Air conditioner for stores and offices Indoor unit Increase space comfort with individual louver setting function Tenkase 4 directions-RCI-GP40RGHJ7
Air conditioner for stores and offices Indoor unit Increase space comfort with individual louver setting function Tenkase 4 directions-Kyushu Kiden Co., Ltd.

Air conditioner for stores and offices Indoor unit Increase space comfort with individual louver setting function Tenkase 4 directions
Kyushu Kiden Co., Ltd.


About This Product

■Comfortable performance Wind blows at 15 degrees, making it difficult for the wind to hit people ■Reduces dirt on the ceiling surface The design prevents high-velocity air from hitting the surface of the decorative panel or the ceiling near the unit, reducing dirt on each. ■Designed to achieve 15° blowing By designing so that both sides of the louver are covered with airflow, we have taken into consideration the controllability of the blowout angle. ■Control airflow with individual louver settings in 4 directions Equipped with an individual louver setting function that allows you to adjust the angle of the four louvers individually. For example, you can set the airflow according to your environment and needs, such as sideways blowing in the direction you want to reduce wind blowing, or swinging in the direction you want the wind to blow. (Only when combined with multi-function design remote control, multi-function remote control, and compact remote control) ■“Identification mark” makes it easy to set individual louvers The angle and movement of each louver can be easily adjusted using the multi-function (design) remote control or compact remote control. ■If you use a decorative panel with a human/radiant temperature sensor, it can detect the amount of human activity and the radiant temperature of floors, tables, etc., and air condition efficiently. We have a lineup of decorative panels equipped with 4 human sensors and 1 radiant temperature sensor. A human sensor detects the amount of human activity in each of the four areas of the air outlet, and a radiant temperature sensor detects the radiant temperature of floors, tables, etc. in the entire area, allowing comfortable air conditioning control according to indoor conditions. I made it possible. *A multi-function (design) remote control is required for sensor control. ■High design adaptability, including support for “high ceilings” and “narrow ceiling spaces” The height of the 28-71 inch unit is 248mm. It fits neatly even in places where there is no ceiling space. In addition, if you use a panel with an elevating grill, it can accommodate high ceilings up to 5.0 m. (140 type class) ■Compatible with high ceilings up to 5.0m with "H sudden wind tap" + "elevating grill" It can accommodate high ceilings up to 4.2m using the H-sudden tap, and up to 5.0m using a panel with an elevating grill (140-inch class). We respond to a wide range of needs, including suburban stores and showrooms. There are other model numbers as well.

  • Product

    Air conditioner for stores and offices Indoor unit Increase space comfort with individual louver setting function Tenkase 4 directions

Share this product


370+ people viewing

Last viewed: 1 hour ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Air conditioner for stores and offices Indoor unit Increase space comfort with individual louver setting function Tenkase 4 directions

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Blower output (kW) Capacity (kW) Maximum heating low temperature Capacity (kW) Rated cooling standard Capacity (kW) Rated heating standard Drain piping External wiring Indoor/outdoor wiring (pcs) External wiring Minimum wire thickness (mm^2) External wiring breaker capacity (A) Indoor air flow (m^3/min) (H-sudden-strong-weak) Mass (kg) Motor compressor output (kW) Operating current (A) Max. Operating current (A) Rating standard Operating noise (dB (A)) Indoor Operating noise (dB (A)) Outdoor cooling/heating Outer diameter dimensions (mm) (width x depth x height) Power (V) Power consumption (kW) Maximum heating low temperature Power consumption (kW) Rated cooling standard Power consumption (kW) Rated heating standard Power factor (%) Rating standard Refrigerant piping Liquid pipe/Gas pipe φ (mm) Refrigerant piping maximum height difference (m) Refrigerant piping maximum length (m) Sensible heat ratio during rated cooling The refrigerant type ( ) is the filling amount (kg) Type Year-round energy consumption efficiency
Air conditioner for stores and offices Indoor unit Increase space comfort with individual louver setting function Tenkase 4 directions-Part Number-RCI-GP40RGHJ7

RCI-GP40RGHJ7

Available upon quote Indoor unit: 0.057×1
Outdoor unit: 0.05×1
5.2 3.6 (1.1~4.0) 4.0 (1.0~5.4) VP25 2+2 Indoor: 2.0
Outdoor: 3.5
Indoor: -
Outdoor: 15
20-16-14-11 Indoor unit: 21 (+6.5)
Outdoor unit: 41
0.55 12.9 Cooling: 3.5
Heating: 4.0
51-48-46-44 (H-sudden-sudden-strong-weak) 65/67 Indoor unit: 950×950×288 (248)
Outdoor unit: 799 (+99) ×300×629
Single phase 200
50Hz/60Hz
1.59 0.631 0.712 Cooling: 89
Heating: 90
6.35/12.7 (indoor unit/outdoor unit) 30 50 0.88 R32 (1.3) Cooling/heating single 7.8
Air conditioner for stores and offices Indoor unit Increase space comfort with individual louver setting function Tenkase 4 directions-Part Number-RCI-GP40RGH7

RCI-GP40RGH7

Available upon quote Indoor unit: 0.057×1
Outdoor unit: 0.05×1
5.2 3.6 (1.1~4.0) 4.0 (1.0~5.4) VP25 2+2 Indoor: 2.0
Outdoor: 2.0
Indoor: -
Outdoor: 15
20-16-14-11 Indoor unit: 21 (+6.5)
Outdoor unit: 39
0.55 9.4 Cooling: 2.1
Heating: 2.3
51-48-46-44 (H-sudden-sudden-strong-weak) 65/67 Indoor unit: 950×950×288 (248)
Outdoor unit: 799 (+99) ×300×629
Three phase 200
50Hz/60Hz
1.59 0.631 0.712 Cooling: 87
Heating: 98
6.35/12.7 (indoor unit/outdoor unit) 30 50 0.88 R32 (1.3) Cooling/heating single 7.8
Air conditioner for stores and offices Indoor unit Increase space comfort with individual louver setting function Tenkase 4 directions-Part Number-RCI-GP45RGHJ7

RCI-GP45RGHJ7

Available upon quote Indoor unit: 0.057×1
Outdoor unit: 0.05×1
5.4 4.0 (1.1~4.5) 4.5 (1.2~5.9) VP25 2+2 Indoor: 2.0
Outdoor: 3.5
Indoor: -
Outdoor: 15
20-16-14-11 Indoor unit: 21 (+6.5)
Outdoor unit: 41
0.65 12.9 Cooling: 4.0
Heating: 4.5
51-48-46-44 (H-sudden-sudden-strong-weak) 65/67 Indoor unit: 950×950×288 (248)
Outdoor unit: 799 (+99) ×300×629
Single phase 200
50Hz/60Hz
1.77 0.75 0.847 Cooling: 93
Heating: 94
6.35/12.7 (indoor unit/outdoor unit) 30 50 0.89 R32 (1.3) Cooling/heating single 7.8
Air conditioner for stores and offices Indoor unit Increase space comfort with individual louver setting function Tenkase 4 directions-Part Number-RCI-GP45RGH7

RCI-GP45RGH7

Available upon quote Indoor unit: 0.057×1
Outdoor unit: 0.05×1
5.4 4.0 (1.1~4.5) 4.5 (1.2~5.9) VP25 2+2 Indoor: 2.0
Outdoor: 2.0
Indoor: -
Outdoor: 15
20-16-14-11 Indoor unit: 21 (+6.5)
Outdoor unit: 39
0.65 9.4 Cooling: 2.4
Heating: 2.7
51-48-46-44 (H-sudden-sudden-strong-weak) 65/67 Indoor unit: 950×950×288 (248)
Outdoor unit: 799 (+99) ×300×629
Three phase 200
50Hz/60Hz
1.77 0.75 0.847 Cooling: 91
Heating: 92
6.35/12.7 (indoor unit/outdoor unit) 30 50 0.89 R32 (1.3) Cooling/heating single 7.8
Air conditioner for stores and offices Indoor unit Increase space comfort with individual louver setting function Tenkase 4 directions-Part Number-RCI-GP50RGHJ7

RCI-GP50RGHJ7

Available upon quote Indoor unit: 0.057×1
Outdoor unit: 0.05×1
5.6 4.5 (1.3~5.0) 5.0 (1.3~6.3) VP25 2+2 Indoor: 2.0
Outdoor: 3.5
Indoor: -
Outdoor: 15
22-17-14-12 Indoor unit: 21 (+6.5)
Outdoor unit: 41
0.75 12.9 Cooling: 4.6
Heating: 5.0
52-48-46-45 (H-sudden-strong-weak) 65/67 Indoor unit: 950×950×288 (248)
Outdoor unit: 799 (+99) ×300×629
Single phase 200
50Hz/60Hz
1.87 0.863 0.95 Cooling: 94
Heating: 95
6.35/12.7 (indoor unit/outdoor unit) 30 50 0.92 R32 (1.3) Cooling/heating single 7.7
Air conditioner for stores and offices Indoor unit Increase space comfort with individual louver setting function Tenkase 4 directions-Part Number-RCI-GP50RGH7

RCI-GP50RGH7

Available upon quote Indoor unit: 0.057×1
Outdoor unit: 0.05×1
5.6 4.5 (1.3~5.0) 5.0 (1.3~6.3) VP25 2+2 Indoor: 2.0
Outdoor: 2.0
Indoor: -
Outdoor: 15
22-17-14-12 Indoor unit: 21 (+6.5)
Outdoor unit: 39
0.75 9.4 Cooling: 2.7
Heating: 2.9
52-48-46-45 (H-sudden-strong-weak) 65/67 Indoor unit: 950×950×288 (248)
Outdoor unit: 799 (+99) ×300×629
Three phase 200
50Hz/60Hz
1.87 0.863 0.95 Cooling: 92
Heating: 93
6.35/12.7 (indoor unit/outdoor unit) 30 50 0.92 R32 (1.3) Cooling/heating single 7.7
Air conditioner for stores and offices Indoor unit Increase space comfort with individual louver setting function Tenkase 4 directions-Part Number-RCI-GP56RGHJ7

RCI-GP56RGHJ7

Available upon quote Indoor unit: 0.057×1
Outdoor unit: 0.05×1
5.9 5.0 (1.5~5.6) 5.6 (1.4~7.1) VP25 2+2 Indoor: 2.0
Outdoor: 3.5
Indoor: -
Outdoor: 15
22-17-14-12 Indoor unit: 21 (+6.5)
Outdoor unit: 41
0.9 12.9 Cooling: 5.4
Heating: 5.8
52-48-46-45 (H-sudden-strong-weak) 65/67 Indoor unit: 950×950×288 (248)
Outdoor unit: 799 (+99) ×300×629
Single phase 200
50Hz/60Hz
1.96 1.03 1.12 Cooling: 95
Heating: 96
6.35/12.7 (indoor unit/outdoor unit) 30 50 0.91 R32 (1.3) Cooling/heating single 7.5
Air conditioner for stores and offices Indoor unit Increase space comfort with individual louver setting function Tenkase 4 directions-Part Number-RCI-GP56RGH7

RCI-GP56RGH7

Available upon quote Indoor unit: 0.057×1
Outdoor unit: 0.05×1
5.9 5.0 (1.5~5.6) 5.6 (1.4~7.1) VP25 2+2 Indoor: 2.0
Outdoor: 2.0
Indoor: -
Outdoor: 15
22-17-14-12 Indoor unit: 21 (+6.5)
Outdoor unit: 39
0.9 9.4 Cooling: 3.2
Heating: 3.4
52-48-46-45 (H-sudden-strong-weak) 65/67 Indoor unit: 950×950×288 (248)
Outdoor unit: 799 (+99) ×300×629
Three phase 200
50Hz/60Hz
1.96 1.03 1.12 Cooling: 93
Heating: 94
6.35/12.7 (indoor unit/outdoor unit) 30 50 0.91 R32 (1.3) Cooling/heating single 7.5
Air conditioner for stores and offices Indoor unit Increase space comfort with individual louver setting function Tenkase 4 directions-Part Number-RCI-GP63RGHJ7

RCI-GP63RGHJ7

Available upon quote Indoor unit: 0.057×1
Outdoor unit: 0.05×1
6.2 5.6 (1.5~6.3) 6.3 (1.6~8.0) VP25 2+2 Indoor: 2.0
Outdoor: 3.5
Indoor: -
Outdoor: 15
26-20-17-13 Indoor unit: 22 (+6.5)
Outdoor unit: 41
1 13.1 Cooling: 6.2
Heating: 6.6
56-52-49-47 (H-sudden-strong-weak) 65/67 Indoor unit: 950×950×288 (248)
Outdoor unit: 799 (+99) ×300×629
Single phase 200
50Hz/60Hz
2.2 1.19 1.25 Cooling: 96
Heating: 95
6.35/12.7 (indoor unit/outdoor unit) 30 50 0.94 R32 (1.3) Cooling/heating single 7.4
Air conditioner for stores and offices Indoor unit Increase space comfort with individual louver setting function Tenkase 4 directions-Part Number-RCI-GP63RGH7

RCI-GP63RGH7

Available upon quote Indoor unit: 0.057×1
Outdoor unit: 0.05×1
6.2 5.6 (1.5~6.3) 6.3 (1.6~8.0) VP25 2+2 Indoor: 2.0
Outdoor: 2.0
Indoor: -
Outdoor: 15
26-20-17-13 Indoor unit: 22 (+6.5)
Outdoor unit: 39
1 9.6 Cooling: 3.7
Heating: 3.9
56-52-49-47 (H-sudden-strong-weak) 65/67 Indoor unit: 950×950×288 (248)
Outdoor unit: 799 (+99) ×300×629
Three phase 200
50Hz/60Hz
2.2 1.19 1.25 Cooling: 94
Heating: 93
6.35/12.7 (indoor unit/outdoor unit) 30 50 0.94 R32 (1.3) Cooling/heating single 7.4

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Kyushu Kiden Co., Ltd.


View more products of Kyushu Kiden Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree