High frequency inverter SJH700 series 400V class-SJH700-2.5HF
High frequency inverter SJH700 series 400V class-Kyushu Kiden Co., Ltd.

High frequency inverter SJH700 series 400V class
Kyushu Kiden Co., Ltd.

Kyushu Kiden Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

29.3hours

Relatively Fast Response


About This Product

■High frequency inverter equipped with a variety of functions

・Expand the maximum frequency to up to 2,000Hz ・Achieved a 10-year design life with long-life fans and capacitors

■Machines that require high-speed rotation

・High-speed frequency: Expanded to 2,000Hz, suitable for machine tools and processing machines that require high-speed rotation ・Rotation speed 120,000min-1 (Number of motor poles: 2 poles)

■ Customization possible with program operation function

The host controller/peripheral circuit can be simplified, contributing to space savings and cost reductions in the control panel.

■Function

・Relay circuit (self-holding), timer circuit ・Repetitive operation (automatic operation) ・Change inverter parameters depending on operating conditions (multiple acceleration/deceleration time settings, etc.)

■Achieved a 10-year design life with long-life fans and capacitors

・This is an inverter that can be used more safely and for a longer period of time. ・Limited life parts (cooling fan, electrolytic capacitor) have a design life of 10 years.

■Compact design saves space

Built-in EMC noise filter (8kVA excluded)

■Extensive network support

Equipped with RS-485Modbus-RTU compatible port as standard.

■Equipped with various functions

・Enhanced monitoring function (maintenance notice signal) ・Microsurge suppression ・Data changes can be checked using the data compare function

  • Product

    High frequency inverter SJH700 series 400V class

Share this product


310+ people viewing

Last viewed: 5 minutes ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

7 Models of High frequency inverter SJH700 series 400V class

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Voltage/frequency characteristics Zero phase reactor Overload current rating Rated capacity (kVA) 480V Rated capacity (kVA) 400V Rated output current (A) Rated output voltage Rated input AC voltage Frequency accuracy Frequency resolution Acceleration/deceleration time Control method Braking torque DC braking Braking torque Minimum connectable resistance value (Ω) Braking torque Regenerative braking short time Output frequency range Output signal Intelligent output terminal Output signal Intelligent monitor output terminal Input signal Forward/reverse run/stop External signal Input signal Forward/reverse run/stop External port Input signal Forward/reverse run/stop Operator Input signal Frequency setting External signal Input signal Frequency setting External port Input signal Frequency setting Operator Input signal Thermistor input terminal Protection function Protective structure Usage environment Ambient temperature/storage temperature/humidity Display monitor EMC filter
High frequency inverter SJH700 series 400V class-Part Number-SJH700-2.5HF

SJH700-2.5HF

Available upon quote

V/f arbitrary setting, V/f control (constant torque, reduced torque)

Built-in

150%/60 seconds, 200%/3 seconds

3.1

2.6

3.8

Three-phase (3-wire) 380~480V (corresponds to the receiving voltage)

Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz

Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency

Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V)

0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible

PWM method

Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable)

100

Built-in BRD circuit (separate discharge resistor)

0.1~2,000Hz

Open collector 5 terminals, relay output (1C contact) 1 terminal selection
(Select from during driving, when reaching constant speed, above set frequency, alarm signal, etc.)

Analog voltage output, analog current output, pulse output

Forward run/stop (1a, 1b selectable, 3 wire input possible)

Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable)

Run/stop (switch forward/reverse with code)

DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω)

Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable)

Setting by UP key/DOWN key

1 terminal (PTC characteristics/NTC characteristics)

Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error,
Phase loss error, braking resistor overload, CT error, external trip, communication error, option error

IP20

-10℃~50℃/-20℃~65℃/20~90%RH (no condensation)

Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc.

Built-in (EN61800-3 cat.C3)

High frequency inverter SJH700 series 400V class-Part Number-SJH700-3.5HF

SJH700-3.5HF

Available upon quote

V/f arbitrary setting, V/f control (constant torque, reduced torque)

Built-in

150%/60 seconds, 200%/3 seconds

4.4

3.6

5.3

Three-phase (3-wire) 380~480V (corresponds to the receiving voltage)

Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz

Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency

Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V)

0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible

PWM method

Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable)

100

Built-in BRD circuit (separate discharge resistor)

0.1~2,000Hz

Open collector 5 terminals, relay output (1C contact) 1 terminal selection
(Select from during driving, when reaching constant speed, above set frequency, alarm signal, etc.)

Analog voltage output, analog current output, pulse output

Forward run/stop (1a, 1b selectable, 3 wire input possible)

Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable)

Run/stop (switch forward/reverse with code)

DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω)

Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable)

Setting by UP key/DOWN key

1 terminal (PTC characteristics/NTC characteristics)

Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error,
Phase loss error, braking resistor overload, CT error, external trip, communication error, option error

IP20

-10℃~50℃/-20℃~65℃/20~90%RH (no condensation)

Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc.

Built-in (EN61800-3 cat.C3)

High frequency inverter SJH700 series 400V class-Part Number-SJH700-5.5HF

SJH700-5.5HF

Available upon quote

V/f arbitrary setting, V/f control (constant torque, reduced torque)

Built-in

150%/60 seconds, 200%/3 seconds

7.4

6.2

9

Three-phase (3-wire) 380~480V (corresponds to the receiving voltage)

Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz

Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency

Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V)

0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible

PWM method

Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable)

70

Built-in BRD circuit (separate discharge resistor)

0.1~2,000Hz

Open collector 5 terminals, relay output (1C contact) 1 terminal selection
(Select from during driving, when reaching constant speed, above set frequency, alarm signal, etc.)

