Flex multi simultaneous heating and cooling type (TGX/TSX/TZX series)-RAS-AP140TGX
Flex multi simultaneous heating and cooling type (TGX/TSX/TZX series)-Kyushu Kiden Co., Ltd.

Flex multi simultaneous heating and cooling type (TGX/TSX/TZX series)
Kyushu Kiden Co., Ltd.


About This Product

■Summary Simultaneous cooling/heating type FlexMulti compatible with various building air conditioning systems ■Energy saving performance due to heat recovery operation (during simultaneous cooling and heating operation) In a simultaneous heating and cooling system, the exhaust heat generated during cooling operation can be reused as heating energy, making it possible to reduce the power of the compressor. Particularly in the case of simultaneous cooling and heating operation under low load conditions such as mid-season, the closer the ratio of cooling and heating operation capacity is to 50%:50%, the greater the energy saving effect will be. The Flex Multi (simultaneous cooling/heating type) adopts the same technology as the cooling/heating switching type that aims to improve operating efficiency during low-load operation, resulting in simultaneous cooling/heating COP of up to 7.8 (for 335 type) for the high-efficiency TGX series. Even the high-efficiency TSX series has achieved a maximum of 7.6 (for 450-inch). ■[Energy saving] Hitachi's new technology achieves high COP with the same installation space as conventional models. The high-efficiency TGX series uses new technology to achieve high efficiency while maintaining the same footprint as conventional models. In addition, the high-efficiency TZX series achieves an even higher COP and is recommended for ZEB efforts. ■[Energy saving] Combining energy-saving technologies to significantly reduce power consumption Annual power consumption has been significantly reduced by improving the performance of the blower, heat exchanger, and compressor, as well as improving compressor control. Additionally, by reducing power consumption, CO2 emissions are significantly reduced. We have created a product with a lower environmental impact. ■[Comfort] Equipped with cold region function The high-efficiency TGX series maintains its rated heating capacity down to -7°C when used as a multi-purpose building mulch for general use. Furthermore, heating operation continues down to -25℃. Also, during cooling, the rated cooling capacity is maintained at up to 43℃ and continues operation up to 52℃. ■Designed to withstand wind speeds up to 60m/s We conducted a wind resistance performance test that reproduced strong winds during an actual typhoon. We have realized a housing structure that takes into consideration the large typhoons that have been increasing in recent years. There are other model numbers as well.

  • Product

    Flex multi simultaneous heating and cooling type (TGX/TSX/TZX series)

Share this product


1310+ people viewing

Last viewed: 3 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Flex multi simultaneous heating and cooling type (TGX/TSX/TZX series)

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Blower motor output (kW) Blower rated air volume (m3/min) Capacity/model name (equivalent horsepower) Compressor motor output (kW) Electrical characteristics Operating current Cooling (A) Electrical characteristics Operating current Heating (A) Electrical characteristics Power consumption Cooling (kW) Electrical characteristics Power consumption Heating (kW) Electrical characteristics Power factor Cooling (%) Electrical characteristics Power factor Heating (%) Exterior color (Munsell symbol) Main piping size (cooling/heating switching system) Liquid (mm) Main piping size High and low pressure gas (mm) Main piping size Low pressure gas (mm) Maximum heating low temperature capacity (kW) Operating noise (dB (A) ) Outer diameter dimensions W×D×H (mm) Power specifications Product mass (kg) Rated cooling standard capacity (kW) Rated heating standard capacity (kW)
Flex multi simultaneous heating and cooling type (TGX/TSX/TZX series)-Part Number-RAS-AP140TGX

RAS-AP140TGX

Available upon quote 0.19 154 140 type (5) 2.68 10.2 9.7 3.19 3.02 90 90 Natural gray (1.0Y 8.5/0.5) Φ9.52 Φ12.7 Φ15.88 13 75 950×765×1,755 Three phase 200V 197 14 16
Flex multi simultaneous heating and cooling type (TGX/TSX/TZX series)-Part Number-RAS-AP160TGX

RAS-AP160TGX

Available upon quote 0.26 175 160 type (6) 3.11 12 11.5 3.74 3.59 90 90 Natural gray (1.0Y 8.5/0.5) Φ9.52 Φ15.88 Φ19.05 15 79 950×765×1,755 Three phase 200V 197 16 18
Flex multi simultaneous heating and cooling type (TGX/TSX/TZX series)-Part Number-RAS-AP224TGX

RAS-AP224TGX

Available upon quote 0.16×2 185 224 type (8) 4.86 17.9 17.3 5.69 5.52 92 92 Natural gray (1.0Y 8.5/0.5) Φ9.52 Φ15.88 Φ19.05 22.8 78 1,210×765×1,755 Three phase 200V 262 22.4 Twenty five
Flex multi simultaneous heating and cooling type (TGX/TSX/TZX series)-Part Number-RAS-AP280TGX

RAS-AP280TGX

Available upon quote 0.24×2 219 280 type (10) 6.92 25.4 24.3 8.08 7.73 92 92 Natural gray (1.0Y 8.5/0.5) Φ9.52 Φ19.05 Φ22.2 26.8 81 1,210×765×1,755 Three phase 200V 262 28 31.5
Flex multi simultaneous heating and cooling type (TGX/TSX/TZX series)-Part Number-RAS-AP335TGX

RAS-AP335TGX

Available upon quote 0.24×2 219 335 type (12) 8.35 30.2 27.8 9.64 8.86 92 92 Natural gray (1.0Y 8.5/0.5) Φ12.7 Φ22.2 Φ25.4 30 83 1,210×765×1,755 Three phase 200V 267 33.5 37.5
Flex multi simultaneous heating and cooling type (TGX/TSX/TZX series)-Part Number-RAS-AP400TGX

RAS-AP400TGX

Available upon quote 0.35×2 256 400 type (14) 10.6 38.6 36.4 12.3 11.6 92 92 Natural gray (1.0Y 8.5/0.5) Φ12.7 Φ22.2 Φ25.4 35.8 86 1,210×765×1,755 Three phase 200V 267 40 45
Flex multi simultaneous heating and cooling type (TGX/TSX/TZX series)-Part Number-RAS-AP450TGX

RAS-AP450TGX

Available upon quote 0.46×2 346 450 type (16) 5.16×2 38.9 37 12.4 11.8 92 92 Natural gray (1.0Y 8.5/0.5) Φ12.7 Φ22.2 Φ28.58 45.6 84 1,600×765×1,755 Three phase 200V 360 45 50
Flex multi simultaneous heating and cooling type (TGX/TSX/TZX series)-Part Number-RAS-AP500TGX

RAS-AP500TGX

Available upon quote 0.52×2 362 500 type (18) 6.04×2 44.6 45.2 14.2 14.4 92 92 Natural gray (1.0Y 8.5/0.5) Φ15.88 Φ22.2 Φ28.58 48 86 1,600×765×1,755 Three phase 200V 360 50 56
Flex multi simultaneous heating and cooling type (TGX/TSX/TZX series)-Part Number-RAS-AP560TGX

RAS-AP560TGX

Available upon quote (0.24×2) ×2 219×2 560 type (20) (6.92) ×2 50.8 48.6 16.2 15.5 92 92 Natural gray (1.0Y 8.5/0.5) Φ15.88 Φ22.2 Φ28.58 53.6 84 2,440×765×1,755 Three phase 200V 262×2 56 63
Flex multi simultaneous heating and cooling type (TGX/TSX/TZX series)-Part Number-RAS-AP615TGX

RAS-AP615TGX

Available upon quote (0.24×2) + (0.24×2) 219+219 Type 615 (22) (8.35) + (6.92) 55.9 52.1 17.8 16.6 92 92 Natural gray (1.0Y 8.5/0.5) Φ15.88 Φ25.4 Φ28.58 56.8 85 2,440×765×1,755 Three phase 200V 267+262 61.5 69

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Kyushu Kiden Co., Ltd.


View more products of Kyushu Kiden Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree