All Categories

History

“Cool Cannon” GNE9101, a large airflow air conditioner, is used to combat heat in factories and warehouses.-GNE9101
“Cool Cannon” GNE9101, a large airflow air conditioner, is used to combat heat in factories and warehouses.-NBC Engineer Co., Ltd.

“Cool Cannon” GNE9101, a large airflow air conditioner, is used to combat heat in factories and warehouses.
NBC Engineer Co., Ltd.

NBC Engineer Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

79.0hours


About This Product

■Product features

■Double fan delivers wide cold air that reaches up to 20m away

With 10HP (horsepower), it emits up to 130m3/min of wind. It can deliver wind at a speed of 1m/s up to 20m away, making it suitable for a wide range of facilities. *It is said that a wind speed of 1m/s lowers the perceived temperature by 4℃.

■Can be used in two separate areas with the optional flexible duct

A flexible duct can be attached to the air outlet. It can also be used like a spot cooler that blows air into a narrow area or specific location within a facility. It is also possible to perform spot ventilation and wide area ventilation at the same time.

■With a three-phase 200V 50A power supply, no special construction is required and installation is easy.

Since the exhaust unit is integrated, the installation layout is flexible. Wiring and piping are minimal, so they do not get in the way of work.

■Usage example 1

COOL CAN is an unprecedented type of mobile air conditioner that can deliver cold air over a wide range of 20 meters using a special double fan. Rather than cooling the entire building, which would be difficult to air condition throughout, it efficiently cools only areas where people are present, creating a comfortable environment.

■Usage example 2

If you attach the optional special flexible duct, it can be used like a spot cooler in a specific location without weakening the power of the cold air. In addition, since this product is a double fan, it can be used to suit various environments, such as attaching a flexible duct to only one side and using the other side for wide area use.

■Product comparison

The straight-line cold air reaches up to 20 meters away, allowing you to efficiently cool only the necessary spaces, such as your work space. By using the optional flexible duct, it is possible to simultaneously deliver wind to two large areas. *3-phase 200V 50A power supply is required for use. This product is an air conditioner, so in addition to the cooling function, it also has heating and blowing functions, and can adjust the temperature and wind power. Despite its large air volume, it is equipped with a high-efficiency EC fan, making it more energy efficient than other companies' products.

  • Product

    “Cool Cannon” GNE9101, a large airflow air conditioner, is used to combat heat in factories and warehouses.

Share this product


220+ people viewing

Last viewed: 12 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of “Cool Cannon” GNE9101, a large airflow air conditioner, is used to combat heat in factories and warehouses.

Image Part Number Price (excluding tax) Power supply Piping Connection pipe diameter Liquid/Gas (mm) Piping Indoor unit drain Year-round energy consumption efficiency (APF2015) Earth leakage breaker (for power supply design) (A) Maximum operating current (A) Outdoor unit blower motor output (kW) Outdoor unit mass (kg) Outdoor unit compressor Indoor unit air volume (m2/min) Indoor unit motor output (kW) Indoor unit mass (kg) Indoor unit external static pressure (Pa) Rated capacity (maximum) Rated power consumption External dimensions Height x Width x Depth (mm) Refrigerant Operating temperature range Heating (℃) Operating temperature range Cooling (℃) Energy consumption efficiency COP Accessories
“Cool Cannon” GNE9101, a large airflow air conditioner, is used to combat heat in factories and warehouses.-Part Number-GNE9101

GNE9101

Available upon quote

Three phase 200V 50Hz/60Hz

Φ12.7/φ25.4

R1 male thread

3.5

50

41.7

0.4

125

Format: Fully sealed
Nominal output: 6.0kW
Legal frozen ton: 0.500~3.680

80 (External static pressure 130m2/min at OPa)

0.558

78

80

Cooling (kW): 25.0 (28.0)
Heating (kW): 28.0 (31.9)

Cooling (kW): 8.91
Heating (kW): 7.30

1,861×1,700×1,000

R410A

Indoor: Dry bulb temperature: 17~28
Outdoors: Wet bulb temperature: -20~15

Indoors: Wet bulb temperature: 15~23
Outdoors: Dry bulb temperature: -5~43

Cooling: 2.81
Heating: 3.84

Polyethylene net filter
remote control
Angle for anchoring
power cable

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Cooling Fans Products

Other products of NBC Engineer Co., Ltd.

Reviews shown here are reviews of companies.


View more products of NBC Engineer Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

79.0hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree