Suction type stationary gas detector with built-in suction pump Midas-MIDAS-E-NH3
Suction type stationary gas detector with built-in suction pump Midas-Ichinen Manufacturing Co., Ltd.

Suction type stationary gas detector with built-in suction pump Midas
Ichinen Manufacturing Co., Ltd.


About This Product

■Features ・Compatible with over 35 types of gas ・2 year warranty sensor - Factory calibrated sensor cartridge can be easily replaced ・Easy operation, large backlit LCD display ・Factory calibrated sensor cartridge to reduce on-site gas calibration ・Equipped with event reporting function ・Suction pump system capable of sampling up to 30m (2 year lifespan) ・Power can also be supplied via Power over Ethernet (PoE) communication. - Obtained CE mark for complete electromagnetic immunity against radio frequency interference ・Event logging function that allows you to view sensor history ・Adopts an excellent sensor with high selectivity to avoid false alarms caused by interfering gases

  • Product

    Suction type stationary gas detector with built-in suction pump Midas

Share this product


490+ people viewing

Last viewed: 6 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Suction type stationary gas detector with built-in suction pump Midas

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Alarm output (3 types relay) Analog output Certification Electrical Standards Certification Environmental standards Certification European Standard Data communication Detection gas Detection limit (ppm) Digital output Guarantee Mass Measurement range (ppm) Operating temperature Power consumption Power supply operating voltage Pump flow rate/transport time Remote control Resolution (ppm) Sampling distance Exhaust Sampling distance Intake Size Tube Requirements Exhaust Tube Requirements Intake Wire requirements 4-20mA/DC power supply/relay Wire requirementsDigital output
Suction type stationary gas detector with built-in suction pump Midas-Part Number-MIDAS-E-NH3

MIDAS-E-NH3

Available upon quote Alarm 1/Alarm 2/Failure (NO, NC, latch can be changed arbitrarily) 1.0A@30VDC or 0.5A@125VAC 4-20mA 3-wire sink, 3-wire source, 4-wire isolated IEEE 802.3af-2003 ETL approval UL61010-1 Ed:3 CE mark: EN 50270:2006 (Type 2) EN 61000-6-4:2007 RC232C, PPP protocol Ammonia 9 Modbus®, TCP Ethernet, Power over Ethernet (PoE) LonWorks® (Option model: MIDAS-T-LON) 1 year 0.8kg 0~100 0~40℃ 5W or less Rated 24VDC±10% 0.5L/min/within 2~30 seconds (transport time depends on tube requirements) Operation via internet browser 0.1 Maximum 30m Maximum 30m (when using FEP tube) Recommended to use air filter 150x65x153mm Outer diameter 6.35mm x inner diameter 4.76 (mm) Outer diameter 6.35mm x inner diameter 3.18 (mm) 2-wire max. 14AWG Category 5 cable or equivalent, RJ45 connector
Suction type stationary gas detector with built-in suction pump Midas-Part Number-MIDAS-E-ASH

MIDAS-E-ASH

Available upon quote Alarm 1/Alarm 2/Failure (NO, NC, latch can be changed arbitrarily) 1.0A@30VDC or 0.5A@125VAC 4-20mA 3-wire sink, 3-wire source, 4-wire isolated IEEE 802.3af-2003 ETL approval UL61010-1 Ed:3 CE mark: EN 50270:2006 (Type 2) EN 61000-6-4:2007 RC232C, PPP protocol Arsine
germa
18ppb
70ppb
Modbus®, TCP Ethernet, Power over Ethernet (PoE) LonWorks® (Option model: MIDAS-T-LON) 1 year 0.8kg 0~200ppb
0~800ppb
0~40℃ 5W or less Rated 24VDC±10% 0.5L/min/within 2~30 seconds (transport time depends on tube requirements) Operation via internet browser 1ppb Maximum 30m Maximum 30m (when using FEP tube) Recommended to use air filter 150x65x153mm Outer diameter 6.35mm x inner diameter 4.76 (mm) Outer diameter 6.35mm x inner diameter 3.18 (mm) 2-wire max. 14AWG Category 5 cable or equivalent, RJ45 connector
Suction type stationary gas detector with built-in suction pump Midas-Part Number-MIDAS-E-HCL

MIDAS-E-HCL

Available upon quote Alarm 1/Alarm 2/Failure (NO, NC, latch can be changed arbitrarily) 1.0A@30VDC or 0.5A@125VAC 4-20mA 3-wire sink, 3-wire source, 4-wire isolated IEEE 802.3af-2003 ETL approval UL61010-1 Ed:3 CE mark: EN 50270:2006 (Type 2) EN 61000-6-4:2007 RC232C, PPP protocol Boron trichloride
dichlorosilane
hydrogen bromide
hydrogen chloride
0.24
0.72
Modbus®, TCP Ethernet, Power over Ethernet (PoE) LonWorks® (Option model: MIDAS-T-LON) 1 year 0.8kg 0~8 0~40℃ 5W or less Rated 24VDC±10% 0.5L/min/within 2~30 seconds (transport time depends on tube requirements) Operation via internet browser 1 Maximum 30m Maximum 30m (when using FEP tube) Recommended to use air filter 150x65x153mm Outer diameter 6.35mm x inner diameter 4.76 (mm) Outer diameter 6.35mm x inner diameter 3.18 (mm) 2-wire max. 14AWG Category 5 cable or equivalent, RJ45 connector
Suction type stationary gas detector with built-in suction pump Midas-Part Number-MIDAS-E-HCH

MIDAS-E-HCH

Available upon quote Alarm 1/Alarm 2/Failure (NO, NC, latch can be changed arbitrarily) 1.0A@30VDC or 0.5A@125VAC 4-20mA 3-wire sink, 3-wire source, 4-wire isolated IEEE 802.3af-2003 ETL approval UL61010-1 Ed:3 CE mark: EN 50270:2006 (Type 2) EN 61000-6-4:2007 RC232C, PPP protocol Hydrogen chloride (high concentration) 1.5 Modbus®, TCP Ethernet, Power over Ethernet (PoE) LonWorks® (Option model: MIDAS-T-LON) 1 year 0.8kg 0~15 0~40℃ 5W or less Rated 24VDC±10% 0.5L/min/within 2~30 seconds (transport time depends on tube requirements) Operation via internet browser 1 Maximum 30m Maximum 30m (when using FEP tube) Recommended to use air filter 150x65x153mm Outer diameter 6.35mm x inner diameter 4.76 (mm) Outer diameter 6.35mm x inner diameter 3.18 (mm) 2-wire max. 14AWG Category 5 cable or equivalent, RJ45 connector
Suction type stationary gas detector with built-in suction pump Midas-Part Number-MIDAS-E-HFX

MIDAS-E-HFX

Available upon quote Alarm 1/Alarm 2/Failure (NO, NC, latch can be changed arbitrarily) 1.0A@30VDC or 0.5A@125VAC 4-20mA 3-wire sink, 3-wire source, 4-wire isolated IEEE 802.3af-2003 ETL approval UL61010-1 Ed:3 CE mark: EN 50270:2006 (Type 2) EN 61000-6-4:2007 RC232C, PPP protocol Boron trifluoride
hydrogen fluoride
tungsten hexafluoride
0.72
1.05
Modbus®, TCP Ethernet, Power over Ethernet (PoE) LonWorks® (Option model: MIDAS-T-LON) 1 year 0.8kg 0~8
0~12
0~40℃ 5W or less Rated 24VDC±10% 0.5L/min/within 2~30 seconds (transport time depends on tube requirements) Operation via internet browser 0.1 Maximum 30m Maximum 30m (when using FEP tube) Recommended to use air filter 150x65x153mm Outer diameter 6.35mm x inner diameter 4.76 (mm) Outer diameter 6.35mm x inner diameter 3.18 (mm) 2-wire max. 14AWG Category 5 cable or equivalent, RJ45 connector
Suction type stationary gas detector with built-in suction pump Midas-Part Number-MIDAS-E-XHF

MIDAS-E-XHF

Available upon quote Alarm 1/Alarm 2/Failure (NO, NC, latch can be changed arbitrarily) 1.0A@30VDC or 0.5A@125VAC 4-20mA 3-wire sink, 3-wire source, 4-wire isolated IEEE 802.3af-2003 ETL approval UL61010-1 Ed:3 CE mark: EN 50270:2006 (Type 2) EN 61000-6-4:2007 RC232C, PPP protocol Nitrogen trifluoride 3.6 Modbus®, TCP Ethernet, Power over Ethernet (PoE) LonWorks® (Option model: MIDAS-T-LON) 1 year 0.8kg 0~40 0~40℃ 5W or less Rated 24VDC±10% 0.5L/min/within 2~30 seconds (transport time depends on tube requirements) Operation via internet browser 0.1 Maximum 30m Maximum 30m (when using FEP tube) Recommended to use air filter 150x65x153mm Outer diameter 6.35mm x inner diameter 4.76 (mm) Outer diameter 6.35mm x inner diameter 3.18 (mm) 2-wire max. 14AWG Category 5 cable or equivalent, RJ45 connector
Suction type stationary gas detector with built-in suction pump Midas-Part Number-MIDAS-E-BR2

MIDAS-E-BR2

Available upon quote Alarm 1/Alarm 2/Failure (NO, NC, latch can be changed arbitrarily) 1.0A@30VDC or 0.5A@125VAC 4-20mA 3-wire sink, 3-wire source, 4-wire isolated IEEE 802.3af-2003 ETL approval UL61010-1 Ed:3 CE mark: EN 50270:2006 (Type 2) EN 61000-6-4:2007 RC232C, PPP protocol Bromine
chlorine dioxide
0.036 Modbus®, TCP Ethernet, Power over Ethernet (PoE) LonWorks® (Option model: MIDAS-T-LON) 1 year 0.8kg 0~0.4 0~40℃ 5W or less Rated 24VDC±10% 0.5L/min/within 2~30 seconds (transport time depends on tube requirements) Operation via internet browser 0.01 Maximum 30m Maximum 30m (when using FEP tube) Recommended to use air filter 150x65x153mm Outer diameter 6.35mm x inner diameter 4.76 (mm) Outer diameter 6.35mm x inner diameter 3.18 (mm) 2-wire max. 14AWG Category 5 cable or equivalent, RJ45 connector
Suction type stationary gas detector with built-in suction pump Midas-Part Number-MIDAS-E-CO2

MIDAS-E-CO2

Available upon quote Alarm 1/Alarm 2/Failure (NO, NC, latch can be changed arbitrarily) 1.0A@30VDC or 0.5A@125VAC 4-20mA 3-wire sink, 3-wire source, 4-wire isolated IEEE 802.3af-2003 ETL approval UL61010-1 Ed:3 CE mark: EN 50270:2006 (Type 2) EN 61000-6-4:2007 RC232C, PPP protocol Carbon dioxide 0.15% Modbus®, TCP Ethernet, Power over Ethernet (PoE) LonWorks® (Option model: MIDAS-T-LON) 1 year 0.8kg 0~2.0% 0~40℃ 5W or less Rated 24VDC±10% 0.5L/min/within 2~30 seconds (transport time depends on tube requirements) Operation via internet browser 0.01% Maximum 30m Maximum 30m (when using FEP tube) Recommended to use air filter 150x65x153mm Outer diameter 6.35mm x inner diameter 4.76 (mm) Outer diameter 6.35mm x inner diameter 3.18 (mm) 2-wire max. 14AWG Category 5 cable or equivalent, RJ45 connector
Suction type stationary gas detector with built-in suction pump Midas-Part Number-MIDAS-E-COX

MIDAS-E-COX

Available upon quote Alarm 1/Alarm 2/Failure (NO, NC, latch can be changed arbitrarily) 1.0A@30VDC or 0.5A@125VAC 4-20mA 3-wire sink, 3-wire source, 4-wire isolated IEEE 802.3af-2003 ETL approval UL61010-1 Ed:3 CE mark: EN 50270:2006 (Type 2) EN 61000-6-4:2007 RC232C, PPP protocol Carbon monoxide 9 Modbus®, TCP Ethernet, Power over Ethernet (PoE) LonWorks® (Option model: MIDAS-T-LON) 1 year 0.8kg 0~100 0~40℃ 5W or less Rated 24VDC±10% 0.5L/min/within 2~30 seconds (transport time depends on tube requirements) Operation via internet browser 0.1 Maximum 30m Maximum 30m (when using FEP tube) Recommended to use air filter 150x65x153mm Outer diameter 6.35mm x inner diameter 4.76 (mm) Outer diameter 6.35mm x inner diameter 3.18 (mm) 2-wire max. 14AWG Category 5 cable or equivalent, RJ45 connector
Suction type stationary gas detector with built-in suction pump Midas-Part Number-MIDAS-E-HAL

MIDAS-E-HAL

Available upon quote Alarm 1/Alarm 2/Failure (NO, NC, latch can be changed arbitrarily) 1.0A@30VDC or 0.5A@125VAC 4-20mA 3-wire sink, 3-wire source, 4-wire isolated IEEE 802.3af-2003 ETL approval UL61010-1 Ed:3 CE mark: EN 50270:2006 (Type 2) EN 61000-6-4:2007 RC232C, PPP protocol Chlorine
Fluorine
0.18
0.36
Modbus®, TCP Ethernet, Power over Ethernet (PoE) LonWorks® (Option model: MIDAS-T-LON) 1 year 0.8kg 0~2.0
0~4.0
0~40℃ 5W or less Rated 24VDC±10% 0.5L/min/within 2~30 seconds (transport time depends on tube requirements) Operation via internet browser 0.01 Maximum 30m Maximum 30m (when using FEP tube) Recommended to use air filter 150x65x153mm Outer diameter 6.35mm x inner diameter 4.76 (mm) Outer diameter 6.35mm x inner diameter 3.18 (mm) 2-wire max. 14AWG Category 5 cable or equivalent, RJ45 connector

Click on the part number for more information about each product