Cold/heat switchable type (TNX series)-RAS-AP224TNX
Cold/heat switchable type (TNX series)-Kyushu Kiden Co., Ltd.

Cold/heat switchable type (TNX series)
Kyushu Kiden Co., Ltd.


About This Product

■Summary Simultaneous cooling/heating multi for cold regions equipped with a new defrosting function and available in models ranging from 224 to 1,000. ■Equipped with the new "Auto Select Defrost" function, which intelligently uses three defrosting methods to maintain indoor comfort. Depending on the amount of frost formed, the system automatically selects three defrosting methods: Hitachi's unique "hot gas bypass defrosting", the new function "switching defrosting", and "reverse cycle defrosting" to improve comfort during heating. Drive wisely to avoid damage. ■[Versatility] Abundant product lineup No need to worry about cold weather (simultaneous heating and cooling type, for cold regions) [TNX series] has a lineup of 15 models ranging from 224 to 1000 types. With a complete product lineup, we can handle large office buildings, large hotels, etc. In addition, since models up to 450 are single units, there is no need for connection work between outdoor units. ■[Comfort] Frost amount detection function reduces the frequency of defrosting operation Inheriting the technology of the TN series, it uses a "frost detection function" to precisely detect the frost buildup on the outdoor unit. This reduces the frequency of defrosting operations, extending heating operation to a maximum of approximately 330 minutes. ■[Comfort] Controls room temperature drop by shifting the defrosting timing If one of the two refrigerant systems connected to H-LINK II is preparing for defrosting or is in the process of defrosting, the other refrigerant system will not perform defrosting operation until the defrosting operation is completed, and the two refrigerant systems will This prevents the defrosting operation from occurring at the same time. ■Prevents freezing of the outdoor unit base A frost/icing suppression heat exchanger is placed below the outdoor heat exchanger. During heating operation, medium-temperature liquid refrigerant is flowed before depressurization to suppress frost and ice formation at the bottom of the heat exchanger, thereby preventing freezing of the unit base. ■[Comfort] Improved stand-up performance the next day By defrosting the air before shutting down the previous day, you can quickly start up heating the next day. ■Realizes quick heating start-up With its high heating start-up performance, it provides a comfortable heating environment even on cold winter mornings. ■Large capacity + gas injection compressor By adopting a gas injection cycle for the scroll compressor, we have improved heating performance at low outside temperatures without using a combustor or electric heater. ■Hot gas bypass circuit Newly equipped with a hot gas bypass circuit. Defrosting operation can be performed without changing the four-way valve during defrosting operation, while maintaining the heating cycle. There are other model numbers as well.

  • Product

    Cold/heat switchable type (TNX series)

Share this product


1100+ people viewing

Last viewed: 3 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Cold/heat switchable type (TNX series)

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Blower motor output (kW) Blower rated air volume (m3/min) Capacity/model name (equivalent horsepower) Compressor motor output (kW) Electrical characteristics Operating current Cooling (A) Electrical characteristics Operating current Heating (A) Electrical characteristics Power consumption Cooling (kW) Electrical characteristics Power consumption Heating (kW) Electrical characteristics Power consumption Heating cryogenic temperature (kW) Electrical characteristics Power consumption Heating low temperature (kW) Electrical characteristics Power factor Cooling (%) Electrical characteristics Power factor Heating (%) Exterior color (Munsell symbol) Main piping size (cooling/heating switching system) Liquid (mm) Main piping size High and low pressure gas (mm) Main piping size Low pressure gas (mm) Maximum heating cryogenic capacity (kW) Maximum heating low temperature capacity (kW) Operating noise (dB (A) ) Outer diameter dimensions W×D×H (mm) Power specifications Product mass (kg) Rated cooling standard capacity (kW) Rated heating standard capacity (kW)
Cold/heat switchable type (TNX series)-Part Number-RAS-AP224TNX

RAS-AP224TNX

Available upon quote 0.34 181 224 type (8) 5.47 19.1 20.5 5.96 6.39 11 8.45 90 90 Natural gray (1.0Y 8.5/0.5) Φ9.52 Φ15.88 Φ19.05 25.3 (26.5) 23.7 (26.5) 79 950×765×1,755 Three phase 200V 222 22.4 26.5
Cold/heat switchable type (TNX series)-Part Number-RAS-AP280TNX

