For clean rooms: Tempclean/air-cooled floor-standing separate type-EP-AP224CSP1
For clean rooms: Tempclean/air-cooled floor-standing separate type-Kyushu Kiden Co., Ltd.

For clean rooms: Tempclean/air-cooled floor-standing separate type
Kyushu Kiden Co., Ltd.


About This Product

■Summary Temp Clean makes your work space both clean and comfortable. We meet the needs of precision and electronic industries that require cleanliness standards of ISO Class 7 and 8 (formerly US Federal Standards Class 10,000 and 100,000). ■Consideration of airtightness The adoption of a filter guide rail prevents the gasket from peeling up when installing the HEPA filter, giving consideration to ease of installation and airtightness. Furthermore, by adopting a filter holding structure, we have taken into consideration the airtightness of the HEPA filter mounting area. ■Ease of duct construction We adopted a top-blown duct, which makes duct construction easier. We also accept orders for conventional front-blown ducts. ■Using a HEPA filter The standard lineup of HEPA filters (optional) is a low pressure drop high performance HEPA filter [counting method 99.97% (0.3μm)]. ■A wealth of application functions - Easy remote operation by simply adding a remote control (optional). - Room temperature can also be controlled using a remote control thermometer (built-in remote control) or remote sensor (optional). - External input signals for remote operation and output signals for display are provided as standard terminals, which saves on-site construction work. ■Limit the set temperature range A function to set the upper and lower limits of temperature settings using the operation panel. By limiting the temperature setting range on the operation panel, we prevent overcooling and overheating and support energy conservation. ■Automatically restore set temperature Even if you change the set temperature and temporarily increase the heating or cooling, if you set the automatic return time, the temperature will automatically return to the initial setting and prevent over-cooling or over-warming. ■Operation lock function Restricts operations from the operation panel. Prevents changes in "set temperature" and "operation switching" caused by erroneous operations. ■Timer function to prevent forgetting to turn off A function that automatically stops operation after a certain period of time has passed since the start of operation. The setting time can be set from 30 minutes to 24 hours. ■Multifunctional operation panel (5 to 10 horsepower equivalent only) A multi-function remote control is used on the operation panel. Various power saving settings are possible with easy operation. We have considered ease of management by visualizing the effects. ■Abundant power saving functions Smartly save power with the "power save button" on the operation panel. In addition to conventional power saving functions, capacity control and intermittent operation control are newly added. You can select the power saving function according to the usage environment.

  • Product

    For clean rooms: Tempclean/air-cooled floor-standing separate type

Share this product


710+ people viewing

Last viewed: 1 hour ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

8 Models of For clean rooms: Tempclean/air-cooled floor-standing separate type

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Blower air volume (m3/min) Blower external static pressure (Pa) Blower motor output (kW) Capacity/model name (equivalent horsepower) Compressor crankcase heater (W) Compressor model Compressor motor output (kW) Cooling capacity (kW) Dimensions Depth (mm) Dimensions Height (mm) Dimensions Width (mm) Dividable height (mm) Electrical characteristics Cooling operating current (A) Electrical characteristics Cooling power factor (%) Electrical characteristics Heating power factor (%) Electrical characteristics Operating current during heating (A) Electrical characteristics Power consumption during cooling (kW) Electrical characteristics Power consumption during heating (kW) Electrical characteristics Starting current (A) Energy consumption efficiency COP (cooling/heating average) Heating capacity (kW) Low temperature heating capacity (kW) Model Piping dimensions Refrigerant gas piping (mm) Piping dimensions Refrigerant liquid piping (mm) Piping dimensions drain Power supply Product mass (kg) Refrigerant Sensible heat ratio (SHF)
For clean rooms: Tempclean/air-cooled floor-standing separate type-Part Number-EP-AP224CSP1

EP-AP224CSP1

Available upon quote 65 0 1.5×1 224 type (8) - - - 20.0 (22.4) 500+150 1,700+740 950 1,745+740 23.1/22.7 86/87 86/87 22.1/21.7 6.88/6.85 6.57/6.54 50/44 3.16/3.18 22.4 (25.0) 20 Indoor unit Φ19.05 (φ22.2) Φ9.52 (φ12.7) Rc1 Three phase 200V 50/60Hz 145+74 R410A 0.81
For clean rooms: Tempclean/air-cooled floor-standing separate type-Part Number-RAS-AP224CHV1

