Cold/heat switchable type (TN series)-RAS-AP224TN
Cold/heat switchable type (TN series)-Kyushu Kiden Co., Ltd.

Cold/heat switchable type (TN series)
Kyushu Kiden Co., Ltd.


About This Product

■Summary Demonstrates high heating performance even at low outside temperatures. Cooling/heating switching type multi for cold regions with improved comfort using a new defrosting method ■[Versatility] Abundant product lineup No need to worry about the cold (cooling/heating switching type, for cold regions) [TN series] has a lineup of models 224 to 1000. With a complete product lineup, we can handle large office buildings, large hotels, etc. In addition, the capacity of the single unit has been expanded compared to the conventional model, making it possible to install it compactly and eliminating the need for connection work between outdoor units. ■Realizes quick heating start-up With its high heating start-up performance, it provides a comfortable heating environment even on cold winter mornings. ■[Comfort] Frost amount detection function reduces the frequency of defrosting operation The "frost detection function" allows detailed detection of the frost buildup on the outdoor unit. This reduces the frequency of defrosting operations, extending heating operation to a maximum of approximately 330 minutes. Furthermore, it automatically switches between two defrosting methods depending on the amount of frost, and performs appropriate defrosting operation so as not to impair heating comfort. ■Suppression of temperature drop near the air outlet Depending on the amount of frost, it automatically switches between two defrosting methods: "hot gas bypass defrosting" and "reverse cycle defrosting", and performs appropriate defrosting operation so as not to impair heating comfort. . Hot gas bypass defrosting does not use residual heat from the indoor heat exchanger or piping, so it suppresses the temperature drop near the indoor unit outlet during defrosting. ■Prevents freezing of the outdoor unit base A frost/icing suppression heat exchanger is placed below the outdoor heat exchanger. During heating operation, medium-temperature liquid refrigerant is flowed before depressurization to prevent frost formation and icing at the bottom of the heat exchanger, thereby preventing freezing of the unit base. ■[Comfort] Controlling room temperature drop by shifting the defrosting timing If one of the two refrigerant systems connected to H-LINK II is preparing for defrosting or is in the process of defrosting, the other refrigerant system will not perform defrosting operation until the defrosting operation is completed, and the two refrigerant systems will This prevents the defrosting operation from occurring at the same time. ■[Comfort] Improved stand-up performance the next day By defrosting the air before shutting down the previous day, you can quickly start up heating the next day. There are other model numbers as well.

  • Product

    Cold/heat switchable type (TN series)

Share this product


1410+ people viewing

Last viewed: 3 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Cold/heat switchable type (TN series)

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) APF2015 (year-round energy consumption efficiency) Blower motor output (kW) Blower rated air volume (m3/min) Capacity/model name (equivalent horsepower) Compressor motor output (kW) Electrical characteristics Operating current Cooling (A) Electrical characteristics Operating current Heating (A) Electrical characteristics Power consumption Cooling (kW) Electrical characteristics Power consumption Heating (kW) Electrical characteristics Power consumption Heating cryogenic temperature (kW) Electrical characteristics Power consumption Heating low temperature (kW) Electrical characteristics Power factor Cooling (%) Electrical characteristics Power factor Heating (%) Exterior color (Munsell symbol) Main piping size (cooling/heating switching system) Gas (mm) Main piping size (cooling/heating switching system) Liquid (mm) Maximum heating cryogenic capacity (kW) Maximum heating low temperature capacity (kW) Operating noise (dB (A) ) Outer diameter dimensions W×D×H (mm) Power specifications Product mass (kg) Rated cooling standard capacity (kW) Rated heating standard capacity (kW)
Cold/heat switchable type (TN series)-Part Number-RAS-AP224TN

RAS-AP224TN

Available upon quote 6.3 0.34 181 224 type (8) 5.47 19.1 20.5 5.96 6.39 11 8.45 90 90 Natural gray (1.0Y 8.5/0.5) Φ19.05 Φ9.52 25.3 (26.5) 23.7 (26.5) 79 950×765×1,755 Three phase 200V 219 22.4 26.5
Cold/heat switchable type (TN series)-Part Number-RAS-AP280TN

RAS-AP280TN

Available upon quote 5.7 0.22×2 204 280 type (10) 3.79×2 26.7 28.3 8.32 8.82 16.4 12.4 90 90 Natural gray (1.0Y 8.5/0.5) Φ22.2 Φ9.52 31.9 (33.5) 30.0 (33.5) 78 1,210×765×1,755 Three phase 200V 317 28 33.5
Cold/heat switchable type (TN series)-Part Number-RAS-AP335TN

RAS-AP335TN

Available upon quote 6 0.24×2 219 335 type (12) 4.26×2 28.1 31.6 8.75 9.86 19.1 13.4 90 90 Natural gray (1.0Y 8.5/0.5) Φ25.4 Φ12.7 38.0 (40.0) 35.8 (40.0) 80 1,210×765×1,755 Three phase 200V 317 33.5 40
Cold/heat switchable type (TN series)-Part Number-RAS-AP400TN

RAS-AP400TN

Available upon quote 6 0.46×2 346 400 type (14) 5.08×2 34.6 39.5 10.8 12.3 22.2 15.6 90 90 Natural gray (1.0Y 8.5/0.5) Φ25.4 Φ12.7 44.8 (47.5) 42.5 (47.5) 85 1,600×765×1,755 Three phase 200V 386 40 47.5
Cold/heat switchable type (TN series)-Part Number-RAS-AP450TN

RAS-AP450TN

Available upon quote 6.3 0.52×2 362 450 type (16) 5.54×2 39.8 43 12.4 13.4 23.6 16.9 90 90 Natural gray (1.0Y 8.5/0.5) Φ28.58 Φ12.7 48.2 (53.0) 47.5 (53.0) 86 1,600×765×1,755 Three phase 200V 386 45 53
Cold/heat switchable type (TN series)-Part Number-RAS-AP500TN

RAS-AP500TN

Available upon quote 6 (0.22×2) + (0.34) 204+181 500 type (18) (3.79×2) + (5.47) 45.2 49.1 14.1 15.3 27.4 20.9 90 90 Natural gray (1.0Y 8.5/0.5) Φ28.58 Φ15.88 57.2 (60.0) 53.7 (60.0) 82 2,180×765×1,755 Three phase 200V 317+219 50 60
Cold/heat switchable type (TN series)-Part Number-RAS-AP560TN

RAS-AP560TN

Available upon quote 6.1 (0.24×2) + (0.34) 219+181 560 type (20) (4.26×2) + (5.47) 47.5 52.9 14.8 16.5 30.1 22.3 90 90 Natural gray (1.0Y 8.5/0.5) Φ28.58 Φ15.88 63.3 (67.0) 60.0 (67.0) 83 2,180×765×1,755 Three phase 200V 317+219 56 67
Cold/heat switchable type (TN series)-Part Number-RAS-AP615TN

RAS-AP615TN

Available upon quote 5.9 (0.24×2) + (0.22×2) 219+204 Type 615 (22) (4.26×2) + (3.79×2) 54.8 62.5 17.1 19.5 35.5 26.9 90 90 Natural gray (1.0Y 8.5/0.5) Φ28.58 Φ15.88 69.9 (75.0) 67.1 (75.0) 82 2,440×765×1,755 Three phase 200V 317+317 61.5 75
Cold/heat switchable type (TN series)-Part Number-RAS-AP670TN

RAS-AP670TN

Available upon quote 6 (0.24×2) ×2 219×2 670 type (24) (4.26×2) ×2 56.1 67.4 17.5 Twenty one 38.2 28.5 90 90 Natural gray (1.0Y 8.5/0.5) Φ28.58 Φ15.88 76.0 (82.5) 73.8 (82.5) 83 2,440×765×1,755 Three phase 200V 317×2 67 82.5
Cold/heat switchable type (TN series)-Part Number-RAS-AP730TN

RAS-AP730TN

Available upon quote 6 (0.46×2) + (0.24×2) 346+219 730 type (26) (5.08×2) + (4.26×2) 61.9 71.2 19.3 22.2 41.3 29 90 90 Natural gray (1.0Y 8.5/0.5) Φ31.75 Φ19.05 82.8 (87.5) 78.3 (87.5) 86 2,830×765×1,755 Three phase 200V 386+317 73 87.5

Click on the part number for more information about each product