Flex Multi-mini module cooling/heating switching type (SSM series)-RAS-AP224SSM
Flex Multi-mini module cooling/heating switching type (SSM series)-Kyushu Kiden Co., Ltd.

Flex Multi-mini module cooling/heating switching type (SSM series)
Kyushu Kiden Co., Ltd.


About This Product

■Summary Compact side flow model that can be connected in combination. Useful for building multi-systems in medium-sized buildings. ■ [Supports up to 1500 type (equivalent to 54 horsepower)] Side flow model that can be connected in combination to up to 1500 type (equivalent to 54 horsepower) in one system [Industry's first] [Hitachi original] Hitachi's proprietary control algorithm and newly designed housing allow for a lineup of up to 1500 side flow model outdoor unit combinations. In addition, since models up to 450 are single units, there is no need for connection work between outdoor units. ■Features ・[Easy to install] Hitachi's technology realizes miniaturization and improves installation efficiency. ・[High efficiency & energy saving] Achieves high efficiency and energy saving equivalent to conventional top flow models. ■ Installation freedom unique to the side flow model ・[Easy to install] Can be installed on a balcony ・Suitable for long piping. Maximum piping length (equivalent length) 150m ・[Easy to install] Can be installed compactly in a space along the wall ■[Comfort] Equipped with indoor heat exchanger "freeze cleaning" function [Hitachi original] Freeze the indoor heat exchanger to create frost, melt the accumulated frost, and remove dirt. It prevents clogging of heat exchangers and reduces air volume, contributing to maintaining a comfortable air environment. ■Night shift mode This mode is used when it is necessary to reduce driving noise, such as at night. When night shift mode is set in the function selection settings, when the outside temperature drops below 30°C during cooling operation, the compressor rotation speed and outdoor blower rotation speed are suppressed to reduce operating noise. ■Driving noise reduction mode If you set the operating noise reduction mode in the function selection settings, the operating noise will be reduced by suppressing the compressor rotation speed and outdoor fan rotation speed regardless of the outside temperature. The operating noise reduction mode can be set in 3 levels (operating noise reduction mode 1, 2, and 3). ■Smooth Drive 2.0 control Calculates the appropriate amount of refrigerant to be supplied to the outdoor unit based on the required load information from each indoor unit. In addition to smooth drive control that controls the rotation speed of the inverter compressor and supplies the appropriate amount of refrigerant to the indoor unit according to the required load, it is now possible to control the rotation speed of the compressor by adding more detailed room temperature information. . In addition to smooth drive control, we have also reduced the number of ON/OFF operations of the compressor during low-load operation, and achieved energy savings by operating smoothly. There are other model numbers as well.

  • Product

    Flex Multi-mini module cooling/heating switching type (SSM series)

Share this product


1130+ people viewing

Last viewed: 52 minutes ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Flex Multi-mini module cooling/heating switching type (SSM series)

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) APF2015 (year-round energy consumption efficiency) Blower motor output (kW) Blower rated air volume (m3/min) Capacity/model name (equivalent horsepower) Compressor motor output (kW) Electrical characteristics Operating current Cooling (A) Electrical characteristics Operating current Heating (A) Electrical characteristics Power consumption Cooling (kW) Electrical characteristics Power consumption Heating (kW) Electrical characteristics Power factor Cooling (%) Electrical characteristics Power factor Heating (%) Exterior color (Munsell symbol) Main piping size (cooling/heating switching system) Gas (mm) Main piping size (cooling/heating switching system) Liquid (mm) Maximum heating low temperature capacity (kW) Operating noise (cooling-heating) (dB (A) ) Outer diameter dimensions W×D×H (mm) Power specifications Product mass (kg) Rated cooling standard capacity (kW) Rated heating standard capacity (kW)
Flex Multi-mini module cooling/heating switching type (SSM series)-Part Number-RAS-AP224SSM

RAS-AP224SSM

Available upon quote 6 0.14×2 160 224 type (8) 5.39 19.4 18.7 6.19 5.95 92 92 Natural gray (1.0Y 8.5/0.5) Φ19.05 Φ9.52 19 78-79 1,050×420×1,650 Three phase 200V 188 22.4 Twenty five
Flex Multi-mini module cooling/heating switching type (SSM series)-Part Number-RAS-AP280SSM

RAS-AP280SSM

Available upon quote 5.7 0.19×2 185 280 type (10) 8.48 30.2 26.9 9.63 8.58 92 92 Natural gray (1.0Y 8.5/0.5) Φ22.2 Φ9.52 Twenty four 80-82 1,050×420×1,650 Three phase 200V 200 28 31.5
Flex Multi-mini module cooling/heating switching type (SSM series)-Part Number-RAS-AP335SSM

RAS-AP335SSM

Available upon quote 6 0.23×2 200 335 type (12) 11.5 33.6 40.8 10.7 13 92 92 Natural gray (1.0Y 8.5/0.5) Φ25.4 Φ12.7 27.5 80-83 1,050×420×1,650 Three phase 200V 205 33.5 37.5
Flex Multi-mini module cooling/heating switching type (SSM series)-Part Number-RAS-AP400SSM

RAS-AP400SSM

Available upon quote 5.9 0.40×2 250 400 type (14) 12.8 46.4 34.8 14.8 11.1 92 92 Natural gray (1.0Y 8.5/0.5) Φ25.4 Φ12.7 31.1 81-82 1,190×420×1,650 Three phase 200V 223 40 42.5
Flex Multi-mini module cooling/heating switching type (SSM series)-Part Number-RAS-AP450SSM

RAS-AP450SSM

Available upon quote 5.1 0.44×2 258 450 type (16) 14.1 51.1 44.9 16.3 14.3 92 92 Natural gray (1.0Y 8.5/0.5) Φ28.58 Φ12.7 34.7 83-85 1,190×420×1,650 Three phase 200V 231 45 47.5
Flex Multi-mini module cooling/heating switching type (SSM series)-Part Number-RAS-AP500SSM

RAS-AP500SSM

Available upon quote 5.8 (0.19×2) + (0.14×2) 185+160 500 type (18) 8.48+5.39 48.9 40.2 15.6 12.8 92 92 Natural gray (1.0Y 8.5/0.5) Φ28.58 Φ12.7 43 83-84 2,200×420×1,650 Three phase 200V 200+188 50 53
Flex Multi-mini module cooling/heating switching type (SSM series)-Part Number-RAS-AP560SSM

RAS-AP560SSM

Available upon quote 5.7 (0.19×2) ×2 185×2 560 type (20) 8.48×2 60.6 54 19.3 17.2 92 92 Natural gray (1.0Y 8.5/0.5) Φ28.58 Φ15.88 48 83-85 2,200×420×1,650 Three phase 200V 200×2 56 63
Flex Multi-mini module cooling/heating switching type (SSM series)-Part Number-RAS-AP615SSM

RAS-AP615SSM

Available upon quote 5.9 (0.23×2) + (0.19×2) 200+185 Type 615 (22) 11.5+8.48 64 67.8 20.4 21.6 92 92 Natural gray (1.0Y 8.5/0.5) Φ28.58 Φ15.88 51.5 83-86 2,200×420×1,650 Three phase 200V 205+200 61.5 69
Flex Multi-mini module cooling/heating switching type (SSM series)-Part Number-RAS-AP670SSM

RAS-AP670SSM

Available upon quote 5.9 (0.23×2) ×2 200×2 670 type (24) 11.5×2 67.1 87.2 21.4 27.8 92 92 Natural gray (1.0Y 8.5/0.5) Φ28.58 Φ15.88 56.5 83-86 2,200×420×1,650 Three phase 200V 205×2 67 77.5
Flex Multi-mini module cooling/heating switching type (SSM series)-Part Number-RAS-AP730SSM

RAS-AP730SSM

Available upon quote 5.9 (0.40×2) + (0.23×2) 250+200 730 type (26) 12.8+11.5 79.1 75.6 25.2 24.1 92 92 Natural gray (1.0Y 8.5/0.5) Φ31.75 Φ19.05 58.6 84-86 2,340×420×1,650 Three phase 200V 223+205 73 80

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Kyushu Kiden Co., Ltd.


View more products of Kyushu Kiden Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree