High frequency inverter SJH700 series 400V class-SJH700-2.5HF
High frequency inverter SJH700 series 400V class-Kyushu Kiden Co., Ltd.

High frequency inverter SJH700 series 400V class
Kyushu Kiden Co., Ltd.


About This Product

■High frequency inverter equipped with a variety of functions ・Expand the maximum frequency to up to 2,000Hz ・Achieved a 10-year design life with long-life fans and capacitors ■Machines that require high-speed rotation ・High-speed frequency: Expanded to 2,000Hz, suitable for machine tools and processing machines that require high-speed rotation ・Rotation speed 120,000min-1 (Number of motor poles: 2 poles) ■ Customization possible with program operation function The host controller/peripheral circuit can be simplified, contributing to space savings and cost reductions in the control panel. ■Function ・Relay circuit (self-holding), timer circuit ・Repetitive operation (automatic operation) ・Change inverter parameters depending on operating conditions (multiple acceleration/deceleration time settings, etc.) ■Achieved a 10-year design life with long-life fans and capacitors ・This is an inverter that can be used more safely and for a longer period of time. ・Limited life parts (cooling fan, electrolytic capacitor) have a design life of 10 years. ■Compact design saves space Built-in EMC noise filter (8kVA excluded) ■Extensive network support Equipped with RS-485Modbus-RTU compatible port as standard. ■Equipped with various functions ・Enhanced monitoring function (maintenance notice signal) ・Microsurge suppression ・Data changes can be checked using the data compare function

  • Product

    High frequency inverter SJH700 series 400V class

Share this product


120+ people viewing

Last viewed: 9 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

7 Models of High frequency inverter SJH700 series 400V class

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Acceleration/deceleration time Braking torque DC braking Braking torque Minimum connectable resistance value (Ω) Braking torque Regenerative braking short time Control method Display monitor EMC filter Frequency accuracy Frequency resolution Input signal Forward/reverse run/stop External port Input signal Forward/reverse run/stop External signal Input signal Forward/reverse run/stop Operator Input signal Frequency setting External port Input signal Frequency setting External signal Input signal Frequency setting Operator Input signal Thermistor input terminal Output frequency range Output signal Intelligent monitor output terminal Output signal Intelligent output terminal Overload current rating Protection function Protective structure Rated capacity (kVA) 400V Rated capacity (kVA) 480V Rated input AC voltage Rated output current (A) Rated output voltage Usage environment Ambient temperature/storage temperature/humidity Voltage/frequency characteristics Zero phase reactor
High frequency inverter SJH700 series 400V class-Part Number-SJH700-2.5HF

SJH700-2.5HF

Available upon quote 0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable) 100 Built-in BRD circuit (separate discharge resistor) PWM method Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc. Built-in (EN61800-3 cat.C3) Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V) Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) Forward run/stop (1a, 1b selectable, 3 wire input possible) Run/stop (switch forward/reverse with code) Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω) Setting by UP key/DOWN key 1 terminal (PTC characteristics/NTC characteristics) 0.1~2,000Hz Analog voltage output, analog current output, pulse output Open collector 5 terminals, relay output (1C contact) 1 terminal selection
(Select from during driving, when reaching constant speed, above set frequency, alarm signal, etc.)
150%/60 seconds, 200%/3 seconds Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error,
Phase loss error, braking resistor overload, CT error, external trip, communication error, option error
IP20 2.6 3.1 Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz 3.8 Three-phase (3-wire) 380~480V (corresponds to the receiving voltage) -10℃~50℃/-20℃~65℃/20~90%RH (no condensation) V/f arbitrary setting, V/f control (constant torque, reduced torque) Built-in
High frequency inverter SJH700 series 400V class-Part Number-SJH700-3.5HF

SJH700-3.5HF

Available upon quote 0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable) 100 Built-in BRD circuit (separate discharge resistor) PWM method Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc. Built-in (EN61800-3 cat.C3) Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V) Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) Forward run/stop (1a, 1b selectable, 3 wire input possible) Run/stop (switch forward/reverse with code) Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω) Setting by UP key/DOWN key 1 terminal (PTC characteristics/NTC characteristics) 0.1~2,000Hz Analog voltage output, analog current output, pulse output Open collector 5 terminals, relay output (1C contact) 1 terminal selection
(Select from during driving, when reaching constant speed, above set frequency, alarm signal, etc.)
150%/60 seconds, 200%/3 seconds Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error,
Phase loss error, braking resistor overload, CT error, external trip, communication error, option error
IP20 3.6 4.4 Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz 5.3 Three-phase (3-wire) 380~480V (corresponds to the receiving voltage) -10℃~50℃/-20℃~65℃/20~90%RH (no condensation) V/f arbitrary setting, V/f control (constant torque, reduced torque) Built-in
High frequency inverter SJH700 series 400V class-Part Number-SJH700-5.5HF

SJH700-5.5HF

Available upon quote 0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable) 70 Built-in BRD circuit (separate discharge resistor) PWM method Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc. Built-in (EN61800-3 cat.C3) Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V) Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) Forward run/stop (1a, 1b selectable, 3 wire input possible) Run/stop (switch forward/reverse with code) Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω) Setting by UP key/DOWN key 1 terminal (PTC characteristics/NTC characteristics) 0.1~2,000Hz Analog voltage output, analog current output, pulse output Open collector 5 terminals, relay output (1C contact) 1 terminal selection
(Select from during driving, when reaching constant speed, above set frequency, alarm signal, etc.)
150%/60 seconds, 200%/3 seconds Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error,
Phase loss error, braking resistor overload, CT error, external trip, communication error, option error
IP20 6.2 7.4 Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz 9 Three-phase (3-wire) 380~480V (corresponds to the receiving voltage) -10℃~50℃/-20℃~65℃/20~90%RH (no condensation) V/f arbitrary setting, V/f control (constant torque, reduced torque) Built-in
High frequency inverter SJH700 series 400V class-Part Number-SJH700-8HF

SJH700-8HF

Available upon quote 0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable) 70 Built-in BRD circuit (separate discharge resistor) PWM method Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc. - Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V) Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) Forward run/stop (1a, 1b selectable, 3 wire input possible) Run/stop (switch forward/reverse with code) Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω) Setting by UP key/DOWN key 1 terminal (PTC characteristics/NTC characteristics) 0.1~2,000Hz Analog voltage output, analog current output, pulse output Open collector 5 terminals, relay output (1C contact) 1 terminal selection
(Select from during driving, when reaching constant speed, above set frequency, alarm signal, etc.)
150%/60 seconds, 200%/3 seconds Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error,
Phase loss error, braking resistor overload, CT error, external trip, communication error, option error
IP20 9.7 11.6 Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz 14 Three-phase (3-wire) 380~480V (corresponds to the receiving voltage) -10℃~50℃/-20℃~65℃/20~90%RH (no condensation) V/f arbitrary setting, V/f control (constant torque, reduced torque) -
High frequency inverter SJH700 series 400V class-Part Number-SJH700-11HFF

SJH700-11HFF

Available upon quote 0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable) 35 Built-in BRD circuit (separate discharge resistor) PWM method Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc. Built-in (EN61800-3 cat.C3) Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V) Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) Forward run/stop (1a, 1b selectable, 3 wire input possible) Run/stop (switch forward/reverse with code) Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω) Setting by UP key/DOWN key 1 terminal (PTC characteristics/NTC characteristics) 0.1~2,000Hz Analog voltage output, analog current output, pulse output Open collector 5 terminals, relay output (1C contact) 1 terminal selection
(Select from during driving, when reaching constant speed, above set frequency, alarm signal, etc.)
150%/60 seconds, 200%/3 seconds Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error,
Phase loss error, braking resistor overload, CT error, external trip, communication error, option error
IP20 13.1 15.7 Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz 19 Three-phase (3-wire) 380~480V (corresponds to the receiving voltage) -10℃~50℃/-20℃~65℃/20~90%RH (no condensation) V/f arbitrary setting, V/f control (constant torque, reduced torque) Built-in
High frequency inverter SJH700 series 400V class-Part Number-SJH700-16HFF

SJH700-16HFF

Available upon quote 0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable) 35 Built-in BRD circuit (separate discharge resistor) PWM method Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc. Built-in (EN61800-3 cat.C3) Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V) Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) Forward run/stop (1a, 1b selectable, 3 wire input possible) Run/stop (switch forward/reverse with code) Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω) Setting by UP key/DOWN key 1 terminal (PTC characteristics/NTC characteristics) 0.1~2,000Hz Analog voltage output, analog current output, pulse output Open collector 5 terminals, relay output (1C contact) 1 terminal selection
(Select from during driving, when reaching constant speed, above set frequency, alarm signal, etc.)
150%/60 seconds, 200%/3 seconds Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error,
Phase loss error, braking resistor overload, CT error, external trip, communication error, option error
IP20 17.3 20.7 Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz Twenty five Three-phase (3-wire) 380~480V (corresponds to the receiving voltage) -10℃~50℃/-20℃~65℃/20~90%RH (no condensation) V/f arbitrary setting, V/f control (constant torque, reduced torque) Built-in
High frequency inverter SJH700 series 400V class-Part Number-SJH700-22HFF

SJH700-22HFF

Available upon quote 0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable) Twenty four Built-in BRD circuit (separate discharge resistor) PWM method Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc. Built-in (EN61800-3 cat.C3) Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V) Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) Forward run/stop (1a, 1b selectable, 3 wire input possible) Run/stop (switch forward/reverse with code) Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω) Setting by UP key/DOWN key 1 terminal (PTC characteristics/NTC characteristics) 0.1~2,000Hz Analog voltage output, analog current output, pulse output Open collector 5 terminals, relay output (1C contact) 1 terminal selection
(Select from during driving, when reaching constant speed, above set frequency, alarm signal, etc.)
150%/60 seconds, 200%/3 seconds Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error,
Phase loss error, braking resistor overload, CT error, external trip, communication error, option error
IP20 22.1 26.6 Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz 32 Three-phase (3-wire) 380~480V (corresponds to the receiving voltage) -10℃~50℃/-20℃~65℃/20~90%RH (no condensation) V/f arbitrary setting, V/f control (constant torque, reduced torque) Built-in

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Kyushu Kiden Co., Ltd.


View more products of Kyushu Kiden Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree