Product
Inverter WJ series C1Handling Company
Kyushu Kiden Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Applicable motor capacity | Approximate mass (kg) | Control torque Connectable regenerative braking resistance (Ω) | Control torque Regenerative braking | Cooling method | Rated input voltage | Rated output capacity (kVA) Basic | Rated output capacity (kVA) expansion | Rated output current (A) Basic | Rated output current (A) extended | Rated output voltage | Specification |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C1-004MF2 |
Available upon quote |
KWND:0.4 HPND:1/2 |
1.1 | 100 | Built-in braking circuit (separate discharge resistor) | Natural air cooling (no fan) | Single phase 100V~120V (-15%/+10%), 50/60Hz ±5% |
200VND:1.0 240VND:1.2 |
200VND:1.1 240VND:1.3 |
ND:3 | ND:3.2 | 3 phase 200~240V | Single phase 100V class specifications | |
C1-007MF2 |
Available upon quote |
KWND:0.75 HPND:1.0 |
1.5 | 50 | Built-in braking circuit (separate discharge resistor) | Natural air cooling (no fan) | Single phase 100V~120V (-15%/+10%), 50/60Hz ±5% |
200VND:1.7 240VND:2.0 |
200VND:1.7 240VND:2.0 |
ND:5 | ND:5 | 3 phase 200~240V | Single phase 100V class specifications | |
C1-001SF2 |
Available upon quote |
KWLD:0.2 ND:0.1 HPLD:1/4 ND:1/8 |
1 | 100 | Built-in braking circuit (separate discharge resistor) | Natural air cooling (no fan) | Single phase 200V~240V (-15%/+10%), 50/60Hz±5% |
200VLD:0.4 ND:0.2 240VLD:0.4 ND:0.3 |
200VLD:0.4 ND:0.2 240VLD:0.5 ND:0.3 |
LD:1.2 ND:1.0 |
LD:1.3 ND:1.0 |
3 phase 200~240V | Single phase 200V class specifications | |
C1-002SF2 |
Available upon quote |
KWLD:0.4 ND:0.2 HPLD:1/2 ND:1/4 |
1 | 100 | Built-in braking circuit (separate discharge resistor) | Natural air cooling (no fan) | Single phase 200V~240V (-15%/+10%), 50/60Hz±5% |
200VLD:0.6 ND:0.5 240VLD:0.7 ND:0.6 |
200VLD:0.7 ND:0.5 240VLD:0.8 ND:0.6 |
LD:1.9 ND:1.6 |
LD:2.0 ND:1.6 |
3 phase 200~240V | Single phase 200V class specifications | |
C1-004SF2 |
Available upon quote |
KWLD:0.55 ND:0.4 HPLD:3/4 ND:1/2 |
1.1 | 100 | Built-in braking circuit (separate discharge resistor) | Natural air cooling (no fan) | Single phase 200V~240V (-15%/+10%), 50/60Hz±5% |
200VLD:1.2 LD:1.0 240VND:1.4 LD:1.2 |
200VLD:1.2 ND:1.1 240VLD:1.4 ND:1.3 |
LD:3.5 ND:3.0 |
LD:3.5 ND:3.2 |
3 phase 200~240V | Single phase 200V class specifications | |
C1-007SF2 |
Available upon quote |
KWLD:1.1 ND:0.75 HPLD:1.5 ND:1 |
1.6 | 50 | Built-in braking circuit (separate discharge resistor) | Natural air cooling (no fan) | Single phase 200V~240V (-15%/+10%), 50/60Hz±5% |
200V LD:2.0 ND:1.7 240V LD:2.4 ND:2.0 |
200V LD:2.0 ND:1.7 240V LD:2.4 ND:2.0 |
LD:6.0 ND:5.0 |
LD:6.0 ND:5.0 |
3 phase 200~240V | Single phase 200V class specifications | |
C1-015SF2 |
Available upon quote |
KWLD:2.2 ND:1.5 HPLD:3 ND:2 |
1.8 | 50 | Built-in braking circuit (separate discharge resistor) | Forced air cooling (with FAN) | Single phase 200V~240V (-15%/+10%), 50/60Hz±5% |
200VLD:3.3 ND:2.7 240VLD:3.9 ND:3.3 |
200VLD:3.4 ND:2.7 240VLD:4.0 ND:3.3 |
LD:9.6 ND:8.0 |
LD:9.8 ND:8.0 |
3 phase 200~240V | Single phase 200V class specifications | |
C1-022SF2 |
Available upon quote |
KWLD:3.0 ND:2.2 HPLD:4 ND:3 |
1.8 | 35 | Built-in braking circuit (separate discharge resistor) | Forced air cooling (with FAN) | Single phase 200V~240V (-15%/+10%), 50/60Hz±5% |
200VLD:4.1 ND:3.8 240VLD:4.9 ND:4.2 |
200VLD:4.2 ND:3.8 240VLD:5.0 ND:4.5 |
LD:12.0 ND:11.0 |
LD:12.2 ND:11.0 |
3 phase 200~240V | Single phase 200V class specifications | |
C1-001LF2 |
Available upon quote |
KWLD:0.2 ND:0.1 HPLD:1/4 ND:1/8 |
1 | 100 | Built-in braking circuit (separate discharge resistor) | Natural air cooling (no fan) | Three-phase 200V~240V (-15%/+10%), 50/60Hz±5% |
200VLD:0.4 ND:0.2 240VLD:0.4 ND:0.3 |
200VLD:0.4 ND:0.2 240VLD:0.5 ND:0.3 |
LD:1.2 ND:1.0 |
LD:1.3 ND:1.0 |
3 phase 200~240V | Three-phase 200V class specifications | |
C1-002LF2 |
Available upon quote |
KWLD:0.4 ND:0.2 HPLD:1/2 ND:1/4 |
1 | 100 | Built-in braking circuit (separate discharge resistor) | Natural air cooling (no fan) | Three-phase 200V~240V (-15%/+10%), 50/60Hz±5% |
200VLD:0.6 ND:0.5 240VLD:0.7 ND:0.6 |
200VLD:0.7 ND:0.5 240VLD:0.8 ND:0.6 |
LD:1.9 ND:1.6 |
LD:2.0 ND:1.6 |
3 phase 200~240V | Three-phase 200V class specifications |
Click on the part number for more information about each product