Environmental test equipment (Cosmopia C) Constant temperature and humidity chamber standard seriesHandling Company
Kyushu Kiden Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Electrical characteristics Power supply | Electrical characteristics Maximum load current (A) | Test chamber dimensions Height (mm) | Test chamber dimensions Width (mm) | Test chamber dimensions depth (mm) | Test chamber internal volume (L) | Product mass (kg) | Product dimensions Height (mm) | Product dimensions Width (mm) | Product dimensions Depth (mm) | Equipment | Space temperature and humidity deviation (℃/%RH) | Temperature and humidity fluctuation (℃/%RH) | Temperature/humidity gradient (℃/%RH) | Temperature range/humidity range (℃/%RH) | Time to reach extreme temperature | Temperature change rate | Exterior | Refrigerant | Protection device | Controller | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
EC-16MHP |
Available upon quote |
Three phase 200V 50/60Hz |
18 |
630 |
500 |
380 |
120 |
170 |
1,425 |
900 |
770 |
Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. |
1.5/5 |
±0.3/±2.5 |
3.0/10 |
-40~100/20~98 |
Descending: within 60 minutes (20~-40℃) |
Descending: 2.0℃/min (86~-26℃) |
Stainless steel plate (SUS430, hairline finish) |
R404A |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
Instruction manual, soft silicone plug for cable hole, wick |
|
EC-26MHP |
Available upon quote |
Three phase 200V 50/60Hz |
19 |
900 |
630 |
400 |
227 |
210 |
1,695 |
1,030 |
770 |
Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. |
1.5/5 |
±0.3/±2.5 |
3.0/10 |
-40~100/20~98 |
Descending: within 60 minutes (20~-40℃) |
Descending: 2.0℃/min (86~-26℃) |
Stainless steel plate (SUS430, hairline finish) |
R404A |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
Instruction manual, soft silicone plug for cable hole, wick |
|
EC-46MHP |
Available upon quote |
Three phase 200V 50/60Hz |
Twenty two |
900 |
630 |
720 |
408 |
300 |
1,695 |
1,030 |
1,090 |
Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. |
1.5/5 |
±0.3/±2.5 |
3.0/10 |
-40~100/20~98 |
Descending: within 40 minutes (20~-40℃) |
Descending: 2.0℃/min (86~-26℃) |
Stainless steel plate (SUS430, hairline finish) |
R404A |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
Instruction manual, soft silicone plug for cable hole, wick |
|
EC-86MHP |
Available upon quote |
Three phase 200V 50/60Hz |
35 |
1,000 |
1,000 |
800 |
800 |
480 |
1,795 |
1,400 |
1,170 |
Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. |
1.5/5 |
±0.3/±2.5 |
3.0/10 |
-40~100/20~98 |
Descending: within 60 minutes (20~-40℃) |
Descending: 2.0℃/min (86~-26℃) |
Stainless steel plate (SUS430, hairline finish) |
R404A |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
Instruction manual, soft silicone plug for cable hole, wick |
|
EC-106MHP |
Available upon quote |
Three phase 200V 50/60Hz |
35 |
1,000 |
1,000 |
1,000 |
1,000 |
550 |
1,795 |
1,400 |
1,370 |
Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. |
2.0/5 |
±0.3/±2.5 |
4.0/10 |
-40~100/20~98 |
Descending: within 90 minutes (20~-40℃) |
Descending: 1.5℃/min (86~-26℃) |
Stainless steel plate (SUS430, hairline finish) |
R404A |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
Instruction manual, soft silicone plug for cable hole, wick |
|
EC-16MHHP |
Available upon quote |
Three phase 200V 50/60Hz |
18 |
630 |
500 |
380 |
120 |
170 |
1,425 |
900 |
770 |
Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. |
1.5/5 |
±0.3/±2.5 |
3.0/10 |
-40~150/20~98 |
Descending: within 60 minutes (20~-40℃) |
Decrease: 2.0℃/min (131~-21℃) |
Stainless steel plate (SUS430, hairline finish) |
R404A |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
Instruction manual, soft silicone plug for cable hole, wick |
|
EC-26MHHP |
Available upon quote |
Three phase 200V 50/60Hz |
19 |
900 |
630 |
400 |
227 |
210 |
1,695 |
1,030 |
770 |
Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. |
1.5/5 |
±0.3/±2.5 |
3.0/10 |
-40~150/20~98 |
Descending: within 60 minutes (20~-40℃) |
Decrease: 2.0℃/min (131~-21℃) |
Stainless steel plate (SUS430, hairline finish) |
R404A |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
Instruction manual, soft silicone plug for cable hole, wick |
|
EC-46MHHP |
Available upon quote |
Three phase 200V 50/60Hz |
Twenty two |
900 |
630 |
720 |
408 |
300 |
1,695 |
1,030 |
1,090 |
Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. |
1.5/5 |
±0.3/±2.5 |
3.0/10 |
-40~150/20~98 |
Descending: within 50 minutes (20~-40℃) |
Decrease: 2.0℃/min (131~-21℃) |
Stainless steel plate (SUS430, hairline finish) |
R404A |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
Instruction manual, soft silicone plug for cable hole, wick |
|
EC-86MHHP |
Available upon quote |
Three phase 200V 50/60Hz |
35 |
1,000 |
1,000 |
800 |
800 |
480 |
1,795 |
1,400 |
1,170 |
Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. |
1.5/5 |
±0.3/±2.5 |
3.0/10 |
-40~150/20~98 |
Descending: within 70 minutes (20~-40℃) |
Decrease: 2.0℃/min (131~-21℃) |
Stainless steel plate (SUS430, hairline finish) |
R404A |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
Instruction manual, soft silicone plug for cable hole, wick |
|
EC-106MHHP |
Available upon quote |
Three phase 200V 50/60Hz |
35 |
1,000 |
1,000 |
1,000 |
1,000 |
550 |
1,795 |
1,400 |
1,370 |
Observation window, cable hole, tank light, casters, level adjuster, USB port, RS-232C interface, etc. |
2.0/10 |
±0.3/±2.5 |
4.0/10 |
-40~150/20~98 |
Descending: within 90 minutes (20~-40℃) |
Decrease: 1.5℃/min (131~-21℃) |
Stainless steel plate (SUS430, hairline finish) |
R404A |
Earth leakage circuit breaker, control circuit fuse, motor overload protection device, high voltage cutoff device, overtemperature rise prevention device, dry firing prevention device, heater overcurrent protection device, etc. |
Operation mode: Fixed value or program operation (Number of steps: 20 steps/1 pattern, number of repetitions: max. 98 times and infinite) |
Instruction manual, soft silicone plug for cable hole, wick |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
38.0hrs
Company Review
5.0