Product
Oxygen concentration meter JKO-25 Ver.3Handling Company
Ichinen Manufacturing Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Accessories AC adapter | Accessories Common to all models | Accessories Wall bracket | Alarm concentration set value | Alarm delay | Alarm function | Alarm output | Analog output | Average sensor life *Not guaranteed | Battery life | Detection gas | Detection principle | Dimensions/mass | Eco alarm mode | Measurement accuracy | Measuring range | Operating humidity range | Operating temperature range | Power outage compensation mode | Power specifications External power supply | Power specifications: AA batteries | Power supply | Purpose | Resolution | Response speed | Sensor cable length | Sensor specifications Built-in type | Sensor specifications Separate type | Standard | Working pressure range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
JKO-25SD3 |
Available upon quote | ◯ | AA alkaline batteries, external alarm output connector | ◯ | 2 points can be set arbitrarily (initial value 18.0%) | Within 5 seconds (20.9→18.0%, when exposed to 10~11% oxygen) | Electronic buzzer (80dB), 2 blinking red LEDs | Relay no-voltage 1c contact Maximum allowable range: 1A 30VDC | DC 0-1V 0-100%O₂ | In the atmosphere: Approximately 3 years (varies depending on usage environment) | Approximately 1 year (no alarm) | Oxygen | Galvanic battery type | 145H×82W×38Dmm/315g JKO-25S3 | ◯ | ±0.5% (0.0~25.0%) ±3.0% (25.1% or more) | 0.0~100.0% | 5~85%RH (no condensation) | -10~+40℃ | ◯ | ◯ | ◯ |
4 AA alkaline batteries External power supply specifications: AC adapter 5V DC/2.0A (power outage compensation batteries: 4 AA alkaline batteries) |
・Prevention of oxygen deficiency ・Maintenance of oxygen concentrators and ventilators ・For inspection of hospital gas outlets ・Scientific experiments, culture tests |
0.1% | T90 within 20 seconds (20.9→100.0%) | - | ◯ | - | Low Voltage Directive, RoHS | Atmospheric pressure 1,013hPa±10% | |
JKO-25WD3 |
Available upon quote | ◯ | AA alkaline batteries, external alarm output connector | ◯ | 2 points can be set arbitrarily (initial value 18.0%) | Within 5 seconds (20.9→18.0%, when exposed to 10~11% oxygen) | Electronic buzzer (80dB), 2 blinking red LEDs | Relay no-voltage 1c contact Maximum allowable range: 1A 30VDC | DC 0-1V 0-100%O₂ | In the atmosphere: Approximately 3 years (varies depending on usage environment) | Approximately 1 year (no alarm) | Oxygen | Galvanic battery type | 145H×82W×38Dmm/315g JKO-25S3 | ◯ | ±0.5% (0.0~25.0%) ±3.0% (25.1% or more) | 0.0~100.0% | 5~85%RH (no condensation) | -10~+40℃ | ◯ | ◯ | ◯ |
4 AA alkaline batteries External power supply specifications: AC adapter 5V DC/2.0A (power outage compensation batteries: 4 AA alkaline batteries) |
・Prevention of oxygen deficiency ・Maintenance of oxygen concentrators and ventilators ・For inspection of hospital gas outlets ・Scientific experiments, culture tests |
0.1% | T90 within 20 seconds (20.9→100.0%) | 10m | - | ◯ | Low Voltage Directive, RoHS | Atmospheric pressure 1,013hPa±10% | |
JKO-25LD3 |
Available upon quote | ◯ | AA alkaline batteries, external alarm output connector | ◯ | 2 points can be set arbitrarily (initial value 18.0%) | Within 5 seconds (20.9→18.0%, when exposed to 10~11% oxygen) | Electronic buzzer (80dB), 2 blinking red LEDs | Relay no-voltage 1c contact Maximum allowable range: 1A 30VDC | DC 0-1V 0-100%O₂ | In the atmosphere: Approximately 3 years (varies depending on usage environment) | Approximately 1 year (no alarm) | Oxygen | Galvanic battery type | 145H×82W×38Dmm/315g JKO-25S3 | ◯ | ±0.5% (0.0~25.0%) ±3.0% (25.1% or more) | 0.0~100.0% | 5~85%RH (no condensation) | -10~+40℃ | ◯ | ◯ | ◯ |
4 AA alkaline batteries External power supply specifications: AC adapter 5V DC/2.0A (power outage compensation batteries: 4 AA alkaline batteries) |
・Prevention of oxygen deficiency ・Maintenance of oxygen concentrators and ventilators ・For inspection of hospital gas outlets ・Scientific experiments, culture tests |
0.1% | T90 within 20 seconds (20.9→100.0%) | 3m | - | ◯ | Low Voltage Directive, RoHS | Atmospheric pressure 1,013hPa±10% | |
JKO-25LJD3 |
Available upon quote | ◯ | AA alkaline batteries, external alarm output connector | ◯ | 2 points can be set arbitrarily (initial value 18.0%) | Within 5 seconds (20.9→18.0%, when exposed to 10~11% oxygen) | Electronic buzzer (80dB), 2 blinking red LEDs | Relay no-voltage 1c contact Maximum allowable range: 1A 30VDC | DC 0-1V 0-100%O₂ | In the atmosphere: Approximately 3 years (varies depending on usage environment) | Approximately 1 year (no alarm) | Oxygen | Galvanic battery type | 145H×82W×38Dmm/315g JKO-25S3 | ◯ | ±0.5% (0.0~25.0%) ±3.0% (25.1% or more) | 0.0~100.0% | 5~85%RH (no condensation) | -10~+40℃ | ◯ | ◯ | ◯ |
4 AA alkaline batteries External power supply specifications: AC adapter 5V DC/2.0A (power outage compensation batteries: 4 AA alkaline batteries) |
・Prevention of oxygen deficiency ・Maintenance of oxygen concentrators and ventilators ・For inspection of hospital gas outlets ・Scientific experiments, culture tests |
0.1% | T90 within 20 seconds (20.9→100.0%) | Approximately 1.75m | - | ◯ | Low Voltage Directive, RoHS | Atmospheric pressure 1,013hPa±10% | |
JKO-25ML3 |
Available upon quote | - | AA alkaline batteries, external alarm output connector | - | 2 points can be set arbitrarily (initial value 18.0%) | Within 5 seconds (20.9→18.0%, when exposed to 10~11% oxygen) | Electronic buzzer (80dB), 2 blinking red LEDs | Relay no-voltage 1c contact Maximum allowable range: 1A 30VDC | DC 0-1V 0-100%O₂ | In the atmosphere: Approximately 3 years (varies depending on usage environment) | Approximately 1 year (no alarm) | Oxygen | Galvanic battery type | 145H×82W×38Dmm/315g JKO-25S3 | ◯ | ±0.5% (0.0~25.0%) ±3.0% (25.1% or more) | 0.0~100.0% | 5~85%RH (no condensation) | -10~+40℃ | - | - | ◯ |
4 AA alkaline batteries External power supply specifications: AC adapter 5V DC/2.0A (power outage compensation batteries: 4 AA alkaline batteries) |
・Prevention of oxygen deficiency ・Maintenance of oxygen concentrators and ventilators ・For inspection of hospital gas outlets ・Scientific experiments, culture tests |
0.1% | T90 within 20 seconds (20.9→100.0%) | - | ◯ | - | Low Voltage Directive, RoHS | Atmospheric pressure 1,013hPa±10% | |
JKO-25MT3 |
Available upon quote | - | AA alkaline batteries, external alarm output connector | - | 2 points can be set arbitrarily (initial value 18.0%) | Within 5 seconds (20.9→18.0%, when exposed to 10~11% oxygen) | Electronic buzzer (80dB), 2 blinking red LEDs | Relay no-voltage 1c contact Maximum allowable range: 1A 30VDC | DC 0-1V 0-100%O₂ | In the atmosphere: Approximately 3 years (varies depending on usage environment) | Approximately 1 year (no alarm) | Oxygen | Galvanic battery type | 145H×82W×38Dmm/315g JKO-25S3 | ◯ | ±0.5% (0.0~25.0%) ±3.0% (25.1% or more) | 0.0~100.0% | 5~85%RH (no condensation) | -10~+40℃ | - | - | ◯ |
4 AA alkaline batteries External power supply specifications: AC adapter 5V DC/2.0A (power outage compensation batteries: 4 AA alkaline batteries) |
・Prevention of oxygen deficiency ・Maintenance of oxygen concentrators and ventilators ・For inspection of hospital gas outlets ・Scientific experiments, culture tests |
0.1% | T90 within 20 seconds (20.9→100.0%) | - | ◯ | - | Low Voltage Directive, RoHS | Atmospheric pressure 1,013hPa±10% |
Click on the part number for more information about each product