All Categories

History

Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-XA-4400Ⅱ-J4T
Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Tohke Seiki Co., Ltd.

Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series
Tohke Seiki Co., Ltd.

Tohke Seiki Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

143.6hours


About This Product

It can be used at any work site to prevent accidents such as oxygen deficiency, explosions, and poisoning. Easy operation with one button. Prevents incorrect operation. The main body is compact and does not get in the way of your work. Features

■Warning with loud alarm, lamp, and vibration

Warning lamp, loud alarm (over 95db/30cm), and vibration will notify you of the alarm.

■Large display screen

Large LCD screen (with backlight) for easy viewing of concentration display.

■Waterproof and dustproof construction that is resistant to water and protection equivalent to IP65

It has a dustproof and waterproof structure that prevents dust and water from entering the inside of the device. It will not break even if used in rainy weather or near a water source.

■Intrinsically safe explosion-proof structure Ex ia ⅡB T3 X

Ex ia IIB T3 X can be used in hydrogen and acetylene atmosphere environments with strict explosion-proof standards.

■Main functions

Self-diagnosis (sensor abnormality), automatic zero adjustment, battery level display, peak hold, LCD backlight, buzzer stop at gas alarm, time/temperature display, alarm test, buzzer volume setting, buzzer silence, long life mode, data Logging (data collection requires the optional logging data collection set), Pump unit (P-400-J): Lamp display (Battery level (power supply): 2 green, Trouble: 1 yellow), Trouble display (Low battery level, low flow rate (blockage), abnormal motor current)

■Options

Leather case, neck strap, protective cover, belt clip, arm belt, safety belt adapter, alligator clip, logging data collection set, pump unit set, simple inspection jig, Tedra bag set, hydrogen sulfide gas generation kit for inspection, dry battery unit , rechargeable battery unit, charger, AC adapter *Other product numbers are available.

  • Product

    Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series

Share this product


470+ people viewing

Last viewed: 1 hour ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Power supply Explosion-proof structure Continuous use time Alarm set value (TWA/STEL) Alarm set value (1st stage/2nd stage) Alarm method Display method Display resolution Detection range (service range) Gas to be detected Detection principle External dimensions/mass Protection class Operating temperature and humidity range Gas sampling method Accessories
Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J4T

XA-4400Ⅱ-J4T

Available upon quote

Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic)

Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3

Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF

TWA:10.0ppm STEL:15.0ppm
TWA:25ppm STEL:300ppm

1st stage: 10% LEL 2nd stage: 30% LEL
1st stage: 5.0ppm 2nd stage: 15.0ppm
1st stage: 50ppm 2nd stage: 150ppm
1st stage: 19.5vol% 2nd stage: 18.0vol%

Buzzer sound, red lamp flashing, vibration, LCD display (self-holding)

LCD display

1%LEL
0~35ppm:0.1ppm 35~150ppm:0.5ppm
0~350ppm:1ppm 350~2000ppm:5ppm
0.1vol%

0~100%LEL
0~30.0ppm
0~300ppm
0~25.0vol%

Isobutane (flammable gas)
hydrogen sulfide
carbon monoxide
oxygen

Catalytic combustion type
Constant potential electrolysis type
galvanic battery type

W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries)

Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)

-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation)

Diffusion type

Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual

Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J3T-1

XA-4400Ⅱ-J3T-1

Available upon quote

Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic)

Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3

Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF

TWA:10.0ppm STEL:15.0ppm

1st stage: 10% LEL 2nd stage: 30% LEL
1st stage: 5.0ppm 2nd stage: 15.0ppm
1st stage: 19.5vol% 2nd stage: 18.0vol%

Buzzer sound, red lamp flashing, vibration, LCD display (self-holding)

LCD display

1%LEL
0~35ppm:0.1ppm 35~150ppm:0.5ppm
0.1vol%

0~100%LEL
0~30.0ppm
0~25.0vol%

Isobutane (flammable gas)
hydrogen sulfide
oxygen

Catalytic combustion type
Constant potential electrolysis type
galvanic battery type

W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries)

Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)

-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation)

Diffusion type

Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual

Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J3T-2

XA-4400Ⅱ-J3T-2

Available upon quote

Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic)

Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3

Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF

TWA:25ppm STEL:300ppm

1st stage: 10% LEL 2nd stage: 30% LEL
1st stage: 50ppm 2nd stage: 150ppm
1st stage: 19.5vol% 2nd stage: 18.0vol%

Buzzer sound, red lamp flashing, vibration, LCD display (self-holding)

LCD display

1%LEL
0~350ppm:1ppm 350~2000ppm:5ppm
0.1vol%

0~100%LEL
0~300ppm
0~25.0vol%

Isobutane (flammable gas)
carbon monoxide
oxygen

Catalytic combustion type
Constant potential electrolysis type
galvanic battery type

W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries)

Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)

-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation)

Diffusion type

Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual

Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J3T-3

XA-4400Ⅱ-J3T-3

Available upon quote

Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic)

Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3

Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF

TWA:10.0ppm STEL:15.0ppm
TWA:25ppm STEL:300ppm

1st stage: 10% LEL 2nd stage: 30% LEL
1st stage: 5.0ppm 2nd stage: 15.0ppm
1st stage: 50ppm 2nd stage: 150ppm

Buzzer sound, red lamp flashing, vibration, LCD display (self-holding)

LCD display

1%LEL
0~35ppm:0.1ppm 35~150ppm:0.5ppm
0~350ppm:1ppm 350~2000ppm:5ppm

0~100%LEL
0~30.0ppm
0~300ppm

Isobutane (flammable gas)
hydrogen sulfide
carbon monoxide

Catalytic combustion type
Constant potential electrolysis type

W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries)

Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)

-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation)

Diffusion type

Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual

Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J3T-4

XA-4400Ⅱ-J3T-4

Available upon quote

Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic)

Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3

Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF

TWA:10.0ppm STEL:15.0ppm
TWA:25ppm STEL:300ppm

1st stage: 5.0ppm 2nd stage: 15.0ppm
1st stage: 50ppm 2nd stage: 150ppm
1st stage: 19.5vol% 2nd stage: 18.0vol%

Buzzer sound, red lamp flashing, vibration, LCD display (self-holding)

LCD display

0~35ppm:0.1ppm 35~150ppm:0.5ppm
0~350ppm:1ppm 350~2000ppm:5ppm
0.1vol%

0~30.0ppm
0~300ppm
0~25.0vol%

Hydrogen sulfide
carbon monoxide
oxygen

Constant potential electrolysis type
galvanic battery type

W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries)

Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)

-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation)

Diffusion type

Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual

Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J2T-1

XA-4400Ⅱ-J2T-1

Available upon quote

Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic)

Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3

Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF

-

1st stage: 10% LEL 2nd stage: 30% LEL
1st stage: 19.5vol% 2nd stage: 18.0vol%

Buzzer sound, red lamp flashing, vibration, LCD display (self-holding)

LCD display

1%LEL
0.1vol%

0~100%LEL
0~25.0vol%

Isobutane (flammable gas)
oxygen

Catalytic combustion type
galvanic battery type

W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries)

Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)

-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation)

Diffusion type

Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual

Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J2T-2

XA-4400Ⅱ-J2T-2

Available upon quote

Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic)

Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3

Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF

TWA:10.0ppm STEL:15.0ppm

1st stage: 10% LEL 2nd stage: 30% LEL
1st stage: 5.0ppm 2nd stage: 15.0ppm

Buzzer sound, red lamp flashing, vibration, LCD display (self-holding)

LCD display

1%LEL
0~35ppm:0.1ppm 35~150ppm:0.5ppm

0~100%LEL
0~30.0ppm

Isobutane (flammable gas)
hydrogen sulfide

Catalytic combustion type
Constant potential electrolysis type

W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries)

Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)

-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation)

Diffusion type

Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual

Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J2T-3

XA-4400Ⅱ-J2T-3

Available upon quote

Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic)

Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3

Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF

TWA:25ppm STEL:300ppm

1st stage: 10% LEL 2nd stage: 30% LEL
1st stage: 50ppm 2nd stage: 150ppm

Buzzer sound, red lamp flashing, vibration, LCD display (self-holding)

LCD display

1%LEL
0~350ppm:1ppm 350~2000ppm:5ppm

0~100%LEL
0~300ppm

Isobutane (flammable gas)
carbon monoxide

Catalytic combustion type
Constant potential electrolysis type

W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries)

Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)

-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation)

Diffusion type

Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual

Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J2T-4

XA-4400Ⅱ-J2T-4

Available upon quote

Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic)

Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3

Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF

TWA:10.0ppm STEL:15.0ppm

1st stage: 5.0ppm 2nd stage: 15.0ppm
1st stage: 19.5vol% 2nd stage: 18.0vol%

Buzzer sound, red lamp flashing, vibration, LCD display (self-holding)

LCD display

0~35ppm:0.1ppm 35~150ppm:0.5ppm
0.1vol%

0~30.0ppm
0~25.0vol%

Hydrogen sulfide
oxygen

Constant potential electrolysis type
galvanic battery type

W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries)

Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)

-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation)

Diffusion type

Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual

Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J2T-5

XA-4400Ⅱ-J2T-5

Available upon quote

Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic)

Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3

Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF

TWA:25ppm STEL:300ppm

1st stage: 50ppm 2nd stage: 150ppm
1st stage: 19.5vol% 2nd stage: 18.0vol%

Buzzer sound, red lamp flashing, vibration, LCD display (self-holding)

LCD display

0~350ppm:1ppm 350~2000ppm:5ppm
0.1vol%

0~300ppm
0~25.0vol%

Carbon monoxide
oxygen

Constant potential electrolysis type
galvanic battery type

W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries)

Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)

-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation)

Diffusion type

Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Gas Detectors Products

Other products of Tohke Seiki Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Tohke Seiki Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

143.6hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree