Hoist Standard equipped with load swing suppression function SuperV series (Type 4)-Power supply voltage 200V class, rated load 1t
Hoist Standard equipped with load swing suppression function SuperV series (Type 4)-Kyushu Kiden Co., Ltd.

Hoist Standard equipped with load swing suppression function SuperV series (Type 4)
Kyushu Kiden Co., Ltd.


About This Product

■Variable speed pushbutton has 2-stage motion The first stage is a low speed setting, and the second stage is a high speed setting. Both low and high speeds can be set independently to any desired speed. ■Less vibration of the suspended load Cushion start/stop reduces the shock when starting and stopping, reducing the vibration of the lifted load and the shock to buildings and crane girders. ■Smooth running reduces load swing By smoothing acceleration and deceleration, swinging of the suspended load can be reduced. ■Mitigating shock to mechanical parts Since the brake is applied when the motor rotation is low, there is less wear on the lining, and there is less impact on mechanical parts such as wire ropes, sheaves, couplings, and gears, resulting in a longer life. ■Equipped with load swing suppression function as standard Inverter drive reduces swinging of the lifted load, but when transporting the lifted load, due to inertia, the load swings when stopped. Depending on how the lifted load swings, the operator can perform follow-up operations, or so-called follow-up notch operations, to suppress the occurrence of load swing, but this operation is difficult for inexperienced operators. Therefore, we have installed a ``load swing suppression function'' as standard, which can automatically suppress the occurrence of load swing by using a function equivalent to a follow-up notch operation, even if you do not perform a follow-up notch operation. This function allows even inexperienced operators to operate the machine while suppressing load swing, allowing the lifted load to be quickly transported to the desired location. ■With overload prevention function If the load exceeds the rating, hoisting will stop. Note: Overload detection may vary from 100 to 125% of the rated load depending on the operating frequency, power supply voltage, and motor temperature. ■With light load high speed function When the load is light (0 to 30% load), high-speed operation is automatically selected at 1.5 times the rated speed. Note 1: The maximum load that is considered a light load may vary from 30 to 40% of the rated load depending on the operating frequency, power supply voltage, and motor temperature. Note 2: Some models cannot be equipped with light load high speed for special high head, so please contact us separately. Note 3: The light load high speed function cannot be used when co-hanging. Please contact us separately for details. ■With electronic limit switch function The hook position is detected and the cushion stops automatically at the position set for hoisting/lowering operation. (You can easily set the upper and lower limits according to your usage. They are not set at the time of shipment.) There are other model numbers as well.

  • Product

    Hoist Standard equipped with load swing suppression function SuperV series (Type 4)

Share this product


380+ people viewing

Last viewed: 19 minutes ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Hoist Standard equipped with load swing suppression function SuperV series (Type 4)

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Hoisting inverter motor number of poles Hoisting inverter motor output (kW) Hoisting inverter rated current (A) Hoisting inverter speed 2-speed type (m/min) Hoisting inverter speed 2-speed type (m/s) Lifting height Low head (m) Lifting height Normal type (m) Lifting height double rail (m) Lifting load (t) Operating voltage Power supply (three phase) Power supply method Rated load (t) Repeat rating (load rate ≦0.63) Traversal Repetitive rating (load rate≦0.63) Hoisting Traversal Commercial Normal type/Low head Motor output Traversal Commercial Normal type/Low head Rated current Traversal Number of motor poles Traverse Commercial Double Rail Motor Output Traverse Commercial Double Rail Rated Current Traverse commercial speed (50Hz/60Hz) Traverse inverter double rail motor output Traverse inverter double rail rated current Traverse inverter normal type/low head motor output Traverse inverter normal type/low head rated current Traverse inverter speed (m/min) Traverse inverter speed (m/s) Wire rope double rail Wire rope low head Wire rope normal type
Hoist Standard equipped with load swing suppression function SuperV series (Type 4)-Part Number-Power supply voltage 200V class, rated load 1t

Power supply voltage 200V class, rated load 1t

Available upon quote 4 2.3 200V50Hz:14.0
200V60Hz:13.5
220V60Hz:12.5
1.3~13[19.5] 0.022~0.217[0.325] Low lift: 6
High head: 12
Low lift: 6
High head: 12
- 1.01 AC200V or AC220V (depending on power supply voltage) AC200V 50Hz, AC200V 60Hz, AC220V 60Hz Cable power supply (for contact type current collectors, bus ducts, etc., be sure to use double trolleys) 1 Starting frequency: 400 times/h
Load time rate: 40%ED
Starting frequency: 400 times/h
Load time rate: 40%ED
50Hz/60Hz:0.30/0.36 (kW) 200V50Hz:2.0A
200V60Hz:1.6A
220V60Hz:1.8A
Normal form: 4
Low head: 4
Double rail: NULL
- - 0.35/0.417 (m/s) - - 0.36kW 200V50Hz:1.6A
200V60Hz:1.6A
220V60Hz:1.6A
2.5~25 0.042~0.417 - Multiplication number: 4
Configuration: 6×W (19) -B
Diameter (mm) :⌀6.3
Multiplication number: 2
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀8
Hoist Standard equipped with load swing suppression function SuperV series (Type 4)-Part Number-Power supply voltage 200V class, rated load 2t

Power supply voltage 200V class, rated load 2t

Available upon quote 4 3.5 200V50Hz:20.0
200V60Hz:18.0
220V60Hz:16.0
1.0~10[15] 0.017~0.167[0.25] Low lift: 6
High head: 12
Low lift: 6
High head: 12
Low lift: NULL
High head: 12
2.02 AC200V or AC220V (depending on power supply voltage) AC200V 50Hz, AC200V 60Hz, AC220V 60Hz Cable power supply (for contact type current collectors, bus ducts, etc., be sure to use double trolleys) 2 Starting frequency: 400 times/h
Load time rate: 40%ED
Starting frequency: 400 times/h
Load time rate: 40%ED
50Hz/60Hz:0.30/0.36 (kW) 200V50Hz:2.0A
200V60Hz:1.6A
220V60Hz:1.8A
Normal form: 4
Low head: 4
Double rail: 4
50Hz/60Hz:0.30/0.36 (kW) 200V50Hz:2.0A
200V60Hz:1.6A
220V60Hz:1.8A
0.35/0.417 (m/s) 0.36kW 200V50Hz:1.6A
200V60Hz:1.6A
220V60Hz:1.6A
0.36kW 200V50Hz:1.6A
200V60Hz:1.6A
220V60Hz:1.6A
2.5~25 0.042~0.417 Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀8
Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀8
Multiplication number: 2
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀11.2
Hoist Standard equipped with load swing suppression function SuperV series (Type 4)-Part Number-Power supply voltage 200V class, rated load 2.8t

Power supply voltage 200V class, rated load 2.8t

Available upon quote 4 4.8 200V50Hz:25.0
200V60Hz:23.0
220V60Hz:21.0
0.9~9.0[13.5] 0.015~0.15[0.225] Low lift: 6
High head: 12
Low lift: 6
High head: 12
Low lift: 6
High head: 12
2.83 AC200V or AC220V (depending on power supply voltage) AC200V 50Hz, AC200V 60Hz, AC220V 60Hz Cable power supply (for contact type current collectors, bus ducts, etc., be sure to use double trolleys) 2.8 Starting frequency: 400 times/h
Load time rate: 40%ED
Starting frequency: 400 times/h
Load time rate: 40%ED
50Hz/60Hz:0.45/0.55 (kW) 200V50Hz:2.7A
200V60Hz:2.0A
220V60Hz:2.3A
Normal form: 4
Low head: 4
Double rail: 4
50Hz/60Hz:0.45/0.55 (kW) 200V50Hz:2.7A
200V60Hz:2.0A
220V60Hz:2.3A
0.35/0.417 (m/s) 0.55kW 200V50Hz:2.5A
200V60Hz:2.5A
220V60Hz:2.5A
0.55kW 200V50Hz:2.5A
200V60Hz:2.5A
220V60Hz:2.5A
2.5~25 0.042~0.417 Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀10
Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀10
Multiplication number: 2
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀14
Hoist Standard equipped with load swing suppression function SuperV series (Type 4)-Part Number-Power supply voltage 200V class, rated load 3t

Power supply voltage 200V class, rated load 3t

Available upon quote 4 5 200V50Hz:26.0
200V60Hz:24.0
220V60Hz:22.0
0.9~9.0[13.5] 0.015~0.15[0.225] Low lift: 6
High head: 12
Low lift: 6
High head: 12
Low lift: 6
High head: 12
3.03 AC200V or AC220V (depending on power supply voltage) AC200V 50Hz, AC200V 60Hz, AC220V 60Hz Cable power supply (for contact type current collectors, bus ducts, etc., be sure to use double trolleys) 3 Starting frequency: 400 times/h
Load time rate: 40%ED
Starting frequency: 400 times/h
Load time rate: 40%ED
50Hz/60Hz:0.45/0.55 (kW) 200V50Hz:2.7A
200V60Hz:2.0A
220V60Hz:2.3A
Normal form: 4
Low head: 4
Double rail: 4
50Hz/60Hz:0.45/0.55 (kW) 200V50Hz:2.7A
200V60Hz:2.0A
220V60Hz:2.3A
0.35/0.417 (m/s) 0.55kW 200V50Hz:2.5A
200V60Hz:2.5A
220V60Hz:2.5A
0.55kW 200V50Hz:2.5A
200V60Hz:2.5A
220V60Hz:2.5A
2.5~25 0.042~0.417 Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀10
Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀10
Multiplication number: 2
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀14
Hoist Standard equipped with load swing suppression function SuperV series (Type 4)-Part Number-Power supply voltage 200V class, rated load 5t

