Product
Clean air device 9 type Class II type A2 typeHandling Company
Kyushu Kiden Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Airflow balance test method | Body tightness | Cross-contamination prevention test between samples | Dust collection efficiency (%) | Dust collection element | Electronic ignition gas burner | External dimensions (W×D×H) (mm) | External static pressure | Front shutter (colorless transparent tempered glass) | Front shutter opening height | Gas piping | Germicidal lamp | Illumination | Lighting light (daylight white) | Main body case | Noise value (when shutter aperture is 250/200mm) | Power consumption (W) During increased speed operation when clogged | Power consumption (W) When shutter aperture is 250/200mm | Power supply | Sample protection test | UV intensity | Vacuum piping | Ventilation air volume (m3/min) Opening 200mm | Ventilation air volume (m3/min) Opening 250mm | Wind speed (m/s) Automatic switching Inside the workbench | Wind speed (m/s) automatic switching Inflow opening 200mm | Wind speed (m/s) automatic switching Inflow opening 250mm | Work outlet | Workbench | Worker safety testing |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SCV-1009ECIIA2 |
Available upon quote | Bacillus subtilis spores are sprayed and sampled using a JIS K3800 nebulizer. Evaluated by both JIS/NSF spray position and amount | When the inside of the main unit is pressurized to 500Pa, the pressure drop after 30 minutes is 10% or less (positive pressure maintenance method) | Number of colonies in a Petri dish that is more than 360 mm away from the working room wall: 2 or less | 99.99% or more with 0.3μm particles, passed scan test | HEPA filter (mini pleat, non-separator type) |
Sold separately (gas type depends on specification) Please note that gas types 4A, 4B, and 4C cannot be used. |
1,200×780×2,035 | 0Pa | T5mm | 250/200mm selectable with automatic wind speed switching function | Compatible with one electronic ignition type gas burner (with gas use switch, foot switch, blower and interlock) | 15W (glow type) ×1 light | Average 900lx or more |
Straight tube LED lamp LDL20×2 lights |
Made of steel plate, painted (excluding SUS part) | 65/63dB (A-weighted sound pressure level) or less | 245 | 215/200 | AC1Φ100V 50Hz or 60Hz (Plug cord with 2P grounding pole 5m 15A x 1) | Number of colonies in Petri dish spread on workbench: 5 or less | 40μW/cm2 or more over the entire workbench | 1 piece (with rubber cap. Valve not included) | 7.2~8.4 | 7.5~9.0 | Average 0.30~0.40 | Average 0.60~0.70 | Average 0.50~0.60 | Metal drip-proof plate type drip-proof outlet (2P, with grounding pole x 2 ports) 1 piece (total allowable current up to 5A) | SUS304, JIS finish No. 4 equivalent plate Corner part has R finish |
Number of colonies from AGI sampler synthetic suspension: 10 or less Number of colonies from slit sampler: 5 or less |
|
SCV-1309ECIIA2 |
Available upon quote | Bacillus subtilis spores are sprayed and sampled using a JIS K3800 nebulizer. Evaluated by both JIS/NSF spray position and amount | When the inside of the main unit is pressurized to 500Pa, the pressure drop after 30 minutes is 10% or less (positive pressure maintenance method) | Number of colonies in a Petri dish that is more than 360 mm away from the working room wall: 2 or less | 99.99% or more with 0.3μm particles, passed scan test | HEPA filter (mini pleat, non-separator type) |
Sold separately (gas type depends on specification) Please note that gas types 4A, 4B, and 4C cannot be used. |
1,500×780×2,035 | 0Pa | T5mm | 250/200mm selectable with automatic wind speed switching function | Compatible with one electronic ignition type gas burner (with gas use switch, foot switch, blower and interlock) | 15W (glow type) x 2 lights | Average 1,000lx or more |
Straight tube LED lamp LDL40×2 lights |
Made of steel plate, painted (excluding SUS part) | 65/63dB (A-weighted sound pressure level) or less | 290 | 275/255 | AC1Φ100V 50Hz or 60Hz (Plug cord with 2P grounding pole 5m 15A x 1) | Number of colonies in Petri dish spread on workbench: 5 or less | 40μW/cm2 or more over the entire workbench | 1 piece (with rubber cap. Valve not included) | 9.4~10.9 | 9.8~11.7 | Average 0.30~0.40 | Average 0.60~0.70 | Average 0.50~0.60 | Metal drip-proof plate type drip-proof outlet (2P, with grounding pole x 2 ports) 1 piece (total allowable current up to 5A) | SUS304, JIS finish No. 4 equivalent plate Corner part has R finish |
Number of colonies from AGI sampler synthetic suspension: 10 or less Number of colonies from slit sampler: 5 or less |
|
SCV-1609ECIIA2 |
Available upon quote | Bacillus subtilis spores are sprayed and sampled using a JIS K3800 nebulizer. Evaluated by both JIS/NSF spray position and amount | When the inside of the main unit is pressurized to 500Pa, the pressure drop after 30 minutes is 10% or less (positive pressure maintenance method) | Number of colonies in a Petri dish that is more than 360 mm away from the working room wall: 2 or less | 99.99% or more with 0.3μm particles, passed scan test | HEPA filter (mini pleat, non-separator type) |
Sold separately (gas type depends on specification) Please note that gas types 4A, 4B, and 4C cannot be used. |
1,800×780×2,035 | 0Pa | T5mm | 250/200mm selectable with automatic wind speed switching function | Compatible with one electronic ignition type gas burner (with gas use switch, foot switch, blower and interlock) | 15W (glow type) x 2 lights | Average 1,000lx or more |
Straight tube LED lamp LDL40×2 lights |
Made of steel plate, painted (excluding SUS part) | 67/65dB (A-weighted sound pressure level) or less | 480 | 420/380 | AC1Φ100V 50Hz or 60Hz (Plug cord with 2P grounding pole 5m 15A x 1) | Number of colonies in Petri dish spread on workbench: 5 or less | 40μW/cm2 or more over the entire workbench | 1 piece (with rubber cap. Valve not included) | 11.5~13.4 | 12.0~14.4 | Average 0.33~0.43 | Average 0.60~0.70 | Average 0.50~0.60 | Metal drip-proof plate type drip-proof outlet (2P, with grounding pole x 2 ports) 1 piece (total allowable current up to 5A) | SUS304, JIS finish No. 4 equivalent plate Corner part has R finish |
Number of colonies from AGI sampler synthetic suspension: 10 or less Number of colonies from slit sampler: 5 or less |
|
SCV-1909ECIIA2 |
Available upon quote | Bacillus subtilis spores are sprayed and sampled using a JIS K3800 nebulizer. Evaluated by both JIS/NSF spray position and amount | When the inside of the main unit is pressurized to 500Pa, the pressure drop after 30 minutes is 10% or less (positive pressure maintenance method) | Number of colonies in a Petri dish that is more than 360 mm away from the working room wall: 2 or less | 99.99% or more with 0.3μm particles, passed scan test | HEPA filter (mini pleat, non-separator type) |
Sold separately (gas type depends on specification) Please note that gas types 4A, 4B, and 4C cannot be used. |
2,150×780×2,035 | 0Pa | T6mm | 250/200mm selectable with automatic wind speed switching function | Compatible with one electronic ignition type gas burner (with gas use switch, foot switch, blower and interlock) | 15W (glow type) x 2 lights | Average 1,000lx or more |
Straight tube LED lamp LDL40×2 lights |
Made of steel plate, painted (excluding SUS part) | 67/65dB (A-weighted sound pressure level) or less | 580 | 500/430 | AC1Φ100V 50Hz or 60Hz (Plug cord with 2P grounding pole 5m 15A x 1) | Number of colonies in Petri dish spread on workbench: 5 or less | 40μW/cm2 or more over the entire workbench | 1 piece (with rubber cap. Valve not included) | 14.0~16.4 | 14.6~17.6 | Average 0.30~0.40 | Average 0.60~0.70 | Average 0.50~0.60 | Metal drip-proof plate type drip-proof outlet (2P, with grounding pole x 2 ports) 1 piece (total allowable current up to 5A) | SUS304, JIS finish No. 4 equivalent plate Corner part has R finish |
Number of colonies from AGI sampler synthetic suspension: 10 or less Number of colonies from slit sampler: 5 or less |
Click on the part number for more information about each product