Product
Miniature signal relay EC2 seriesHandling Company
EM Device Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Coil temperature rise | Contact configuration | Contact material | Contact resistance | Driving performance no load | Driving performance with load | Impact resistance and durability | Insulation resistance | Mass | Maximum carrying current | Maximum switching capacity | Maximum switching current | Maximum switching voltage | Minimum switching capacity | Operating temperature range | Operating time Set time | Rated power consumption | Rated power consumption High insulation | Recovery time Reset time | Shock resistance Malfunction | Vibration resistance Durability | Vibration resistance Malfunction | Withstand voltage Between open contacts | Withstand voltage between adjacent contacts | Withstand voltage between coil contacts |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
EC2-3NU |
Available upon quote | Approx. 18℃/140mW (when rated voltage is applied) | 2c (2 transfers) | Ag alloy + Au alloy (surface layer) | 75mΩ (Initial value, MAX.) | 100 million times or more (non-latching type) /10 million times or more (latching type) |
50VDC, 0.1A resistive load 1 million times or more at 85℃, driving frequency: 5Hz 10VDC, 10mA resistive load 1 million times or more at 85℃, driving frequency: 2Hz |
980m/s2 | 1,000MΩ or more (500VDC, normal temperature and humidity) | Approximately 1.9g | 2A | 30W, 125VA (resistive load) | 2A | 220VDC, 250VAC | 10mVDC, 10μA | -40~+85℃ (No freezing) | Approx. 2ms [Approx. 2ms] (When applying rated voltage, not including bounce) |
Non-latching type: 140mW (200mW for 24V) Latching type: 1 winding type 100mW, 2 winding type 140mW |
Non-latching type: 200mW (230mW for 24V) 1 winding latching type: 100mW~170mW, (3~9V is 100mW) |
Approx. 1ms [Approx. 2ms] (When applying rated voltage, does not include bounce, no diode) | 735m/s2 | 10~55Hz, double amplitude 5mm | 10~55Hz, double amplitude 3mm | 1,000VAC for 1 minute, surge 1,500V (10×160μs Fcc Part 68) | 1,000VAC for 1 minute, surge 1,500V (10×160μs Fcc Part 68) |
1,500VAC for 1 minute (1,000V for 2-winding latching type) Surge 2,500V (2×10μs) (2-winding latching type: 1,500V, 10×160μs) |