All Categories
History
Product
Air conditioner for stores and offices Indoor unit Achieves distributed air conditioning with full-scale ducts and highly interior-friendly air conditioning with ample external static pressure even with a thin body.Handling Company
Kyushu Kiden Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power (V) | Motor compressor output (kW) | Operating noise (dB (A)) Outdoor cooling/heating | Operating noise (dB (A)) Indoor | Operating current (A) Max. | Operating current (A) Rating standard | Year-round energy consumption efficiency | Blower output (kW) | Mass (kg) | Capacity (kW) Maximum heating low temperature | Capacity (kW) Rated heating standard | Capacity (kW) Rated cooling standard | Power consumption (kW) Maximum heating low temperature | Power consumption (kW) Rated heating standard | Power consumption (kW) Rated cooling standard | External wiring Minimum wire thickness (mm^2) | External wiring Indoor/outdoor wiring (pcs) | External wiring breaker capacity (A) | Indoor air flow (m^3/min) (H-sudden-strong-weak) | Sensible heat ratio during rated cooling | Outer diameter dimensions (mm) (width x depth x height) | Power factor (%) Rating standard | Refrigerant piping Liquid pipe/Gas pipe φ (mm) | Refrigerant piping maximum height difference (m) | Refrigerant piping maximum length (m) | The refrigerant type ( ) is the filling amount (kg) | Drain piping | Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RPI-GP45RGHJ7 |
Available upon quote |
Single phase 200 |
0.65 |
65/67 |
56-53-51-48 |
13.7 |
Cooling: 5.0 |
5.4 |
Indoor unit: 0.157×1 |
Indoor unit: 29 |
4.5 |
4.5 (1.2~5.9) |
4.0 (1.1~4.5) |
1.7 |
1.09 |
0.94 |
Indoor: 2.0 |
2+2 |
Indoor: - |
13-11.5-10-8.5 |
0.76 |
Indoor unit: 700 x 800 x 300 |
Cooling: 94 |
6.35/12.7 (indoor unit/outdoor unit) |
30 |
50 |
R32 (1.3) |
VP25 |
Cooling/heating single |
|
RPI-GP45RGH7 |
Available upon quote |
Three phase 200 |
0.65 |
65/67 |
56-53-51-48 |
10.2 |
Cooling: 3.1 |
5.4 |
Indoor unit: 0.157×1 |
Indoor unit: 29 |
4.5 |
4.5 (1.2~5.9) |
4.0 (1.1~4.5) |
1.7 |
1.09 |
0.94 |
Indoor: 2.0 |
2+2 |
Indoor: - |
13-11.5-10-8.5 |
0.76 |
Indoor unit: 700 x 800 x 300 |
Cooling: 88 |
6.35/12.7 (indoor unit/outdoor unit) |
30 |
50 |
R32 (1.3) |
VP25 |
Cooling/heating single |
|
RPI-GP50RGHJ7 |
Available upon quote |
Single phase 200 |
0.75 |
65/67 |
59-56-53-50 |
13.7 |
Cooling: 6.1 |
5.3 |
Indoor unit: 0.157×1 |
Indoor unit: 29 |
4.8 |
5.0 (1.3~6.3) |
4.5 (1.4~5.0) |
1.87 |
1.28 |
1.14 |
Indoor: 2.0 |
2+2 |
Indoor: - |
14.5-13-11-9.5 |
0.74 |
Indoor unit: 700 x 800 x 300 |
Cooling: 93 |
6.35/12.7 (indoor unit/outdoor unit) |
30 |
50 |
R32 (1.3) |
VP25 |
Cooling/heating single |
|
RPI-GP50RGH7 |
Available upon quote |
Three phase 200 |
0.75 |
65/67 |
59-56-53-50 |
10.2 |
Cooling: 3.6 |
5.4 |
Indoor unit: 0.157×1 |
Indoor unit: 29 |
4.8 |
5.0 (1.3~6.3) |
4.5 (1.4~5.0) |
1.87 |
1.28 |
1.14 |
Indoor: 2.0 |
2+2 |
Indoor: - |
14.5-13-11-9.5 |
0.74 |
Indoor unit: 700 x 800 x 300 |
Cooling: 91 |
6.35/12.7 (indoor unit/outdoor unit) |
30 |
50 |
R32 (1.3) |
VP25 |
Cooling/heating single |
|
RPI-GP56RGHJ7 |
Available upon quote |
Single phase 200 |
0.9 |
65/67 |
59-56-53-50 |
13.7 |
Cooling: 7.2 |
5.4 |
Indoor unit: 0.157×1 |
Indoor unit: 29 |
5.6 |
5.6 (1.4~7.1) |
5.0 (1.5~5.6) |
2.25 |
1.55 |
1.36 |
Indoor: 2.0 |
2+2 |
Indoor: - |
14.5-13-11-9.5 |
0.73 |
Indoor unit: 700 x 800 x 300 |
Cooling: 94 |
6.35/12.7 (indoor unit/outdoor unit) |
30 |
50 |
R32 (1.3) |
VP25 |
Cooling/heating single |
|
RPI-GP56RGH7 |
Available upon quote |
Three phase 200 |
0.9 |
65/67 |
59-56-53-50 |
10.2 |
Cooling: 4.3 |
5.4 |
Indoor unit: 0.157×1 |
Indoor unit: 29 |
5.6 |
5.6 (1.4~7.1) |
5.0 (1.5~5.6) |
2.25 |
1.55 |
1.36 |
Indoor: 2.0 |
2+2 |
Indoor: - |
14.5-13-11-9.5 |
0.73 |
Indoor unit: 700 x 800 x 300 |
Cooling: 91 |
6.35/12.7 (indoor unit/outdoor unit) |
30 |
50 |
R32 (1.3) |
VP25 |
Cooling/heating single |
|
RPI-GP63RGHJ7 |
Available upon quote |
Single phase 200 |
1 |
65/67 |
54-52-50-48 |
13.5 |
Cooling: 7.8 |
5.4 |
Indoor unit: 0.190×1 |
Indoor unit: 38 |
6.2 |
6.3 (1.6~8.0) |
5.6 (1.5~6.3) |
2.85 |
1.71 |
1.49 |
Indoor: 2.0 |
2+2 |
Indoor: - |
17-15-13-11 |
0.74 |
Indoor unit: 1,050 x 800 x 300 |
Cooling: 96 |
6.35/12.7 (indoor unit/outdoor unit) |
30 |
50 |
R32 (1.3) |
VP25 |
Cooling/heating single |
|
RPI-GP63RGH7 |
Available upon quote |
Three phase 200 |
1 |
65/67 |
54-52-50-48 |
10 |
Cooling: 4.5 |
5.4 |
Indoor unit: 0.190×1 |
Indoor unit: 38 |
6.2 |
6.3 (1.6~8.0) |
5.6 (1.5~6.3) |
2.85 |
1.71 |
1.49 |
Indoor: 2.0 |
2+2 |
Indoor: - |
17-15-13-11 |
0.74 |
Indoor unit: 1,050 x 800 x 300 |
Cooling: 96 |
6.35/12.7 (indoor unit/outdoor unit) |
30 |
50 |
R32 (1.3) |
VP25 |
Cooling/heating single |
|
RPI-GP80RGHJ7 |
Available upon quote |
Single phase 200 |
1.35 |
67/68 |
57-54-51-49 |
17.7 |
Cooling: 10.6 |
5.4 |
Indoor unit: 0.190×1 |
Indoor unit: 38 |
7.8 |
8.0 (2.0~10.6) |
7.1 (1.8~8.0) |
3.67 |
2.23 |
2.03 |
Indoor: 2.0 |
2+2 |
Indoor: - |
20-17.5-15.5-13 |
0.72 |
Indoor unit: 1,050 x 800 x 300 |
Cooling: 96 |
9.52/15.88 (indoor unit/outdoor unit) |
30 |
50 |
R32 (2.0) |
VP25 |
Cooling/heating single |
|
RPI-GP80RGH7 |
Available upon quote |
Three phase 200 |
1.35 |
67/68 |
57-54-51-49 |
11.7 |
Cooling: 6.2 |
5.4 |
Indoor unit: 0.190×1 |
Indoor unit: 38 |
7.8 |
8.0 (2.0~10.6) |
7.1 (1.8~8.0) |
3.67 |
2.23 |
2.03 |
Indoor: 2.0 |
2+2 |
Indoor: - |
20-17.5-15.5-13 |
0.72 |
Indoor unit: 1,050 x 800 x 300 |
Cooling: 95 |
9.52/15.88 (indoor unit/outdoor unit) |
30 |
50 |
R32 (2.0) |
VP25 |
Cooling/heating single |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
38.0hrs
Company Review
5.0