A multi-purpose device that can accept a variety of sensors. Noise-resistant and accurate 2-channel simultaneous sampling

■For customers like this

・Those who feel troublesome about installing and expanding data logger devices for each sensor. ・People who want to have a wide range of options for external output, such as LAN communication or USB ・People who have put off adopting conventional data logger devices because they are too expensive.

■Characteristics/Introduction effects

・Maximum sampling rate of 10μs. 2 channels simultaneous sampling (LAN communication logging) - Analog input supports isolation between channels. It is less susceptible to interference between signal sources, is resistant to noise, and enables accurate measurements. Isolation is also provided between sensors. ・Real-time data communication to host PC via LAN communication (Industrial Ethernet is also available as an option) ・High-speed transfer using USB3.0. Storage capacity allows for high resolution of high-speed signals. Continuous logging for long periods of time is possible ・Input method selection for 2 channels can be selected and confirmed from the simple LCD screen

■Benefits/Value to society

・Achieve low cost with multiple input/output devices ・Input method can be selected on the LCD screen ・Improve productivity with flexible support

  • Product

    Noise-resistant and accurate 2-channel simultaneous sampling data logger device Analizister

Share this product


100+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Noise-resistant and accurate 2-channel simultaneous sampling data logger device Analizister

Image Part Number Price (excluding tax) Power supply voltage Display Shockproof Measurement channel Power consumption External input/output Alarm input External dimensions Input terminal shape Input method Protection class Operating temperature Use vibration Power output for sensor Sampling period PC_I/F type PC_I/F Ethernet 2 PC_I/F Ethernet 1 PC_I/F USB A/D resolution Accessories
Noise-resistant and accurate 2-channel simultaneous sampling data logger device Analizister-Part Number-Analizister

Analizister

Available upon quote

AC100~240V/50~60Hz

Equipped with 2.7-inch WVGA monochrome LCD (simple status monitor, IP settings, etc. possible)

5G

2 channel isolation

50VA or less

5V open collector output supported for each channel (15mA)

180 (W) ×70 (H) ×180 (D)

Screw type terminal block connector socket: XW4B-08B1-H1 (manufactured by OMRON)

Analog input: Bipolar (±5.12V, ±2.56V) / Unipolar (10.24V, 5.12V) 4~20mA current 3-wire system compatible (250Ω) 4~20mA current 2-wire system compatible (250Ω)

IP5X

-5℃~50℃

1G or less

Fixed output 24V (0.1A) Variable output 5V~15V (0.1A)

Maximum 100KHz (10μs)

LAN (100BASE-TX) ×1/USB3.0×1

Industrial Ethernet compatible (CCLINK-IE_BASIC, MODBUS/TCP, EtherNet/IP) *Optional

Real-time UDP/IP communication to PC (data file format is binary)

PC-less automatic logging supported

16bit

AC cable 3P 1.8m

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Data Loggers Products

Other products of Super Factory Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Super Factory Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree