All Categories
History
Response Rate
100.0%
Response Time
46.6hours
Product
Standard power supply large capacityHandling Company
Acon Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Overcurrent protection | Overvoltage protection | Withstand voltage | Rise time | Inrush current | Short circuit protection | Dimensions (mm) | Capacity | Safety standards | Operating temperature | Output voltage variable range | Output voltage/current | Number of outputs | Cooling method | Input voltage (V) | Input voltage | Input fluctuation | Input frequency | Input leakage current | Warranty period | Retention time | Storage temperature | EMC standard | Overheating protection |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AK240W-SF |
Available upon quote |
Yes (110~130%, shutdown, restart required) |
Yes (110~130%, shutdown, restart required) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start) |
Yes (blocked, restart required) |
199 (width) x 110 (vertical) x 50 (height) |
240W |
GB4943, UL60950, EN60950 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
DC7.5V/30A |
1 |
Natural air cooling |
AC85~132V/AC170~264V |
AC85~132/170~264V selected by switch |
±0.5% or less (at 100% load) |
47~63Hz |
At 230V input: 1.0mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
GB9254, EN55022 classB, EN55024,EN61000-3-2,3, |
- | |
AK240W-SV |
Available upon quote |
Yes (110~130%, cutoff, automatic recovery) |
Yes (110~130%, cutoff, automatic recovery) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start) |
Yes (blocking, automatic recovery) |
200 (width) x 110 (vertical) x 50 (height) |
240W |
- |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
DC100V/2.4A |
1 |
Natural air cooling |
AC85~132V/AC170~264V |
AC85~132/170~264V selected by switch |
±0.5% or less (at 100% load) |
47~63Hz |
At 230V input: 1.0mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
- | - | |
AK350W-SF |
Available upon quote | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
AC85~132V/AC170~264V |
- | - | - | - | - | - | - | - | - | |
AK500W-LSC |
Available upon quote |
Yes (105~130%, current limit, automatic recovery) |
Yes (115~150%, output cutoff, restart required) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
80ms typ. (at 100% load) |
115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start) |
Yes (current limit, automatic recovery) |
230 (width) x 127 (length) x 40.5 (height) |
500W |
Design meet UL508, UL62368-1, EN62368-1 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
- |
1 |
Cooling fan |
AC85~264V |
AC88~264V (DC120~370V) |
±0.5% or less (at input AC88~264V 100% load) |
47~63Hz |
At 230V input: 1.0mA or less |
3 years |
14ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Design meet GB9254 EN55032 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11, |
- | |
AK600W-SE |
Available upon quote |
Yes (110~130%, current limit, automatic recovery) |
Yes (115~150%, shutdown, restart required) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
At 115V input: 30A or less (at 25℃, cold start) |
Yes |
241 (width) x 124 (vertical) x 65 (height) |
600W |
Design refer to GB4943,UL60950,EN60950 |
-20 ~ +50℃ (humidity 20~93%) |
±10% |
- |
1 |
Cooling fan |
AC170~264V |
AC200V (170~264V) |
±0.5% or less (at 100% load) |
47~63Hz |
At 220V input: 1mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Design refer to GB9254, EN55022 classA |
Yes |
|
ATM600-F |
Available upon quote | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
AC100~240V |
- | - | - | - | - | - | - | - | - | |
AK1000W-SE |
Available upon quote |
Yes (105~130%, shutdown, restart required) |
Yes (115~150%, shutdown, restart required) |
Between AC3.0kV 1min (all inputs) and (all outputs) / Between AC1.5kV 1min (all inputs) and (ground [earth]/FG) / Between AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
400ms typ. (at 100% load) |
At 115V input: 30A or less, at 230V input: 60A or less (at 25℃, cold start) |
Yes |
278 (width) x 127 (length) x 63.5 (height) |
1,000W |
Design meet UL508, UL62368, EN62368 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
DC24V/42A |
1 |
Cooling fan |
AC170~264V with AC90~132V switching |
Compatible with 100V, 200V AC input (switch by shorting/opening jumper) |
±0.5% or less (at 100% load) |
47~63Hz |
At 230V input: 1.0mA or less |
3 years |
16ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Design meet GB9254, EN55032 Class B EN55024, EN61000-3-2,3 EN61000-4-2,3,4,5,6,8,11 |
- | |
AK1000W-SER |
Available upon quote |
Yes (105~130%, current limit, automatic recovery) |
Yes (115~150%, shutdown, restart required) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
400ms typ. (at 100% load) |
At 115V input: 30A or less, at 230V input: 60A or less (at 25℃, cold start) |
Yes |
278 (width) x 127 (length) x 63.5 (height) |
1,000W |
Design meet UL508, UL62368, EN62368 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
DC24V/42A |
1 |
Cooling fan |
AC170~264V with AC90~132V switching |
Compatible with 100V, 200V AC input (switch by shorting/opening jumper) |
±0.5% or less (at 100% load) |
47~63Hz |
At 230V input: 1.0mA or less |
3 years |
16ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Design meet GB9254, EN55032 Class B EN55024, EN61000-3-2,3 EN61000-4-2,3,4,5,6,8,11 |
- | |
AK1500W-S |
Available upon quote |
Yes (140% or more, current limit, automatic recovery) |
Yes (115~150%, shutdown, restart required) |
Between AC1.5kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/between AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
400ms typ. (at 100% load) |
At 220V input: 50A or less (at 25℃, cold start) |
Yes |
250 (width) x 160 (vertical) x 87 (height) |
1,500W (peak 2,000W) |
Design refer to GB4943, UL60950, EN60950 |
-20 ~ +50℃ (humidity 20~93%) |
±10% |
DC110V/13.6A (peak 18A) |
1 |
Cooling fan |
AC220V (AC170~264V) |
AC220V (170~264) |
±0.5% or less (at 100% load) |
47~63Hz |
At 230V input: 1.0mA or less |
3 years |
10ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Design refer to GB9254, EN55022 classA |
- |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
46.6hrs