Rated current: 10~125W 2 outputs simultaneously such as 5V+12V, 5V+24V

  • Product

    Standard power supply multi 2ch

Share this product


410+ people viewing

Last viewed: 1 hour ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

6 Models of Standard power supply multi 2ch

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Static input variation Overvoltage protection Overload protection Withstand voltage Rise time Inrush current Short circuit protection Dimensions (mm) Safety standards Operating temperature Output current variable range Number of outputs Output capacity Cooling method Input voltage (V) Input fluctuation Input frequency Input leakage current Warranty period Retention time Storage temperature EMC standard Static load fluctuation Overcurrent protection
Standard power supply multi 2ch-Part Number-AK35W-DEK

AK35W-DEK

Available upon quote

±0.5% or less (at 100% load)

Yes (115~150%, hiccup mode, automatic recovery)

-

Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between

50ms typ. (at 100% load)

115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start)

Yes (hiccup mode, automatic recovery)

98.5 (width) x 82 (length) x 35 (height)

Meet GB4943, UL60950, EN60950

-20 ~ +70℃ (humidity 20~93%)

±5%

2

35W

Natural air cooling

AC88~264V

-

47~63Hz

At 230V input: 1mA or less

3 years

20ms typ. (at 100% load)

-20 ~ +85℃ (humidity 20~95%)

Meet GB9254, EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11

V1: ±0.5% or less, V2: ±10% or less

Yes (105~150%, hiccup mode, automatic recovery)

Standard power supply multi 2ch-Part Number-AK55W-DEK

AK55W-DEK

Available upon quote

±0.5% or less (at 100% load)

Yes (115~150%, hiccup mode, automatic recovery)

-

Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between

50ms typ. (at 100% load)

115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start)

Yes (hiccup mode, automatic recovery)

99 (width) x 97 (vertical) x 38 (height)

Meet GB4943, UL60950, EN60950

-20 ~ +70℃ (humidity 20~93%)

±5%

2

55W

Natural air cooling

AC88~264V

-

47~63Hz

At 230V input: 1mA or less

3 years

20ms typ. (at 100% load)

-20 ~ +85℃ (humidity 20~95%)

Meet GB9254, EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11

V1: ±0.5% or less, V2: ±10% or less

Yes (105~150%, hiccup mode, automatic recovery)

Standard power supply multi 2ch-Part Number-AK75W-DEK

AK75W-DEK

Available upon quote

±0.5% or less (at 100% load)

Yes (115~150%, hiccup mode, automatic recovery)

-

Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between

50ms typ. (at 100% load)

115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start)

Yes (hiccup mode, automatic recovery)

129 (width) x 98 (vertical) x 39.5 (height)

Meet GB4943, UL60950, EN60950

-20 ~ +70℃ (humidity 20~93%)

±5%

2

75W

Natural air cooling

AC85~264V

-

47~63Hz

At 230V input: 1mA or less

3 years

20ms typ. (at 100% load)

-20 ~ +85℃ (humidity 20~95%)

Meet GB9254, EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11

V1: ±0.5% or less, V2: ±10% or less

Yes (105~150%, hiccup mode, automatic recovery)

Standard power supply multi 2ch-Part Number-AK50W-DSM

AK50W-DSM

Available upon quote

±0.5% or less (at 100% load)

Yes (115~150%, hiccup mode, automatic recovery)

-

Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between

50ms typ. (at 100% load)

115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start)

Yes (hiccup mode, automatic recovery)

99 (width) x 97 (vertical) x 36 (height)

Meet GB4943, UL60950, EN60950

-20 ~ +70℃ (humidity 20~93%)

±5%

2

50W

Natural air cooling

AC88~264V

-

47~63Hz

At 230V input: 1mA or less

3 years

20ms typ. (at 100% load)

-20 ~ +85℃ (humidity 20~95%)

Meet GB9254, EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11

V1: ±0.5% or less, V2: ±10% or less

Yes (105~150%, hiccup mode, automatic recovery)

Standard power supply multi 2ch-Part Number-AK125W-DSM

AK125W-DSM

Available upon quote

±0.5% or less (at 100% load)

Yes (115~150%, cutoff, restart required)

-

Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between

50ms typ. (at 100% load)

115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start)

Yes (blocked, restart required)

199 (width) x 98 (vertical) x 39 (height)

Meet GB4943, UL60950, EN60950

-20 ~ +70℃ (humidity 20~93%)

±5%

2

125W

Natural air cooling

AC88~264V

-

47~63Hz

At 230V input: 1mA or less

3 years

20ms typ. (at 100% load)

-20 ~ +85℃ (humidity 20~95%)

Meet GB9254, EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11

V1: ±0.5% or less, V2: ±10% or less

Yes (110~130%, cutoff, restart required)

Standard power supply multi 2ch-Part Number-AK65W-DPL

AK65W-DPL

Available upon quote

±0.5% or less (input AC85~264V at 100% load)

Yes (115~150%, shutdown, restart required)

Yes (105~150%, hiccup mode, automatic recovery)

Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between

50ms typ. (at 100% load)

115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start)

Yes (hiccup mode, automatic recovery)

127 (width) x 76.2 (length) x 42 (height)

Meet GB4943, UL60950, EN60950

-20 ~ +70℃ (humidity 20~93%)

±10%

2

65W

Natural air cooling

AC85~264V

±0.5% or less (input AC85~264V at 100% load)

47~63Hz

At 230V input: 1.0mA or less

3 years

20ms typ. (at 100% load)

-20 ~ +85℃ (humidity 20~95%)

Meet GB9254, EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11

- -

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Switching Regulators Products

Other products of Acon Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Acon Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

35.0hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree