Standard power supply multi 3chHandling Company
Acon Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Overcurrent protection | Overvoltage protection | Withstand voltage | Rise time | Inrush current | Short circuit protection | Dimensions (mm) | Safety standards | Operating temperature | Output current variable range | Number of outputs | Output capacity | Cooling method | Input voltage (V) | Input fluctuation | Input leakage current | Warranty period | Retention time | Storage temperature | EMC standard |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AK10W-TL |
Available upon quote |
Yes (105~150%, hiccup mode, automatic recovery) |
Yes (output cutoff, clamped with Zener diode) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 15A or less / 230V input: 30A or less (at 25℃, cold start) |
Yes |
100 (width) x 58 (vertical) x 31 (height) |
UL60950, EN60950, GB4943 |
-10 ~ +70℃ (humidity 20~93%) |
±5% |
3 |
10W |
Natural air cooling |
AC85~264V |
±0.5% or less (input AC85~264V at 100% load) |
At 230V input: 0.50mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,GB9254 |
|
AK20W-TL |
Available upon quote |
Yes (105~150%, hiccup mode, automatic recovery) |
Yes (output cutoff, clamped with Zener diode) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 15A or less / 230V input: 30A or less (at 25℃, cold start) |
Yes |
111 (width) x 78 (vertical) x 36 (height) |
UL60950, EN60950, GB4943 |
-10 ~ +70℃ (humidity 20~93%) |
±5% |
3 |
20W |
Natural air cooling |
AC85~264V |
±0.5% or less (input AC85~264V at 100% load) |
At 230V input: 0.50mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,GB9254 |
|
AK40W-TL |
Available upon quote |
Yes (105~150%, hiccup mode, automatic recovery) |
Yes (115~150%, hiccup mode, automatic recovery) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start) |
Yes |
129 (width) x 98 (vertical) x 40 (height) |
UL60950, EN60950, GB4943 |
-10 ~ +70℃ (humidity 20~93%) |
±5% |
3 |
40W |
Natural air cooling |
AC85~264V |
±0.5% or less (input AC85~264V at 100% load) |
At 230V input: 0.70mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,GB9254 |
|
AK60W-TL |
Available upon quote |
Yes (105~150%, hiccup mode, automatic recovery) |
Yes (115~150%, hiccup mode, automatic recovery) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start) |
Yes |
160 (width) x 98 (vertical) x 39 (height) |
UL60950, EN60950, GB4943 |
-10 ~ +70℃ (humidity 20~93%) |
±5% |
3 |
60W |
Natural air cooling |
AC85~264V |
±0.5% or less (input AC85~264V at 100% load) |
At 230V input: 0.70mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,GB9254 |
|
AK100W-TF |
Available upon quote |
Yes (110~130%, shutdown, restart required) |
Yes (115~150%, shutdown, restart required) |
Between AC3.0kV 1min (all inputs) and (all outputs)/1.5kV AC 1min (all inputs) and (grounding [earth]/FG) AC0.5kV 1min (all outputs) and (grounding [earth]/FG) between |
50ms typ. (at 100% load) |
115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start) |
Yes |
199 (width) x 98 (vertical) x 39 (height) |
UL60950, EN60950, GB4943 |
-10 ~ +70℃ (humidity 20~93%) |
±5% |
3 |
100W |
Natural air cooling |
AC85~132V/AC170~264V |
±0.5% or less (input AC85~264V at 100% load) |
At 230V input: 0.70mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,GB9254 |