Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-XA-4400Ⅱ-J4T
Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Tohke Seiki Co., Ltd.

Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series
Tohke Seiki Co., Ltd.


About This Product

It can be used at any work site to prevent accidents such as oxygen deficiency, explosions, and poisoning. Easy operation with one button. Prevents incorrect operation. The main body is compact and does not get in the way of your work. Features ■Warning with loud alarm, lamp, and vibration Warning lamp, loud alarm (over 95db/30cm), and vibration will notify you of the alarm. ■Large display screen Large LCD screen (with backlight) for easy viewing of concentration display. ■Waterproof and dustproof construction that is resistant to water and protection equivalent to IP65 It has a dustproof and waterproof structure that prevents dust and water from entering the inside of the device. It will not break even if used in rainy weather or near a water source. ■Intrinsically safe explosion-proof structure Ex ia ⅡB T3 X Ex ia IIB T3 X can be used in hydrogen and acetylene atmosphere environments with strict explosion-proof standards. ■Main functions Self-diagnosis (sensor abnormality), automatic zero adjustment, battery level display, peak hold, LCD backlight, buzzer stop at gas alarm, time/temperature display, alarm test, buzzer volume setting, buzzer silence, long life mode, data Logging (data collection requires the optional logging data collection set), Pump unit (P-400-J): Lamp display (Battery level (power supply): 2 green, Trouble: 1 yellow), Trouble display (Low battery level, low flow rate (blockage), abnormal motor current) ■Options Leather case, neck strap, protective cover, belt clip, arm belt, safety belt adapter, alligator clip, logging data collection set, pump unit set, simple inspection jig, Tedra bag set, hydrogen sulfide gas generation kit for inspection, dry battery unit , rechargeable battery unit, charger, AC adapter *Other product numbers are available.

  • Product

    Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series

Share this product


270+ people viewing

Last viewed: 21 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Accessories Alarm method Alarm set value (1st stage/2nd stage) Alarm set value (TWA/STEL) Continuous use time Detection principle Detection range (service range) Display method Display resolution Explosion-proof structure External dimensions/mass Gas sampling method Gas to be detected Operating temperature and humidity range Power supply Protection class
Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J4T

XA-4400Ⅱ-J4T

Available upon quote Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) 1st stage: 10% LEL 2nd stage: 30% LEL
1st stage: 5.0ppm 2nd stage: 15.0ppm
1st stage: 50ppm 2nd stage: 150ppm
1st stage: 19.5vol% 2nd stage: 18.0vol%
TWA:10.0ppm STEL:15.0ppm
TWA:25ppm STEL:300ppm
Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF Catalytic combustion type
Constant potential electrolysis type
galvanic battery type
0~100%LEL
0~30.0ppm
0~300ppm
0~25.0vol%
LCD display 1%LEL
0~35ppm:0.1ppm 35~150ppm:0.5ppm
0~350ppm:1ppm 350~2000ppm:5ppm
0.1vol%
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) Diffusion type Isobutane (flammable gas)
hydrogen sulfide
carbon monoxide
oxygen
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)
Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J3T-1

XA-4400Ⅱ-J3T-1

Available upon quote Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) 1st stage: 10% LEL 2nd stage: 30% LEL
1st stage: 5.0ppm 2nd stage: 15.0ppm
1st stage: 19.5vol% 2nd stage: 18.0vol%
TWA:10.0ppm STEL:15.0ppm Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF Catalytic combustion type
Constant potential electrolysis type
galvanic battery type
0~100%LEL
0~30.0ppm
0~25.0vol%
LCD display 1%LEL
0~35ppm:0.1ppm 35~150ppm:0.5ppm
0.1vol%
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) Diffusion type Isobutane (flammable gas)
hydrogen sulfide
oxygen
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)
Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J3T-2

XA-4400Ⅱ-J3T-2

Available upon quote Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) 1st stage: 10% LEL 2nd stage: 30% LEL
1st stage: 50ppm 2nd stage: 150ppm
1st stage: 19.5vol% 2nd stage: 18.0vol%
TWA:25ppm STEL:300ppm Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF Catalytic combustion type
Constant potential electrolysis type
galvanic battery type
0~100%LEL
0~300ppm
0~25.0vol%
LCD display 1%LEL
0~350ppm:1ppm 350~2000ppm:5ppm
0.1vol%
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) Diffusion type Isobutane (flammable gas)
carbon monoxide
oxygen
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)
Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J3T-3

XA-4400Ⅱ-J3T-3

Available upon quote Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) 1st stage: 10% LEL 2nd stage: 30% LEL
1st stage: 5.0ppm 2nd stage: 15.0ppm
1st stage: 50ppm 2nd stage: 150ppm
TWA:10.0ppm STEL:15.0ppm
TWA:25ppm STEL:300ppm
Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF Catalytic combustion type
Constant potential electrolysis type
0~100%LEL
0~30.0ppm
0~300ppm
LCD display 1%LEL
0~35ppm:0.1ppm 35~150ppm:0.5ppm
0~350ppm:1ppm 350~2000ppm:5ppm
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) Diffusion type Isobutane (flammable gas)
hydrogen sulfide
carbon monoxide
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)
Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J3T-4