RAS-AP224CHV1

Available upon quote 165 - 0.26×1 224 type (8) 40.8×2 Fully enclosed type 4.21 20.0 (22.4) 765 1,675 950 - 23.1/22.7 86/87 86/87 22.1/21.7 6.88/6.85 6.57/6.54 15 3.16/3.18 22.4 (25.0) 20 Outdoor unit Φ19.05 (φ22.2) Φ9.52 (φ12.7) - Three phase 200V 50/60Hz 185 R410A 0.81
For clean rooms: Tempclean/air-cooled floor-standing separate type-Part Number-EP-AP280CSP1

EP-AP280CSP1

Available upon quote 75 0 1.5×1 280 type (10) - - - 25.0 (28.0) 500+150 1,700+740 1,100 1,745+740 28.9/28.5 87/88 87/88 25.8/25.4 8.72/8.68 7.77/7.73 50/44 3.24/3.25 28.0 (31.5) 25.2 Indoor unit Φ22.2 (φ25.4) Φ9.52 (φ12.7) Rc1 Three phase 200V 50/60Hz 160+84 R410A 0.78
For clean rooms: Tempclean/air-cooled floor-standing separate type-Part Number-RAS-AP280CHV1

RAS-AP280CHV1

Available upon quote 170 - 0.28×1 280 type (10) 40.8×2 Fully enclosed type 6.43 25.0 (28.0) 765 1,675 950 - 28.9/28.5 87/88 87/88 25.8/25.4 8.72/8.68 7.77/7.73 15 3.24/3.25 28.0 (31.5) 25.2 Outdoor unit Φ22.2 (φ25.4) Φ9.52 (φ12.7) - Three phase 200V 50/60Hz 185 R410A 0.78
For clean rooms: Tempclean/air-cooled floor-standing separate type-Part Number-EP-AP450CSP1

EP-AP450CSP1

Available upon quote 125 0 3.7×1 450 type (16) - - - 40.0 (45.0) 750+230 1,870+795 1,100 1,900+795 56.1/54.8 87/88 86/88 47.3/45.6 16.9/16.7 14.1/13.9 135/116 2.78/2.82 45.0 (50.0) 38.7 Indoor unit Φ28.58 (φ31.75) Φ12.7 (φ15.88) Rc1 Three phase 200V 50/60Hz 234+124 R410A 0.79
For clean rooms: Tempclean/air-cooled floor-standing separate type-Part Number-RAS-AP450CHV1

RAS-AP450CHV1

Available upon quote 256 - 0.39×2 450 type (16) 40.8×4 Fully enclosed type 5.43×2 40.0 (45.0) 765 1,675 1,210 - 56.1/54.8 87/88 86/88 47.3/45.6 16.9/16.7 14.1/13.9 35 2.78/2.82 45.0 (50.0) 38.7 Outdoor unit Φ28.58 (φ31.75) Φ12.7 (φ15.88) - Three phase 200V 50/60Hz 305 R410A 0.79
For clean rooms: Tempclean/air-cooled floor-standing separate type-Part Number-EP-AP560CSP1

EP-AP560CSP1

Available upon quote 145 0 5.5×1 560 type (20) - - - 50.0 (56.0) 750+230 1,870+795 1,400 1,900+795 68.8/66.9 86/88 86/88 58.1/56.4 20.5/20.4 17.3/17.2 203/167 2.84/2.86 56.0 (63.0) 46.4 Indoor unit Φ28.58 (φ31.75) Φ15.88 (φ19.05) Rc1 Three phase 200V 50/60Hz 284+148 R410A 0.77
For clean rooms: Tempclean/air-cooled floor-standing separate type-Part Number-RAS-AP560CHV1

RAS-AP560CHV1

Available upon quote 329 - 0.48×2 560 type (20) 40.8×4 Fully enclosed type 7.15×2 50.0 (56.0) 765 1,675 1,600 - 68.8/66.9 86/88 86/88 58.1/56.4 20.5/20.4 17.3/17.2 35 2.84/2.86 56.0 (63.0) 46.4 Outdoor unit Φ28.58 (φ31.75) Φ15.88 (φ19.05) - Three phase 200V 50/60Hz 359 R410A 0.77

Click on the part number for more information about each product