Product
7.2kV/3.6kV thin high voltage distribution board Super compact switchgearHandling Company
Kyushu Kiden Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Control Types of protection relays | Control basic structure | Control size (width dimension) | Current transformer (multi-CT) CT ratio | Current transformer (multi-CT) accuracy class | Current transformer (multi-CT) burden | Current transformer (multi-CT) overcurrent constant | Current transformer (multi-CT) short-time withstand current | Equipment module Bus bar type | Equipment module basic structure | Equipment module rated current | Equipment module short-term withstand current, time | Equipment module size (width dimension) | Switchgear Short-time withstand current, circulation time | Switchgear Switchgear shape | Switchgear applicable standards | Switchgear basic structure | Switchgear installation location | Switchgear protection class (outer covering) | Switchgear rated current | Switchgear rated voltage | Switchgear rated withstand voltage | Vacuum circuit breaker (VCB) applicable standards | Vacuum circuit breaker (VCB) operation method | Vacuum circuit breaker (VCB) rated breaking current | Vacuum circuit breaker (VCB) rated breaking time | Vacuum circuit breaker (VCB) rated current | Vacuum circuit breaker (VCB) rated voltage | Vacuum circuit breaker (VCB) rated withstand voltage | Vacuum circuit breaker (VCB) surge absorption |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Super compact switchgear |
Available upon quote | Multifunctional complex supervisory control unit (ICU) | For upper row/lower row | 350 (1U) /700 (2U) /1,050 (3U) (depending on device) | 600/1A, 1,200/1A | 1PS | 0.6A | N>16 | 40kA, 2 seconds | Single bus/double bus/auxiliary bus/none | Upper and lower tier shared type | 600/1,200A | 12.5kA 1s/20kA 1s/25kA 1s | 350 (1U) /700 (2U) /1,050 (3U) /1,400 (4U) | 12.5kA/20kA/25kA 1s | PW class compliant | JEM1425 |
Equipment module combination structure Before and after maintenance The external control cable is routed to the terminal block in the control room. |
Indoor | IP4X (excluding storage panels such as transformer panels) IP2X for ventilation holes | 600A/1,200A (basic specifications) | 7.2kV/3.6kV | Commercial frequency 22kV 1 minute, lightning impulse 60kV | JEC-2300-2010 | Electromagnetic operation, electric spring operation | 12.5kA, 20kA, 25kA | 3 cycles | 600A, 600A, 1,200A, 600A, 1,200A | 7.2/3.6kV, 7.2/3.6kV, 3.6kV | Commercial frequency 22kV 1 minute, lightning impulse 60kV | CR series element or non-linear resistance |