Product
Air conditioner for stores and offices Indoor unit Achieves distributed air conditioning with full-scale ducts and highly interior-friendly air conditioning with ample external static pressure even with a thin body.Handling Company
Kyushu Kiden Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Blower output (kW) | Capacity (kW) Maximum heating low temperature | Capacity (kW) Rated cooling standard | Capacity (kW) Rated heating standard | Drain piping | External wiring Indoor/outdoor wiring (pcs) | External wiring Minimum wire thickness (mm^2) | External wiring breaker capacity (A) | Indoor air flow (m^3/min) (H-sudden-strong-weak) | Mass (kg) | Motor compressor output (kW) | Operating current (A) Max. | Operating current (A) Rating standard | Operating noise (dB (A)) Indoor | Operating noise (dB (A)) Outdoor cooling/heating | Outer diameter dimensions (mm) (width x depth x height) | Power (V) | Power consumption (kW) Maximum heating low temperature | Power consumption (kW) Rated cooling standard | Power consumption (kW) Rated heating standard | Power factor (%) Rating standard | Refrigerant piping Liquid pipe/Gas pipe φ (mm) | Refrigerant piping maximum height difference (m) | Refrigerant piping maximum length (m) | Sensible heat ratio during rated cooling | The refrigerant type ( ) is the filling amount (kg) | Type | Year-round energy consumption efficiency |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RPI-GP45RGHJ7 |
Available upon quote |
Indoor unit: 0.157×1 Outdoor unit: 0.05×1 |
4.5 | 4.0 (1.1~4.5) | 4.5 (1.2~5.9) | VP25 | 2+2 |
Indoor: 2.0 Outdoor: 3.5 |
Indoor: - Outdoor: 15 |
13-11.5-10-8.5 |
Indoor unit: 29 Outdoor unit: 41 |
0.65 | 13.7 |
Cooling: 5.0 Heating: 5.8 |
56-53-51-48 | 65/67 |
Indoor unit: 700 x 800 x 300 Outdoor unit: 799 (+99) ×300×629 |
Single phase 200 50Hz/60Hz |
1.7 | 0.94 | 1.09 |
Cooling: 94 Heating: 94 |
6.35/12.7 (indoor unit/outdoor unit) | 30 | 50 | 0.76 | R32 (1.3) | Cooling/heating single | 5.4 | |
RPI-GP45RGH7 |
Available upon quote |
Indoor unit: 0.157×1 Outdoor unit: 0.05×1 |
4.5 | 4.0 (1.1~4.5) | 4.5 (1.2~5.9) | VP25 | 2+2 |
Indoor: 2.0 Outdoor: 2.0 |
Indoor: - Outdoor: 15 |
13-11.5-10-8.5 |
Indoor unit: 29 Outdoor unit: 39 |
0.65 | 10.2 |
Cooling: 3.1 Heating: 3.5 |
56-53-51-48 | 65/67 |
Indoor unit: 700 x 800 x 300 Outdoor unit: 799 (+99) ×300×629 |
Three phase 200 50Hz/60Hz |
1.7 | 0.94 | 1.09 |
Cooling: 88 Heating: 90 |
6.35/12.7 (indoor unit/outdoor unit) | 30 | 50 | 0.76 | R32 (1.3) | Cooling/heating single | 5.4 | |
RPI-GP50RGHJ7 |
Available upon quote |
Indoor unit: 0.157×1 Outdoor unit: 0.05×1 |
4.8 | 4.5 (1.4~5.0) | 5.0 (1.3~6.3) | VP25 | 2+2 |
Indoor: 2.0 Outdoor: 3.5 |
Indoor: - Outdoor: 15 |
14.5-13-11-9.5 |
Indoor unit: 29 Outdoor unit: 41 |
0.75 | 13.7 |
Cooling: 6.1 Heating: 6.7 |
59-56-53-50 | 65/67 |
Indoor unit: 700 x 800 x 300 Outdoor unit: 799 (+99) ×300×629 |
Single phase 200 50Hz/60Hz |
1.87 | 1.14 | 1.28 |
Cooling: 93 Heating: 96 |
6.35/12.7 (indoor unit/outdoor unit) | 30 | 50 | 0.74 | R32 (1.3) | Cooling/heating single | 5.3 | |
RPI-GP50RGH7 |
Available upon quote |
Indoor unit: 0.157×1 Outdoor unit: 0.05×1 |
4.8 | 4.5 (1.4~5.0) | 5.0 (1.3~6.3) | VP25 | 2+2 |
Indoor: 2.0 Outdoor: 2.0 |
Indoor: - Outdoor: 15 |
14.5-13-11-9.5 |
Indoor unit: 29 Outdoor unit: 39 |
0.75 | 10.2 |
Cooling: 3.6 Heating: 4.0 |
59-56-53-50 | 65/67 |
Indoor unit: 700 x 800 x 300 Outdoor unit: 799 (+99) ×300×629 |
Three phase 200 50Hz/60Hz |
1.87 | 1.14 | 1.28 |
Cooling: 91 Heating: 92 |
6.35/12.7 (indoor unit/outdoor unit) | 30 | 50 | 0.74 | R32 (1.3) | Cooling/heating single | 5.4 | |
RPI-GP56RGHJ7 |
Available upon quote |
Indoor unit: 0.157×1 Outdoor unit: 0.05×1 |
5.6 | 5.0 (1.5~5.6) | 5.6 (1.4~7.1) | VP25 | 2+2 |
Indoor: 2.0 Outdoor: 3.5 |
Indoor: - Outdoor: 15 |
14.5-13-11-9.5 |
Indoor unit: 29 Outdoor unit: 41 |
0.9 | 13.7 |
Cooling: 7.2 Heating: 8.0 |
59-56-53-50 | 65/67 |
Indoor unit: 700 x 800 x 300 Outdoor unit: 799 (+99) ×300×629 |
Single phase 200 50Hz/60Hz |
2.25 | 1.36 | 1.55 |
Cooling: 94 Heating: 97 |
6.35/12.7 (indoor unit/outdoor unit) | 30 | 50 | 0.73 | R32 (1.3) | Cooling/heating single | 5.4 | |
RPI-GP56RGH7 |
Available upon quote |
Indoor unit: 0.157×1 Outdoor unit: 0.05×1 |
5.6 | 5.0 (1.5~5.6) | 5.6 (1.4~7.1) | VP25 | 2+2 |
Indoor: 2.0 Outdoor: 2.0 |
Indoor: - Outdoor: 15 |
14.5-13-11-9.5 |
Indoor unit: 29 Outdoor unit: 39 |
0.9 | 10.2 |
Cooling: 4.3 Heating: 4.7 |
59-56-53-50 | 65/67 |
Indoor unit: 700 x 800 x 300 Outdoor unit: 799 (+99) ×300×629 |
Three phase 200 50Hz/60Hz |
2.25 | 1.36 | 1.55 |
Cooling: 91 Heating: 95 |
6.35/12.7 (indoor unit/outdoor unit) | 30 | 50 | 0.73 | R32 (1.3) | Cooling/heating single | 5.4 | |
RPI-GP63RGHJ7 |
Available upon quote |
Indoor unit: 0.190×1 Outdoor unit: 0.05×1 |
6.2 | 5.6 (1.5~6.3) | 6.3 (1.6~8.0) | VP25 | 2+2 |
Indoor: 2.0 Outdoor: 3.5 |
Indoor: - Outdoor: 15 |
17-15-13-11 |
Indoor unit: 38 Outdoor unit: 41 |
1 | 13.5 |
Cooling: 7.8 Heating: 8.9 |
54-52-50-48 | 65/67 |
Indoor unit: 1,050 x 800 x 300 Outdoor unit: 799 (+99) ×300×629 |
Single phase 200 50Hz/60Hz |
2.85 | 1.49 | 1.71 |
Cooling: 96 Heating: 96 |
6.35/12.7 (indoor unit/outdoor unit) | 30 | 50 | 0.74 | R32 (1.3) | Cooling/heating single | 5.4 | |
RPI-GP63RGH7 |
Available upon quote |
Indoor unit: 0.190×1 Outdoor unit: 0.05×1 |
6.2 | 5.6 (1.5~6.3) | 6.3 (1.6~8.0) | VP25 | 2+2 |
Indoor: 2.0 Outdoor: 2.0 |
Indoor: - Outdoor: 15 |
17-15-13-11 |
Indoor unit: 38 Outdoor unit: 39 |
1 | 10 |
Cooling: 4.5 Heating: 5.3 |
54-52-50-48 | 65/67 |
Indoor unit: 1,050 x 800 x 300 Outdoor unit: 799 (+99) ×300×629 |
Three phase 200 50Hz/60Hz |
2.85 | 1.49 | 1.71 |
Cooling: 96 Heating: 93 |
6.35/12.7 (indoor unit/outdoor unit) | 30 | 50 | 0.74 | R32 (1.3) | Cooling/heating single | 5.4 | |
RPI-GP80RGHJ7 |
Available upon quote |
Indoor unit: 0.190×1 Outdoor unit: 0.05×1 |
7.8 | 7.1 (1.8~8.0) | 8.0 (2.0~10.6) | VP25 | 2+2 |
Indoor: 2.0 Outdoor: 3.5 |
Indoor: - Outdoor: 20 |
20-17.5-15.5-13 |
Indoor unit: 38 Outdoor unit: 45 |
1.35 | 17.7 |
Cooling: 10.6 Heating: 11.6 |
57-54-51-49 | 67/68 |
Indoor unit: 1,050 x 800 x 300 Outdoor unit: 859 (+100) ×319×709 |
Single phase 200 50Hz/60Hz |
3.67 | 2.03 | 2.23 |
Cooling: 96 Heating: 96 |
9.52/15.88 (indoor unit/outdoor unit) | 30 | 50 | 0.72 | R32 (2.0) | Cooling/heating single | 5.4 | |
RPI-GP80RGH7 |
Available upon quote |
Indoor unit: 0.190×1 Outdoor unit: 0.05×1 |
7.8 | 7.1 (1.8~8.0) | 8.0 (2.0~10.6) | VP25 | 2+2 |
Indoor: 2.0 Outdoor: 2.0 |
Indoor: - Outdoor: 15 |
20-17.5-15.5-13 |
Indoor unit: 38 Outdoor unit: 43 |
1.35 | 11.7 |
Cooling: 6.2 Heating: 6.8 |
57-54-51-49 | 67/68 |
Indoor unit: 1,050 x 800 x 300 Outdoor unit: 859 (+100) ×319×709 |
Three phase 200 50Hz/60Hz |
3.67 | 2.03 | 2.23 |
Cooling: 95 Heating: 95 |
9.52/15.88 (indoor unit/outdoor unit) | 30 | 50 | 0.72 | R32 (2.0) | Cooling/heating single | 5.4 |
Click on the part number for more information about each product