Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)-RP-AP224CHVD
Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)-Kyushu Kiden Co., Ltd.

Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)
Kyushu Kiden Co., Ltd.


About This Product

■Saving construction work No pulley/belt adjustment required ■Easy maintenance No maintenance or replacement of pulley belts required ■Achieving high APF2015 and high COP By adopting a DC fan motor, we have achieved a high APF2015 and high COP. ■Reducing power consumption A DC motor is used for the indoor fan motor. By improving the low-speed performance of the compressor and optimizing refrigeration cycle control, we have significantly reduced the amount of electricity consumed during each period. ■Standard motor can handle high static pressure Conventional models required a motor upgrade to handle high static pressure, but with the beltless system, the standard motor can handle high static pressure. ■Fan rotation speed can be set from the operation panel The rotation speed can be changed on site during trial operation or even after delivery, depending on the external static pressure and air volume. ■Expanding the range of standard support for external input/output - Two new output terminals are standard equipment (selectable from ◎ in the table below). Previously, it was necessary to prepare auxiliary relays on site, but terminal extraction is now standard, and output settings can be easily made from the operation panel. - Can be further expanded with the optional "external input/output signal extraction kit" and "compressor capacity control analog input connection kit". - Easy remote operation by simply adding a remote control (optional). Room temperature can also be controlled using a remote control thermometer (built into the remote control) or a remote sensor (optional). ■A wealth of optional features Various heaters, spray humidifiers, and high-performance filters for back suction, which were previously shipped built-in to the main unit as special orders, are now available as options. Additionally, a suction square duct flange (fresh air intake) and an external input/output signal extraction kit are now available as options. ■ Consideration of design freedom with long piping Achieves an actual refrigerant piping length of 165m (equivalent length of 190m) and a height difference of up to 50m (40m when the outdoor unit is on the bottom). Furthermore, if the outdoor unit is installed above the indoor unit, a maximum height difference of 90m is possible upon request. More flexible design is now possible even for large properties. ■Supports installation of outdoor units on each floor With three high static pressure settings (on-site setting) of 80Pa, 60Pa, and 30Pa, it is now possible to accommodate a wide variety of installations on each floor.

  • Product

    Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)

Share this product


620+ people viewing

Last viewed: 1 minute ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

4 Models of Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Capacity/model name (equivalent horsepower) Compressor model Cooling performance Cooling capacity (kW) Cooling performance Operating current (A) Cooling performance Power consumption (kW) Cooling performance Power factor (%) Crankcase heater Drain piping Heating performance Heating capacity (kW) Heating performance Low temperature heating capacity (kW) Heating performance Operating current (A) Heating performance Power consumption (kW) Heating performance power factor (%) Indoor unit Air blower External static pressure (Pa) Indoor unit Air blower Motor output x number of units (kW) Indoor unit blower air volume (m3/min) Indoor unit outer diameter dimension (mm) Indoor unit product mass (kg) Motor output (W) Outdoor unit Air blower Motor output x number of units (kW) Outdoor unit Amount of refrigerant filled at time of shipment (kg) Outdoor unit air blower air volume (m3/min) Outdoor unit outer diameter dimension (mm) Outdoor unit product mass (kg) Power supply Sensible heat ratio (SHF) Sound power level Indoor unit (db (A) ) Sound power level Outdoor unit (db (A) ) Starting current (A) Outdoor unit Year-round energy consumption efficiency APF2015
Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)-Part Number-RP-AP224CHVD

RP-AP224CHVD

Available upon quote 224 type (8) Fully enclosed type 20.0 (22.4) 19.6 5.97 88 4.08×2 Rc1 22.4 (25.0) 20 18.7 5.71 88 30 2.2×1 65 950×500×1,712 140 4.21 0.26 5 165 950×765×1,675 185 Three phase 200V 50/60Hz 0.81 71 80 15 4.6
Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)-Part Number-RP-AP280CHVD

RP-AP280CHVD

Available upon quote 280 type (10) Fully enclosed type 25.0 (28.0) 25.9 7.9 88 4.08×2 Rc1 28.0 (31.5) 25.2 23.2 7.08 88 30 2.2×1 75 1,100×500×1,712 155 6.43 0.28 5 170 950×765×1,675 185 Three phase 200V 50/60Hz 0.78 72 82 15 4.8
Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)-Part Number-RP-AP450CHVD

RP-AP450CHVD

Available upon quote 450 type (16) Fully enclosed type 40.0 (45.0) 45.7 14.1 89 4.08×2 Rc1 45.0 (50.0) 38.7 37.1 11.3 88 30 3.7×1 125 1,100×500×1,712 230 5.43×2 0.39×2 9.9 256 1,210×765×1,675 305 Three phase 200V 50/60Hz 0.79 77 85 35 3.9
Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)-Part Number-RP-AP560CHVD

RP-AP560CHVD

Available upon quote 560 type (20) Fully enclosed type 50.0 (56.0) 57.1 17.6 89 4.08×2 Rc1 56.0 (63.0) 46.4 47.7 14.7 89 30 5.5×1 145 1,400×500×1,712 265 7.15×2 0.48×2 11.3 329 1,600×765×1,675 359 Three phase 200V 50/60Hz 0.77 77 84 35 4

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Kyushu Kiden Co., Ltd.


View more products of Kyushu Kiden Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree