High frequency inverter SJH700 series 400V classHandling Company
Kyushu Kiden Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Voltage/frequency characteristics | Zero phase reactor | Overload current rating | Rated capacity (kVA) 480V | Rated capacity (kVA) 400V | Rated output current (A) | Rated output voltage | Rated input AC voltage | Frequency accuracy | Frequency resolution | Acceleration/deceleration time | Control method | Braking torque DC braking | Braking torque Minimum connectable resistance value (Ω) | Braking torque Regenerative braking short time | Output frequency range | Output signal Intelligent output terminal | Output signal Intelligent monitor output terminal | Input signal Forward/reverse run/stop External signal | Input signal Forward/reverse run/stop External port | Input signal Forward/reverse run/stop Operator | Input signal Frequency setting External signal | Input signal Frequency setting External port | Input signal Frequency setting Operator | Input signal Thermistor input terminal | Protection function | Protective structure | Usage environment Ambient temperature/storage temperature/humidity | Display monitor | EMC filter |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SJH700-2.5HF |
Available upon quote |
V/f arbitrary setting, V/f control (constant torque, reduced torque) |
Built-in |
150%/60 seconds, 200%/3 seconds |
3.1 |
2.6 |
3.8 |
Three-phase (3-wire) 380~480V (corresponds to the receiving voltage) |
Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz |
Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency |
Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V) |
0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible |
PWM method |
Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable) |
100 |
Built-in BRD circuit (separate discharge resistor) |
0.1~2,000Hz |
Open collector 5 terminals, relay output (1C contact) 1 terminal selection |
Analog voltage output, analog current output, pulse output |
Forward run/stop (1a, 1b selectable, 3 wire input possible) |
Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) |
Run/stop (switch forward/reverse with code) |
DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω) |
Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) |
Setting by UP key/DOWN key |
1 terminal (PTC characteristics/NTC characteristics) |
Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error, |
IP20 |
-10℃~50℃/-20℃~65℃/20~90%RH (no condensation) |
Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc. |
Built-in (EN61800-3 cat.C3) |
![]() |
SJH700-3.5HF |
Available upon quote |
V/f arbitrary setting, V/f control (constant torque, reduced torque) |
Built-in |
150%/60 seconds, 200%/3 seconds |
4.4 |
3.6 |
5.3 |
Three-phase (3-wire) 380~480V (corresponds to the receiving voltage) |
Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz |
Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency |
Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V) |
0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible |
PWM method |
Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable) |
100 |
Built-in BRD circuit (separate discharge resistor) |
0.1~2,000Hz |
Open collector 5 terminals, relay output (1C contact) 1 terminal selection |
Analog voltage output, analog current output, pulse output |
Forward run/stop (1a, 1b selectable, 3 wire input possible) |
Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) |
Run/stop (switch forward/reverse with code) |
DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω) |
Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) |
Setting by UP key/DOWN key |
1 terminal (PTC characteristics/NTC characteristics) |
Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error, |
IP20 |
-10℃~50℃/-20℃~65℃/20~90%RH (no condensation) |
Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc. |
Built-in (EN61800-3 cat.C3) |
![]() |
SJH700-5.5HF |
Available upon quote |
V/f arbitrary setting, V/f control (constant torque, reduced torque) |
Built-in |
150%/60 seconds, 200%/3 seconds |
7.4 |
6.2 |
9 |
Three-phase (3-wire) 380~480V (corresponds to the receiving voltage) |
Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz |
Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency |
Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V) |
0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible |
PWM method |
Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable) |
70 |
Built-in BRD circuit (separate discharge resistor) |
0.1~2,000Hz |
Open collector 5 terminals, relay output (1C contact) 1 terminal selection |
Analog voltage output, analog current output, pulse output |
Forward run/stop (1a, 1b selectable, 3 wire input possible) |
Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) |
Run/stop (switch forward/reverse with code) |
DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω) |
Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) |
Setting by UP key/DOWN key |
1 terminal (PTC characteristics/NTC characteristics) |
Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error, |
IP20 |
-10℃~50℃/-20℃~65℃/20~90%RH (no condensation) |
Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc. |
Built-in (EN61800-3 cat.C3) |
![]() |
SJH700-8HF |
Available upon quote |
V/f arbitrary setting, V/f control (constant torque, reduced torque) |
- |
150%/60 seconds, 200%/3 seconds |
11.6 |
9.7 |
14 |
Three-phase (3-wire) 380~480V (corresponds to the receiving voltage) |
Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz |
Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency |
Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V) |
0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible |
PWM method |
Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable) |
70 |
Built-in BRD circuit (separate discharge resistor) |
0.1~2,000Hz |
Open collector 5 terminals, relay output (1C contact) 1 terminal selection |
Analog voltage output, analog current output, pulse output |
Forward run/stop (1a, 1b selectable, 3 wire input possible) |
Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) |
Run/stop (switch forward/reverse with code) |
DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω) |
Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) |
Setting by UP key/DOWN key |
1 terminal (PTC characteristics/NTC characteristics) |
Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error, |
IP20 |
-10℃~50℃/-20℃~65℃/20~90%RH (no condensation) |
Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc. |
- |
![]() |
SJH700-11HFF |
Available upon quote |
V/f arbitrary setting, V/f control (constant torque, reduced torque) |
Built-in |
150%/60 seconds, 200%/3 seconds |
15.7 |
13.1 |
19 |
Three-phase (3-wire) 380~480V (corresponds to the receiving voltage) |
Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz |
Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency |
Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V) |
0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible |
PWM method |
Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable) |
35 |
Built-in BRD circuit (separate discharge resistor) |
0.1~2,000Hz |
Open collector 5 terminals, relay output (1C contact) 1 terminal selection |
Analog voltage output, analog current output, pulse output |
Forward run/stop (1a, 1b selectable, 3 wire input possible) |
Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) |
Run/stop (switch forward/reverse with code) |
DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω) |
Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) |
Setting by UP key/DOWN key |
1 terminal (PTC characteristics/NTC characteristics) |
Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error, |
IP20 |
-10℃~50℃/-20℃~65℃/20~90%RH (no condensation) |
Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc. |
Built-in (EN61800-3 cat.C3) |
![]() |
SJH700-16HFF |
Available upon quote |
V/f arbitrary setting, V/f control (constant torque, reduced torque) |
Built-in |
150%/60 seconds, 200%/3 seconds |
20.7 |
17.3 |
Twenty five |
Three-phase (3-wire) 380~480V (corresponds to the receiving voltage) |
Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz |
Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency |
Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V) |
0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible |
PWM method |
Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable) |
35 |
Built-in BRD circuit (separate discharge resistor) |
0.1~2,000Hz |
Open collector 5 terminals, relay output (1C contact) 1 terminal selection |
Analog voltage output, analog current output, pulse output |
Forward run/stop (1a, 1b selectable, 3 wire input possible) |
Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) |
Run/stop (switch forward/reverse with code) |
DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω) |
Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) |
Setting by UP key/DOWN key |
1 terminal (PTC characteristics/NTC characteristics) |
Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error, |
IP20 |
-10℃~50℃/-20℃~65℃/20~90%RH (no condensation) |
Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc. |
Built-in (EN61800-3 cat.C3) |
![]() |
SJH700-22HFF |
Available upon quote |
V/f arbitrary setting, V/f control (constant torque, reduced torque) |
Built-in |
150%/60 seconds, 200%/3 seconds |
26.6 |
22.1 |
32 |
Three-phase (3-wire) 380~480V (corresponds to the receiving voltage) |
Three-phase (3-wire) 380~480V (+10%, -15%) 50Hz/60Hz |
Digital command ±0.01%, analog command ±0.2% (25±10℃) for maximum frequency |
Digital setting: 0.01Hz, analog setting: Maximum frequency /4000 (O terminal: 12bit /0~+10V, O2 terminal: 12bit /-10~+10V) |
0.01~3,600 seconds (straight line/curve, acceleration, deceleration individual settings), 2nd acceleration/deceleration setting possible |
PWM method |
Operates at a speed below the deceleration frequency caused by a stop command at start, or by external input (brake force, time, and frequency adjustable) |
Twenty four |
Built-in BRD circuit (separate discharge resistor) |
0.1~2,000Hz |
Open collector 5 terminals, relay output (1C contact) 1 terminal selection |
Analog voltage output, analog current output, pulse output |
Forward run/stop (1a, 1b selectable, 3 wire input possible) |
Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) |
Run/stop (switch forward/reverse with code) |
DC0~10V, -10~+10V (input impedance 10kΩ), 4~20mA (input impedance 100Ω) |
Settings via RS485 communication (Hitachi protocol/Modbus-RTU selectable) |
Setting by UP key/DOWN key |
1 terminal (PTC characteristics/NTC characteristics) |
Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault current at startup, instantaneous power outage, USP error, |
IP20 |
-10℃~50℃/-20℃~65℃/20~90%RH (no condensation) |
Output frequency, output current, frequency conversion value, trip history, input/output terminal status, input power, output voltage, etc. |
Built-in (EN61800-3 cat.C3) |