XA-4400Ⅱ-J3T-4

Available upon quote Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) 1st stage: 5.0ppm 2nd stage: 15.0ppm
1st stage: 50ppm 2nd stage: 150ppm
1st stage: 19.5vol% 2nd stage: 18.0vol%
TWA:10.0ppm STEL:15.0ppm
TWA:25ppm STEL:300ppm
Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF Constant potential electrolysis type
galvanic battery type
0~30.0ppm
0~300ppm
0~25.0vol%
LCD display 0~35ppm:0.1ppm 35~150ppm:0.5ppm
0~350ppm:1ppm 350~2000ppm:5ppm
0.1vol%
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) Diffusion type Hydrogen sulfide
carbon monoxide
oxygen
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)
Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J2T-1

XA-4400Ⅱ-J2T-1

Available upon quote Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) 1st stage: 10% LEL 2nd stage: 30% LEL
1st stage: 19.5vol% 2nd stage: 18.0vol%
- Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF Catalytic combustion type
galvanic battery type
0~100%LEL
0~25.0vol%
LCD display 1%LEL
0.1vol%
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) Diffusion type Isobutane (flammable gas)
oxygen
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)
Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J2T-2

XA-4400Ⅱ-J2T-2

Available upon quote Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) 1st stage: 10% LEL 2nd stage: 30% LEL
1st stage: 5.0ppm 2nd stage: 15.0ppm
TWA:10.0ppm STEL:15.0ppm Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF Catalytic combustion type
Constant potential electrolysis type
0~100%LEL
0~30.0ppm
LCD display 1%LEL
0~35ppm:0.1ppm 35~150ppm:0.5ppm
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) Diffusion type Isobutane (flammable gas)
hydrogen sulfide
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)
Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J2T-3

XA-4400Ⅱ-J2T-3

Available upon quote Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) 1st stage: 10% LEL 2nd stage: 30% LEL
1st stage: 50ppm 2nd stage: 150ppm
TWA:25ppm STEL:300ppm Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF Catalytic combustion type
Constant potential electrolysis type
0~100%LEL
0~300ppm
LCD display 1%LEL
0~350ppm:1ppm 350~2000ppm:5ppm
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) Diffusion type Isobutane (flammable gas)
carbon monoxide
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)
Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J2T-4

XA-4400Ⅱ-J2T-4

Available upon quote Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) 1st stage: 5.0ppm 2nd stage: 15.0ppm
1st stage: 19.5vol% 2nd stage: 18.0vol%
TWA:10.0ppm STEL:15.0ppm Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF Constant potential electrolysis type
galvanic battery type
0~30.0ppm
0~25.0vol%
LCD display 0~35ppm:0.1ppm 35~150ppm:0.5ppm
0.1vol%
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) Diffusion type Hydrogen sulfide
oxygen
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)
Multi-gas detector (4 components) Four-component gas detector XA-4400Ⅱ-J series-Part Number-XA-4400Ⅱ-J2T-5

XA-4400Ⅱ-J2T-5

Available upon quote Safety pin adapter, alkaline battery or nickel metal hydride battery, 8 filter elements, flammable gas sensor filter, carbon monoxide filter, gas concentration conversion correction coefficient table, gas calibration procedure manual Buzzer sound, red lamp flashing, vibration, LCD display (self-holding) 1st stage: 50ppm 2nd stage: 150ppm
1st stage: 19.5vol% 2nd stage: 18.0vol%
TWA:25ppm STEL:300ppm Approximately 40 hours when in long life mode, approximately 20 hours when long life mode is OFF When using pump unit set: Approximately 30 hours when in long life mode, approximately 20 hours when long life mode is OFF Constant potential electrolysis type
galvanic battery type
0~300ppm
0~25.0vol%
LCD display 0~350ppm:1ppm 350~2000ppm:5ppm
0.1vol%
Ex ia ⅡC T3 X (intrinsically safe explosion-proof construction) When using pump unit set: Ex ia ⅡC T3 W70×H73×D26mm (excluding protrusions/approx. 130g (excluding batteries) When using pump unit set: W123×H118×D40mm (excluding protrusions)/approx. 365g (excluding batteries) Diffusion type Carbon monoxide
oxygen
-20~+50℃ 30~85%RH (However, no condensation) When using pump unit set: -10~+40℃ 30~85%RH (However, no condensation) Dry battery unit: 1 AAA alkaline battery (manufactured by Panasonic) Rechargeable battery unit: 1 nickel metal hydride battery (manufactured by FDK) Pump unit set: 1 AA alkaline battery (manufactured by Panasonic) Equivalent to IP65/IP67 When using pump unit set: Equivalent to IP65 (excluding intake and exhaust ports)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Tohke Seiki Co., Ltd.


View more products of Tohke Seiki Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree