All Categories
History
Response Rate
100.0%
Response Time
28.3hours
Relatively Fast Response
Product
Standard power supply board typeHandling Company
Acon Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Overvoltage protection | Overload protection | Withstand voltage | Rise time | Inrush current | Short circuit protection | Dimensions (mm) | Capacity | Safety standards | Operating temperature | Output voltage variable range | Output voltage/current | Number of outputs | Cooling method | Input voltage (V) | Input fluctuation | Input frequency | Input leakage current | Warranty period | Retention time | Storage temperature | EMC standard | Overcurrent protection | MTBF |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CP50W-SP |
Available upon quote |
Yes (115~150%, cutoff, automatic recovery) |
- |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
8ms typ. (at 100% load) |
At 100V input: 20A or less / At 200V input: 40A or less (at 25℃, cold start) |
Yes (blocking, automatic recovery) |
132 (width) x 50 (vertical) x 25.6 (height) |
50W |
Meet IEC60950 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
DC5V/10A |
1 |
Natural air cooling |
AC90~264V |
±0.5% or less (at input AC90~264V 100% load) |
47~63Hz |
At 230V input: 0.5mA or less |
3 years |
10ms typ. (at 100% load) |
-20 ~ +75℃ (humidity 20~95%) |
Meet EN55011/EN55022-A VCCI-A IEC61000-3-2 IEC61000-6-2 IEC61000-4-2,-3,-4,-5,-6,-8,-11 |
Yes (105~150%, cutoff, automatic recovery) |
- | |
AK65W-DPL |
Available upon quote |
Yes (115~150%, shutdown, restart required) |
Yes (105~150%, hiccup mode, automatic recovery) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start) |
Yes (hiccup mode, automatic recovery) |
127 (width) x 76.2 (length) x 42 (height) |
65W |
Meet GB4943, UL60950, EN60950 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
V1: DC5V/7A/ V2: DC12V/3.2A *Must be used within 65W |
2 |
Natural air cooling |
AC85~264V |
±0.5% or less (input AC85~264V at 100% load) |
47~63Hz |
At 230V input: 1.0mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Meet GB9254, EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11 |
- | - | |
OP-A050 |
Available upon quote | - | - |
AC3.0kV 1min between (all inputs) and (all outputs) |
100ms typ. (at 100% load) |
- | - |
62.5 (width) x 50 (length) x 22 (height) |
5W |
Design meet UL94V-0, EN62368,J61558-2-16 (H26) |
-30 ~ +80℃ (humidity 20~93%) |
- |
DC5V/1A |
1 |
Natural air cooling |
AC90~264V |
±2% or less (at input AC90~264V 100% load) |
50~60Hz |
At 230V input: 0.25mA or less |
3 years |
20ms typ. (at 100% load) |
-30 ~ +80℃ (humidity 20~95%) |
Design meet EN55022 classB,EN55024,IEC61000-3-2,3,EN61000-4-2,3,4,5,6,8,11 |
Yes (110%~150%) |
50,000 hours |
|
AK5W-SPL |
Available upon quote |
Yes (output cutoff, clamped with Zener diode) |
Yes (105~150%, hiccup mode, automatic recovery) |
Between AC3.0kV 1min (all inputs) and (all outputs)/AC1.5kV 1min (all inputs) and (ground [earth]/FG) /AC0.5KV 1min (all outputs) and (ground [earth]/FG) between |
50ms typ. (at 100% load) |
115V input: 15A or less / 230V input: 30A or less (at 25℃, cold start) |
Yes (hiccup mode, automatic recovery) |
76 (width) x 45 (vertical) x 22 (height) |
5W |
Meet GB4943, UL60950, EN60950 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
DC5V/1A |
1 |
Natural air cooling |
AC85~264V |
±0.5% or less (input AC85~264V at 100% load) |
47~63Hz |
At 230V input: 0.70mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Meet GB9254, EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11 |
- | - | |
AK15W-SPL |
Available upon quote |
Yes (output cutoff, clamped with Zener diode) |
Yes (105~150%, hiccup mode, automatic recovery) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 15A or less / 230V input: 30A or less / (25℃, cold start) |
Yes (hiccup mode, automatic recovery) |
100 (width) x 46.2 (vertical) x 22 (height) |
15W |
GB4943, UL60950, EN60950 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
DC5V/3A |
1 |
Natural air cooling |
AC85~264V |
±0.5% or less (input AC85~264V at 100% load) |
47~63Hz |
At 230V input: 0.70mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
GB9254, EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11 |
- | - | |
AK25W-SPL |
Available upon quote |
Yes (115~150%, shutdown, restart required) |
- |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 20A or less / 230V input: 40A or less / (25℃, cold start) |
Yes (hiccup mode, automatic recovery) |
107 (width) x 61 (vertical) x 28 (height) |
25W |
Meet GB4943, UL60950, EN60950 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
DC5V/5A |
1 |
Natural air cooling |
AC85~264V |
±0.5% or less (input AC85~264V at 100% load) |
47~63Hz |
At 230V input: 1.0mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Meet GB9254, EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11 |
Yes (105~150%, hiccup mode, automatic recovery) |
- | |
AK35W-SPL |
Available upon quote |
Yes (115~150%, shutdown, restart required) |
Yes (105~150%, hiccup mode, automatic recovery) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start) |
Yes (hiccup mode, automatic recovery) |
107 (width) x 61 (vertical) x 28 (height) |
35W |
Meet GB4943, UL60950, EN60950 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
DC5V/7A |
1 |
Natural air cooling |
AC85~264V |
±0.5% or less (input AC85~264V at 100% load) |
47~63Hz |
At 230V input: 1.0mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃< (Humidity 20~95%) /td> |
Meet GB9254, EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11 |
- | - | |
AK45W-SPL |
Available upon quote |
Yes (115~150%, shutdown, restart required) |
Yes (105~150%, hiccup mode, automatic recovery) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start) |
Yes (hiccup mode, automatic recovery) |
127 (width) x 76.2 (vertical) x 27 (height) |
45W |
Meet GB4943, UL60950, EN60950 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
DC5V/8A |
1 |
Natural air cooling |
AC85~264V |
±0.5% or less (input AC85~264V at 100% load) |
47~63Hz |
At 230V input: 1.0mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Meet GB9254, EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11 |
- | - | |
AK60W-FM |
Available upon quote |
Yes (140%, shutdown, restart required) |
- |
Between AC4.0kV 1min (all inputs) and (all outputs)/between AC2.5kV 1min (all inputs) and (ground [earth]/FG) |
3s typ. (at 100% load) |
115V input: 40A or less / 230V input: 80A or less (at 25℃, cold start) |
Yes (hiccup mode, automatic recovery) |
50.8 (width) x 76.2 (vertical) x 24 (height) |
60W |
Meet FCC PART15,CISPR32,EN55032,UL62368-1,cUL62368-1,IEC62368-1, |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
DC12V/5.0A |
1 |
Natural air cooling |
AC90~264V |
±0.5% or less (at input AC90~264V 100% load) |
50~60Hz |
At 230V input: 1.0mA or less |
3 years |
15ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
EN61000-3-2,3 ClassA, CE,EN61000-4-2,3,4,5,6,8,11 |
Yes (110~150%, hiccup mode, automatic recovery) |
- | |
AK65W-SPL |
Available upon quote |
Yes (115~150%, shutdown, restart required) |
Yes (105~150%, hiccup mode, automatic recovery) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start) |
Yes (hiccup mode, automatic recovery) |
127 (width) x 76.2 (length) x 42 (height) |
65W |
Meet GB4943, UL60950, EN60950 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
DC5V/10A |
1 |
Natural air cooling |
AC85~264V |
±0.5% or less (input AC85~264V at 100% load) |
47~63Hz |
At 230V input: 1.0mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Meet GB9254, EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11 |
- | - |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
28.3hrs