Clean air device 9 type Class II type A2 type-SCV-1009ECIIA2
Clean air device 9 type Class II type A2 type-Kyushu Kiden Co., Ltd.

Clean air device 9 type Class II type A2 type
Kyushu Kiden Co., Ltd.


About This Product

■Summary The biohazard countermeasure cabinet (safety cabinet), which is an infectious disease control device, is a product that achieves worker safety and contamination control. Due to the sudden outbreak of new viruses and unknown bacteria, it is essential for handling specimens such as PCR tests. The working opening height can be selected from 250 mm and 200 mm, and by expanding the area where aerosol flows backward, it is possible to improve contamination control. Class II biohazard cabinets are important devices that handle pathogens, so maintaining their performance on a daily basis is essential. Depending on the pathogens being handled, inspections are required at least once a year. We recommend a maintenance package that includes annual inspections. ■Can be used with either 250/200mm ・Automatically control the performance guaranteed wind speed of 250/200mm by operating the front shutter - If used outside of 250 or 200mm, a buzzer and "oPEn" display will warn you. Prevents misuse of opening and narrowing (When the front shutter is fully closed, "CLoS" is displayed and the buzzer does not sound.) ■Touch switch panel We use pictograms that allow you to visualize the operation. ■Increase the area where aerosol flows backward by approximately 20% Place unnecessary aerosol generation factors in the rear airflow to suppress contamination to the work area and clean area (temporary storage of laboratory equipment) ■JIS C 8159-1 straight tube LED lamp adopted Adopts JIS C 8159-1 straight tube LED lamp. User can replace the LED lamp. (LED lamp rated life 40,000 hours. JIS standard product) ■Displays the cumulative lighting time of the LED lamp When lighting starts, the cumulative time will be displayed in 10 hour increments. ■Airflow balance based on JIS/NSF test method We conduct airflow balance tests using Bacillus subtilis using our own testing equipment.

  • Product

    Clean air device 9 type Class II type A2 type

Share this product


230+ people viewing

Last viewed: 9 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

4 Models of Clean air device 9 type Class II type A2 type

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Airflow balance test method Body tightness Cross-contamination prevention test between samples Dust collection efficiency (%) Dust collection element Electronic ignition gas burner External dimensions (W×D×H) (mm) External static pressure Front shutter (colorless transparent tempered glass) Front shutter opening height Gas piping Germicidal lamp Illumination Lighting light (daylight white) Main body case Noise value (when shutter aperture is 250/200mm) Power consumption (W) During increased speed operation when clogged Power consumption (W) When shutter aperture is 250/200mm Power supply Sample protection test UV intensity Vacuum piping Ventilation air volume (m3/min) Opening 200mm Ventilation air volume (m3/min) Opening 250mm Wind speed (m/s) Automatic switching Inside the workbench Wind speed (m/s) automatic switching Inflow opening 200mm Wind speed (m/s) automatic switching Inflow opening 250mm Work outlet Workbench Worker safety testing
Clean air device 9 type Class II type A2 type-Part Number-SCV-1009ECIIA2

SCV-1009ECIIA2

Available upon quote Bacillus subtilis spores are sprayed and sampled using a JIS K3800 nebulizer. Evaluated by both JIS/NSF spray position and amount When the inside of the main unit is pressurized to 500Pa, the pressure drop after 30 minutes is 10% or less (positive pressure maintenance method) Number of colonies in a Petri dish that is more than 360 mm away from the working room wall: 2 or less 99.99% or more with 0.3μm particles, passed scan test HEPA filter (mini pleat, non-separator type) Sold separately (gas type depends on specification)
Please note that gas types 4A, 4B, and 4C cannot be used.
1,200×780×2,035 0Pa T5mm 250/200mm selectable with automatic wind speed switching function Compatible with one electronic ignition type gas burner (with gas use switch, foot switch, blower and interlock) 15W (glow type) ×1 light Average 900lx or more Straight tube LED lamp
LDL20×2 lights
Made of steel plate, painted (excluding SUS part) 65/63dB (A-weighted sound pressure level) or less 245 215/200 AC1Φ100V 50Hz or 60Hz (Plug cord with 2P grounding pole 5m 15A x 1) Number of colonies in Petri dish spread on workbench: 5 or less 40μW/cm2 or more over the entire workbench 1 piece (with rubber cap. Valve not included) 7.2~8.4 7.5~9.0 Average 0.30~0.40 Average 0.60~0.70 Average 0.50~0.60 Metal drip-proof plate type drip-proof outlet (2P, with grounding pole x 2 ports) 1 piece (total allowable current up to 5A) SUS304, JIS finish No. 4 equivalent plate Corner part has R finish Number of colonies from AGI sampler synthetic suspension: 10 or less
Number of colonies from slit sampler: 5 or less
Clean air device 9 type Class II type A2 type-Part Number-SCV-1309ECIIA2

SCV-1309ECIIA2

Available upon quote Bacillus subtilis spores are sprayed and sampled using a JIS K3800 nebulizer. Evaluated by both JIS/NSF spray position and amount When the inside of the main unit is pressurized to 500Pa, the pressure drop after 30 minutes is 10% or less (positive pressure maintenance method) Number of colonies in a Petri dish that is more than 360 mm away from the working room wall: 2 or less 99.99% or more with 0.3μm particles, passed scan test HEPA filter (mini pleat, non-separator type) Sold separately (gas type depends on specification)
Please note that gas types 4A, 4B, and 4C cannot be used.
1,500×780×2,035 0Pa T5mm 250/200mm selectable with automatic wind speed switching function Compatible with one electronic ignition type gas burner (with gas use switch, foot switch, blower and interlock) 15W (glow type) x 2 lights Average 1,000lx or more Straight tube LED lamp
LDL40×2 lights
Made of steel plate, painted (excluding SUS part) 65/63dB (A-weighted sound pressure level) or less 290 275/255 AC1Φ100V 50Hz or 60Hz (Plug cord with 2P grounding pole 5m 15A x 1) Number of colonies in Petri dish spread on workbench: 5 or less 40μW/cm2 or more over the entire workbench 1 piece (with rubber cap. Valve not included) 9.4~10.9 9.8~11.7 Average 0.30~0.40 Average 0.60~0.70 Average 0.50~0.60 Metal drip-proof plate type drip-proof outlet (2P, with grounding pole x 2 ports) 1 piece (total allowable current up to 5A) SUS304, JIS finish No. 4 equivalent plate Corner part has R finish Number of colonies from AGI sampler synthetic suspension: 10 or less
Number of colonies from slit sampler: 5 or less
Clean air device 9 type Class II type A2 type-Part Number-SCV-1609ECIIA2

SCV-1609ECIIA2

Available upon quote Bacillus subtilis spores are sprayed and sampled using a JIS K3800 nebulizer. Evaluated by both JIS/NSF spray position and amount When the inside of the main unit is pressurized to 500Pa, the pressure drop after 30 minutes is 10% or less (positive pressure maintenance method) Number of colonies in a Petri dish that is more than 360 mm away from the working room wall: 2 or less 99.99% or more with 0.3μm particles, passed scan test HEPA filter (mini pleat, non-separator type) Sold separately (gas type depends on specification)
Please note that gas types 4A, 4B, and 4C cannot be used.
1,800×780×2,035 0Pa T5mm 250/200mm selectable with automatic wind speed switching function Compatible with one electronic ignition type gas burner (with gas use switch, foot switch, blower and interlock) 15W (glow type) x 2 lights Average 1,000lx or more Straight tube LED lamp
LDL40×2 lights
Made of steel plate, painted (excluding SUS part) 67/65dB (A-weighted sound pressure level) or less 480 420/380 AC1Φ100V 50Hz or 60Hz (Plug cord with 2P grounding pole 5m 15A x 1) Number of colonies in Petri dish spread on workbench: 5 or less 40μW/cm2 or more over the entire workbench 1 piece (with rubber cap. Valve not included) 11.5~13.4 12.0~14.4 Average 0.33~0.43 Average 0.60~0.70 Average 0.50~0.60 Metal drip-proof plate type drip-proof outlet (2P, with grounding pole x 2 ports) 1 piece (total allowable current up to 5A) SUS304, JIS finish No. 4 equivalent plate Corner part has R finish Number of colonies from AGI sampler synthetic suspension: 10 or less
Number of colonies from slit sampler: 5 or less
Clean air device 9 type Class II type A2 type-Part Number-SCV-1909ECIIA2

SCV-1909ECIIA2

Available upon quote Bacillus subtilis spores are sprayed and sampled using a JIS K3800 nebulizer. Evaluated by both JIS/NSF spray position and amount When the inside of the main unit is pressurized to 500Pa, the pressure drop after 30 minutes is 10% or less (positive pressure maintenance method) Number of colonies in a Petri dish that is more than 360 mm away from the working room wall: 2 or less 99.99% or more with 0.3μm particles, passed scan test HEPA filter (mini pleat, non-separator type) Sold separately (gas type depends on specification)
Please note that gas types 4A, 4B, and 4C cannot be used.
2,150×780×2,035 0Pa T6mm 250/200mm selectable with automatic wind speed switching function Compatible with one electronic ignition type gas burner (with gas use switch, foot switch, blower and interlock) 15W (glow type) x 2 lights Average 1,000lx or more Straight tube LED lamp
LDL40×2 lights
Made of steel plate, painted (excluding SUS part) 67/65dB (A-weighted sound pressure level) or less 580 500/430 AC1Φ100V 50Hz or 60Hz (Plug cord with 2P grounding pole 5m 15A x 1) Number of colonies in Petri dish spread on workbench: 5 or less 40μW/cm2 or more over the entire workbench 1 piece (with rubber cap. Valve not included) 14.0~16.4 14.6~17.6 Average 0.30~0.40 Average 0.60~0.70 Average 0.50~0.60 Metal drip-proof plate type drip-proof outlet (2P, with grounding pole x 2 ports) 1 piece (total allowable current up to 5A) SUS304, JIS finish No. 4 equivalent plate Corner part has R finish Number of colonies from AGI sampler synthetic suspension: 10 or less
Number of colonies from slit sampler: 5 or less

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Kyushu Kiden Co., Ltd.


View more products of Kyushu Kiden Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree