function ・Data log function ・Operation mode selection function (selection for each step of the program) ■Digital overheat prevention device A digital overheat protector has been adopted in place of the conventional dial type overheat protector to improve setting operations and temperature accuracy. ■3-year warranty on refrigeration cycle components Refrigeration cycle components come with a 3-year free warranty so you can use them with peace of mind. ■Defrost function - When the temperature inside the tank is less than 5℃, the heater heats the tank to raise it to the specified temperature and defrost it. ・When the temperature inside the tank is 5℃ or higher, the refrigerator will be stopped and defrosted. ■Humidification delay function (temperature and humidity chamber) In order to prevent condensation on the sample, when the temperature and humidity rise, this function waits for a preset time (1 to 120 minutes) after the dry bulb temperature reaches a predetermined temperature before starting humidification. There are other model numbers as well.

  • Product

    Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard series

Share this product


360+ people viewing

Last viewed: 10 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Accessories Controller Electrical characteristics Maximum load current (A) Electrical characteristics Power supply Equipment Exterior Product dimensions Depth (mm) Product dimensions Height (mm) Product dimensions Width (mm) Product mass (kg) Protection device Refrigerant Space temperature and humidity deviation (℃/%RH) Temperature and humidity fluctuation (℃/%RH) Temperature change rate Temperature range/humidity range (℃/%RH) Temperature/humidity gradient (℃/%RH) Test chamber dimensions Height (mm) Test chamber dimensions Width (mm) Test chamber dimensions depth (mm) Test chamber internal volume (L) Time to reach extreme temperature
Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard series-Part Number-EC-16MHP

EC-16MHP

Available upon quote Instruction manual, soft silicone plug for cable hole, wick Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) 18 Three phase 200V 50/60Hz Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. Stainless steel plate (SUS430, hairline finish) 770 1,425 900 170 Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. R404A 1.5/5 ±0.3/±2.5 Descending: 2.0℃/min (86~-26℃)
Rise: 3.0℃/min (-26~86℃)
-40~100/20~98 3.0/10 630 500 380 120 Descending: within 60 minutes (20~-40℃)
Rise: within 30 minutes (20~100℃)
Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard series-Part Number-EC-26MHP

EC-26MHP

Available upon quote Instruction manual, soft silicone plug for cable hole, wick Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) 19 Three phase 200V 50/60Hz Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. Stainless steel plate (SUS430, hairline finish) 770 1,695 1,030 210 Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. R404A 1.5/5 ±0.3/±2.5 Descending: 2.0℃/min (86~-26℃)
Rise: 3.0℃/min (-26~86℃)
-40~100/20~98 3.0/10 900 630 400 227 Descending: within 60 minutes (20~-40℃)
Rise: within 30 minutes (20~100℃)
Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard series-Part Number-EC-46MHP

EC-46MHP

Available upon quote Instruction manual, soft silicone plug for cable hole, wick Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) Twenty two Three phase 200V 50/60Hz Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. Stainless steel plate (SUS430, hairline finish) 1,090 1,695 1,030 300 Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. R404A 1.5/5 ±0.3/±2.5 Descending: 2.0℃/min (86~-26℃)
Rise: 3.0℃/min (-26~86℃)
-40~100/20~98 3.0/10 900 630 720 408 Descending: within 40 minutes (20~-40℃)
Rise: within 30 minutes (20~100℃)
Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard series-Part Number-EC-86MHP

EC-86MHP

Available upon quote Instruction manual, soft silicone plug for cable hole, wick Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) 35 Three phase 200V 50/60Hz Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. Stainless steel plate (SUS430, hairline finish) 1,170 1,795 1,400 480 Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. R404A 1.5/5 ±0.3/±2.5 Descending: 2.0℃/min (86~-26℃)
Rise: 3.0℃/min (-26~86℃)
-40~100/20~98 3.0/10 1,000 1,000 800 800 Descending: within 60 minutes (20~-40℃)
Rise: within 30 minutes (20~100℃)
Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard series-Part Number-EC-106MHP

EC-106MHP

Available upon quote Instruction manual, soft silicone plug for cable hole, wick Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) 35 Three phase 200V 50/60Hz Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. Stainless steel plate (SUS430, hairline finish) 1,370 1,795 1,400 550 Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. R404A 2.0/5 ±0.3/±2.5 Descending: 1.5℃/min (86~-26℃)
Rise: 3.0℃/min (-26~86℃)
-40~100/20~98 4.0/10 1,000 1,000 1,000 1,000 Descending: within 90 minutes (20~-40℃)
Rising: within 40 minutes (20~100℃)
Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard series-Part Number-EC-16MHHP

EC-16MHHP

Available upon quote Instruction manual, soft silicone plug for cable hole, wick Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) 18 Three phase 200V 50/60Hz Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. Stainless steel plate (SUS430, hairline finish) 770 1,425 900 170 Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. R404A 1.5/5 ±0.3/±2.5 Decrease: 2.0℃/min (131~-21℃)
Rise: 3.0℃/min (-21~131℃)
-40~150/20~98 3.0/10 630 500 380 120 Descending: within 60 minutes (20~-40℃)
Rising: within 50 minutes (20~150℃)
Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard series-Part Number-EC-26MHHP

EC-26MHHP

Available upon quote Instruction manual, soft silicone plug for cable hole, wick Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) 19 Three phase 200V 50/60Hz Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. Stainless steel plate (SUS430, hairline finish) 770 1,695 1,030 210 Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. R404A 1.5/5 ±0.3/±2.5 Decrease: 2.0℃/min (131~-21℃)
Rise: 3.0℃/min (-21~131℃)
-40~150/20~98 3.0/10 900 630 400 227 Descending: within 60 minutes (20~-40℃)
Rising: within 50 minutes (20~150℃)
Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard series-Part Number-EC-46MHHP

EC-46MHHP

Available upon quote Instruction manual, soft silicone plug for cable hole, wick Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) Twenty two Three phase 200V 50/60Hz Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. Stainless steel plate (SUS430, hairline finish) 1,090 1,695 1,030 300 Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. R404A 1.5/5 ±0.3/±2.5 Decrease: 2.0℃/min (131~-21℃)
Rise: 3.0℃/min (-21~131℃)
-40~150/20~98 3.0/10 900 630 720 408 Descending: within 50 minutes (20~-40℃)
Rising: within 50 minutes (20~150℃)
Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard series-Part Number-EC-86MHHP

EC-86MHHP

Available upon quote Instruction manual, soft silicone plug for cable hole, wick Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) 35 Three phase 200V 50/60Hz Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. Stainless steel plate (SUS430, hairline finish) 1,170 1,795 1,400 480 Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. R404A 1.5/5 ±0.3/±2.5 Decrease: 2.0℃/min (131~-21℃)
Rise: 3.0℃/min (-21~131℃)
-40~150/20~98 3.0/10 1,000 1,000 800 800 Descending: within 70 minutes (20~-40℃)
Rising: within 50 minutes (20~150℃)
Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard series-Part Number-EC-106MHHP

EC-106MHHP

Available upon quote Instruction manual, soft silicone plug for cable hole, wick Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) 35 Three phase 200V 50/60Hz Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. Stainless steel plate (SUS430, hairline finish) 1,370 1,795 1,400 550 Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. R404A 2.0/10 ±0.3/±2.5 Decrease: 1.5℃/min (131~-21℃)
Rise: 3.0℃/min (-21~131℃)
-40~150/20~98 4.0/10 1,000 1,000 1,000 1,000 Descending: within 90 minutes (20~-40℃)
Rise: within 65 minutes (20~150℃)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Kyushu Kiden Co., Ltd.


View more products of Kyushu Kiden Co., Ltd.