Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J seriesHandling Company
Tohke Seiki Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Accessories | Alarm method | Alarm set value (1st stage/2nd stage) | Alarm set value (TWA/STEL) | Continuous use time | Detection principle | Detection range (service range) | Display method | Display resolution | Explosion-proof structure | External dimensions/mass | Gas sampling method | Gas to be detected | Operating temperature and humidity range | Power supply | Protection class |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XA-4400Ⅱ-J4T |
Available upon quote | Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual | Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) |
1st stage: 10% LEL 2nd stage: 30% LEL 1st stage: 5.0ppm 2nd stage: 15.0ppm 1st stage: 50ppm 2nd stage: 150ppm 1st stage: 19.5vol% 2nd stage: 18.0vol% |
TWA:10.0ppm STEL:15.0ppm TWA:25ppm STEL:300ppm |
Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF |
Catalytic combustion type Constant potential electrolysis type galvanic battery type |
0~100%LEL 0~30.0ppm 0~300ppm 0~25.0vol% |
LCD display |
1%LEL 0~35ppm:0.1ppm 35~150ppm:0.5ppm 0~350ppm:1ppm 350~2000ppm:5ppm 0.1vol% |
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 | W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) | Diffusion type |
Isobutane (flammable gas) hydrogen sulfide carbon monoxide oxygen |
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) | Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) | Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports) | |
XA-4400Ⅱ-J3T-1 |
Available upon quote | Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual | Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) |
1st stage: 10% LEL 2nd stage: 30% LEL 1st stage: 5.0ppm 2nd stage: 15.0ppm 1st stage: 19.5vol% 2nd stage: 18.0vol% |
TWA:10.0ppm STEL:15.0ppm | Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF |
Catalytic combustion type Constant potential electrolysis type galvanic battery type |
0~100%LEL 0~30.0ppm 0~25.0vol% |
LCD display |
1%LEL 0~35ppm:0.1ppm 35~150ppm:0.5ppm 0.1vol% |
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 | W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) | Diffusion type |
Isobutane (flammable gas) hydrogen sulfide oxygen |
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) | Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) | Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports) | |
XA-4400Ⅱ-J3T-2 |
Available upon quote | Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual | Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) |
1st stage: 10% LEL 2nd stage: 30% LEL 1st stage: 50ppm 2nd stage: 150ppm 1st stage: 19.5vol% 2nd stage: 18.0vol% |
TWA:25ppm STEL:300ppm | Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF |
Catalytic combustion type Constant potential electrolysis type galvanic battery type |
0~100%LEL 0~300ppm 0~25.0vol% |
LCD display |
1%LEL 0~350ppm:1ppm 350~2000ppm:5ppm 0.1vol% |
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 | W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) | Diffusion type |
Isobutane (flammable gas) carbon monoxide oxygen |
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) | Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) | Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports) | |
XA-4400Ⅱ-J3T-3 |
Available upon quote | Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual | Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) |
1st stage: 10% LEL 2nd stage: 30% LEL 1st stage: 5.0ppm 2nd stage: 15.0ppm 1st stage: 50ppm 2nd stage: 150ppm |
TWA:10.0ppm STEL:15.0ppm TWA:25ppm STEL:300ppm |
Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF |
Catalytic combustion type Constant potential electrolysis type |
0~100%LEL 0~30.0ppm 0~300ppm |
LCD display |
1%LEL 0~35ppm:0.1ppm 35~150ppm:0.5ppm 0~350ppm:1ppm 350~2000ppm:5ppm |
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 | W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) | Diffusion type |
Isobutane (flammable gas) hydrogen sulfide carbon monoxide |
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) | Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) | Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports) | |
XA-4400Ⅱ-J3T-4 |
Available upon quote | Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual | Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) |
1st stage: 5.0ppm 2nd stage: 15.0ppm 1st stage: 50ppm 2nd stage: 150ppm 1st stage: 19.5vol% 2nd stage: 18.0vol% |
TWA:10.0ppm STEL:15.0ppm TWA:25ppm STEL:300ppm |
Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF |
Constant potential electrolysis type galvanic battery type |
0~30.0ppm 0~300ppm 0~25.0vol% |
LCD display |
0~35ppm:0.1ppm 35~150ppm:0.5ppm 0~350ppm:1ppm 350~2000ppm:5ppm 0.1vol% |
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 | W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) | Diffusion type |
Hydrogen sulfide carbon monoxide oxygen |
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) | Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) | Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports) | |
XA-4400Ⅱ-J2T-1 |
Available upon quote | Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual | Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) |
1st stage: 10% LEL 2nd stage: 30% LEL 1st stage: 19.5vol% 2nd stage: 18.0vol% |
- | Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF |
Catalytic combustion type galvanic battery type |
0~100%LEL 0~25.0vol% |
LCD display |
1%LEL 0.1vol% |
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 | W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) | Diffusion type |
Isobutane (flammable gas) oxygen |
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) | Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) | Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports) | |
XA-4400Ⅱ-J2T-2 |
Available upon quote | Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual | Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) |
1st stage: 10% LEL 2nd stage: 30% LEL 1st stage: 5.0ppm 2nd stage: 15.0ppm |
TWA:10.0ppm STEL:15.0ppm | Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF |
Catalytic combustion type Constant potential electrolysis type |
0~100%LEL 0~30.0ppm |
LCD display |
1%LEL 0~35ppm:0.1ppm 35~150ppm:0.5ppm |
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 | W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) | Diffusion type |
Isobutane (flammable gas) hydrogen sulfide |
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) | Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) | Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports) | |
XA-4400Ⅱ-J2T-3 |
Available upon quote | Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual | Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) |
1st stage: 10% LEL 2nd stage: 30% LEL 1st stage: 50ppm 2nd stage: 150ppm |
TWA:25ppm STEL:300ppm | Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF |
Catalytic combustion type Constant potential electrolysis type |
0~100%LEL 0~300ppm |
LCD display |
1%LEL 0~350ppm:1ppm 350~2000ppm:5ppm |
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 | W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) | Diffusion type |
Isobutane (flammable gas) carbon monoxide |
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) | Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) | Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports) | |
XA-4400Ⅱ-J2T-4 |
Available upon quote | Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual | Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) |
1st stage: 5.0ppm 2nd stage: 15.0ppm 1st stage: 19.5vol% 2nd stage: 18.0vol% |
TWA:10.0ppm STEL:15.0ppm | Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF |
Constant potential electrolysis type galvanic battery type |
0~30.0ppm 0~25.0vol% |
LCD display |
0~35ppm:0.1ppm 35~150ppm:0.5ppm 0.1vol% |
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 | W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) | Diffusion type |
Hydrogen sulfide oxygen |
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) | Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) | Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports) | |
XA-4400Ⅱ-J2T-5 |
Available upon quote | Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual | Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) |
1st stage: 50ppm 2nd stage: 150ppm 1st stage: 19.5vol% 2nd stage: 18.0vol% |
TWA:25ppm STEL:300ppm | Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF |
Constant potential electrolysis type galvanic battery type |
0~300ppm 0~25.0vol% |
LCD display |
0~350ppm:1ppm 350~2000ppm:5ppm 0.1vol% |
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 | W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) | Diffusion type |
Carbon monoxide oxygen |
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) | Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) | Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports) |