■Summary

Equipped with an inverter compressor to improve water temperature accuracy. Achieves high energy savings by improving performance during low-load operation. Furthermore, module control functions are standard equipment.

■Equipped with an inverter compressor to improve water temperature accuracy

The operating capacity of the compressor is controlled by an inverter according to the load, improving the accuracy of the cold water outlet water temperature and supplying it to the load.

■Can control up to 8 modules in 1 group (maximum cooling capacity 480kW)

Equipped with module control function as standard. A dedicated controller for controlling the number of units is not required. (It is necessary to input operation commands from the ``system operation button'' (optional part of the ``handheld system operation kit'') or remotely.

■Number of units control function

Operate the number of machines commensurate with the load. (It is also possible to turn on/off the thermostat on all units at the same time without controlling the number of units.

■Rotation function

We monitor the operating time of each module and implement operating rotations for each module so that the operating time is evened out. It is also possible to prioritize each machine.

■Operation at abnormal stop

You can avoid the risk of complete stoppage. The module that has stopped abnormally is disconnected from unit control and operation continues with other normal modules. Even if Unit 1 (master unit) stops due to an abnormality, Unit 1 itself will be disconnected and operation will continue.

■Setting the number of starting units/limiting the number of operating units

You can set the number of devices to start up when the system starts up, regardless of the load status. It is also possible to limit the minimum and maximum number of units in operation, allowing you to select an operation method that suits your load and power situation.

■You can operate and stop the system at your fingertips.

A handy system start/stop button and wiring kit. Please install it on-site using the knockout hole.

■Built-in active filter (AF) for harmonic countermeasures available (can be modified) (excluding 90 and 150 models)

To deal with harmonics, we have prepared a built-in active filter (AF) that can be installed inside the chiller unit. (It will be shipped built into the main body.)

■Can be transported by elevator

It can be transported using an 11-seater elevator.

■Expanded capacity control range

By installing an inverter compressor, the lower limit of the capacity control range has been expanded. It is possible to supply cold water at a more stable outlet water temperature even during low loads.

  • Product

    Chiller unit water-cooled type (standard/inverter)

Share this product


740+ people viewing

Last viewed: 18 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

6 Models of Chiller unit water-cooled type (standard/inverter)

Click on the part number for more information about each product

Image Part Number Price (excluding tax) High Pressure Gas Safety Act classification Power supply Power supply (on-site connection) Electrical characteristics Operating current (A) Electrical characteristics Power consumption (kW) Electrical characteristics Starting current (maximum ending) (A) Electrical characteristics Reference current (A) Electrical characteristics Power factor (%) Operation adjustment device Operation switch Operation adjustment device indicator light Operation adjustment device Water temperature adjustment device Operation adjustment device capacity control range (%) Operation adjustment device Refrigerant pressure gauge Lubricating oil type Legal refrigeration capacity (tons) Water cooler model Exterior (Munsell symbol) Dimensions Height (mm) Dimensions Width (mm) Dimensions Depth (mm) Compressor Motor rated output (number of poles) (kW) Compressor Lubricating oil temperature adjustment device Compressor model Number of compressors (units) Condenser model Refrigerant control device Refrigerant type Refrigerant amount (kg) Cooling capacity (kW) Cooling COP Protective device (protective control function)
Chiller unit water-cooled type (standard/inverter)-Part Number-RCUNP90WV1

RCUNP90WV1

Available upon quote

No notification required

Three phase 200V 50/60Hz

7.6

2.36

15

12.4

90

With operation switch, remote - with local switch (remote control contacts prepared on site/controller/remote control are optional parts)

Red: Driving
Orange: Alarm

Electronic temperature controller (outlet water temperature control)

100~31・Stop

Not included (with connection port and segment display function)

FVC68D

1.1

Plate type

Natural gray (1.0Y 8.5/0.5)

1,380

820

500

2.2 (6) ×1 cycle

Oil heater (52W)

Scroll

1

Double pipe type

Electronic expansion valve

R410A

1.1

9

3.81

High pressure pressure cutoff device, low pressure pressure cutoff control, antifreeze control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse

Chiller unit water-cooled type (standard/inverter)-Part Number-RCUNP150WV1

RCUNP150WV1

Available upon quote

No notification required

Three phase 200V 50/60Hz

13.1

4.08

15

21.3

90

With operation switch, remote - with local switch (remote control contacts prepared on site/controller/remote control are optional parts)

Red: Driving
Orange: Alarm

Electronic temperature controller (outlet water temperature control)

100~21・Stop

Not included (with connection port and segment display function)

FVC68D

1.62

Plate type

Natural gray (1.0Y 8.5/0.5)

1,380

820

500

3.8 (6) ×1 cycle

Oil heater (52W)

Scroll

1

Double pipe type

Electronic expansion valve

R410A

1.7

15

3.67

High pressure pressure cutoff device, low pressure pressure cutoff control, antifreeze control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse

Chiller unit water-cooled type (standard/inverter)-Part Number-RCUNP224WV1

RCUNP224WV1

Available upon quote

No notification required

Three phase 200V 50/60Hz

19.6

6.1

15

31.9

90

With operation switch, remote - with local switch (remote control contacts prepared on site/controller/remote control are optional parts)

Red: Driving
Orange: Alarm

Electronic temperature controller (outlet water temperature control)

100~32・Stop

Not included (with connection port and segment display function)

FVC68D

2.55

Plate type

Natural gray (1.0Y 8.5/0.5)

1,380

950

500

5.6 (6) ×1 cycle

Oil heater (40.8W×2)

Scroll

1

Double pipe type

Electronic expansion valve

R410A

2.2

22.4

3.67

High pressure pressure cutoff device, low pressure pressure cutoff control, antifreeze control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse

Chiller unit water-cooled type (standard/inverter)-Part Number-RCUNP300WV1

RCUNP300WV1

Available upon quote

No notification required

Three phase 200V 50/60Hz

25.3

7.9

15

41.2

90

With operation switch, remote - with local switch (remote control contacts prepared on site/controller/remote control are optional parts)

Red: Driving
Orange: Alarm

Electronic temperature controller (outlet water temperature control)

100~29・Stop

Not included (with connection port and segment display function)

FVC68D

3.49

Plate type

Natural gray (1.0Y 8.5/0.5)

1,380

950

500

7.3 (6) ×1 cycle

Oil heater (40.8W×2)

Scroll

1

Double pipe type

Electronic expansion valve

R410A

2.7

30

3.79

High pressure pressure cutoff device, low pressure pressure cutoff control, antifreeze control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse

Chiller unit water-cooled type (standard/inverter)-Part Number-RCUNP450WV1

RCUNP450WV1

Available upon quote

No notification required

Three phase 200V 50/60Hz

39.1

12.2

34.6

56

90

With operation switch, remote - with local switch (remote control contacts prepared on site/controller/remote control are optional parts)

Red: Driving
Orange: Alarm

Electronic temperature controller (outlet water temperature control)

100~15・Stop

Not included (with connection port and segment display function)

FVC68D

5.44

Plate type

Natural gray (1.0Y 8.5/0.5)

1,380

1,210

640

(5.6+5.6 (6) ) ×1 cycle

Oil heater (40.8W×4)

Scroll

2

Double pipe type

Electronic expansion valve

R410A

4.2

45

3.68

High pressure pressure cutoff device, low pressure pressure cutoff control, antifreeze control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse

Chiller unit water-cooled type (standard/inverter)-Part Number-RCUNP600WV1

RCUNP600WV1

Available upon quote

No notification required

Three phase 200V 50/60Hz

50.7

15.8

40.4

72.6

90

With operation switch, remote - with local switch (remote control contacts prepared on site/controller/remote control are optional parts)

Red: Driving
Orange: Alarm

Electronic temperature controller (outlet water temperature control)

100~14・Stop

Not included (with connection port and segment display function)

FVC68D

6.98

Plate type

Natural gray (1.0Y 8.5/0.5)

1,380

1,210

640

(7.3+7.3 (6) ) ×1 cycle

Oil heater (40.8W×4)

Scroll

2

Double pipe type

Electronic expansion valve

R410A

5.3

60

3.79

High pressure pressure cutoff device, low pressure pressure cutoff control, antifreeze control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Chiller Units Products

Other products of Kyushu Kiden Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Kyushu Kiden Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

38.9hrs


Company Review

5.0
  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree