All Categories
History
Product
Chiller unit Air-cooled cooling only (standard/inverter)Handling Company
Kyushu Kiden Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | High Pressure Gas Safety Act classification | Electrical characteristics Power consumption (kW) | Operation adjustment device Operation switch | Operation adjustment device indicator light | Operation adjustment device Water temperature adjustment device | Operation adjustment device capacity control range (%) | Operation adjustment device Refrigerant pressure gauge | Blower air volume (m3/min) | Blower Motor rated output (number of poles) (kW) | Blower external static pressure (Pa) | Blower model | Number of blowers (units) | Air side heat exchanger model | Lubricating oil type | Legal refrigeration capacity (tons) | Water side heat exchanger model | Exterior (Munsell symbol) | Dimensions Height (mm) | Dimensions Width (mm) | Dimensions Depth (mm) | Compressor Motor rated output (number of poles) (kW) | Compressor Lubricating oil temperature adjustment device | Compressor model | Number of compressors (units) | Refrigerant control device | Refrigerant type | Refrigerant amount (kg) | Cooling capacity (kW) | Cooling COP | Protective device (protective control function) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RCUNP75AV1 |
Available upon quote |
No notification required |
2.25 |
With operation switch, remote control - with local switch (remote control contacts are available on-site, remote control is optional) |
Red: Driving |
Electronic temperature controller (outlet water temperature control) |
100~36・Stop |
Not included (with connection port and segment display function) |
90 |
0.1 (10) ×2 |
0 |
Propeller fan |
2 |
Multi-passage cross-fin type |
FVC68D |
0.96 |
Plate type |
Natural gray (1.0Y 8.5/0.5) |
1,380 |
950 |
370 |
2.0 (6) ×1 cycle |
Oil heater (52W) |
Scroll |
1 |
Electronic expansion valve |
R410A |
3 |
7.5 |
3.33 |
High-pressure pressure cutoff device, low-pressure pressure cutoff control, antifreeze control, winter pump automatic operation control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse |
|
RCUNP125AV1 |
Available upon quote |
No notification required |
3.9 |
With operation switch, remote control - with local switch (remote control contacts are available on-site, remote control is optional) |
Red: Driving |
Electronic temperature controller (outlet water temperature control) |
100~22・Stop |
Not included (with connection port and segment display function) |
105 |
0.1 (10) ×2 |
0 |
Propeller fan |
2 |
Multi-passage cross-fin type |
FVC68D |
1.58 |
Plate type |
Natural gray (1.0Y 8.5/0.5) |
1,380 |
950 |
370 |
3.5 (6) ×1 cycle |
Oil heater (52W) |
Scroll |
1 |
Electronic expansion valve |
R410A |
3 |
12.5 |
3.2 |
High-pressure pressure cutoff device, low-pressure pressure cutoff control, antifreeze control, winter pump automatic operation control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse |
|
RCUNP190AV1 |
Available upon quote |
No notification required |
6 |
With operation switch, remote control - with local switch (remote control contacts are available on-site, remote control is optional) |
Red: Driving |
Electronic temperature controller (outlet water temperature control) |
100~36・Stop |
Not included (with connection port and segment display function) |
190 |
0.42 (8) ×1 |
0 |
Propeller fan |
1 |
Multi-passage cross-fin type |
FVC68D |
2 |
Plate type |
Natural gray (1.0Y 8.5/0.5) |
1,675 |
950 |
765 |
5.1 (6) ×1 cycle |
Oil heater (40.8W×2) |
Scroll |
1 |
Electronic expansion valve |
R410A |
5.5 |
19 |
3 |
High-pressure pressure cutoff device, low-pressure pressure cutoff control, antifreeze control, winter pump automatic operation control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse |
|
RCUNP250AV1 |
Available upon quote |
No notification required |
8.4 |
With operation switch, remote control - with local switch (remote control contacts are available on-site, remote control is optional) |
Red: Driving |
Electronic temperature controller (outlet water temperature control) |
100~27・Stop |
Not included (with connection port and segment display function) |
205 |
0.52 (8) ×1 |
0 |
Propeller fan |
1 |
Multi-passage cross-fin type |
FVC68D |
3.04 |
Plate type |
Natural gray (1.0Y 8.5/0.5) |
1,675 |
950 |
765 |
7.2 (6) ×1 cycle |
Oil heater (40.8W×2) |
Scroll |
1 |
Electronic expansion valve |
R410A |
5.5 |
Twenty five |
2.97 |
High-pressure pressure cutoff device, low-pressure pressure cutoff control, antifreeze control, winter pump automatic operation control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse |
|
RCUNP375AV1 |
Available upon quote |
No notification required |
12.1 |
With operation switch, remote control - with local switch (remote control contacts are available on-site, remote control is optional) |
Red: Driving |
Electronic temperature controller (outlet water temperature control) |
100~24・Stop |
Not included (with connection port and segment display function) |
240 |
0.34 (8) ×2 |
0 |
Propeller fan |
2 |
Multi-passage cross-fin type |
FVC68D |
4.3 |
Plate type |
Natural gray (1.0Y 8.5/0.5) |
1,675 |
1,210 |
765 |
10.4 (6) ×1 cycle |
Oil heater (40.8W×2) |
Scroll |
1 |
Electronic expansion valve |
R410A |
9.5 |
37.5 |
3.09 |
High-pressure pressure cutoff device, low-pressure pressure cutoff control, antifreeze control, winter pump automatic operation control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse |
|
RCUNP500AV1 |
Available upon quote |
No notification required |
16.8 |
With operation switch, remote control - with local switch (remote control contacts are available on-site, remote control is optional) |
Red: Driving |
Electronic temperature controller (outlet water temperature control) |
100~13・Stop |
Not included (with connection port and segment display function) |
365 |
0.62 (8) ×2 |
0 |
Propeller fan |
2 |
Multi-passage cross-fin type |
FVC68D |
6.16 |
Plate type |
Natural gray (1.0Y 8.5/0.5) |
1,675 |
1,600 |
765 |
(7.1+7.1 (6) ) ×1 cycle |
Oil heater (40.8W×4) |
Scroll |
2 |
Electronic expansion valve |
R410A |
13 |
50 |
2.97 |
High-pressure pressure cutoff device, low-pressure pressure cutoff control, antifreeze control, winter pump automatic operation control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
38.9hrs
Company Review