Analog voltage output, analog current output, pulse output

Forward run/stop (1a, 1b selectable, 3 wire input possible)

Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable)

Run/stop (switch forward/reverse with code)

DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω)

Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable)

Setting by UP key/DOWN key

1 terminal (PTC characteristics/NTC characteristics)

Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error,
Phase loss error, braking resistor overload, CT error, external trip, communication error, option error

IP20

-10℃~50℃/-20℃~65℃/20~90%RH (no condensation)

Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc.

Built-in (EN61800-3 cat.C3)

High frequency inverter SJH700 series 400V class-Part Number-SJH700-8HF

SJH700-8HF

Available upon quote

V/f arbitrary setting, V/f control (constant torque, reduced torque)

-

150%/60 seconds, 200%/3 seconds

11.6

9.7

14

Three-phase (3-wire) 380~480V (corresponds to the receiving voltage)

Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz

Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency

Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V)

0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible

PWM method

Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable)

70

Built-in BRD circuit (separate discharge resistor)

0.1~2,000Hz

Open collector 5 terminals, relay output (1C contact) 1 terminal selection
(Select from during driving, when reaching constant speed, above set frequency, alarm signal, etc.)

Analog voltage output, analog current output, pulse output

Forward run/stop (1a, 1b selectable, 3 wire input possible)

Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable)

Run/stop (switch forward/reverse with code)

DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω)

Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable)

Setting by UP key/DOWN key

1 terminal (PTC characteristics/NTC characteristics)

Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error,
Phase loss error, braking resistor overload, CT error, external trip, communication error, option error

IP20

-10℃~50℃/-20℃~65℃/20~90%RH (no condensation)

Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc.

-
High frequency inverter SJH700 series 400V class-Part Number-SJH700-11HFF

SJH700-11HFF

Available upon quote

V/f arbitrary setting, V/f control (constant torque, reduced torque)

Built-in

150%/60 seconds, 200%/3 seconds

15.7

13.1

19

Three-phase (3-wire) 380~480V (corresponds to the receiving voltage)

Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz

Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency

Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V)

0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible

PWM method

Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable)

35

Built-in BRD circuit (separate discharge resistor)

0.1~2,000Hz

Open collector 5 terminals, relay output (1C contact) 1 terminal selection
(Select from during driving, when reaching constant speed, above set frequency, alarm signal, etc.)

Analog voltage output, analog current output, pulse output

Forward run/stop (1a, 1b selectable, 3 wire input possible)

Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable)

Run/stop (switch forward/reverse with code)

DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω)

Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable)

Setting by UP key/DOWN key

1 terminal (PTC characteristics/NTC characteristics)

Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error,
Phase loss error, braking resistor overload, CT error, external trip, communication error, option error

IP20

-10℃~50℃/-20℃~65℃/20~90%RH (no condensation)

Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc.

Built-in (EN61800-3 cat.C3)

High frequency inverter SJH700 series 400V class-Part Number-SJH700-16HFF

SJH700-16HFF

Available upon quote

V/f arbitrary setting, V/f control (constant torque, reduced torque)

Built-in

150%/60 seconds, 200%/3 seconds

20.7

17.3

Twenty five

Three-phase (3-wire) 380~480V (corresponds to the receiving voltage)

Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz

Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency

Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V)

0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible

PWM method

Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable)

35

Built-in BRD circuit (separate discharge resistor)

0.1~2,000Hz

Open collector 5 terminals, relay output (1C contact) 1 terminal selection
(Select from during driving, when reaching constant speed, above set frequency, alarm signal, etc.)

Analog voltage output, analog current output, pulse output

Forward run/stop (1a, 1b selectable, 3 wire input possible)

Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable)

Run/stop (switch forward/reverse with code)

DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω)

Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable)

Setting by UP key/DOWN key

1 terminal (PTC characteristics/NTC characteristics)

Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error,
Phase loss error, braking resistor overload, CT error, external trip, communication error, option error

IP20

-10℃~50℃/-20℃~65℃/20~90%RH (no condensation)

Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc.

Built-in (EN61800-3 cat.C3)

High frequency inverter SJH700 series 400V class-Part Number-SJH700-22HFF

SJH700-22HFF

Available upon quote

V/f arbitrary setting, V/f control (constant torque, reduced torque)

Built-in

150%/60 seconds, 200%/3 seconds

26.6

22.1

32

Three-phase (3-wire) 380~480V (corresponds to the receiving voltage)

Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz

Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency

Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V)

0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible

PWM method

Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable)

Twenty four

Built-in BRD circuit (separate discharge resistor)

0.1~2,000Hz

Open collector 5 terminals, relay output (1C contact) 1 terminal selection
(Select from during driving, when reaching constant speed, above set frequency, alarm signal, etc.)

Analog voltage output, analog current output, pulse output

Forward run/stop (1a, 1b selectable, 3 wire input possible)

Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable)

Run/stop (switch forward/reverse with code)

DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω)

Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable)

Setting by UP key/DOWN key

1 terminal (PTC characteristics/NTC characteristics)

Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error,
Phase loss error, braking resistor overload, CT error, external trip, communication error, option error

IP20

-10℃~50℃/-20℃~65℃/20~90%RH (no condensation)

Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc.

Built-in (EN61800-3 cat.C3)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Power Inverters Products

Other products of Kyushu Kiden Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Kyushu Kiden Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

29.3hrs


Company Review

5.0
  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree