Product
Land pump Small horizontal direct acting motor pump JD typeHandling Company
Kyushu Kiden Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Allowable pushing pressure (MPa) | Classification by discharge pressure | Deadline total head (m) | Discharge amount (m3/min) | Handling liquid | Installation dimensions | Motor output (kW) | Motor type | Output (kW) | Standard material casing | Standard material impeller | Standard material main shaft | Standard motor specifications | Standard paint color | Total lifting head (m) | Voltage (V) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
40×32M-50.25K |
Available upon quote | 0.6 |
Discharge pressure 0.7MPa or less Discharge pressure 1.0MPa or less |
9 | 0.2 | Fresh water at 0~100℃, pH5.8~8.6 |
JIS 10K thin JIS 10K standard size |
0.4 | Totally enclosed outdoor type |
0.25~3.7 5.5~11 |
FC200 or FC250 | CAC406 (BC6) |
SUS304 (3.7kW or less) SUS403 (5.5kW or more) |
200V, 50/60Hz | Munsell 2.5PB4.6/0.8 | 3.8 |
200 200/400 dual voltage specification |
|
40×32L-50.4K |
Available upon quote | 0.56 |
Discharge pressure 0.7MPa or less Discharge pressure 1.0MPa or less |
13.3 | 0.2 | Fresh water at 0~100℃, pH5.8~8.6 |
JIS 10K thin JIS 10K standard size |
0.59 | Totally enclosed outdoor type |
0.25~3.7 5.5~11 |
FC200 or FC250 | CAC406 (BC6) |
SUS304 (3.7kW or less) SUS403 (5.5kW or more) |
200V, 50/60Hz | Munsell 2.5PB4.6/0.8 | 6.6 |
200 200/400 dual voltage specification |
|
40×32A-E50.75 |
Available upon quote | 0.48 |
Discharge pressure 0.7MPa or less Discharge pressure 1.0MPa or less |
21.3 | 0.2 | Fresh water at 0~100℃, pH5.8~8.6 |
JIS 10K thin JIS 10K standard size |
1 | Totally enclosed outdoor type |
0.25~3.7 5.5~11 |
FC200 or FC250 | CAC406 (BC6) |
SUS304 (3.7kW or less) SUS403 (5.5kW or more) |
200V, 50/60Hz | Munsell 2.5PB4.6/0.8 | 11.2 |
200 200/400 dual voltage specification |
|
40×32B-E51.5 |
Available upon quote | 0.39 |
Discharge pressure 0.7MPa or less Discharge pressure 1.0MPa or less |
30.7 | 0.05/0.22 | Fresh water at 0~100℃, pH5.8~8.6 |
JIS 10K thin JIS 10K standard size |
1.5 | Totally enclosed outdoor type |
0.25~3.7 5.5~11 |
FC200 or FC250 | CAC406 (BC6) |
SUS304 (3.7kW or less) SUS403 (5.5kW or more) |
200V, 50/60Hz | Munsell 2.5PB4.6/0.8 | 30.5/22.5 |
200 200/400 dual voltage specification |
|
40×32B-E52.2 |
Available upon quote | 0.28 |
Discharge pressure 0.7MPa or less Discharge pressure 1.0MPa or less |
42 | 0.05/0.23 | Fresh water at 0~100℃, pH5.8~8.6 |
JIS 10K thin JIS 10K standard size |
2.2 | Totally enclosed outdoor type |
0.25~3.7 5.5~11 |
FC200 or FC250 | CAC406 (BC6) |
SUS304 (3.7kW or less) SUS403 (5.5kW or more) |
200V, 50/60Hz | Munsell 2.5PB4.6/0.8 | 40.5/29.5 |
200 200/400 dual voltage specification |
|
50×40M-50.4K |
Available upon quote | 0.6 |
Discharge pressure 0.7MPa or less Discharge pressure 1.0MPa or less |
9.6 | 0.32 | Fresh water at 0~100℃, pH5.8~8.6 |
JIS 10K thin JIS 10K standard size |
0.59 | Totally enclosed outdoor type |
0.25~3.7 5.5~11 |
FC200 or FC250 | CAC406 (BC6) |
SUS304 (3.7kW or less) SUS403 (5.5kW or more) |
200V, 50/60Hz | Munsell 2.5PB4.6/0.8 | 4.3 |
200 200/400 dual voltage specification |
|
50×40L-E50.75 |
Available upon quote | 0.54 |
Discharge pressure 0.7MPa or less Discharge pressure 1.0MPa or less |
15.6 | 0.32 | Fresh water at 0~100℃, pH5.8~8.6 |
JIS 10K thin JIS 10K standard size |
1 | Totally enclosed outdoor type |
0.25~3.7 5.5~11 |
FC200 or FC250 | CAC406 (BC6) |
SUS304 (3.7kW or less) SUS403 (5.5kW or more) |
200V, 50/60Hz | Munsell 2.5PB4.6/0.8 | 9 |
200 200/400 dual voltage specification |
|
50×40A-E51.5 |
Available upon quote | 0.42 |
Discharge pressure 0.7MPa or less Discharge pressure 1.0MPa or less |
27.2 | 0.1/0.32 | Fresh water at 0~100℃, pH5.8~8.6 |
JIS 10K thin JIS 10K standard size |
1.5 | Totally enclosed outdoor type |
0.25~3.7 5.5~11 |
FC200 or FC250 | CAC406 (BC6) |
SUS304 (3.7kW or less) SUS403 (5.5kW or more) |
200V, 50/60Hz | Munsell 2.5PB4.6/0.8 | 25/16.5 |
200 200/400 dual voltage specification |
|
50×40B-E52.2 |
Available upon quote | 0.35 |
Discharge pressure 0.7MPa or less Discharge pressure 1.0MPa or less |
34.2 | 0.1/0.32 | Fresh water at 0~100℃, pH5.8~8.6 |
JIS 10K thin JIS 10K standard size |
2.2 | Totally enclosed outdoor type |
0.25~3.7 5.5~11 |
FC200 or FC250 | CAC406 (BC6) |
SUS304 (3.7kW or less) SUS403 (5.5kW or more) |
200V, 50/60Hz | Munsell 2.5PB4.6/0.8 | 32/23.5 |
200 200/400 dual voltage specification |
|
50×40C-E53.7 |
Available upon quote | 0.21 |
Discharge pressure 0.7MPa or less Discharge pressure 1.0MPa or less |
49 | 0.1/0.28 | Fresh water at 0~100℃, pH5.8~8.6 |
JIS 10K thin JIS 10K standard size |
3.7 | Totally enclosed outdoor type |
0.25~3.7 5.5~11 |
FC200 or FC250 | CAC406 (BC6) |
SUS304 (3.7kW or less) SUS403 (5.5kW or more) |
200V, 50/60Hz | Munsell 2.5PB4.6/0.8 | 48/37.5 |
200 200/400 dual voltage specification |
Click on the part number for more information about each product