Product
Standard power supply High voltageHandling Company
Acon Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Overcurrent protection | Overvoltage protection | Overheating protection | Withstand voltage | Rise time | Short circuit protection | Dimensions (mm) | Safety standards | Operating temperature | Output voltage variable range | Number of outputs | Output capacity | Output | Cooling method | Input voltage (V) | Input leakage current | Warranty period | Retention time | Storage temperature | EMC standard | Inrush current | Input fluctuation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AK240W-SV-100 |
Available upon quote |
Yes (110~130%, cutoff, automatic recovery) |
Yes (110~130%, cutoff, automatic recovery) |
- |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
Yes (blocking, automatic recovery) |
200 (width) x 110 (vertical) x 50 (height) |
- |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
1 |
240W |
DC100V 2.4A |
Natural air cooling |
AC85~132V/AC170~264V |
At 230V input: 1.0mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
- |
115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start) |
±0.5% or less (at 100% load) |
|
AK400W-SV-110 |
Available upon quote |
Yes (105% or more, current limit, automatic recovery) |
Yes (115~150%, shutdown, restart required) |
- |
Between AC1.5kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/between AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
100ms typ. (at 100% load) |
Yes (blocking, automatic recovery) |
215 (width) x 115 (vertical) x 50 (height) |
Meet GB4943, UL60950, EN60950 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
1 |
407W |
DC110V 3.7A |
Forced air cooling |
AC85~132V/AC170~264V |
At 230V input: 0.7mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Meet GB9254, EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11 |
115V input: 30A or less / 230V input: 60A or less (at 25℃, cold start) |
±0.5% or less (at 100% load) |
|
AK500W-SM-100 |
Available upon quote |
Yes (110~130%, current limit, automatic recovery) |
Yes (115~150%, shutdown, restart required) |
Yes |
Between AC1.5kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/between AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
Yes |
241 (width) x 124 (vertical) x 65 (height) |
Design refer to GB4943, UL60950, EN60950 |
-20 ~ +50℃ (humidity 20~93%) |
±10% |
1 |
500W |
DC100V 5A |
Cooling fan |
AC170~264V |
At 220V input: 1mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Design refer to GB9254, EN55022 classA |
At 115V input: 30A or less |
±0.5% or less (at 100% load) |
|
AK500W-SM-160 |
Available upon quote |
Yes (110~130%, current limit, automatic recovery) |
Yes (115~150%, shutdown, restart required) |
Yes |
Between AC1.5kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/between AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
Yes |
241 (width) x 124 (vertical) x 65 (height) |
Design refer to GB4943, UL60950, EN60950 |
-20 ~ +50℃ (humidity 20~93%) |
±10% |
1 |
512W |
DC160V 3.2A |
Cooling fan |
AC85~132V |
At 110V input: 1mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Design refer to GB9254, EN55022 classA |
At 115V input: 30A or less (at 25℃, cold start) |
±0.5% or less (at 100% load) |
|
AK1000W-SE-100 |
Available upon quote |
Yes (105~130%, shutdown, restart required) |
Yes (115~150%, shutdown, restart required) |
- |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
400ms typ. (at 100% load) |
Yes |
278 (width) x 127 (length) x 63.5 (height) |
Design meet UL508, UL62368, EN62368 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
1 |
1,008W |
DC100V 10A |
Cooling fan |
AC170~264V with AC90~132V switching |
At 230V input: 1.0mA or less |
3 years |
16ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Design meet GB9254, EN55032 Class B EN55024, EN61000-3-2,3 EN61000-4-2,3,4,5,6,8,11 |
At 115V input: 30A or less, at 230V input: 60A or less (at 25℃, cold start) |
±0.5% or less (at 100% load) |
|
AK1000W-S-100 |
Available upon quote |
Yes (110~130%, current limit, automatic recovery) |
Yes (115~150%, shutdown, restart required) |
- |
Between AC1.5kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/between AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
Yes |
250 (width) x 160 (vertical) x 87 (height) |
Design refer to GB4943, UL60950, EN60950 |
-20 ~ +50℃ (humidity 20~93%) |
±10% |
1 |
1,000W |
DC100V 10A |
Cooling fan |
AC85~132V or AC170~264V |
At 230V input: 0.7mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Design refer to GB9254, EN55022 classA |
At 230V input: 60A or less (at 25℃, cold start) |
±0.5% or less (at 100% load) |
|
AK1500W-S-110 |
Available upon quote |
Yes (140% or more, current limit, automatic recovery) |
Yes (115~150%, shutdown, restart required) |
- |
Between AC1.5kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/between AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
400ms typ. (at 100% load) |
Yes |
250 (width) x 160 (vertical) x 87 (height) |
Design refer to GB4943, UL60950, EN60950 |
-20 ~ +50℃ (humidity 20~93%) |
±10% |
1 |
1,500W |
DC110V13.6A |
Cooling fan |
AC170~264V |
At 230V input: 1.0mA or less |
3 years |
10ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Design refer to GB9254, EN55022 classA |
At 220V input: 50A or less (at 25℃, cold start) |
±0.5% or less (at 100% load) |
|
AK400W-SVR |
Available upon quote |
Yes (105% or more, current limit, automatic recovery) |
Yes (115~150%, shutdown, restart required) |
- |
Between AC1.5kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/between AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
100ms typ. (at 100% load) |
Yes (blocking, automatic recovery) |
215 (width) x 115 (vertical) x 50 (height) |
Meet GB4943, UL60950, EN60950 |
-20 ~ +50℃ (humidity 20~93%) |
0~100%/0~110V |
1 |
400W |
- |
Forced air cooling |
AC85~132V/AC170~264V |
At 230V input: 0.7mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Meet GB9254, EN55022 classA, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11 |
115V input: 30A or less / 230V input: 60A or less (at 25℃, cold start) |
±0.5% or less (at 100% load) |
|
AK2400W-SCN-24 |
Available upon quote |
Shuts off at 100 ~ 112% of rated current, restart required |
Shuts off at 115~140% of rated voltage, restart required |
Shutdown, automatic recovery after temperature drop |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC2.0kV 1min (all inputs) and (ground [earth]/FG)/AC0.5KV 1min (all outputs) and (ground [earth]/FG) ) between |
100ms typ. (at 100% load) |
Shutdown, automatic recovery |
278 (width) x 178 (length) x 63.5 (height) |
UL60950 design compliant |
-20 ~ +70℃ (humidity 20~90%) |
20~100% |
1 |
2,400W |
DC24V/100A |
Cooling fan |
AC220V (AC180~AC264) |
At 230V input: 2mA or less |
3 years |
10ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
EN55022 ClassB, EN61000-3-2,3 design compliant |
- | - |
Click on the part number for more information about each product