All Categories

History

Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)-RP-AP224CHVD
Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)-Kyushu Kiden Co., Ltd.

Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)
Kyushu Kiden Co., Ltd.

Kyushu Kiden Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

38.9hours


About This Product

■Saving construction work

No pulley/belt adjustment required

■Easy maintenance

No maintenance or replacement of pulley belts required

■Achieving high APF2015 and high COP

By adopting a DC fan motor, we have achieved a high APF2015 and high COP.

■Reducing power consumption

A DC motor is used for the indoor fan motor. By improving the low-speed performance of the compressor and optimizing refrigeration cycle control, we have significantly reduced the amount of electricity consumed during each period.

■Standard motor can handle high static pressure

Conventional models required a motor upgrade to handle high static pressure, but with the beltless system, the standard motor can handle high static pressure.

■Fan rotation speed can be set from the operation panel

The rotation speed can be changed on site during trial operation or even after delivery, depending on the external static pressure and air volume.

■Expanding the range of standard support for external input/output

- Two new output terminals are standard equipment (selectable from ◎ in the table below). Previously, it was necessary to prepare auxiliary relays on site, but terminal extraction is now standard, and output settings can be easily made from the operation panel. - Can be further expanded with the optional "external input/output signal extraction kit" and "compressor capacity control analog input connection kit". - Easy remote operation by simply adding a remote control (optional). Room temperature can also be controlled using a remote control thermometer (built into the remote control) or a remote sensor (optional).

■A wealth of optional features

Various heaters, spray humidifiers, and high-performance filters for back suction, which were previously shipped built-in to the main unit as special orders, are now available as options. Additionally, a suction square duct flange (fresh air intake) and an external input/output signal extraction kit are now available as options.

■ Consideration of design freedom with long piping

Achieves an actual refrigerant piping length of 165m (equivalent length of 190m) and a height difference of up to 50m (40m when the outdoor unit is on the bottom). Furthermore, if the outdoor unit is installed above the indoor unit, a maximum height difference of 90m is possible upon request. More flexible design is now possible even for large properties.

■Supports installation of outdoor units on each floor

With three high static pressure settings (on-site setting) of 80Pa, 60Pa, and 30Pa, it is now possible to accommodate a wide variety of installations on each floor.

  • Product

    Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)

Share this product


880+ people viewing

Last viewed: 5 minutes ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

4 Models of Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Sensible heat ratio (SHF) Sound power level Outdoor unit (db (A) ) Sound power level Indoor unit (db (A) ) Power supply Motor output (W) Year-round energy consumption efficiency APF2015 Heating performance Operating current (A) Heating performance Power consumption (kW) Heating performance Heating capacity (kW) Heating performance power factor (%) Heating performance Low temperature heating capacity (kW) Capacity/model name (equivalent horsepower) Outdoor unit air blower air volume (m3/min) Outdoor unit Air blower Motor output x number of units (kW) Outdoor unit product mass (kg) Outdoor unit outer diameter dimension (mm) Outdoor unit Amount of refrigerant filled at time of shipment (kg) Indoor unit blower air volume (m3/min) Indoor unit Air blower Motor output x number of units (kW) Indoor unit Air blower External static pressure (Pa) Indoor unit product mass (kg) Indoor unit outer diameter dimension (mm) Starting current (A) Outdoor unit Compressor model Cooling performance Operating current (A) Cooling performance Power consumption (kW) Cooling performance Power factor (%) Cooling performance Cooling capacity (kW) Drain piping Crankcase heater
Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)-Part Number-RP-AP224CHVD

RP-AP224CHVD

Available upon quote

0.81

80

71

Three phase 200V 50/60Hz

4.21

4.6

18.7

5.71

22.4 (25.0)

88

20

224 type (8)

165

0.26

185

950×765×1,675

5

65

2.2×1

30

140

950×500×1,712

15

Fully enclosed type

19.6

5.97

88

20.0 (22.4)

Rc1

4.08×2

Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)-Part Number-RP-AP280CHVD

RP-AP280CHVD

Available upon quote

0.78

82

72

Three phase 200V 50/60Hz

6.43

4.8

23.2

7.08

28.0 (31.5)

88

25.2

280 type (10)

170

0.28

185

950×765×1,675

5

75

2.2×1

30

155

1,100×500×1,712

15

Fully enclosed type

25.9

7.9

88

25.0 (28.0)

Rc1

4.08×2

Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)-Part Number-RP-AP450CHVD

RP-AP450CHVD

Available upon quote

0.79

85

77

Three phase 200V 50/60Hz

5.43×2

3.9

37.1

11.3

45.0 (50.0)

88

38.7

450 type (16)

256

0.39×2

305

1,210×765×1,675

9.9

125

3.7×1

30

230

1,100×500×1,712

35

Fully enclosed type

45.7

14.1

89

40.0 (45.0)

Rc1

4.08×2

Achieves energy savings, construction and maintenance savings Floor-standing separate type/air cooling (beltless method)-Part Number-RP-AP560CHVD

RP-AP560CHVD

Available upon quote

0.77

84

77

Three phase 200V 50/60Hz

7.15×2

4

47.7

14.7

56.0 (63.0)

89

46.4

560 type (20)

329

0.48×2

359

1,600×765×1,675

11.3

145

5.5×1

30

265

1,400×500×1,712

35

Fully enclosed type

57.1

17.6

89

50.0 (56.0)

Rc1

4.08×2

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Air Conditioners Products

Other products of Kyushu Kiden Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Kyushu Kiden Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

38.9hrs


Company Review

5.0
  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree