About This Product

■Summary

The biohazard countermeasure cabinet (safety cabinet), which is an infectious disease control device, is a product that achieves worker safety and contamination control. Due to the sudden outbreak of new viruses and unknown bacteria, it is essential for handling specimens such as PCR tests. The working opening height can be selected from 250 mm and 200 mm, and by expanding the area where aerosol flows backward, it is possible to improve contamination control. Class II biohazard cabinets are important devices that handle pathogens, so maintaining their performance on a daily basis is essential. Depending on the pathogens being handled, inspections are required at least once a year. We recommend a maintenance package that includes annual inspections.

■Can be used with either 250/200mm

・Automatically control the performance guaranteed wind speed of 250/200mm by operating the front shutter - If used outside of 250 or 200mm, a buzzer and "oPEn" display will warn you. Prevents misuse of opening and narrowing (When the front shutter is fully closed, "CLoS" is displayed and the buzzer does not sound.)

■Touch switch panel

We use pictograms that allow you to visualize the operation.

■Increase the area where aerosol flows backward by approximately 20%

Place unnecessary aerosol generation factors in the rear airflow to suppress contamination to the work area and clean area (temporary storage of laboratory equipment)

■JIS C 8159-1 straight tube LED lamp adopted

Adopts JIS C 8159-1 straight tube LED lamp. User can replace the LED lamp. (LED lamp rated life 40,000 hours. JIS standard product)

■Displays the cumulative lighting time of the LED lamp

When lighting starts, the cumulative time will be displayed in 10 hour increments.

■Airflow balance based on JIS/NSF test method

We conduct airflow balance tests using Bacillus subtilis using our own testing equipment.

  • Product

    Clean air device 9 type Class II type A2 type

Share this product


300+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

4 Models of Clean air device 9 type Class II type A2 type

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Noise value (when shutter aperture is 250/200mm) Wind speed (m/s) automatic switching Inflow opening 250mm Wind speed (m/s) automatic switching Inflow opening 200mm Wind speed (m/s) Automatic switching Inside the workbench Power supply Electronic ignition gas burner Dust collection element Dust collection efficiency (%) Cross-contamination prevention test between samples Sample protection test UV intensity Vacuum piping Lighting light (daylight white) Illumination Power consumption (W) During increased speed operation when clogged Power consumption (W) When shutter aperture is 250/200mm Airflow balance test method Germicidal lamp External static pressure Body tightness Main body case Ventilation air volume (m3/min) Opening 250mm Ventilation air volume (m3/min) Opening 200mm External dimensions (W×D×H) (mm) Front shutter opening height Front shutter (colorless transparent tempered glass) Worker safety testing Work outlet Workbench Gas piping
Clean air device 9 type Class II type A2 type-Part Number-SCV-1009ECIIA2

SCV-1009ECIIA2

Available upon quote

65/63dB (A-weighted sound pressure level) or less

Average 0.50~0.60

Average 0.60~0.70

Average 0.30~0.40

AC1Φ100V 50Hz or 60Hz (Plug cord with 2P grounding pole 5m 15A x 1)

Sold separately (gas type depends on specification)
Please note that gas types 4A, 4B, and 4C cannot be used.

HEPA filter (mini pleat, non-separator type)

99.99% or more with 0.3μm particles, passed scan test

Number of colonies in a Petri dish that is more than 360 mm away from the working room wall: 2 or less

Number of colonies in Petri dish spread on workbench: 5 or less

40μW/cm2 or more over the entire workbench

1 piece (with rubber cap. Valve not included)

Straight tube LED lamp
LDL20×2 lights

Average 900lx or more

245

215/200

Bacillus subtilis spores are sprayed and sampled using a JIS K3800 nebulizer. Evaluated by both JIS/NSF spray position and amount

15W (glow type) ×1 light

0Pa

When the inside of the main unit is pressurized to 500Pa, the pressure drop after 30 minutes is 10% or less (positive pressure maintenance method)

Made of steel plate, painted (excluding SUS part)

7.5~9.0

7.2~8.4

1,200×780×2,035

250/200mm selectable with automatic wind speed switching function

T5mm

Number of colonies from AGI sampler synthetic suspension: 10 or less
Number of colonies from slit sampler: 5 or less

Metal drip-proof plate type drip-proof outlet (2P, with grounding pole x 2 ports) 1 piece (total allowable current up to 5A)

SUS304, JIS finish No. 4 equivalent plate Corner part has R finish

Compatible with one electronic ignition type gas burner (with gas use switch, foot switch, blower and interlock)

Clean air device 9 type Class II type A2 type-Part Number-SCV-1309ECIIA2

SCV-1309ECIIA2

Available upon quote

65/63dB (A-weighted sound pressure level) or less

Average 0.50~0.60

Average 0.60~0.70

Average 0.30~0.40

AC1Φ100V 50Hz or 60Hz (Plug cord with 2P grounding pole 5m 15A x 1)

Sold separately (gas type depends on specification)
Please note that gas types 4A, 4B, and 4C cannot be used.

HEPA filter (mini pleat, non-separator type)

99.99% or more with 0.3μm particles, passed scan test

Number of colonies in a Petri dish that is more than 360 mm away from the working room wall: 2 or less

Number of colonies in Petri dish spread on workbench: 5 or less

40μW/cm2 or more over the entire workbench

1 piece (with rubber cap. Valve not included)

Straight tube LED lamp
LDL40×2 lights

Average 1,000lx or more

290

275/255

Bacillus subtilis spores are sprayed and sampled using a JIS K3800 nebulizer. Evaluated by both JIS/NSF spray position and amount

15W (glow type) x 2 lights

0Pa

When the inside of the main unit is pressurized to 500Pa, the pressure drop after 30 minutes is 10% or less (positive pressure maintenance method)

Made of steel plate, painted (excluding SUS part)

9.8~11.7

9.4~10.9

1,500×780×2,035

250/200mm selectable with automatic wind speed switching function

T5mm

Number of colonies from AGI sampler synthetic suspension: 10 or less
Number of colonies from slit sampler: 5 or less

Metal drip-proof plate type drip-proof outlet (2P, with grounding pole x 2 ports) 1 piece (total allowable current up to 5A)

SUS304, JIS finish No. 4 equivalent plate Corner part has R finish

Compatible with one electronic ignition type gas burner (with gas use switch, foot switch, blower and interlock)

Clean air device 9 type Class II type A2 type-Part Number-SCV-1609ECIIA2

SCV-1609ECIIA2

Available upon quote

67/65dB (A-weighted sound pressure level) or less

Average 0.50~0.60

Average 0.60~0.70

Average 0.33~0.43

AC1Φ100V 50Hz or 60Hz (Plug cord with 2P grounding pole 5m 15A x 1)

Sold separately (gas type depends on specification)
Please note that gas types 4A, 4B, and 4C cannot be used.

HEPA filter (mini pleat, non-separator type)

99.99% or more with 0.3μm particles, passed scan test

Number of colonies in a Petri dish that is more than 360 mm away from the working room wall: 2 or less

Number of colonies in Petri dish spread on workbench: 5 or less

40μW/cm2 or more over the entire workbench

1 piece (with rubber cap. Valve not included)

Straight tube LED lamp
LDL40×2 lights

Average 1,000lx or more

480

420/380

Bacillus subtilis spores are sprayed and sampled using a JIS K3800 nebulizer. Evaluated by both JIS/NSF spray position and amount

15W (glow type) x 2 lights

0Pa

When the inside of the main unit is pressurized to 500Pa, the pressure drop after 30 minutes is 10% or less (positive pressure maintenance method)

Made of steel plate, painted (excluding SUS part)

12.0~14.4

11.5~13.4

1,800×780×2,035

250/200mm selectable with automatic wind speed switching function

T5mm

Number of colonies from AGI sampler synthetic suspension: 10 or less
Number of colonies from slit sampler: 5 or less

Metal drip-proof plate type drip-proof outlet (2P, with grounding pole x 2 ports) 1 piece (total allowable current up to 5A)

SUS304, JIS finish No. 4 equivalent plate Corner part has R finish

Compatible with one electronic ignition type gas burner (with gas use switch, foot switch, blower and interlock)

Clean air device 9 type Class II type A2 type-Part Number-SCV-1909ECIIA2

SCV-1909ECIIA2

Available upon quote

67/65dB (A-weighted sound pressure level) or less

Average 0.50~0.60

Average 0.60~0.70

Average 0.30~0.40

AC1Φ100V 50Hz or 60Hz (Plug cord with 2P grounding pole 5m 15A x 1)

Sold separately (gas type depends on specification)
Please note that gas types 4A, 4B, and 4C cannot be used.

HEPA filter (mini pleat, non-separator type)

99.99% or more with 0.3μm particles, passed scan test

Number of colonies in a Petri dish that is more than 360 mm away from the working room wall: 2 or less

Number of colonies in Petri dish spread on workbench: 5 or less

40μW/cm2 or more over the entire workbench

1 piece (with rubber cap. Valve not included)

Straight tube LED lamp
LDL40×2 lights

Average 1,000lx or more

580

500/430

Bacillus subtilis spores are sprayed and sampled using a JIS K3800 nebulizer. Evaluated by both JIS/NSF spray position and amount

15W (glow type) x 2 lights

0Pa

When the inside of the main unit is pressurized to 500Pa, the pressure drop after 30 minutes is 10% or less (positive pressure maintenance method)

Made of steel plate, painted (excluding SUS part)

14.6~17.6

14.0~16.4

2,150×780×2,035

250/200mm selectable with automatic wind speed switching function

T6mm

Number of colonies from AGI sampler synthetic suspension: 10 or less
Number of colonies from slit sampler: 5 or less

Metal drip-proof plate type drip-proof outlet (2P, with grounding pole x 2 ports) 1 piece (total allowable current up to 5A)

SUS304, JIS finish No. 4 equivalent plate Corner part has R finish

Compatible with one electronic ignition type gas burner (with gas use switch, foot switch, blower and interlock)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Clean Benches Products

Other products of Kyushu Kiden Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Kyushu Kiden Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

38.0hrs


Company Review

5.0
  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree