All Categories
History
Response Rate
100.0%
Response Time
24.0hours
Relatively Fast Response
Product
Standard power supply smallHandling Company
Acon Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Overcurrent protection | Overvoltage protection | Withstand voltage | Rise time | Inrush current | Short circuit protection | Dimensions (mm) | Capacity | Safety standards | Operating temperature | Output voltage variable range | Output voltage/current | Number of outputs | Cooling method | Input voltage (V) | Input voltage | Input fluctuation | Input frequency | Input leakage current | Warranty period | Retention time | Storage temperature | EMC standard | Static load fluctuation | Static input variation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
AK15W-SSM |
Available upon quote |
Yes (105~150%, hiccup mode, automatic recovery) |
Yes (output cutoff, clamped with Zener diode) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 15A or less / 230V input: 30A or less (at 25℃, cold start) |
Yes (hiccup mode, automatic recovery) |
62.5 (width) x 51 (length) x 28 (height) |
15W |
Meet UL60950, EN60950, GB4943 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
DC5V/3A |
1 |
Natural air cooling |
AC88~264V |
AC88~264V (DC120~370V) |
- |
47~63Hz |
At 230V input: 0.50mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Meet EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,GB9254 |
±0.5% or less |
±0.5% or less (input AC85~264V at 100% load) |
![]() |
AK25W-SSM |
Available upon quote |
Yes (105~150%, hiccup mode, automatic recovery) |
Yes (output cutoff, clamped with Zener diode) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 15A or less / 230V input: 30A or less (at 25℃, cold start) |
Yes (hiccup mode, automatic recovery) |
78 (width) x 51 (vertical) x 28 (height) |
25W |
Meet UL60950, EN60950, GB4943 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
DC5V/5A |
1 |
Natural air cooling |
AC88~264V |
AC88~264V (DC120~370V) |
- |
47~63Hz |
At 230V input: 0.50mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Meet EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,GB9254 |
±0.5% or less |
±0.5% or less (at 100% load) |
![]() |
AK35W-SSM |
Available upon quote |
Yes (105~150%, hiccup mode, automatic recovery) |
Yes (115~150%, output cut off, reset by input input again) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start) |
Yes (hiccup mode, automatic recovery) |
98.5 (width) x 82 (length) x 35 (height) |
35W |
Meet UL60950, EN60950, GB4943 |
-20 ~ +70℃ (humidity 20~93%) |
±10% |
DC5V/7A |
1 |
Natural air cooling |
AC88~264V |
AC88~264V (DC120~370V) |
- |
47~63Hz |
At 230V input: 0.50mA or less |
3 years |
20ms typ. (at 100% load) |
-20 ~ +85℃ (humidity 20~95%) |
Meet EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,2,3,4,5,6,8,11,GB9254 |
±0.5% or less |
±0.5% or less (at 100% load) |
![]() |
AK50W-SSM |
Available upon quote | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
AC88~264V |
- | - | - | - | - | - | - | - | - | - |
![]() |
AK100W-SSM |
Available upon quote | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
AC88~264V |
- | - | - | - | - | - | - | - | - | - |
![]() |
AK100W-SMF |
Available upon quote | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
AC85~132V/AC170~264V |
- | - | - | - | - | - | - | - | - | - |
![]() |
AK150W-SMF |
Available upon quote |
Yes (110~130%, shutdown, restart required) |
Yes (110~130%, shutdown, restart required) |
Between AC3.0kV 1min (all inputs) and (all outputs)/between AC1.5kV 1min (all inputs) and (ground [earth]/FG)/AC0.5kV 1min (all outputs) and (ground [earth]/FG) ) between |
50ms typ. (at 100% load) |
115V input: 20A or less / 230V input: 40A or less (at 25℃, cold start) |
Yes (blocked, restart required) |
199 (width) x 98 (vertical) x 39 (height) |
150W |
Meet UL60950, EN60950, GB4943 |
-20~+70℃ |
±10% |
DC5V/25A |
1 |
Natural air cooling |
AC85~132V/AC170~264V |
AC85~132/170~264V selected by switch |
±0.5% or less (at 100% load) |
47~63Hz |
At 230V input: 0.70mA or less |
3 years |
20ms typ. (at 100% load) |
-20~+85℃ |
Meet EN55022 classB, EN55024,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,GB9254 |
- | - |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
24.0hrs