RAS-AP280TNX

Available upon quote 0.22×2 204 280 type (10) 3.79×2 26.7 28.3 8.32 8.82 16.4 12.4 90 90 Natural gray (1.0Y 8.5/0.5) Φ9.52 Φ19.05 Φ22.2 31.9 (33.5) 30.0 (33.5) 78 1,210×765×1,755 Three phase 200V 321 28 33.5
Cold/heat switchable type (TNX series)-Part Number-RAS-AP335TNX

RAS-AP335TNX

Available upon quote 0.24×2 219 335 type (12) 4.26×2 28.1 31.6 8.75 9.86 19.1 13.4 90 90 Natural gray (1.0Y 8.5/0.5) Φ12.7 Φ22.2 Φ25.4 38.0 (40.0) 35.8 (40.0) 80 1,210×765×1,755 Three phase 200V 321 33.5 40
Cold/heat switchable type (TNX series)-Part Number-RAS-AP400TNX

RAS-AP400TNX

Available upon quote 0.46×2 346 400 type (14) 5.08×2 34.6 39.5 10.8 12.3 22.2 15.6 90 90 Natural gray (1.0Y 8.5/0.5) Φ12.7 Φ22.2 Φ25.4 44.8 (47.5) 42.5 (47.5) 85 1,600×765×1,755 Three phase 200V 389 40 47.5
Cold/heat switchable type (TNX series)-Part Number-RAS-AP450TNX

RAS-AP450TNX

Available upon quote 0.52×2 362 450 type (16) 5.54×2 39.8 43 12.4 13.4 23.6 16.9 90 90 Natural gray (1.0Y 8.5/0.5) Φ12.7 Φ22.2 Φ28.58 48.2 (53.0) 47.5 (53.0) 86 1,600×765×1,755 Three phase 200V 389 45 53
Cold/heat switchable type (TNX series)-Part Number-RAS-AP500TNX

RAS-AP500TNX

Available upon quote (0.22×2) + (0.34) 204+181 500 type (18) (3.79×2) + (5.47) 45.2 49.1 14.1 15.3 27.4 20.9 90 90 Natural gray (1.0Y 8.5/0.5) Φ15.88 Φ22.2 Φ28.58 57.2 (60.0) 53.7 (60.0) 82 2,180×765×1,755 Three phase 200V 321+222 50 60
Cold/heat switchable type (TNX series)-Part Number-RAS-AP560TNX

RAS-AP560TNX

Available upon quote (0.24×2) + (0.34) 219+181 560 type (20) (4.26×2) + (5.47) 47.5 52.9 14.8 16.5 30.1 22.3 90 90 Natural gray (1.0Y 8.5/0.5) Φ15.88 Φ22.2 Φ28.58 63.3 (67.0) 60.0 (67.0) 83 2,180×765×1,755 Three phase 200V 321+222 56 67
Cold/heat switchable type (TNX series)-Part Number-RAS-AP615TNX

RAS-AP615TNX

Available upon quote (0.24×2) + (0.22×2) 219+204 Type 615 (22) (4.26×2) + (3.79×2) 54.8 62.5 17.1 19.5 35.5 26.9 90 90 Natural gray (1.0Y 8.5/0.5) Φ15.88 Φ25.4 Φ28.58 69.9 (75.0) 67.1 (75.0) 82 2,440×765×1,755 Three phase 200V 321+321 61.5 75
Cold/heat switchable type (TNX series)-Part Number-RAS-AP670TNX

RAS-AP670TNX

Available upon quote (0.24×2) ×2 219×2 670 type (24) (4.26×2) ×2 56.1 67.4 17.5 Twenty one 38.2 28.5 90 90 Natural gray (1.0Y 8.5/0.5) Φ15.88 Φ25.4 Φ28.58 76.0 (82.5) 73.8 (82.5) 83 2,440×765×1,755 Three phase 200V 321×2 67 82.5
Cold/heat switchable type (TNX series)-Part Number-RAS-AP730TNX

RAS-AP730TNX

Available upon quote (0.46×2) + (0.24×2) 346+219 730 type (26) (5.08×2) + (4.26×2) 61.9 71.2 19.3 22.2 41.3 29 90 90 Natural gray (1.0Y 8.5/0.5) Φ19.05 Φ25.4 Φ31.75 82.8 (87.5) 78.3 (87.5) 86 2,830×765×1,755 Three phase 200V 389+321 73 87.5

Click on the part number for more information about each product