Power supply voltage 200V class, rated load 5t

Available upon quote 4 7 200V50Hz:35.0
200V60Hz:34.0
220V60Hz:30.0
0.8~8.0[12] 0.013~0.133[0.2] Low lift: 6
High head: 11
Low lift: 8
High head: 12
Low lift: 8
High head: 12
5.07 AC200V or AC220V (depending on power supply voltage) AC200V 50Hz, AC200V 60Hz, AC220V 60Hz Cable power supply (for contact type current collectors, bus ducts, etc., be sure to use double trolleys) 5 Starting frequency: 400 times/h
Load time rate: 40%ED
Starting frequency: 400 times/h
Load time rate: 40%ED
50Hz/60Hz:0.63/0.75 (kW) 200V50Hz:3.0A
200V60Hz:2.3A
220V60Hz:2.6A
Normal form: 4
Low head: 4
Double rail: 4
50Hz/60Hz:0.45/0.55 (kW) 200V50Hz:2.9A
200V60Hz:2.2A
220V60Hz:2.4A
0.35/0.417 (m/s) 0.55kW 200V50Hz:2.6A
200V60Hz:2.6A
220V60Hz:2.6A
0.75kW 200V50Hz:2.8A
200V60Hz:2.8A
220V60Hz:2.8A
2.5~25 0.042~0.417 Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀12.5
Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀12.5
Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀12.5
Hoist Standard equipped with load swing suppression function SuperV series (Type 4)-Part Number-Power supply voltage 200V class, rated load 7.5t

Power supply voltage 200V class, rated load 7.5t

Available upon quote 4 9.5 200V50Hz:46.0
200V60Hz:43.0
220V60Hz:40.0
0.72~7.2[10.8] 0.012~0.12[0.18] - Low lift: 8
High head: 12
Low lift: 8
High head: 12
7.65 AC200V or AC220V (depending on power supply voltage) AC200V 50Hz, AC200V 60Hz, AC220V 60Hz Cable power supply (for contact type current collectors, bus ducts, etc., be sure to use double trolleys) 7.5 Starting frequency: 400 times/h
Load time rate: 40%ED
Starting frequency: 400 times/h
Load time rate: 40%ED
50Hz/60Hz:0.47×2/0.56×2 (kW) 200V50Hz:3.7A×2
200V60Hz:2.6A×2
220V60Hz:3.0A×2
Normal form: 6
Low head: NULL
Double rail: 4
50Hz/60Hz:0.45×2/0.55×2 (kW) 200V50Hz:2.7A×2
200V60Hz:2.0A×2
220V60Hz:2.3A×2
0.233/0.283 (m/s) 0.55kW×2 200V50Hz:1.7A×2
200V60Hz:1.5A×2
220V60Hz:1.4A×2
0.56kW×2 200V50Hz:2.2A×2
200V60Hz:2.1A×2
220V60Hz:2.1A×2
1.7~17 0.028~0.283 Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀14
- Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀14
Hoist Standard equipped with load swing suppression function SuperV series (Type 4)-Part Number-Power supply voltage 200V class, rated load 10t

Power supply voltage 200V class, rated load 10t

Available upon quote 4 10.5 200V50Hz:54.0
200V60Hz:51.0
220V60Hz:46.0
0.6~6.0[9.0] 0.01~0.10[0.15] - Low lift: 8
High head: 12
Low lift: 8
High head: 12
10.2 AC200V or AC220V (depending on power supply voltage) AC200V 50Hz, AC200V 60Hz, AC220V 60Hz Cable power supply (for contact type current collectors, bus ducts, etc., be sure to use double trolleys) 10 Starting frequency: 400 times/h
Load time rate: 40%ED
Starting frequency: 400 times/h
Load time rate: 40%ED
50Hz/60Hz:0.47×2/0.56×2 (kW) 200V50Hz:3.7A×2
200V60Hz:2.6A×2
220V60Hz:3.0A×2
Normal form: 6
Low head: NULL
Double rail: 4
50Hz/60Hz:0.45×2/0.55×2 (kW) 200V50Hz:2.7A×2
200V60Hz:2.0A×2
220V60Hz:2.3A×2
0.233/0.283 (m/s) 0.55kW×2 200V50Hz:1.7A×2
200V60Hz:1.5A×2
220V60Hz:1.4A×2
0.56kW×2 200V50Hz:2.2A×2
200V60Hz:2.1A×2
220V60Hz:2.1A×2
1.7~17 0.028~0.283 Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀16
- Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀16
Hoist Standard equipped with load swing suppression function SuperV series (Type 4)-Part Number-Power supply voltage 400V class, rated load 1t

Power supply voltage 400V class, rated load 1t

Available upon quote 4 2.3 400V50Hz:8.0
400V60Hz:7.0
420V60Hz:7.0
1.3~13[19.5] 0.022~0.217[0.325] Low lift: 6
High head: 12
Low lift: 6
High head: 12
- 1.01 AC200V (via built-in down transformer) AC380V 50Hz, AC400V 50Hz, AC415V 50Hz, AC380V 60Hz, AC400V 60Hz, AC440V 60Hz, AC460V 60Hz, AC480V 60Hz Cable power supply (for contact type current collectors, bus ducts, etc., be sure to use double trolleys) 1 Starting frequency: 400 times/h
Load time rate: 40%ED
Starting frequency: 400 times/h
Load time rate: 40%ED
50Hz/60Hz:0.30/0.36 (kW) 400V50Hz:1.1A
400V60Hz:1.0A
420V60Hz:1.0A
Normal form: 4
Low head: 4
Double rail: NULL
- - 0.35/0.417 (m/s) - - 0.36kW 400V50Hz:0.8A
400V60Hz:0.8A
420V60Hz:0.8A
2.5~25 0.042~0.417 - Multiplication number: 4
Configuration: 6×W (19) -B
Diameter (mm) :⌀6.3
Multiplication number: 2
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀8
Hoist Standard equipped with load swing suppression function SuperV series (Type 4)-Part Number-Power supply voltage 400V class, rated load 2t

Power supply voltage 400V class, rated load 2t

Available upon quote 4 3.5 400V50Hz:10.5
400V60Hz:9.5
420V60Hz:9.5
1.0~10[15] 0.017~0.167[0.25] Low lift: 6
High head: 12
Low lift: 6
High head: 12
Low lift: NULL
High head: 12
2.02 AC200V (via built-in down transformer) AC380V 50Hz, AC400V 50Hz, AC415V 50Hz, AC380V 60Hz, AC400V 60Hz, AC440V 60Hz, AC460V 60Hz, AC480V 60Hz Cable power supply (for contact type current collectors, bus ducts, etc., be sure to use double trolleys) 2 Starting frequency: 400 times/h
Load time rate: 40%ED
Starting frequency: 400 times/h
Load time rate: 40%ED
50Hz/60Hz:0.30/0.36 (kW) 400V50Hz:1.1A
400V60Hz:1.0A
420V60Hz:1.0A
Normal form: 4
Low head: 4
Double rail: 4
50Hz/60Hz:0.30/0.36 (kW) 400V50Hz:1.1A
400V60Hz:1.0A
420V60Hz:1.0A
0.35/0.417 (m/s) 0.36kW 400V50Hz:0.8A
400V60Hz:0.8A
420V60Hz:0.8A
0.36kW 400V50Hz:0.8A
400V60Hz:0.8A
420V60Hz:0.8A
2.5~25 0.042~0.417 Multiplication number: 2
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀8
Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀8
Multiplication number: 2
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀11.2
Hoist Standard equipped with load swing suppression function SuperV series (Type 4)-Part Number-Power supply voltage 400V class, rated load 3t

Power supply voltage 400V class, rated load 3t

Available upon quote 4 5 400V50Hz:14.0
400V60Hz:13.0
420V60Hz:12.0
0.9~9.0[13.5] 0.015~0.15[0.225] Low lift: 6
High head: 12
Low lift: 6
High head: 12
Low lift: 6
High head: 12
3.03 AC200V (via built-in down transformer) AC380V 50Hz, AC400V 50Hz, AC415V 50Hz, AC380V 60Hz, AC400V 60Hz, AC440V 60Hz, AC460V 60Hz, AC480V 60Hz Cable power supply (for contact type current collectors, bus ducts, etc., be sure to use double trolleys) 3 Starting frequency: 400 times/h
Load time rate: 40%ED
Starting frequency: 400 times/h
Load time rate: 40%ED
50Hz/60Hz:0.45/0.55 (kW) 400V50Hz:1.4A
400V60Hz:1.1A
420V60Hz:1.2A
Normal form: 4
Low head: 4
Double rail: 4
50Hz/60Hz:0.45/0.55 (kW) 400V50Hz:1.4A
400V60Hz:1.1A
420V60Hz:1.2A
0.35/0.417 (m/s) 0.55kW 400V50Hz:1.2A
400V60Hz:1.2A
420V60Hz:1.2A
0.55kW 400V50Hz:1.2A
400V60Hz:1.2A
420V60Hz:1.2A
2.5~25 0.042~0.417 Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀10
Multiplication number: 4
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀10
Multiplication number: 2
Configuration: 6×Fi (29) -B
Diameter (mm) :⌀14

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Kyushu Kiden Co., Ltd.


View more products of Kyushu Kiden Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree