Image | Part Number | Price (excluding tax) | Overcurrent protection | Overvoltage protection | Overheating protection | Withstand voltage | Rise time | Short circuit protection | Dimensions (mm) | Capacity | Safety standards | Operating temperature | Output voltage variable range | Number of outputs | Output capacity | Cooling method | Input current | Input voltage (V) | Input frequency | Input leakage current | Warranty period | Retention time | Storage temperature | EMC standard | Inrush current | Input fluctuation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AK100W-SVR |
Available upon quote |
Yes (110~130%, shutdown, restart required) |
Yes (115~150%, shutdown, restart required) |
- |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
Yes (blocked, restart required) |
199 (width) x 98 (vertical) x 39 (height) |
100W |
Meet GB4943, UL60950, EN60950 |
-20 ~ +70℃ (humidity 20~93%) |
0.1~100%・24V type 0.1~24V・48V type 0.1~48V |
1 |
100W |
Natural air cooling |
- |
AC85~132V/AC170~264V |
47~63Hz |
At 230V input: 1.0mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Meet GB9254, EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11 |
115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start) |
±0.5% or less (at 100% load) |
|
AK240W-SVR-24 |
Available upon quote |
Yes (105% or more, current limit, automatic recovery) |
Yes (115~150%, shutdown, restart required) |
- |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
800ms typ. (at 100% load) |
Yes (blocking, automatic recovery) |
215 (width) x 115 (vertical) x 50 (height) |
240W |
Meet GB4943, UL62368, EN62368 |
-20 ~ +70℃ (humidity 20~93%) |
±10% from rated value when using volume |
1 |
240W |
Natural air cooling |
- |
AC85~132V/AC170~264V |
47~63Hz |
At 230V input: 0.7mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Meet GB9254, EN55022 classA, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11 |
115V input: 70A or less / 230V input: 140A or less (25℃, cold start) |
±0.5% or less (at 100% load) |
|
AK400W-SVR-110 |
Available upon quote |
Yes (105% or more, current limit, automatic recovery) |
Yes (115~150%, shutdown, restart required) |
- |
Between AC1.5kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/between AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
100ms typ. (at 100% load) |
Yes (blocking, automatic recovery) |
215 (width) x 115 (vertical) x 50 (height) |
400W |
Meet GB4943, UL60950, EN60950 |
-20 ~ +50℃ (humidity 20~93%) |
0~100%/0~110V |
1 |
400W |
Forced air cooling |
- |
AC85~132V/AC170~264V |
47~63Hz |
At 230V input: 0.7mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Meet GB9254, EN55022 classA, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11 |
115V input: 30A or less / 230V input: 60A or less (at 25℃, cold start) |
±0.5% or less (at 100% load) |
|
AK400W-SVR-160 |
Available upon quote |
Yes (105% or more, current limit, automatic recovery) |
Yes (115~150%, shutdown, restart required) |
- |
Between AC1.5kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/between AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
800ms typ. (at 100% load) |
Yes (blocking, automatic recovery) |
215 (width) x 115 (vertical) x 50 (height) |
400W |
Meet GB4943, UL60950, EN60950 |
-20 ~ +70℃ (humidity 20~93%) |
0~100%/0~160V |
1 |
400W |
Forced air cooling |
- |
AC85~132V/AC170~264V |
47~63Hz |
At 230V input: 0.7mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Meet GB9254, EN55022 classA, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11 |
115V input: 70A or less / 230V input: 140A or less (25℃, cold start) |
±0.5% or less (at 100% load) |
|
AK320W-SCR |
Available upon quote |
Yes (105~150%, hiccup mode, automatic recovery) |
Yes (115~150%, output cutoff, restart required) |
- |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
Yes (hiccup mode, automatic recovery) |
215 (width) x 115 (vertical) x 50 (height) |
320W |
Meet UL60950, EN60950, GB4943 |
-20 ~ +70℃ (humidity 20~93%) |
- |
1 |
320W |
Cooling fan |
- |
AC88~264V |
47~63Hz |
At 230V input: 1.0mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Meet EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11, GB9254 |
115V input: 30A or less / 230V input: 60A or less (at 25℃, cold start) |
±0.5% or less (at input AC88~264V 100% load) |
|
AK2400W-SCN |
Available upon quote |
Shuts off at 100 ~ 112% of rated current, restart required |
Shuts off at 115~140% of rated voltage, restart required |
Shutdown, automatic recovery after temperature drop |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC2.0kV 1min (all inputs) and (ground [earth]/FG)/AC0.5KV 1min (all outputs) and (ground [earth]/FG) ) between |
100ms typ. (at 100% load) |
Shutdown, automatic recovery |
278 (width) x 178 (length) x 63.5 (height) |
2,400W |
UL60950 design compliant |
-20 ~ +70℃ (humidity 20~90%) |
20~100% |
1 |
2,400W |
Cooling fan |
20A/200VAC |
AC220V (AC180~AC264V) |
47~63Hz |
At 230V input: 2mA or less |
3 years |
10ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
EN55022 ClassB, EN61000-3-2,3 design compliant |
- | - |