All Categories
History
Product
Voltage current phase difference meter CVE-32Handling Company
CB Engineering Co., Ltd.Image | Part Number | Price (excluding tax) | Power supply | Current measurement Display digits | Current measurement accuracy | Current measurement measurement range | Current measurement input terminal | Voltage measurement (standard/comparison) Number of display digits | Voltage measurement (standard/comparison) accuracy | Voltage measurement (standard/comparison) Measurement range | Voltage measurement (reference/comparison) input terminal | Power measurement calculation formula | Potentiometric hardness | Potential difference measurement measurement range | Potential difference measurement Significant figures | Weight | Phase wire system | Measurement frequency | External dimensions | Phase angle measurement error | Phase angle measurement measurement range | Phase angle measurement measurement conditions | Phase angle measurement resolution | Phase difference measurement error | Phase difference measurement measurement range | Phase difference measurement measurement conditions | Phase difference measurement resolution | Format | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CVE-32 |
Available upon quote |
AC100V ±10% 50/60Hz |
4 significant figures (automatic switching of decimal digits, up to 4 digits after the decimal point) |
±1.0% of RDG / ±1.0% of RDG / ±1.0% of RDG (0.003A or more) |
0~0.05A / 0.05~1A / 1~20A (automatic switching) |
R, S, T, N (4 terminals, terminal or clamp) |
4 significant figures (automatic switching of decimal digits, up to 4 digits after the decimal point) |
Phase voltage: ±0.5% of RDG / ±0.5% of RDG |
Phase voltage: 0~20V/20~150V |
R, S, T, N (4 terminals, terminal) |
Active power = phase voltage x phase current x cosθ |
±0.5% of RDG / ±0.5% of RDG (1V or more) |
0~20V / 20~250V (automatic switching) |
4 digits (automatic switching of decimal digits, up to 4 digits after the decimal point) |
11kg |
Single-phase 2-wire (1P2W), Single-phase 3-wire (1P3W) |
50Hz / 60Hz (manual switching) |
450 (W) ×290 (H) ×280 (D) (Unit: mm) |
Voltage: ±0.5° / Current: ±1.0° (voltage 1V or more, current 0.003A or more) |
0.0~359.9° (lag phase) |
The phase reference voltage must meet the following conditions. |
0.1° |
±0.5° (Two phase voltages to be measured are each 1V or more) |
0.0~359.9° (lag phase) |
The two phase voltages to be measured for phase difference must each be 0.2V or more and 160V or less (potential difference is irrelevant) |
0.1° |
CVE-32 |
4 clamp sensors |
Reviews shown here are reviews of companies.