■Summary

Improved rated cooling COP for all models. Achieves high energy savings by improving performance during low-load operation. Furthermore, module control functions are standard equipment.

■ Hitachi's new technology realizes high rated cooling COP

The rated cooling COP has been improved for all models by installing a high-efficiency inverter scroll compressor and improving the refrigeration cycle and water side heat exchanger.

■Low load performance improvement path structure

Adopts a heat exchanger path structure that maximizes heat exchanger performance during low-load operation. After dividing the heat exchanger into upper and lower stages, the flow path becomes narrower toward the downstream of the heat exchanger, increasing the refrigerant flow rate and improving the heat transfer coefficient. Cooling capacity has been increased to improve energy efficiency.

■Σ (Sigma) shape heat exchanger

Two-fan structure to improve efficiency during low load operation. We have adopted a Σ (sigma) shaped heat exchanger that maximizes the effectiveness of this two-fan structure, improving heat exchanger performance.

■Long bell mouth structure

The multi-stage expansion structure greatly reduces fan input by smoothing the flow of air. Furthermore, by adopting a long bell mouth, air leakage is suppressed and high efficiency is achieved over a wide operating range.

■Improved low-load operation efficiency

The oil distribution method to the compressor mechanism has been improved (optimized oil supply amount) to suppress excess oil and improve efficiency in the high-speed rotation range, while improving sealing performance during low-speed operation (low load). We also aimed to improve efficiency during operation.

■Can control up to 8 modules in 1 group (maximum cooling capacity 400kW)

Equipped with module control function as standard. A dedicated controller for controlling the number of units is not required. (It is necessary to input operation commands remotely.)

■Number of units control function

Operate the number of machines commensurate with the load.

■Rotation function

The operating time of each module will be monitored and rotation will be carried out according to the operating time.

■Operation at abnormal stop

You can avoid the risk of complete stoppage. Disconnect the module that has stopped abnormally from control and continue operation with the normal module.

■Can be transported using an elevator

It can be transported using an 11-seater elevator. (Excluding type 500)

■Built-in active filter for harmonic countermeasures available (can be modified) (75 and 125 types excluded)

To deal with harmonics, we have prepared a built-in active filter that can be installed inside the chiller unit. (It will be shipped built into the main body.)

  • Product

    Chiller unit Air-cooled cooling only (standard/inverter)

Share this product


1160+ people viewing

Last viewed: 2 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

6 Models of Chiller unit Air-cooled cooling only (standard/inverter)

Click on the part number for more information about each product

Image Part Number Price (excluding tax) High Pressure Gas Safety Act classification Electrical characteristics Power consumption (kW) Operation adjustment device Operation switch Operation adjustment device indicator light Operation adjustment device Water temperature adjustment device Operation adjustment device capacity control range (%) Operation adjustment device Refrigerant pressure gauge Blower air volume (m3/min) Blower Motor rated output (number of poles) (kW) Blower external static pressure (Pa) Blower model Number of blowers (units) Air side heat exchanger model Lubricating oil type Legal refrigeration capacity (tons) Water side heat exchanger model Exterior (Munsell symbol) Dimensions Height (mm) Dimensions Width (mm) Dimensions Depth (mm) Compressor Motor rated output (number of poles) (kW) Compressor Lubricating oil temperature adjustment device Compressor model Number of compressors (units) Refrigerant control device Refrigerant type Refrigerant amount (kg) Cooling capacity (kW) Cooling COP Protective device (protective control function)
Chiller unit Air-cooled cooling only (standard/inverter)-Part Number-RCUNP75AV1

RCUNP75AV1

Available upon quote

No notification required

2.25

With operation switch, remote control - with local switch (remote control contacts are available on-site, remote control is optional)

Red: Driving
Orange: Alarm

Electronic temperature controller (outlet water temperature control)

100~36・Stop

Not included (with connection port and segment display function)

90

0.1 (10) ×2

0

Propeller fan

2

Multi-passage cross-fin type

FVC68D

0.96

Plate type

Natural gray (1.0Y 8.5/0.5)

1,380

950

370

2.0 (6) ×1 cycle

Oil heater (52W)

Scroll

1

Electronic expansion valve

R410A

3

7.5

3.33

High-pressure pressure cutoff device, low-pressure pressure cutoff control, antifreeze control, winter pump automatic operation control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse

Chiller unit Air-cooled cooling only (standard/inverter)-Part Number-RCUNP125AV1

RCUNP125AV1

Available upon quote

No notification required

3.9

With operation switch, remote control - with local switch (remote control contacts are available on-site, remote control is optional)

Red: Driving
Orange: Alarm

Electronic temperature controller (outlet water temperature control)

100~22・Stop

Not included (with connection port and segment display function)

105

0.1 (10) ×2

0

Propeller fan

2

Multi-passage cross-fin type

FVC68D

1.58

Plate type

Natural gray (1.0Y 8.5/0.5)

1,380

950

370

3.5 (6) ×1 cycle

Oil heater (52W)

Scroll

1

Electronic expansion valve

R410A

3

12.5

3.2

High-pressure pressure cutoff device, low-pressure pressure cutoff control, antifreeze control, winter pump automatic operation control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse

Chiller unit Air-cooled cooling only (standard/inverter)-Part Number-RCUNP190AV1

RCUNP190AV1

Available upon quote

No notification required

6

With operation switch, remote control - with local switch (remote control contacts are available on-site, remote control is optional)

Red: Driving
Orange: Alarm

Electronic temperature controller (outlet water temperature control)

100~36・Stop

Not included (with connection port and segment display function)

190

0.42 (8) ×1

0

Propeller fan

1

Multi-passage cross-fin type

FVC68D

2

Plate type

Natural gray (1.0Y 8.5/0.5)

1,675

950

765

5.1 (6) ×1 cycle

Oil heater (40.8W×2)

Scroll

1

Electronic expansion valve

R410A

5.5

19

3

High-pressure pressure cutoff device, low-pressure pressure cutoff control, antifreeze control, winter pump automatic operation control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse

Chiller unit Air-cooled cooling only (standard/inverter)-Part Number-RCUNP250AV1

RCUNP250AV1

Available upon quote

No notification required

8.4

With operation switch, remote control - with local switch (remote control contacts are available on-site, remote control is optional)

Red: Driving
Orange: Alarm

Electronic temperature controller (outlet water temperature control)

100~27・Stop

Not included (with connection port and segment display function)

205

0.52 (8) ×1

0

Propeller fan

1

Multi-passage cross-fin type

FVC68D

3.04

Plate type

Natural gray (1.0Y 8.5/0.5)

1,675

950

765

7.2 (6) ×1 cycle

Oil heater (40.8W×2)

Scroll

1

Electronic expansion valve

R410A

5.5

Twenty five

2.97

High-pressure pressure cutoff device, low-pressure pressure cutoff control, antifreeze control, winter pump automatic operation control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse

Chiller unit Air-cooled cooling only (standard/inverter)-Part Number-RCUNP375AV1

RCUNP375AV1

Available upon quote

No notification required

12.1

With operation switch, remote control - with local switch (remote control contacts are available on-site, remote control is optional)

Red: Driving
Orange: Alarm

Electronic temperature controller (outlet water temperature control)

100~24・Stop

Not included (with connection port and segment display function)

240

0.34 (8) ×2

0

Propeller fan

2

Multi-passage cross-fin type

FVC68D

4.3

Plate type

Natural gray (1.0Y 8.5/0.5)

1,675

1,210

765

10.4 (6) ×1 cycle

Oil heater (40.8W×2)

Scroll

1

Electronic expansion valve

R410A

9.5

37.5

3.09

High-pressure pressure cutoff device, low-pressure pressure cutoff control, antifreeze control, winter pump automatic operation control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse

Chiller unit Air-cooled cooling only (standard/inverter)-Part Number-RCUNP500AV1

RCUNP500AV1

Available upon quote

No notification required

16.8

With operation switch, remote control - with local switch (remote control contacts are available on-site, remote control is optional)

Red: Driving
Orange: Alarm

Electronic temperature controller (outlet water temperature control)

100~13・Stop

Not included (with connection port and segment display function)

365

0.62 (8) ×2

0

Propeller fan

2

Multi-passage cross-fin type

FVC68D

6.16

Plate type

Natural gray (1.0Y 8.5/0.5)

1,675

1,600

765

(7.1+7.1 (6) ) ×1 cycle

Oil heater (40.8W×4)

Scroll

2

Electronic expansion valve

R410A

13

50

2.97

High-pressure pressure cutoff device, low-pressure pressure cutoff control, antifreeze control, winter pump automatic operation control, discharge gas overheating prevention control, overcurrent protection control, compressor power circuit fuse, operation circuit fuse

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Chiller Units Products

Other products of Kyushu Kiden Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Kyushu Kiden Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

38.9hrs


Company Review

5.0
  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree